Reports filed under 2160 · Cabin Temperature Control System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2160'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2017100401928Switch · inoperativeFWD CARGO HEAT OV/HEAT INOP. R&R SWITCH ASSY FOR FWD CARGO HEAT, OPS CKD GOOD PER AMM 33-13-00.Oct 1, 2017 · N641GT · Boeing 76738ESDR ASAA2017092822065Warning Light · noneZONE TEMP CONTROL CABIN ILLUMINATED ON MASTER RECALL. LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62 TASK 842. NO FAULTS. PACK OPS NORMAL IAW AMM. 21-00-00.Sep 28, 2017 · N530AS · Boeing 737890SDR COZA20170929113Controller · intermittentBITE CHECK OF THE CABIN TEMPERATURE CONTROLLER INDICATED AN INTERNAL FAILURE OF THE CONTROLLER. REPLACED THE CABIN TEMPERATURE CONTROLLER AND OPERATIONAL CHECK NORMAL.Sep 27, 2017 · N737KA · Boeing 7377BXSDR ASAA2017092722064Filter · obstructedF/A REPORTED AN EXCESSIVELY HOT TEMPERATURE AT ROWS 6 - 12. TRIM AIR TURNED OFF IAW QRH. ACFT GROUNDED. RETURNED TRIM AIR SWITCH TO ON. BITE CHECKED BOTH ZONE TEMP CONTROLLERS IAW FIM 21-61, TASK 801, NO FAULTS. FOUND FWD ZONE FAN FILTER COMPLETELY BLOCKESep 27, 2017 · N423AS · Boeing 737990ERSDR P5CA2017092600339Warning Message · false activationEICAS MESSAGE AFTER TAKEOFF. FWD CARGO BACKUP; THEN EXTINGUISHED DURING CLIMB. PERFORMED A BITE TEST OF ZONE TEMP. CONTROLLER TEST OK.Sep 26, 2017 · N647GT · Boeing 767306SDR UIEA2017092501852Modulating Valve · malfunctionedAFT CABIN TEMP MESSAGE. REMOVED AND REPLACED AFT TRIM AIR MODULATING VALVE IAW AMM 21-61-07 LEAK AND OPS CHECKED GOOD.Sep 25, 2017 · N1181A · Boeing 7673Y0SDR P5CA2017092500338Warning Message · false activationEICAS MESSAGE AFTER TAKEOFF, FWD CARGO BACKUP EICAS MESSAGE. EXTINGUISHED DURING CLIMB. PERFORMED A BITE TEST OF ZONE TEMP CONTROLLER, TESTED OK IAW AMM 21-61-00.Sep 25, 2017 · N647GT · Boeing 767306SDR ASAA2017092222002Warning Light · false activationON RECALL ZONE TEMP LIGHT FOR CONT CAB ILLUMINATED. RAN QRH PROCEDURE, LIGHT WENT OUT WHEN MASTER CAUTION PUSHED. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST ON BOTH NR 1 & 2 CONTROLLERS. NR 1 CONTROLLER TEST PASSED WITH NO FAULTS. NR 2 Sep 22, 2017 · N586AS · Boeing 737890SDR P5CA2017092200335Unknown · unknownFLT DECK TEMP FLUCTUATES BETWEEN 18 AND 26 DEG C WITH NO OR MINIMAL INPUT. ZONE TEMP CONTROL BITE TEST NORMAL. CLEANED FLT DECK AIR FILTER AND COCKPIT TEMP BULB ,OPS CHECKED NORMAL IAW AMM 21-65-03, AMM 21-61-09, AND AMM 21-61-03.Sep 22, 2017 · N644GT · Boeing 7673JHFSDR ASAA2017092021988Filter · dirtyCONTROL CABIN ZONE TEMP LIGHT, RECALL RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. FOUND THE FLT DECK TRIM VALVE FAULT NR 2 PACK-ZONE TEMP CONTROLLER. RESET FAULT. FOUND CONTROL CABIN TEMP SENSOR ASSY FILTER DIRTY. RESET FAULT AND CLEANED THE TEMP SENSep 20, 2017 · N472AS · Boeing 737990ERSDR UIEA2017092001754Sensor · failedFLT DECK TEMP CONTROLLER