SDR CALA2026072718051Oven · smokeOVEN 606 GENERATED HEAVY BLACK SMOKE WHEN OPERATING. REMOVED TRAYS FROM OVEN & CLEARED DEBRIS FROM BOTTOM AND BACK TO PERFORM OPS TEST IAW AMM 25-32-02-200-802-001. WHITE SMOKE CAME OUT WITHIN ONE MINUTE OF STARTING WARMING CYCLE. REMOVED AND REPLACED THE OSDR YENA2026072400621Galley · contaminatedFLT 536, STI-JFK. STRONG ODOR IN AFT GALLEY SIMILAR TO DEAD ANIMAL ODOR QE MX 270 FORM SUBMITTED; THOROUGHLY INSPECTED AFT GALLEY AND FOUND AFT GALLEY COMPARTMENT 308 312 AND 313 CONTIMANTION WITH STANDING WATER THOROUGHLY CLEANED ALL COMPARTMENTS UNTIL DRY NOSDR SWAA2026072234266Coffeemaker · odorF/A REPORT PLASTIC BURNING ODOR IN LAST FEW ROWS AND GALLEY DURING DESCENT PERFORMED SMOKE OR FUMES IN CABIN COND INSP PER AMM 05-51-56. FOUND AFT NR 1 C/M HAS BURNED COFFEE SMELL. REF L/P 3033689 FOR DEFERRAL. NO OTHER ISSUES FOUND. A/C OK FOR SERVICE.SDR DALA2026072104265Coffeemaker · odorAT CRUISE FL 330, THE AFT FA CALLED ABOUT A BURNING SMELL IN VERY BACK AFT GALLEY. NO ECAM OR VISIBLE SMOKE. WITHIN MINUTES SMELL WAS GONE. REPLACED AFT GALLEY A508 COFFEE MAKER UNIT IAW CMM 25-33-50. CHKD GOOD. (LP 8726038 - AIRCRAFT WAS GROUNDED)SDR DALA2026072104266Warmer · odorATTENDANTS NOTICED FAINT SMELL OF BURNING THAT SEEMED TO BE SIMILAR TO THE SMELL OF AN ELECTRICAL FIRE. NO SMOKE OR FLAMES WERE SEEN. REPLACED BUN WARMER ALL IAW B767 CMM 25-05-70 OK FOR SVC. (LP 1708811 - AIRCRAFT WAS GROUNDED)SDR DALA2026072004256Oven · contaminatedDIV- TO DTW DUE TO BURNING ODOR IN AFT GALLEY. AFT GALLEY OVENS 2, 3 AND 5 CONTAMINATED WITH FOOD. REPLACED OVENS AND NR 1 CHILLER.SDR CALA2026072017880Oven · contaminatedCONTAINED PASTA FIRE IN OVEN 109 FRONT GALLEY REF AMM 05-51-58-800-801-C3 AND GMM 04-20-16. REMOVED OVEN AND INSPECTED EXTERIOR OF OVEN, GALLEY INTERIOR OVEN CAVITY, WIRE HARNESS, POWER POINT PLUGS & FOUND NO FIRE, HEAT OR SMOKE DAMAGE. REPLACED OVEN AT POSISDR AALA202607222380Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTED THE FORWARD GALLEY HAD A SMELL OF BURNING PLASTIC AND BELIEVED IT IS POSSIBLY ASSOCIATED WITH FORWARD GALLEY OVEN USE BECAUSE THE SMELL DISSIPATED WHEN OVENS WERE TURNED OFF. THE FLIGHT ATTENDANTS ALSO REPORTED SDR AALA202607200357Oven · smokeAIRCRAFT WAS NOT GROUNDED: GALLEY 9 OVEN SMOKES WHEN TURNED ON. MAINTENANCE CLEANED OVEN#09 OPS CHECKED NORMAL AS PER AMM 25-32-00.SDR AALA202607205615Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFT CHILLER WAS MAKING LOTS OF NOISE AND THEN HAD A SLIGHT BURNING SMELL SO FLIGHT ATTENDANTS SHUT IT OFF. MAINENANCE REPLACED CHILLER PER AMM 25-34-51 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR