SDR JJBA20230612007Pump · inoperativeHYD 1 LOW QUANTITY ON EICAS IN FLIGHT. REMOVED AND REPLACED HYD PUMP ENG 1, REPLACED HYD PUMP HOSES. PERFORMED OPERATIONAL TEST AND LEAK CHECK OF ENGINE DRIVEN PUMP. OPS CHECK GOOD.SDR DXTA2023060587710Pump · defectiveHYD RES PRESS LOW AMBER CAS: WHEN SELECTING GEAR DOWN, THE "HYD PRESS LOW L AND R" AMBER CAS MESSAGE ILLUMINATED FOR 8-10 SECONDS. THE SYSTEM PRESSURE WENT FROM 3000 PSI TO 300 PSI AND THE DIGITS TURNED AMBER ALSO. THE LANDING GEAR DID NOT EXTEND RIGHT AWAY. ASDR IXXA20230530032Pump · unknownCREW ACARS MESSAGE, DURING CRUISE LEFT HYDRAULIC QUANTITY AND PRESSURE MESSAGE DISPLAYED. DIVERSION TO KCOF WITH EMERGENCY DECLARATION. LANDING WAS UNEVENTFUL WITH NO ADDITIONAL PRECAUTIONARY ACTIONS. ON ARRIVAL, AIRCRAFT GROUNDED FOR UNSCHEDULED MAINTENANCE. SDR DALA2023052504183Pump · leakingSHIP 3732 -MISC/DE/HYD- DUE TO LOSS OF B-SYSTEM HYDRAULICS. CORRECTIVE ACTION: FOUND A PACKING CUT ON THE #2 ENGINE DRIVEN PUMP (EDP) REPLACED B-SYSTEM EDP AND ELECTRIC PUMPS, INSPECTED ASSOCIATED FILTERS AND OPS CHECKED GOOD.SDR ANCF20230713017Motor · unserviceableDURING TAKE OFF ROLL, ENG 1 COMPRESSOR VANE ON ECAM, A LOW SPEED REJECTED TAKE OFF WAS PERFORMED. ENG 1 WAS SHUTDOWN DURING TAXI-IN. (13:45 UTC) REPLACEMENT OF THE BLEED VALVE FUEL GEAR MOTOR ASSEMBLY WAS PERFORMED IAW AMM: 75-31-10-000/400-002-A REV 64 OF 0SDR HALA2023052600114Unknown · unknownETOPS - FOUND #1 ENG, GREEN HYD. PUMP LEAKING. REMOVED AND REPLACED #1 ENG, GREEN HYD. PUMP PER AMM 29-11-51. LEAK CHECK GOOD. OK FOR SVC.SDR M17F2023060500064Pump · leakingHYD PRI PUMP L - 291 152 41.SDR SWAA2023052250881Pump · faultyLOSS OF SYSTEM B HYDRAULIC.<[01] REMOVED AND REPLACED B SYSTEM EMDP PER AMM 29-11-21; LEAK AND OPS CHECK GOOD;[02] CW FILTER CHANGE;[03] REF LP 0472836E FOR CLOSING ACTION; ITEM REMAINS OPEN;[04] REMOVE AND REPLACE 'B' EDP PER AMM 29-11-11. REMOVE AND REPLACE SDR DALA2023051803951Unknown · unknownSHIP 9567 -HYD/DE- THE FLIGHT CREW NOTICED A LOSS OF HYDRAULIC FLUID INDICATION WITH THE LEFT SYSTEM. THE QRH WAS COMPLIED WITH AND THE LEFT ENGINE DRIVEN HYDRAULIC PUMP WAS SHUTDOWN. AN EMERGENCY WAS DECLARED DUE TO THE LOSS OF THE LEFT SYSTEM HYDRAULICS WHILSDR ASAA2023042643007Pump · leaking#2 ENG (EDP) HYD PUMP LEAKING HYDRAULIC AT SUPPLY CASING. GROUNDED - YES. REMOVED AND REPLACED #2 ENG (EDP) HYD PUMP REF B737-800 AMM 29-11-11-400-801-001.SDR CALA2023042401239Pump · failedENG 1 LOW PRESSURE LIGHT LIGHT ON LIGHT CAME ON DURING CLIMBOUT PASSING APPROX 15K FEET UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. ROTABLE PARTS ENTRY MADE. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1406150 SNSDR CALA2023041901152Check Valve · failedECAM, HYD Y RSVR LO LVL. FOLLOWED CHECKLIST, SHUT DOWN #2 ENGINE PUMP. DID NOT GET YELLOW SYSTEM LOW PRESSURE MSG PRIOR TO SHUTTING PUMP OFF. FOUND GREEN MAIN HYDROLIC POWER CHECK VALVE ON PTU TO BE LEAKING. REMOVED AND REPLACED CHECK VALVE. REFF AMM 29-11-15 SDR LR7A2023033003284Pump · inoperativeDURING SCHEDULED FLIGHT UTILITY SUCTION BOOST PUMP LIGHT ILLUMINATED. DUMPED FUEL IAW QRH / REPLACED SUCTION BOOST PUMP ASSY IAW SMP 581 29-11. LP# 50721.SDR GTIA2023031637047O-Ring · leakingDURING FLIGHT LOST YELLOW SYSTEM HYDROLIC SYSTEM FLUID PERFORMED ECAM ACTION AND COME FOR LOSS OF YELLOW SYSTEM FLUID (YELLOW FLUID VERY LOW)-FOUND UNION 3093GM LEAKING. R/R O-RING IAW AMM 29-13-15. OPS CHECK / LEAK CHECK GOOD. NO FURTHER DEFECTS NOTEDSDR ANCF20232403007Pump · unserviceablePILOT REPORT
11-MAR-23 WO 17'202'358 => ELEC HYD BLUE PUMP OVERHEAT
ACTIONS TAKEN
11-MAR-23 WO 17'202'358 => PERFORM TSM 29-12-00-810-806-A.
12-MAR-23 WO 17'202'358 => DUE TO ELEC HYD BLUE PUMP OVERHEAT IAW TSM 29-12-00-810-806-A REV 63 WAS REMOVED ANSDR 4DPA2023022300001Pump · leakingISSUE- CREW REPORTED THEY RECEIVED A HYD2 LO QTY ADVISORY FOLLOWED BY ENG2 HYD PUMP FAIL. AND RETURNED TO DAL. CORR ACTION- MX R&R'D ENGINE DRIVEN PUMP ALL OPS AND LEAK CHECKS GOOD.SDR 2023F00065Pump · failedQRF TO SLCB. AFTER TAKOFF HIDRAULIC ENGINE DRIVEN PUMP LOW PRESSURE ILLUMINATED. CORRECTIVE ACTION: REMOVED AND REPLACED HY SYSTEM "A" IAWAMM29-15-12. REPLACED EDP CASE DRAIN FILTER ELEMENT IAW AMM 29-15-91.SDR AALA202302164259O-Ring · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED UPON ARRIVAL TO DFW: WHILE IN CRUISE YELLOW HYDRAULIC SYSTEM ENGINE 2 PUMP LOW PRESSURE MESSAGE ILLUMINATED. YELLOW HYDRAULIC SYSTEM QUANTITY DISPLAYED AT AMBER BOX AND EVENTUALLY QUANTITY BLED OUT COMPLETELY. SDR HALA2023012700016Pump · inoperativeETOPS - BTB: DURING TAXI OUT ECAM MESSAGE HYD ENG2 PUMP LO PR FOLLOWED ECAM ACTIONS. STATUS HYD ENG2 Y PUMP INOP. REMOVED AND REPLACED ENG 2 YELLOW HYD PUMP PER AMM 29-13-51 OPS AND LEAK CHECK GOOD OK FOR SVC.SDR SWAA2023012594574Pump · failedLOSS OF HYDRAULIC SYS A. REPLACED NR 1 ENGINE HYDRAULIC PUMP & PRESSURE LINE PER MM29-11-11SDR CALA2023011800148Pump · faultedENG 1 LOW PRESS IN FLT QTY MINS LATER WENT TO 20 PERCENT WHILE PERFORMING HYD FLUID TRANSFER FROM