INOPERATIVE. BITE CHECKED AUTO CONTROLLER, FAILED FLT DECK TEMP SENSOR TS175, REMOVED AND REPLACED THE SENSOR IAW AMM 21-61-02, OPS CHECKED GOOD .Sep 19, 2017 · N1181A · Boeing 7673Y0SDR UIEA2017092701886Control Panel · inoperativeTEMP PNL M14 FLT DECK TRIM IN DOES NOT RESPOND WHEN SELECTING TEMPERATURE. REPLACED TEMP CONT PNL (M14).Sep 17, 2017 · N1327A · Boeing 767300SDR UIEA2017092001748Controller · failedLEFT PACK TEMP CONTROLLER M126 FAILED. REPLACED THE TEMP CONTROLLER.Sep 17, 2017 · N1327A · Boeing 76737DSDR ASAA2017091721943Warning Message · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. RESET ON CAUTION RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE MULTIPLE TIMES, INITIAL FAULT SHOWN FLT DECK TRIM VALVE , TEMP CONTROLLER NR 2 . RESET FAULT, FAULT DID NOT RETURN. RAN RT PSep 17, 2017 · N583AS · Boeing 737890SDR ASAA2017091521939Warning Light · false activationZONE TEMP CONTROL LAMP ILLUMINATED AFTER START. ACCOMPLISHED ZONE TEMP, LIGHT ILLUMINATED PG 21.1. LT. EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. FOUND THE NR 2 TEMP CONTROLLER WITH FLT DECK TRIM VALVE FAULT LIGHT ON WHEN BIT SELECTED. PERFORMSep 15, 2017 · N533AS · Boeing 737890SDR UIEA2017091501672Valve · faultedAFT CABIN TEMP EICAS DISPLAYED WITH AFT CABIN AUTO INOPERATIVE LIGHT ILLUMINATED DURING TAXI. REMOVED AND REPLACED THE AFT CABIN TRIM AIR VALVE ACTUATOR IAW AMM 21-61-07, OPS CHECKED GOOD.Sep 14, 2017 · N1229A · Boeing 767306SDR P5CA2017091500330Warning Message · false activationEICAS MESSAGE FOR FWD CARGO BACKUP. CHECKED TEMP CONTROLLER & BITE TEST CARRIED OUT. NO RELATED FAULTS NOTED. EICAS MESSAGE SELF CLEARED IAW AMM 21-61-00.Sep 14, 2017 · N647GT · Boeing 767306SDR QXEA2017091500567Environ Sys · malfunctionedAFTER TAKEOFF, COCKPIT DUCT HOT AND CABIN DUCT HOT CAUTIONS ILLUMINATED. UNABLE TO CONTROL IN AUTO OR MANUAL, AIRFLOW WEAK. RETURNEN TO FIELD. LANDING UNEVENTFUL. REMOVED FROM SERVICE. FIM TROUBLESHOOTING OF LOW AIR FLOW FROM CABIN IAW 21-60-00-810-882, NO DSep 13, 2017 · N419QX · Bombdr DHC8402SDR P5CA2017091300326Warning Message · false activationFWD CARGO BACKUP EICAS AFTER TAKE OFF, THIRD RIGHT UP. TEMP CONTROLLER CIRCUIT BREAKER RESET AND BITE TEST PERFORMED IAW AMM 21-61-00, OK.Sep 13, 2017 · N647GT · Boeing 767306SDR P5CA2017091100323Relay · failedEICAS MESSAGE FOR THE FWD CARGO BKUP. THE FWD CARGO DUCT OVERHEATT& RELAY K1222 REPLACED IAW WDM 21-61-81 ,. BITE TEST CARRIED OUT SATISFACTORY.Sep 9, 2017 · N647GT · Boeing 767306SDR ASAA2017090921857Warning Light · false activationAFTER ENGINE START, MASTER CAUTION RECALL AIR CONDITIONER WITH ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. IAW AMM 21-62-801, PERFORMED BITE CHECK OF BOTH PACKS TEMP CONTROLLERS, CLEARED ALL FAULTS, LIGHT EXTINGUISHED AND SYSTEM NOW OPS NORMAL.Sep 9, 2017 · N566AS · Boeing 737890SDR ASAA2017090921856Controller · malfunctionedON DESCENT