SWAA2026072097679Coffeemaker · odorFWD COFFEE POT HAS SLIGHT BURNING ODOR. R & R THE COFFEE MAKER IAW AMM 25-30-01. OPS CK GOOD.SDR CALA2026071417778Oven · contaminatedFA REPORTS ACRID SMELL IN FA BUNK AND ALSO CHEC ED PILOT AREA. LOCATED CREW BUNK HEATERS AND RAN OPS CHECK OF HEATERS AND SUPPLY VALVES PER AMM 21-29-00. OPS CHECK GOOD NO DEFECTS NOTED M&L UPDATE. UPON COMPLETION OF CONDITION INSPECTION PER AMM 05-51-58-800SDR CALA2026071517791Oven · smokeOVEN 407 SMOKE WHEN DOOR OPEN. DPWRED. SMOKE DISIPATED. OVEN WAS PREVIOUSLY CLEANED AT LAST STATION L/P 9574711. AFTER SMOKE OR FUMES IN CABIN INSPECTION AMM 05-51-99, IF OVEN IS CONFIRMED SOURCE OF SMOKE, REMOVED AND REPLACED OVEN AT 407 IAW AMM 25-32-00. SDR CALA2026071417786Oven · odorSMOKE FROM FWD GALLEY OVEN DEBRIEFED FLIGHT CREW AND FLIGHT ATTENDENTS CONFRIMING BURNT FOOD ODOR COMING FROM FWD GALLEY OVEN 204. NO OTHER DISCREPANCIES NOTED AT THIS TIME. REPLACED FOWARD GALLEY OVEN AT POSITION G22, PERFORMED OPS CHK, CHKD GOOD WITH NO DESDR J7SA2026072200486Microwave Oven · odorDIVERTED DUE TO A STRONG ELECTRICAL BURNING SMELL IN THE COCKPIT DURING CRUISE, ISOLATED TO THE GALLEY MICROWAVE OVERHEATING. THE CREW DISCONTINUED MICROWAVE USE AND DIVERTED TO LIML. AIRCRAFT LANDED WITHOUT INCIDENT AT LIML. REPLACED MICROWAVE IAW AMM 25-32-0SDR AALA202607148853Oven · smokeAIRCRAFT WAS NOT GROUNDED: OVEN #2 SMOKES WHEN USED. (FLIGHT ATTENDANT SUSPECTED IT IS DUE TO ADHESIVE RESIDUE FROM TAPE THAT WAS INSIDE THE OVEN). MAINTENANCE REPLACED THE OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO ISSUES SDR DALA2026071304080Oven · odorFORWARD GALLEY OVEN MOTOR SEVICE LIGHT ON AS WELL AS METAL BURNING SCENT COMING FROM OVEN. OVEN ISN'T HEATING MEALS UP AND THE OVEN TEMPERTURE WAS DECREASING AND INECRESING AT RANDOM POINTS DURING HEATING MEALS. OVEN BEING DEFFERED TO NEF 25-34-02 DUE TO BURNSDR SWAA2026071319611Coffeemaker · odorSTRONG ELECTRICAL ODOR IN AFT GALLEY. ISOLATED TO AFT COFFEE POT FO SIDE. PULLED BRAKERS FOR LIGHTS AND COFFEE POT; ODOR WENT AWAY. VERIFIED ALL CIRCUIT BREAKERS WERE RESET. PERFORMED SMOKE/FUME INSPECTION. NO SMOKE/FUME DETECTED. REMOVED AND INSTALLED AFT RSDR DALA2026071404137Coffeemaker · damagedCOFFEE MAKER DAMAGED, INOPERATIVE, AFT GALLEY COFFEE MAKER MADE POPPING SOUND AND THEN SMELLED ACRID SMELL. TURNED OFF UNIT AND SMELL WENT AWAY / INTERIOR. REMOVED BEVERAGE MAKER AND INSPECTED WIRING HARNESS AND ASSOCIATED CONNECTORS. NO DEFECTS NOTED. INSTALSDR CALA2026070917621Oven · smokeALL SIX AFT GALLEY OVENS SMOKING WITH LOUD HUMMING NOISE 706 707 LARGE WHITE SMOKE FA SAYS SMELLS LIKE ELECTRICAL