JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA03SH125Beam · corrodedSHV - DURING C-CHECK THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED DAMAGE AND REPLACED AFFECTED BEAM IAW EMB 135 SRM 51-40-02. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA03SH122Butt Strap · corrodedSHV- DURING C-CHECK LEFT HAND BUTT STRAP WAS FOUND TO HAVE CORROSION BETWEEN FRAMES 16 AND 17. MAINTENANCE REMOVED DAMAGE AND REPLACED THE AFFECTED BUTTSTRAP IAW EMB 135 SRM 51-40-02. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR AALA20030547Beam · corrodedTHE 9-10 BEAM BOTH LEFT AND RIGHT HAD CORROSION REMOVED IN THE 2ND HOLE FROM OUTBOARD END, LEFT HOLE AT 463 AND RIGHT HOLE AT .532. FABRICATE A1-N1-BR BUSHING WITH .001 INTERFERENCE FIT WET WITH BMS 6-95 SEALANT. FINAL REAM ID TO ORIGINAL DUB SPEC. INSTALLESDR DL73S030412Door Frame · crackedTHE UPPER FRAME PORTION OF THE FWD FRAME ON THE C2 CARGO DOOR WAS FOUND WITH A CRACK IN THE LOWER FASTENER ROW OF THE FRAME AT THE LAP JOINT BETWEEN THE UPPER AND LOWER FRAME. THE CRACK WAS STOP DRILLED AND REPAIRED WITH 2 TITANIUM REPAIR ANGLES PER ER/ASDR 03FDEA00668Shear Tie · corrodedCORROSION ON SHEAR TIE STA 950E BETWEEN STR 29R AND 30R. CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED SHEAR TIE PER SRM 53-10-4, 53-10-1, 51- 10-6.SDR EIA2003080Door Frame · crackedPER N5349, LT ENTRY DOOR JAMB AFT STOP 4, BS 200 CRACKED AT DOOR STOP HOLE. REMOVED DAMAGE, INSTALLED, FABRICATED DOUBLERS & FILLERS PER SRM 53-05, PGS 546, 551, 552. REPEAT INSPECTION PER W/C N5343 AT OR BEFORE 28,000 CYCLES.SDR DL73S030413Gusset · crackedFUSELAGE / L1 DOOR OPENING / FWD FRAME / LOWER HINGE CUTOUT:GUSSET CRACK REPAIR THE FWD FRAME OF THE L1 DOOR OPENING STRUCTURE WAS FOUND WITH A CRACK IN THE 'H' GUSSET AT THE LOWER HINGE CUTOUT. THE CRACK WAS STOP DRILLED AND REPAIRED WITH A TITANIUM DOUSDR AUS20030652Bear Strap · cracked(AUS) FORWARD GALLEY DOOR CRACKED. SEVEN CRACKS FOUND ON FORWARD UPPER CORNER (BEAR STRAP AND INTERNAL DOUBLER) AND ONE CRACK FOUND ON THE AFT UPPER CORNER (BEAR STRAP DOUBLER). FOUND DURING EDDY CURRENT INSPECTION IAW ENGINEERING INSTRUCTION 737-53-14R4.SDR SWAA030941Crease Beam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CREASE BEAM WEB CORRODED BETWEEN BS 1006 & BS 1016, RT SIDE. REPAIRED CREASE BEAM WEB PER SRM.SDR TSAA0352106Door Frame · crackedREMOVED DAMAGED INBOARD DORR FRAME AREA, VERIFIED CRACK FREE USING HFEC. FABRICATED AN ANGLE DOUBLER FROM .063 INCH 2024-T3 CLAD MATERIAL. ALODINED AND PRIMED ALL BARE SURFACES. INSTALLED ANGLED DOUBLER PER FIGURE B. VERIFIED 8110-3 RECEIVED. REPAIR COMPLSDR ASAA0380412Door Frame · crackedOAK - DURING C-CHECK, FOUND LEFT MLG DOOR JAMB DOUBLER IS CRACKED. REPLACED PREVIOUSLY