CHECKLIST, PRESSED RECALL, ZONE TEMP FOR CONTROL CABIN ILLUMINATED, RAN CHECKLIST. ZONE TEMP FOR CONTROL CABIN RESET ON MASTER CAUTION. ACFT GROUNDED. CONTROLLER LOGGED TRIM VALVE FAULT, ACCOMPLISHED PACK / ZONE TEMP CONTROLLER BITE TEST PROCEDURSep 9, 2017 · N593AS · Boeing 737890SDR ASAA2017090921855Controller · faultedDURING MASTER CAUTION RECALL AMBER CONTROL CABIN AND FWD CABIN ZONE TEMP AND RIGHT PACK AMBER LIGHT ILLUMINATED. ALL THREE AMBER LIGHTS EXTINGUISHED DURING MASTER CAUTION SYSTEM RESET. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 PACK/ZONE TEMP CONTROLLER. Sep 9, 2017 · N493AS · Boeing 737990ERSDR ASAA2017090921851Filter · dirtyAFTER ENGINE START MASTER CAUTION RECALL AIRCOND WITH ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. IAW AMM 21-61-10 CLEANED THE CABIN TEMP SENSORS AND FILTERS PERFORMED BITE OF BOTH CONTROLLERS (ZONE TEMP) PERFORMED ENG RUN OPERATED BOTH PACKS GROUND VERIFICASep 9, 2017 · N566AS · Boeing 737890SDR P5CA2017091100321Warning Light · false activationAFTER TAKEOFF, AN EICAS MESSAGE FOR THE FWD CARGO BACKUP. RESET ZONE TEMP CONTROL SYSTEM AND PERFORMED ZONE TEMP CONTROLLER BITE TEST SHOWN GO LIGHT IAW AMM 21-61-00. SYSTEM OK FOR CONTINUE SERVICE.Sep 8, 2017 · N647GT · Boeing 767306SDR ASAA2017083121783Control Valve · stuckRIGHT TCV HAD A RECENT FAULT HISTORY AND CABIN TEMP ISSUES. ACFT GROUNDED. REMOVED AND REPLACED THE RT TEMP CONTROL VALVE IAW AMM 21-51-10/401. PERFORMED BITE TEST IAW AMM 21-51-00-700-803. VALVE FOUND STUCK.Aug 31, 2017 · N431AS · Boeing 737990ERSDR ASAA2017082321699Module · failedSUPPLY DUCT AIR TEMP GAUGE READS HIGH AND BOUNCES AROUND WHEN SELECTED TO READ CONTROL CABIN TEMP. AIR TEMPERATURE OPERATES CORRECTLY WHEN CHANGING RHEOSTAT, GAUGE JUST READS HIGH ANYWHERE FROM 40 DEGREES TO 100 DEGREES EVEN WITH COOL AIR BLOWING. ACFT GROUNAug 23, 2017 · N435AS · Boeing 737990ERSDR DXTAT2PL6D005BQW8Water Separator · odorODORS IN THE COCKPIT DURING FLIGHT WITH APU RUNNING. SMELLS LIKE BURNED OIL. INSPECTED THE APU INLET AND EXHAUST, APU BLEED AIR DUCT AND HEAT EXCHANGER DUCT, WATER SEPERATOR AND CLEANED WATER SEPARATOR SOCK IAW MM 12-19-02. REINSTALLED WATER SEPERATOR AND Aug 22, 2017 · N617QS · Cessna 560XLSDR YENA201708200678Condenser · crackedRETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK, THE TEMPS CONTINUED TO CLIMB. TROUBLESHOT AND FOUND LOW REGULATING PRESSURE IN THE NR 1 PACK, R & R THE FLOW Aug 20, 2017 · N659JB · Airbus A320232SDR YENA201708200677Solenoid Valve · failedRETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK. THE TEMPS CONTINUED TO CLIMB. TROUBLESHOT AND FOUND LOW REGULATING PRESSURE IN THE NR 1 PACK, R & R THE FLOAug 20, 2017 · N659JB · Airbus A320232SDR YENA201708200676Control Valve · failedRETURN TO FIELD DUE TO THE COCKPIT TEMP WAS UNCONTROLLABLE, OUTPUT REACHED 118 DEGREES AND COCKPIT TEMP REACHED 94 DEGREES. TURNED OFF THE NR 2 