SYSTEM B TO A FOUND REMOVED #1 ENG EDP REF AMM 29-11-11 PARTS USED: INSTALLED #1 ENG EDP REF AMM TASK 29-11-11-400-801-001 FROM STEP COMPLETED STEP I OF AMM 29-11SDR FDEA202301150114Pump · misinstalledCREW REPORT ON DEBRIEF THAT C HYD PRIM 2 MESSAGE MOMENTALLY CAME ON WITH GEAR OPERATION. REMOVEDAND REPLACED CENTER HYD PRIM NR 2 PUMP IAW AMM 29-11-02-4. LEAK AND OPS CHECKED GOOD. WAS INFORMED THAT WHILE REPLACING THE HYD PUMP THEY NOTICED THAT THE PUMP WSDR 2023F00032Pump · overheatedABORTED TEAKEOFF. DURING TAKEOFF BEFORE 80 KTS WE HAD THE MESSAGE HYD OVERHEAT. CORRECTIVE ACTION: REPLACED HYD EMDP. TEST NORMAL.SDR SCNA20230117041Pump · low pressureHYDRAULIC SYSTEM A ENGI 1 LOW PRESSURE LIGHT IILLUMINATED FOLLOWED BY LOSS OF HYDRAULIC GUQNTITY IN FLIGHT IN SYSTEM A. RAN QRH AND LANDED UNEVENTFULLY OVERWEIGHT. REMOVED AND REPLACED #1 ENG HYD PUMP PER AMM 29-11-400-801-001 AND 29-11-11-000-801-001. REPLSDR DALA2023010900113Pump · leakingHYD/MISC/DE - DUE TO GREEN SYSTEM HYDRAULIC LOSS. FOUND #1 ENGINE EDP OUTLET LINE LEAKING AT CLAMP, REPLACED SAME. DURING LEAK CHECK FOUND TUBE PRESSURE SWITCH LEAKING FROM THE B-NUT. R/R PRESSURE SWITCH LINE. OPS CHECK GOOD.SDR JJBA20230109007Pump · inoperativeHYD 2 LOW QTY ON EICAS. REMOVED #2 ENGINE DRIVEN HYD PUMP. REMOVED #2 ENGINE DRIVEN HYD PUMP MAGENTIC CARBON SEAL ASSEMBLY. INSTALLED #2 ENGINE DRIVEN HYD PUMP. INSTALLED #2 ENGINE DRIVEN HYD PUMP MAGNETIC CARBON SEAL. OPS AND LEAK CHECK SAT.SDR ABXA20221230159Pump · low pressureL HYD ACMP HAS LOW PRESSURE DURING TAXI. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE REMOVED AND REPLACED L ACMP PER AMM 29-11-01 LEAK CHK OK. AIRCRAFT RETURNED TO SERVICESDR 2023F00008Pump · faulted#1 STBY HYD PUMP HOT LIGHT ILLUMINATED IN FLIGHT. REPLACED LH STBY JPUMP WITH REPAIRED UNIT.SDR HALA20221229322Pump · brokenETOPS- NEED TO REMOVE AFT HYD PUMP FOUND RECEPTACLE ON PUMP CRACKED. REPLACED THE AFT HYD PUMP.SDR 7C7A2022122980050Pump · overtemp#1 STBY HYD PUMP HOT LIGHT ILLUMINATED IN FLIGHTSDR 7C7A2022122800049Warning Light · false activation#1 STANDBY HYDRAULIC PUMP HOT LIGHT INTERMITTENTLY FLASHING ON TAXI. REPINNED IAW AMM 29-11-17.SDR DALA2022122788424Pump · leakingLOSS OF GREEN HYDRAULIC SYSTEM REQUIRING ALTERNATE GEAR EXTENSION. FOUND NR 1 ENG EDP LEAKING. REPLACED EDP. REPLACED NR 1 ENG G HYD CASE DRAIN, LP AND HP FILTERS. REPLACED NR 2 ENG HYD PUMP. REPLACED GREEN AUX PUMP. FLUSHED SYS. R & R WATER SEPARATOR AIR FISDR YENA2022122301294Pump · failedFLT#44, LGW-JFK. (ETOPS) 