INSTALLED DOUBLER PER SRM 51-10-3 AND 53-01. (M)SDR DHL2003801005Door Frame · crackedFWD SERVICE DOOR JAMB WITH 2.000 INCH CRACK IN AFT LWR CORNER STA 180.000 L-20R- L-21R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DWG SR08530021, SRM 53-2-0 FIG 14. CUT OUT DAMAGED AREA IAW DWG DACCO SR08530021, SRM 53-2-0 FIG 14. FABRICATED FILLER, DOUBLERSDR C2XA03SH118Butt Strap · corrodedSHV DURING C CHECK RIGHT HAND BUTTSTRAP FOUND TO HAVE CORROSION AT FRAME 22. MAINTENANCE REMOVED DAMAGE AREA AND REPAIRED BUTTSTRAP IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR UPS03240672Support · crackedINSPECTION TYPE: C&SI, RT RAM AIR INTAKE DOOR SUPPORT BRACKET FOUND CRACKED AT BS 600 S25R. DOOR SUPPORT BRACKET FABRICATED IAW SRM 51-20-1 FIG 7, NEW BRACKET RE-PROTECTED IAW SRM 51-10-02 NEW DOOR SUPPORT AND FASTENERS RE-INSTALLED IAW SRM 51-30-02SDR QXEA0300536Striker · crackedPDX-FORWARD LOWER CORNER OF PASSENGER DOOR SEAL STRIKER ON FUSELAGE HAS A GOUGE AND CRACK IN METAL. REPAIRED IAW CRJ-700 SRM 51-42-06.SDR 03FDEA00592Stanchion · corrodedLOWER FORWARD CARGO AFT BULKHEAD STANCHION P/N A6A7094-9 AT STA X = 9.0 FOUND CORROSION (4 PLACES) ON FASTENERS HOLES.SDR 03FDEA00593Stanchion · corrodedLOWER FORWARD CARGO AFT BULKHEAD STANCHION P/N A6A7094-17 AT STA X = -9.0 FOUND CORROSION (6 PLACES) ON FASTENERS HOLES.SDR 2003F00568Rib · crackedDURING C-CHECK INSPECTION, A CRACKED RIB WAS FOUND AT BS 400 ABOVE STRINGER 20L. THE REPAIRS HAVE BEEN ACCOMPLISHED ON NON ROUTINE 031072. AIRCRAFT TOTAL TIME 46985.2. TOTAL CYCLES 41351. (M)SDR AWXA200300478Shear Tie · corrodedLCQ - MAJOR REPAIR - DURING C-17 CHECK EXFOLIATION CORROSION WAS FOUND ON SHEAR TIE AT BASE OF FRAME BS 927, STR 27 LT TO STR 27 RT. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; CUTOUT DAMAGED SECTION OF SHEAR TIE; FABRICATED A RSDR AWXA200300476Shear Tie · corrodedLCQ - MAJOR REPAIR - DURING C-17 CHECK INTERGRANULAR CORROSION WAS FOUND ON SHEAR TIE AT BS 500B BETWEEN STR 28 LT AND 28 RT. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; CUTOUT CORRODED AREA OF SHEAR TIE AT BS 500B BETWEEN STR 28SDR AWXA200300455Shear Tie · corrodedLCQ - MAJOR REPAIR - DURING C-17 CHECK INTERGRANULAR CORROSION WAS FOUND ON SHEAR TIE AT BS 500B, BETWEEN STR 28 LT AND 28 RT. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; CUTOUT DAMAGED SECTION OF SHEAR TIE AT BS 500B, BETWEEN SSDR SWAA030897Crease Beam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CREASE BEAM CORRODED FROM BS 380 TO BS 420, LT SIDE. REPAIRED CREASE BEAM PER SRM.SDR 03FDEA00577Shear Tie · crackedWHILE WORKING FOUND SHEAR TIE CRACKED AT BS 950D LBL 6 WL 147. REMOVED DAMAGED SHEAR TIE AT BS 950D LBL 6 WL 147 FABRICATED, ALODINE, PRIMED AND INSTALLED