SMOKE DURING OVEN OPERATION.AFTER SHUTTING OFF OVENS706 707., 711 710 709 SERVICE REQUIRED LIGHT CAME ON FA PULLED ALL OVEN CBS.OBSERVED SIGNS OF SDR AALA202607086888Fan · burned outAIRCRAFT WAS GROUNDED: PREVIOUS WRITE UP. G5 CHILLER FAN REPORTED AS VERY NOISY. F/A REPORTED SMOKE BURNING WIRE SMELL. PER MIC 4693889 MAINTENANCE REPLACED CHILLER IN GALLEY G5 AFT LOCATION AREAS AS REQUIRES I.A.W. AMM 25-33-01.SDR CALA2026070817612Circuit Breaker · brokenFOUND CB FOR RT HEATED HOSE, HEAD HAS BEEN SHEARED OFF AT AFT GALLEY. REPLACED C0513 RT HEATED HOSE CIRCUIT BREAKER AT AFT GALLEY IAW SWPM 20-30-00 AND IAW CMM 25-68-31.SDR DALA2026070904042Oven · odorAFTER RUNNING OVEN, VERY STRONG BURNING/PLASTIC ODOR IN GALLEY AREA. WHEN OVEN DOOR WAS OPENED ODOR INCREASED. NO PLASTIC OR OTHER MELTABLE ITEMS IN OVEN. IMMEDIATELY SHUT OVEN AND ALL OTHER GALLEY EQUIPMENT OFF. REMOVED AND REPLACED OVEN IAW AMM 25-31. (168SDR SWIA2026070576445Coffeemaker · odorODOR OF SMOKE COMING FROM GALLEY. SMALL AMOUNT OF SMOKE VISIBLE. COULD NOT PIN POINT THE LOCATION OF ODOR OR SMOKE. (FLIGHT 4245) COMPLIED WITH FIM 21-22-00-810-806. CONFIRMED WITH CREW SMOKE CAME FROM COFFEE MAKER NR 1 (LEFT) DURING PREFLIGHT. AIRCRAFT WAS SDR SWAA2026070718692Coffeemaker · odorAFTER GALLEY NR 1 COFFEE POT HAD SLIGHT BURNING ODOR. FAS PULLED CIRCUIT BREAKER AND ODOR WENT AWAY. OPS CHKD.NR 1 & 2 AFT COFFEE MAKERS IAW AMM 25-30-01. R&R #1 COFFEE MAKER AS PRECAUTION. IAW AMM 25-30-01. OPS CHKD GOOD AT THIS TIME.SDR CALA2026070617567Coffeemaker · contaminatedCOFFEE FROM AFT COFFEE MAKERS HAS STRONG DETERGENT TASTE, PLACED BOTH AFT COFFEE MAKERS ON DEFERRAL. COMPLIED WITH MX SECTION PULLED AND COLLARD C/B. PERFORMED OPS CHECK IAW AMM 25-32-01 MULTIPLE TIMES. NO DETERGENT ODOR OR TASTE REMAINS. NEF REVERSED, OK SDR SWAA2026070617983Heating Element · dirtyFAS REPORTED BURNING ODOR IN THE AFT GALLEY BY PLUG. CLEARED DEBRIS FROM AFT GALLEY DOOR AREA HEATER ELEMENT IAW AMM 21-45-00. NO DEFECTS FOUND WITH PLUG.SDR CALA2026070217519Oven · fireF/A REPORTS THAT PAPER CAUGHT FIRE IN OVEN 204. REMOVED RACKS FROM OVEN TO REMOVE PAPER AND ASHES FROM HEATING COIL AND MOTOR. WIPED OVEN DOWN. BURNT ODOR PRESENT AFTER OPS CHECK. REMOVED AND REPLACED FWD GALLEY OVEN 204 (G24) IAW AMM 25-34-00. OPS CHECK GOSDR CALA2026071617841Oven · contaminatedOVEN 412 SMELLS OF SMOKE. PERFORMED OPS TEST OF THE OVEN 412 REF AMM TASK 25-34-00-400-801-C3, ODOR OF SMOKE STILL REMAINS. MEAL CARRIER AND TRAYS CLEAN. FOUND FAN ASSEMBLY INSIDE OVEN COVERED WITH COKE BUILDUP. UNABLE TO CLEAN. REMOVED AND REPLACED OVEN 41SDR SCNA20260629264Oven · odorCHEMICAL, ELECTRICAL