'DURING CRUISE HYD Y RSVR LOW LVL ECAM EDP SELECTED OFF WITHIN 5 MINUTES; UPON INSPECTION FOUND #2 ENG EDP DRAIN PORT LEAKING. REMOVED AND REPLACED #2 ENG EDP PER AMM 29-13-51. REF LOG PAGE 3331596, ITEM 2 (REF LP 3331593 ITEM 1 ACCOMPSDR 7C7A2022122700044Pump · faultedNR 1 STBY HYD PUMP HOT LIGHT INTERMITTENLY FLASHING ON TAXI. T/S STBY HYS PUMP, FOUND HARD FAULT ON STBY HYS PUMP OINS A/B OVERTEMP SWITCH MOVED TO PIN E/F OVERTIEMP SWITCH IAW AMM 29-11-17SDR F3LA2022201200169Warning Light · false activationBLUE ELEC HYD PUMP FAILED ON PUSHBACK. FOLLOWED TSM 29-12-00-810-804-A UP TO STEP 3, B. NO FAULTS NOTED. OPS CHECK GOOD PER AMM 29-2-00-710-001. A/C OK FOR SERVICE.SDR ASAA2022121641172Pump · leaking#2 ENGINE OIL LEAK ON SHUTDOWN AT HYD PUMP DRIVE PAD REF. ASA MIG-2C# 40-0038356 ITEM #3. GROUNDED - YES. REMOVED AND REPLACED ENG #2 HYD PUMP AND SEALOL SEAL PER B737-800 AMM 29-11-11-400-801 AND AMM 72-60-00-400-801-F00.SDR DXTA2022121476120Seal · leakingDURING CRUISE, AT FL430 HYD VOLUME LOW AMBER CAS ILLUMINATED. HYD FLUID CAN BE SEEN DRIPPING FROM RT ENGINE DRAIN MAST. INSPECTED RT ENG HYD PUMP & FOUND FLUID FROM DRAIN MAST ON BOTH PAD DRAINS. CHECKED SYS VOLUME, FOUND 190 CI, PRESSURIZED SYS WITH AUX PUSDR CALA2022120803345Pump · failedSUSPECT LEFT ENGINE DRIVEN HYDRAULIC PUMP FAILURE. PUMP REPLACEMENT REQUIRED. REPLACED LEFT EDP PUMP ASSY IAW AMM 29-11-05-404-029-005 AND PUMP FAILED OPERATIONAL TEST. PERFORMED FIM 29-11 FAULT TREE 805 AND PER SHEET 2 BLOCK 27, SWAPPED OPERATIONAL PRESSURISDR CALA2022120703318Pump · faultedHYD 1 ENG PUMP LOW PRESSURE MAINTAINED AT 3000 PSI. REMOVED ENG #1 EDP, COMPLETED REMOVAL OF ENG 1 EDP AND INSTALLED NEW EDP ON ENG 1. REPLACED #1 ENG AGB ROTATING SEAL FOR HYD PUMP. INSTALLED #1 HYD PUMP. INSTALLED NEW MAGNETIC CARBON SEAL. OPS CHECK GOOD.SDR AALA202301108820Pump · faultedAIRCRAFT WAS GROUNDED: RAN HYDRAULIC PRESSURE PRIMARY RIGHT CHECKLIST AT CRUISE. UPON COMPLETION OF CHECKLIST NOTED RIGHT HYDRAULIC QUANTITY ZERO. EMERGENCY DECLARED INTO MIA. REMOVED AND INSTALLED NEW ENGINE DRIVEN PUMP RIGHT IAW AMM 29-11-05.SDR F3LA2022120700159Pump · leakingFUMES NOTED, FUMES CHECK LIST FOLLOWED. REMOVED AND REPLACED THE NR 2 ENG HYD PUMP IAW AMM 29-13-51-000-809-A/400-809-A USING T/W F9TAB1092C AND T/W F9TAB5836C. NO FUMES OR ODORS NOTED AT THIS TIME IAW TSM 05-50-00-810-831-A. OPS CHECK GOOD. ACFT OK TO CONTISDR YENA2022122101278Pressure Switch · failedFLT#20, LHR-JFK. (ETOPS) 'ON HYD PAGE ENG 2 EDP SHOWS IN LINE GREEN WITH HYD ENG 2 PUMP PUSH BUTTON SWITCH IN AUTO .