JASC 3810
Service difficulty reports · 418
Reports filed under 3810 · Potable Water System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3810' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA20131221247Water Heater · failedCREW REPORTED ELECTRICAL ODOR NEAR FOWARD LAVATORY ENROUTE. TROUBLESHOOTING IAW FIM TASK 21-20-00 AND 25-40-00, ODOR COMING FROM FWD LAV WATER HEATER. R & R FWD LAV WATER HEATER IAW AMM 38-12-01. OPS CHECK GOOD.SDR CALA2013121693746Gasket · damagedFOUND WATER LEAK AT WATER FILTER HOUSING IN FWD GALLEY. INSTALLED NEW GASKET ON TOP OF WATER FILTER & INSTALLED TOP FOR WATER FILTER HOUSING IN FWD GALLEY. FOUND NO LEAKS.SDR CA131209003Water System · leaking(CAN) ADIVERTED DUE TO A SUSPECTED POTABLE WATER LEAK. MAINTENANCE CARRIED OUT THE FOLLOWING ACTIONS BEFORE THE AIRCRAFT WAS SUCCESSFULLY RETURNED TO SERVICE. FOUND POTABLE WATER DRAIN IN AFT GALLEY R/H SIDE IN ON POSITION CAUSING ALL POTABLE WATER TO DRAIN OUSDR CALA2013111893020Relief Valve · noisyAFT GALLEY MAKING A VERY LOUD CHATTER NOISE APU RUNNING & BLEED ON. DETERMINED TO BE AIR RELIEF VLV BEHIND AFT GALLEY COFFEEMAKER. ACCOMPLISHED BLEED PROCEDURE IAW MT 38-005, NOISE STOPPED.SDR SIMA20131103001Unknown · odorPASSENGERS AND F/A COMPLAINING OF FOUL ODOR EMANATING FROM COFFEE SUSPECT FORWARD POTABLE WATER TANK CONTAMINATED. FLUSHED AND SERVICED FORWARD POTABLE WATER TANK IAW AMM 38-11-00. NO DEFECTS NOTED.SDR CALA2013103192544Drain · cloggedWATER DRAINING OUT OF THE BELLY DRAIN HOLE. CHECKED AFT GLY DRAINAGE OPERATION IAW AMM & APPEARS OPERATION IS NORMAL. DOOR DRAINS & AFT FLOOR DRAIN COME OUT OF BELLY WEEP HOLE BY THE AFT DRAIN MAST & LAVATORY SVC PANEL. GALLEY SINK COMING OUT OF DRAIN MAST.SDR CALA2013092791515Valve · openPOTABLE WATER ISSUE, FLIGHT DIVERTED. FOUND REFILL VALVE OPEN A LITTLE, RESEATED REFILL VALVE. SERVICED WATER OPERATIONS CHECKED OKAY.SDR USAA2013082900003Water Heater · malfunctionedACFT LEFT AFT LAVATORY HAS A SLIGHT ELECTRICAL SMELL. TURNED WATER HEATER OFF AS PRECAUTIONARY AND ISOLATED, ALL SYSTEMS NORMAL. REPLACED LAV D WATER HEATER PER AIRBUS MAINTENANCE MANUAL 38-12-16 PB 0401.SDR CALA2013082290661Nut · looseONE INCH STANDING H2O LT SIDE MID CABIN LAV 111. RE-SECURED LOOSE WING NUT TO WATER FILTER IN LAV 2R.SDR CALA2013082290674Compressor · vibrationCREW REPORTS H20 COMPRESSOR VIBRATES. COMPLIED WITH MEL 3810B, CB K 21 IS COLLARED. PLACARD IS ON WATER GAUGE, DF123. ALL FAUCETS OPERATE