ODOR AFTER USE OF AFT GALLEY OVEN NR 3.SDR CALA2026062917372Oven · faultedOVEN 412 SMOKING OVEN RAN FOR 10 MINS ON GROUND, SMOKE SMELL RE-OCCURRED. FAULT CONFIRMED. OVEN 412 PLACED ON NEF. C/B PULLED AND COLLARED. TOMC PENDING TOMC CONTACTED. CREW DEBRIEFED AND ODOR INVESTIGATION CARRIED OUT IAW AMM 05-51-58, FAULT CONFIRMED TO FROSDR CALA2026062517322Oven · odorOVEN 204 EMITTS ACRID ELETRICAL SMELL WHEN HEATED. NO SMOKE OR FIRE. FOUND BURNED FOOD RESIDUE ON INSIDE OF OVEN DOOR. CLEANED AFFECTED AREA ON OVEN DOOR. OPS CHECKED OVEN AT 350 DEGREES FOR 20 MIN. NO BURN SMELL OR ODOR. ACFT OK FOR SERVICE.SDR CALA2026062517321Galley · odorAFT GALLEY COMPARTMENTS HAVE ROTTEN ODOR NEED CLEANING CLEANED & DISINFECTED 426/427 & 428 AFTGALLEY COMPARTMENTS IAW AMM 25-00-00-100-803.SDR CALA2026070617560Oven · odorFLIGHT ATTENDANTS REPORT NOXIOUS OVEN ODOR REPORTED AFT GALLEY OVEN R42. OPERATED OVEN WITH NO RACKS OR VISIBLE BURNT FOOD. ODOR PERSISTED. PULLED AND COLLARED CB. PLACE ON DEFERRAL.OKAY TO NEF 2522AD ODOR DOES NOT PERSIST UPON DEACTIVATION OF OVEN, PLACED ON SDR AALA202606250462Coffeemaker · sparksAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS SPARKS COMING OUT OF THE AFT RIGHT COFFEEMAKER IN FLIGHT. COFFEE MAKER CIRCUIT BREAKER PULLED. MAINTENANCE REPLACED THE COFFEMAKER PER AMM 25-35-15 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202606255120Oven · dirtyAIRCRAFT WAS NOT GROUNDED: OVEN #3 IN BUSINESS CLASS NEEDS A CLEANING, BURNING SMELL WHEN HEATED. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202606256504Oven · overheatedAIRCRAFT WAS NOT GROUNDED: OVEN NR 2 OVERHEATED WITH CORRESPONDING MOMENTARY ODOR OF SMOKE. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR DALA2026062303728Coffeemaker · odorFLIGHT ATTENDANTS IN FORWARD GALLEY REPORTED STRONG BURNING ODOR DESCENDING THROUGH APPROXIMATELY 5000'. AFTER LANDING ODOR CHANGED BUT STILL REPORTED AS ABMORMAL. REPLACED COFFEE MAKER IN FWD GALLEY IAW AMM 25-35. OPS CHECK GOOD. (LP 9077702 - AIRCRAFT WAS SDR CALA2026062917371Oven · odorWARMING OVEN SMELLS BAD. OVEN 425 SMELLS LIKE BURNT PLASTIC. INSTALLED INOP STICKER ABOVE AFT GALLEY OVEN 425, PULLED CB TO OVEN 425. OVEN IS NO HAZARD TO PASSENGERS.TOMC APPROVED, OK TO DEFER PER NEF 2510AU COMPLIED WITH NEF 2510AU. R & R AFT GALLEY OVEN 42SDR CALA2026071317725Oven · odorGALLEYS GALLEY G1C - OVEN AT GALLEY DEFECTIVE. VEN SMOKING WITH BURNING SMELL. 