- DEPRESSUIZTION FUNCTION (ENGINE DRIVEN PUMP SYS - DEPRESS FUNC); REF AWM 29-13-02, CHK WIRING AT FIN 3074GD SHIELDING AND WIRE. THE CONTINUITSDR AALA202212065495Pump · leakingAIRCRAFT WAS GROUNDED: PRIOR TO DESCENT MASTER CAUTION HYDRAULIC A ENGINE 1 LOW PRESSURE LIGHT ILLUMINATED. HYDRAULIC A PRESSURE AT 20% PERFORMED QUICK REFERENCE HANDBOOK LOSS OF SYSTEM A CHECKLIST. EMERGENCY WAS DECLARED INTO DFW. TROUBLESHOOTING FOUND HYDRAUSDR CALA2022113003259Circuit Breaker · trippedHYD B SYS LOW PRESSURE ECAM ON BLUE QUANTITY. ACCOMPLISHED INSPECTION CHECK OF BLUE HYD SYSTEM. NO LEAKS DETECTED, HYD RESERVOIR PRESSURE WITHIN THE LIMITS, ONLY FOUND B HYD ELEC PUMP CIRCUIT BREAKER TRIPPED, PUSHED IN AND NO OTHER FAULTS FOUND.SDR SWAA2022112976064Pump · low pressureENG. 1 HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED IN FLIGHT. / [01] REMOVED AND REPLACED #1 ENGINE; ENGINE DRIVEN PUMP PER AMM 29-11-11. OPS AND LEAK CHECK GOODSDR HALA2022112300298Pump · leakingETOPS-DURING PDC, FOUND #1 ENG GREEN ENGINE-DRIVEN HYDRAULIC PUMP LEAKING. REMOVED AND REPLACED #1 ENG GREEN ENGINE DRIVEN HYDRAULIC PUMP PER AMM 29-11-51. OPS TEST GOOD. LEAK CHECK GOOD. OK FOR SVC. P/N OFF/ON: 3022053-001 S/N ON: G0510072 S/N OFF: G0420503SDR HALA2022112100294Pump · leakingETOPS-#1 ENG FWD HYD PUMP NOTED WITH EVIDENCE OF LEAKS AT MULTIPLE LOCATIONS ON THE PUMP CASE AND BROKEN / PROTRUDING MATING FACE GASKET. REMOVED FWD (BLUE) HYD PUMP, CLEANED, AND REPLACED SHAFT SEALS AND MOUNTING GASKET AND INSTALLED NEW HYD PUMP REF A330 AMMSDR CALA2022111703161Pipe · leakingECAM CAUTION MESSAGE - Y RSVR LO LVL MESSAGE INOP - HYD HYD YELLOW SYSTEM LO MASSIVE LEAK SOMEHERE ON TOP OF THE #2 ENG UNDERNEATH THE PYLON. FOUND HYD PIPE CUT AND LEAKING HYD FLUID AT DOWNSTREAM OF T/R CHECK OF THE YELLOW HYD SYSTEM PER AMM 29-13-00-710-002-SDR AALA202211165954Pump · leakingAIRCRAFT WAS GROUNDED: ON DOWNWIND AT DFW PLANE WENT INTO MANUAL REVERSION. SYSTEM B WENT TO 60%, SYSTEM A WAS NORMAL. GEAR WAS EXTENDED MANUAL AND LANDED WITH FLAP 5 ON THE FLAP HANDLE, INDICATOR SHOWED 5. BRAKE PRESSURE SHOWED 2500 APPROXIMATELY ON FINAL THESDR CALA2022111403134Pump · low pressureENG 1 LOW PRESSURE LIGHT LIGHT ON DEBRIEF CREW ON ARRIVAL, A HYD SYSTEM ON #1 ENGINE SHOWS HYD PUMP ME# 29-2910-9-0003 AND INSTALL KIT ME# 29-2910-3-0012 UPON FILLING A SYSTEM HYD RESEVOIR. FLUID STREAMING OUT OF HYD QUANTITY 18%, LEAK FROM ENGINE TO INVESTIAG