NORMALLY WITH BLEED PRESSURE. REPLACED AIR COMPRESSOR PER AMM, OPS CHECKED OKAY.SDR CALA2013081390416Cable · frayedFOUND THE PRE SELECT FILL OVERFILL CABLE BAD. THE CABLE END IS FRAYED AND CABLE IS VERY LOOSE. WATER SERVICE IS NORMAL FROM FWD WATER SERVICE PANEL (ELECTRIC) PROBLEM IS WITH AFT (MANUAL CABLE) SERVICE PANEL. COMPLIED WITH MEL. OPS CKS GOOD.SDR AALA20130815009Manifold · leakingA CEILING PANEL WAS FOUND LEAKING WATER DURING THE ACCEPTANCE CHECK FOR THE NEW AIRCRAFT. IT WAS DISCOVERED THAT A POTABLE WATER DRAIN MANIFOLD AT STATION 813 LBL 44 LOCATED ABOVE THE BAR FORWARD OF BUSINESS CLASS SEAT 5D WAS DEFECTIVE DUE TO PIN HOLE LEAKS SDR AALA20130815008Manifold · leakingMULTIPLE CEILING PANELS WERE FOUND LEAKING WATER DURING THE ACCEPTANCE CHECK FOR THE NEW AIRCRAFT. IT WAS DISCOVERED THAT FOUR POTABLE WATER DRAIN MANIFOLDS THROUGHOUT THE AIRCRAFT WERE DEFECTIVE DUE TO PIN HOLE LEAKS IN THE TUBING. THE FOUR POTABLE WATER MASDR UALA2013071604986Valve · faultedLOW WATER PRESSURE THROUGH OUT ACFT ON DEPARTURE. FOUND SYS OVERFILLED. DRAINED, NO HELP. FOUND PRESELECT OVERFILL VALVE AT FAULT, MANUALLY ACTUATED CLOSED SYS, PRESSURE RESTORED. PREVIOUS HISTORY NEEDS NEW VALVE. REPLACED PRESSURE RELIEF VALVE IAW AMM ASDR UALA2013071504930O-Ring · failedLARGE AMOUNTS OF WATER LEAKING FROM UNDER THE AIRPLANE. FOUND POTABLE WATER TANK DISTRIBUTION LINE O-RING BLOWN. REPLACED O-RING, OPS AND LEAK CHECKED GOOD.SDR UALA2013071204872Gauge · inaccurateWATER TANK GAUGE IS NOT ACCURATE. FILLED AND DRAINED AND FILLED AGAIN POTABLE WATER TANK. FOUND GALLEY INDICATOR READING INCORRECTLY. REPLACED FWD GALLEY QTY IND IAW AMM. BOTH GALLEY AND SERVICE PANEL IND. READING ACCURATELY.SDR UALA2013070904765Valve · leakingDURING PRE-FLT, FLUID DRIPPING FROM PORT UNDER AFT CARGO BAY. DRAIN PORTABLE WATER TANK AND WATER STOPPED. PORTABLE WATER SYS INOPERATIVE FOR ENTIRE ACFT. SECURED DRAIN-FILL VALVE, FILLED POTABLE WATER AND PRESSURIZED WATER SYS, NO LEAKS NOTED.SDR UALA2013070804731Line · leakingTHREE TO FOUR CUPS OF WATER FLOWED FROM UNDER COFFEEMAKER IN AFT GALLEY EVERY TIME AIRCRAFT STOPS OR SLOWS. FOUND EVIDENCE OF LEAK UNDER INBOARD COFFEEMAKER. REMOVED AND CLEANED AREA AND TIGHTENED WATER LINE THAT APPEARED TO BE LOOSE. INSTALLED COFFEEMAKER ASDR 2013FA0000381Line · leakingSHORTLY AFTER TAKEOFF THE HOT WATER LINE TO THE AFT SINK WAS DISCOVERED LEAKING.SDR UALA2013052203538Gauge · faultyPOTABLE WATER GAUGE INOPERATIVE. DOES