PACK THE TEMPS CONTINUED TO CLIMB; TROUBLESHOT AND FOUND LOW REGULATING PRESSURE IN THE NR 1 PACK, R & R FLOW CONTRAug 20, 2017 · N659JB · Airbus A320232SDR P5CA2017081500275Controller · malfunctionedEICAS MESSAGE AFT CABIN TEMP. REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER IAW AMM 21-61-03. OPS CHECKED GOOD.Aug 15, 2017 · N642GT · Boeing 7673Y0SDR P5CA2017081100262Heater · no testUNABLE TO GET EICAS MESSAGE, AFT CARGO HEAT DURING TEST. FOUND RELAY CABLES K229 AND K790 SWAPPED, CHECKED WIRING AND PIN ON CONNECTOR DB0694 RELAY K229 IAW WDM 21-44-11, PG 2. OPS CHECKED GOOD.Aug 10, 2017 · N642GT · Boeing 7673Y0SDR P5CA2017081100263Controller · no testA-21-025-00-01 STEP 13D,E OF WORK CARD FAILED TRIM VALVE AT FLIGHT DECK IS NOT OPENING. REMOVED AND REPLACED ZONE TEMP CONTROLLER IAW AMM 21-61-03-404-016, OPS CHECKED GOOD.Aug 10, 2017 · N642GT · Boeing 7673Y0SDR ASAA2017080921582Control Valve · faultedLEFT AND PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. REMOVED & REPLACED LEFT AFT TRIM VALVE IAW AMM 21-51-10 AND AMM 21-51-00-700-803. PZTC BITE TEST CHECKED GOOD. ALL TEST SHOWED GREEN LIGHT. OPS NORMAL.Aug 9, 2017 · N459AS · Boeing 737990ERSDR ASAA2017080921581Control Valve · faultedZONE TEMP IN CONTROL CABIN LIGHT ILLUMINATED. FOLLOWED QRH. LIGHT ILLUMINATED INTERMITTENTLY AND THEN REMAINED ON. SUPPLY DUCT TEMP WAS CONTROLLABLE; WE OPERATED IN THE OFF POSITION. GROUNDED - YES. PERFORMED PACK TEMP CONTROLLER BITE ON BOTH CONTROLLERS IAW BAug 9, 2017 · N516AS · Boeing 737890SDR ASAA2017080821567Warning Message · false activationECS TEMPERATURE INDICATIONS SHOW ERRONEOUS READINGS FOR ALL SEVEN POSITIONS. ALL SEVEN INDICATIONS SHOW WELL BELOW 20C. FLIGHT ATTENDANT REPORTED NORMAL TEMPERATURE IN BOTH FWD & AFT CABIN WITH THE INACCURATE READINGS. ACFT GROUNDED. CYCLED AIR TEMP SWITCH FAug 8, 2017 · N413AS · Boeing 737990ERSDR ASAA2017080821566Warning Light · false activationCONTROL CABIN COMES ON WITH MASTER CAUTION RECALL. ACFT GROUNDED. CLEARED THE NR 2 CONTROLLER FLIGHT DECK SELECTOR FAULT. ACCOMPLISHED BITE TEST OF BOTH CONTROLLERS IAW AMM 21-61-00. NO FAULTS NOTED. GROUND VERIFICATION SUCCESSFUL.Aug 8, 2017 · N506AS · Boeing 737890SDR ASAA2017080521533Indicator · failedAIR TEMPERATURE INDICATION FOR CONT CAB SUPPLY DUCT IS INTERMITTENTLY INDICATING FULL HOT 100DEG C. DISPITE TURNING TEMP CONTROL TO FULL COLD. DUCTS ARE BLOWING FULL COLD DESPITE MAX TEMP INDICATION. TEMP WILL OCCASIONALLY SHOW COOLING AND THEN BOUNCE BACK TO Aug 5, 2017 · N435AS · Boeing 737990ERSDR ASAA2017080121515Control Valve · erraticCONTINUED REPORTS OF FLIGHT DECK TEMP CONTROL ERRATIC. ACFT GROUNDED. REMOVED AND REPLACED THE CABIN TEMP CONTROL MODULE IAW AMM 21-61-15, OPS CHECKED GOOD.Aug 1, 2017 · N538AS · Boeing 737890SDR ASAA2017073121510Control Knob · malfunctionedFLIGHT DECK TEMPERATURE SELECTOR DOES NOT CONTROL THE FLIGHT DECK TEMPERATURE