1ST OVEN ON THE RIGHT AS YOU LOOK FORWARD AND CLOSEST TO FIRST CLASS CABIN. FWD GALLEY, OVEN #2 INOP. REQUESTING MEL APPROVAL. G1 OVEN #2 CB PULLED AND COLLARED. APPROVED NEF 2520PSDR CALA2026062217212Unknown · odorOVEN AT BS 710 HAS ABURNING PLASTIC ODOR. OPERATED OVEN 710 SEVERAL TIMES CAN NOT DUPLICATE BURNING PLASTIC SMELL.SDR CALA2026062217210Oven · contaminatedBOTH FAS REPORTED BURNING RUBBER OR BURNIN PLASTIC SMELL IN FOR WARD GALLEY AFTER LANDING. PERFORMED INSPECTION OF FWD GALLEY AREA IAW FIM 21-00 TASK 830. FOUND MASKING TAPE FROM A TRAY ATTACHED TO OVEN 1. REMOVED TAPE AND CLEANED RESIDUE, OPS CHECK GOOD.SDR DALA2026061803632Oven · odorSTRONG ELECTRICAL SMELL IN THE AFT GALLEY ON DEPARTURE. ACCOMPLISHED QRH AND ISOLATED IT TO OVENS. AFT GALLEY C/B'S PULLED FOR OVENS. REPLACED OVEN #3. INSPECTED OVEN SLOT. CLEANED ADJACENT OVENS. RAN 20 MIN HOT CYCLE. NO FURTHER DEFECTS NOTED AT THIS TIME. SDR AALA202606205829Galley Mat · peelingAIRCRAFT WAS GROUNDED: FA REPORTS FLOOR IN AFT GALLEY PEELING UP WHERE IT GOES FROM CARPET TO VINYL CREATING TRIP HAZARD. (OPEN)SDR DALA2026061703623Oven · odorFA'S REPORTED ELEC BURNING SMELL AFT GALLEY. PILOT CONFIRMED SMELL & DISCOVERED CHILLER NR 2 AC PWR C/B TRIPPED. TURNED CHILLER SWITCH OFF & SECURED AFT GALLEY PWR FROM FLIGHT DECK. FOUND # 5 OVEN EMITTING ELECTRICAL SMELL. REPLACED NBR 5 OVEN. (LP 8422430 - SDR AALA202606174031Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFTER GALLEY CHILLER MAKING LOUD NOISES AND EMITTING BURNING ELECTRICAL SMELL. MAINTENANCE REPLACED CHILLER AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 25-34-51 WITH NO ODORS NOTED.SDR CALA2026061717149Oven · dirtyFWD GALLEY OVEN 204 BGAN SMOKING ON TAKEOFF. FA TURNED OVEN OFF S MOKE STOPPD. NOT DUE TO FOOD. HAD CREW PULL AFFECTED OVEN CB AS AN EXTRRRA SAFETY MEASURE. ADVISED NEED TO ACCOMPLISH SMOK/ORDOR FORM UPON ARRIVAL INTO IAH. FOUND GREASE AND FOOD RESIDUE BEHISDR CALA2026061517070Oven · faultySTRONG PLASTIC OR GAS LIKE BURNING ODOR WITH AFT OVEN 425 TURNED ON. FOUND OVEN TO BE AT FAULT C/W AMM UP TO PARAGRAPH C.F-1 AND C/W PARAGRAPH E, PLACING OVEN 425 ON MEL, DDP C/W. C/W AMM 05-51-26 FOUND OVEN TO BE AT FAULT C/W AMM UP TO PARAGRAPH C.F-1 ANSDR AALA202606104005Chiller · defectiveAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED ELECTRICAL BURN AND SMELL IN AFT GALLEY, TURNED THE CHILLER OFF AND THE SCENT WENT AWAY. WHEN A GALLEY CART WAS OPENED THE SMELL RETURNED. MAINTENANCE REPLACED THE CHILLER PER AMM 25-34-51 AND ACCOMPLISHED SDR DALA2026060803426Oven · odorON T/O ROLL BOTH PILOTS SMELLED ODOR THROUGH VENTS SMELLED LIKE COMING FROM OVEN, FLIGHT LEAD CONFIRMED SAME AND THAT THE OVEN HAD COME ON AFTER A POWER SWAP. SMELL DISSAPATED AND THEN RETURNED DURING DESCENT. REPLACED OVENS @FWD GALLEY 103 AND 104 PER A321
Back to JASC 2530