NOT READ ACCURATELY. READING 22 WHEN TOLD FULL "35".SDR 2013FA0000210Line · disconnectedCOFFEEMAKER WAS REPORTED BY CUSTOMER TO HAVE FAILED AND LEAKING WATER. ON FURTHER INVESTIGATION NOTICED THAT ONE OF THE WATER LINES HAD COME OFF AND AN ELECTRICAL CONNECTOR WAS MELTED AND CHARED.SDR UALA2013040102079Seal · brokenAFT GALLEY WATER EXT HAS BROKEN SEAL. REPLACED SEAL.SDR DALA13014221612Compressor · smokeFOUND SMOKE AND ELECTRICAL SMOKE IN THE AFT PAX COMPARTMENT. FOUND THE SMOKE COMING FROM THE POTABLE WATER COMPRESSOR AND CONFIRMED THE SMOKE DISAPPEARED AFTER THE COMPRESSOR CIRCUIT BREAKER WAS PULLED. OPENSDR UALA2013040102062Water System · contaminatedAFT GALLEY LOUD CHATTERING NOISE AFTER APU BLEED TURNED ON. BLEED AIR OUT OF AFT GALLEY WATER. CHATTERING STOPPED. OK FOR SERVICE.SDR UALA2013031401536Valve · openNO POTABLE WATER IN ENTIRE ACFT, FLIGHT DIVERTED. FOUND POTABLE WATER FILL VALVE PARTIALLY OPEN, CYCLED FILL VALVE OPEN AND CLOSED, CHECKED ALL LAVATORIES AND GALLEYS FOR WATER PRESSURE.SDR BKEA2013FA0000162Line · unsecureAPPROX 4 AND A HALF HOURS INTO FLIGHT, WHITE ADVISORY ANNUNCIATION AUTOPILOT FAIL OCCURRED. AUTOPILOT SWITCHED FROM CHANNEL 1 TO 2. MINUTES LATER, SAME ANNUNCIATION OCCURRED AND AUTOPILOT SWITCHED FROM CHANNEL 2 TO 1. ABOUT TEN MINUTES LATER, YELLOW CAUTIOSDR UALA2013021800985Line · constrictedNO WATER PRESSURE WITH APU & RT ENGINES RUNNING. FOUND PNEUMATIC FLEX LINE CONSTRICTED. NO AIR PRESSURE GOING TO WATER TANK. REMOVED PNEUMATIC FLEX LINE. INSTALLED NEW FLEX LINE AND CLAMPS.SDR UALA2013021400880Valve · leakingAFT WATER DRAIN LINE CONTINUES TO DRIP AFTER VALVE IS CLOSED. 643-0044 ON AOM V5969. REPLACED FILLING - DRAIN WATER VALVE, CHECK NO LEAKS.SDR UALA2013021200832Transmitter · inoperativeNO WATER PRESSURE THROUGHOUT ACFT QTY SHOWS 150 GAL AND HOLDING STEADY. NO AIR COMING FROM FAUCETS WHEN OPENED. ALL LAVATORIES DRY FLUSHING. REPLACED WATER QTY TRANSMITTER AND PRESSURE SWITCH, OPS CHECKED GOOD. NO LEAKS NOTED.SDR UALA2013021200842Valve · failedTWO HOURS FORTY FIVE MINUTES INTO FLIGHT, LOST WATER PRESSURE FOR ALL FAUCETS. REMOVED AND REPLACED POTABLE WATER FILL VALVE PER AMM. NO LEAKS NOTED. WATER OPS NORMAL THROUGHOUT AIRCRAFT.SDR UALA2013012900538Clamp · brokenFOUND CLEAR WATER LEAKING FROM LEFT SIDEWALL OF FWD CARGO BAY AT BS 800. FOUND Y FITTING CLAMP BROKEN ON POTABLE WATER DRAIN LINE 478W3150-108 INSIDE LEFT SIDEWALL AT STA 800. REPLACED CLAMP ASSY PCN 