WITHIN LIMITS. IT IS UNRESPONSIVE BETWEEN THE 10 O'CLOCK AND 1 O'CLOCK POSITION. THIS RESULTS IN THE CONT CAB DUCT SUPPLY TEMPERATURE TO STABILIZE AT 15 C OR 65 C, BUT NO TEMPERATUREJul 31, 2017 · N538AS · Boeing 737890SDR UIEA2017072901377Transmitter · failedEICAS DISPLAY FOR LT PACK PRIMARY HX IN NO INDICATION. THE TEMP TRANSMITTER WAS REMOVED AND REPLACED IAW AMM 21-52-03, REV 121. OPS TESTED IAW AMM 21-52-03, REV 121.Jul 31, 2017 · N1361A · Boeing 76731BSDR UIEA2017072801342Sensor · corrodedRIGHT PACK COMPRESSOR OUTLET TEMP 2 SENSOR (TS5135) FOUND CORRODED. THE TEMP SENSOR WAS REMOVED AND REPLACED IAW AMM 21-56-06, REV 121. OPS TESTED IAW AMM 21-56-06, REV 121.Jul 31, 2017 · N1361A · Boeing 76731BSDR UIEA2017072801341Bulb · corrodedRIGHT PACK COMPRESSOR INLET TEMP BULB FOUND CORRODED. THE INLET TEMP BULB WAS REMOVED AND REPLACED IAW AMM.Jul 31, 2017 · N1361A · Boeing 76731BSDR ASAA2017072921477Filter · cloggedDURING RECALL CONT CAB ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION. RESET LIGHT EXTINGUISHES. ACFT GROUNDED. PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62 TASK 801 SHOWED RIGHT PZTC FAULT FOR FLIGHT DECK TRIM VALVE. ACCOMPLISHED T/S FOR FLIGHT DECK TRIM VALVEJul 29, 2017 · N477AS · Boeing 737990ERSDR UIEA2017073001381Valve · failedAFT CABIN TEMP EICAS MESSAGE DURING CRUISE. QRH COMPLIED WITH, ASSOCIATED AFT CABIN CONTROLLER INOPERATIVE. REMOVED AND REPLACED TRIM MODULATING VALVE IAW AMM 21-61-07, OPS CHECKED NORMAL.Jul 29, 2017 · N1229A · Boeing 767306SDR ASAA2017072921485Circuit Breaker · trippedFOUND CIRCUIT BREAKER TRIPPED, AFT PAX ZONE TEMP DUCT OVERHEAT. ACFT GROUNDED. RESET THE CIRCUIT BREAKER IAW AMM 20-60-01. PERFORMED A PACK/ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-61-00 AND ALL OPS CHECKED GOOD, NO CURRENT FAULT, NO HISTORY 30 DAYS.Jul 29, 2017 · N431AS · Boeing 737990ERSDR ASAA2017072921478A/C Pack · malfunctionedCONTROL CABIN TEMP SPIKES FROM COLD AIR TO FULL HOT WHEN CONTROLLER KNOB MOVED FROM POINTING TO THE B IN CABINE TO THE WHITE DOT JUST A SLIGHT BIT TO THE RIGHT. STAYS UNCOMFORTABLY COLD. ACFT GROUNDED. REBOOTED ACFT POWER. PERFORMED IAW AMM TASK 21-61-00-70Jul 29, 2017 · N538AS · Boeing 737890SDR ASAA2017072821486Fan · disconnectedAFT PAX CABIN VERY HOT DESPITE TEMP GAUGE SHOWING SAME 23C AS FWD CABIN. IT TAKES AFT CABIN CONTROLLER FULL COLD TO MANAGE AFT CABIN PAX. DUCT PRESSURE NORMAL. ACFT GROUNDED. FOUND THE AFT CABIN TEMP SENSOR FAN NOT WORKING. DROPPED FAN ACCESS PANEL AND FOUND Jul 28, 2017 · N453AS · Boeing 737990ERSDR ASAA2017072721480A/C Pack · malfunctionedAFT CABIN TEMP CONTROL INOPERATIVE. TEMP RUNS FULL COLD THROUGH 50+C IN ALL POSITIONS (OFF, AUTO, MANUAL) TRIM AIR HAS NO EFFECT ON CONTROL. SET TO AVERAGE 10*C FOR PAX. . ACFT GROUNDED. PERFORMED FIM 21-61 TASK 801, CABIN TEMP CONTROL BITE PROCEDURE. FOUNJul 27, 2017 · N453AS · Boeing 737990ER
Back to JASC 2160