023-1516, SVC POTABLE WATER, OPS CHECKED NORMAL. NO LEAKISDR CA130123003Coupling · leaking(CAN) DURING FLIGHT THROUGH 35,000 FT. THE CREW FOUND THE PRESSURIZATION TO BE FLUCTUATING AND THE OUTFLOW VALVE TO BE UNRESPONSIVE. DURING A DESCENT TO SEE IF THE ISSUE WOULD BE RESOLVED, THE OUTFLOW VALVE WENT TO FULL OPEN AND THE ACFT DECOMPRESSED. THE CRSDR UALA2013010700076Hose · leakingLARGE AMOUNT OF POTABLE WATER LEAKING OUT OF AFT CARGO COMPT. REPLACED HOSE ASSY, AND SERVICED POTABLE WATER SYSTEM, CHECKED NO LEAKING FOUND.SDR UALA2012112606790Water System · contaminatedLOUD VIBRATION IN AFT GALLEY. COULD BE WATER PUMP. STARTED WHEN SYS PRESSURE CAME UP. FOUND A LOT OF AIR IN AFT GALLEY SYSTEM. REMOVED BOTH COFFEEMAKERS AND ALL FAUCETS IN AFT GALLEY AND LAVS, NOISE WENT OFF AFTER ABOUT 4-4 SECONDS. INSTALLED BOTH COFFEEMSDR UALA2012111206474O-Ring · leakingWATER COMING OUT OF 4 DRAIN HOLES LOCATED BETWEEN FWD CARGO COMPT AND WING ROOT. REPLACED POTABLE WATER TANK LOWER SERVICE LINE FITTING O-RING. PRESSURE LEAK TEST REF AMM 38-10-00-614-001A CHECK GOOD. PERFORMED WATER CLEAN UP REF GNMM 4-06-004.SDR UALA2012103106283Drain Valve · stuckCREW REPORT: UNABLE TO FILL POTABLE WATER. FWD DRAIN VALVE STUCK OPEN. DURING TROUBLESHOOTING FOUND FWD WATER DRAIN VALVE FROZEN. CURRENTLY WORKING CLOSEUP. REMOVED AND REPLACED FWD DRAIN VALVE PER MM. LEAK CHECK GOOD. VALVE STILL OPERATES STIFF, SUSPECTSDR UALA2012103006249Cable · out of rigNO WATER PSI ON A-C CHRONIC PROBLEM. PER MEL PLACARD 38008 ENSURE POV IS CLOSED. COMPLIED WITH REQUIREMENTS IN MEL 3810AR. ADJ- :ADJUSTED RIG OF PRESELECT OVERFLOW VALVE CABLE, OPERATION CHECK NORMAL. WATER PRESSURE NORMAL IN ALL LAVS AND GALLEY.SDR UALA2012102306073Actuator Cable · brokenAFT DRAIN VALVE CONTROL CABLE HOUSING IS BROKEN. ACCOMPLISHED REMOVAL AND INSTALLATION OF AFT DRAIN VALVE ACTUATOR CABLE (PCN:643-1543) PER AMM. OPS CHECK GOOD. OK FOR SERVICE.SDR UALA2012102306088Valve · defectivePOTABLE WATER INOP IN ENTIRE AIRCRAFT. HOUSTON REPORTEDLY SERVICED SYSTEM BEFORE DEPARTURE. DRAIN VALVE FROZEN IN OPEN POSITION, UNABLE TO RETAIN WATER. TRIED ACT NO HELP. REPLACED FILL VALVE (643-1474).SDR UALA2012101805964Timer · out of adjustMID RIGHT LAV SINK WATER WON'T SHUTOFF. WATER SHUTOFF VALVE FAILED. REPLACED WATER SHUTOFF VALVE TO ENABLE DEFFERAL. REQUIRES NEW FAUCET VALVE OR TIMER, NO TIME TO TROUBLESHOOT. PER MEL DEACTIVATED WATER HEATER AND BOARDED HAND SANITIZER. ADJUSTED HYDRAULSDR UALA2012100505656Compressor · failedBURNING SMELL EVIDENT AROUND ZONE 480-600 LWR FWD CARGO AREA. ALL MEC AREA ELECTRICAL AND RACKING INSPECTED NIL DEFECTS FOUND SMELL TRACED TO FWD CARGO FUME BARRIER ON INSPECTION OF AREA POTABLE WATER COMPRESSOR FOUND FAILED & OVERHEATING COMPRESSOR DECATIVATSDR 2012F00197Water Heater · shortedENROUTE, CABIN ATTENDANT DETECTED AND SAW SMOKE COMING FROM THE GALLEY AREA. CONFIRMED LOCATION OF SMOKE AND PULLED ALL CIRCUIT BREAKERS TO GALLEY AND CAPTAIN SHUTOFF ALL GALLEY AND CABIN POWER. DECLARED AN EMERGENCY AND LANDED. TROUBLESHOT AND INSPECTED, FSDR UALA2012090705057Tape · burnedPOTABLE WATER LINE HEAT TAPE BURNT ON TOP OF TEE STA 1380 RBL 0. REPLACED HEATER TAPE, OPS CHECK GOOD.SDR UALA2012081304364Gauge · inoperativePOTABLE WATER GAUGE CHECKED FULL BEFORE DEPARTURE. FLIGHT ATTENDANT NOTICED LATER THAT GAUGE WAS AT ZERO. REPLACED MISSING SCREW TO GAUGE.SDR UALA2012081304397Gauge · inoperativePOTABLE WATER GAUGE CHECKED FULL BEFORE DEPARTURE. FLIGHT ATTENDANT NOTICED LATER THAT GAUGE WAS AT ZERO. DEFERED FOR TIME PER MEL VERIFIED TANK FULL.SDR R61A201207150370Potable Water · contaminatedPOT WATER FROM SINK AND COFFEEMAKERS RELEASES FUMES THAT BURN THROAT AND NOSE. MAINTENANCE PERFORMED POTABLE WATER SANITIZATION IAW EMB 175 J/C R12-14-01-670-810A. WATER IS CLEAR AND NO LONGER CONTAINS ODOR. PLACED POTABLE WATER TANK ON MEL 38-10-00-2.SDR CA120713004Water System · failed(CAN) THE ACFT LOST ALL WATER PRESSURE WITH THE TANKS SHOWING LESS THAN HALF FULL. A PHONE PATCH WITH MAINTENANCE CONTROL WAS CONDUCTED AND A WATER LEAK WAS SUSPECTED. THERE WERE NO OTHER ASSOCIATED FAILURES SO THE FLIGHT ELECTED TO RETURN WHERE AN OVERWEIGHTSDR UALA2012071203774Potable Water · contaminatedPOTABLE WATER HAS AN ODOR AND TASTES ODD. SUSPECT MOLD. COLD, HOT, AND THRU COFFEEMAKER ALL AFFECTED. WATER SYSTEM DRAINED. ACCOMPLISHED POTABLE WATER IONIZATION IAW EQ8006 USING MM 38-10-00-201.SDR UALA2012062903492Indication Sys · malfunctionedPOTABLE WATER SHOWS 140 GALLONS AND NO WATER COMING OUT OF FAUCETS DURING LAST HOUR OF FLIGHT. ON ARRIVAL, POTABLE WATER SHOWING,110 GALLON. SERVICED TO MAXIMUM, INDICATION SHOWING 140 GALLON, MAXIMUM. POTABLE WATER SYSTEM OPS CHECK NORMAL ON GROUND WITH APSDR SWIA201231041Water System · dirtyTHE COFFEE POTS GAVE OFF A DISTINCT ODOR OF AN ELECTRICAL BURNING SMELL. (FLT 5306) PERFORMED A SANITIZATION OF THE AIRCRAFT WATER SYSTEMS.
Back to JASC 3810