REPAIR IAW 53-10-4 FIG 15 AND FED EX EA 7-5310-69479.SDR ASAA0380387Shear Tie · corrodedOKC - DURING 30K CHECK, FOUND SHEAR TIE AT FRAME 712 BETWEEN L30 AND L29. REPLACED SHEAR TIE PER SRM. (M)SDR GTIA030308Structure · corrodedCABIN STA 218, LBL 43, SUBFLOOR CORRODED. CUT OUT DAMAGE. DRILL AND LOCATE DOUBLER. INSTALLED DOUBLER.SDR 03FDEA00561Structure · corrodedCORROSION AROUND FASTENER HOLES, BS 740-759, LBL 6-RBL 6, WL 138. REPAIRED PER SRM 53-10-1, 53-10-2, AND 51-40-2.SDR SWAA030889Crease Beam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CREASE BEAM CORRODED BETWEEN BS 500C & BS 500D, LT SIDE. REPAIRED CREASE BEAM PER SRM.SDR SWAA030901Shear Tie · crackedDURING SCHEDULED D-CHECK, FOUND SHEAR TIE CRACKED AT BS 360, BETWEEN STR 14R & STR 15R. REPAIRED SHEAR TIE PER SRM.SDR C2XA03SH111Butt Strap · corrodedSHV-DURING C-CHECK THE CENTER BUTT STRAP BETWEEN FRAMES 18 AND 23 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BUTT STRAP IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR UPS03840459Shear Tie · crackedINSPECTION TYPE: C3, APPROX. STA 700, LONG 35 RT, SHEAR TIE (FRAME ANGLE) UNDER STRESS PN L IS CORRODED AND CRACKED REMOVED DAMAGED SECTION OF SHEAR TIE IAW DC8 SRM 51-1-20D, FABBED NE W SECTION IAW DWG 9753780, LOCATED AND DRILLED UP NEW SECTION IAW D WGSDR SIMA200312713Beam · corrodedABI - THIS IS A LEVEL 2 FINDING FOUND DURING AN IMBV INSPECTION, GALLEY CENTER BEAM GUSSET CORRODED. REMOVED AND INSTALLED NEW CENTER BEAM IAW EMB 145 SRM 51-40-02/04/06, 51-20-03. (M)SDR QXEA0300505Structure · damagedPDX-DENT DAMAGE BETWEEN X281.0 AND X301.0, SRINGER 12 AND STRINGER 11. REPAIRED IAW HORIZON AIR EA 6-53-171 AND RD84-53-440.SDR QXEA0300504Structure · damagedPDX-DENT DAMAGE BETWEEN X281.0 AND X301.0, STRINGER 6 AND STRINGER 7. REPAIRED IAW RD84-53-443 AND HORIZON AIR EA 6-53-171.SDR ASAA0380356Support Beam · crackedOAK - DURING 15K CHECK, FOUND MID CARGO BAY BARRIER DOOR SUPPORT BEAM IS CRACKED. INSTALLED DOUBLER ON BEAM PER SRM 51-10-3. (M)SDR ASAA0380354Support Beam · crackedDURING 15K CHECK, FOUND MID CARGO BAY BARRIER DOOR SUPPORT BEAM CRACKED ON INBOARD SIDE. INSTALLED DOUBLERS ON BEAM PER SRM 52-10. (M)SDR SIMA200312719Gusset · corrodedTHIS IS A LEVEL 2 FINDING FOUND DURING AN IMBV INSPECTION GALLEY AREA CENTER BEAM GUSSET HAS CORROSION. REMOVED AND REPLACED CENTER BEAM GUSSET IAW EMB 135 SRM 51-40-02. (M)SDR SIMA200311314Beam · corrodedDURING AN IMBV INSPECTION, THE GALLEY CENTER HAT BEAM AT FRAME 20 WAS FOUND TO BE CORRODED BELOW SRM LIMITS. CUT OUT DAMAGED AREA OF THE HAT BEAM, CLEANED AND TRETED THE AREA. FABRICATED A REPAIR DOUBLER AND ATTACHED. REPAIR DONE IAW EMB 145 SRM, SRM EMB 14SDR QXEA0300520Structure · crackedPDX-BOTTOM DAMAGE ON STRUCTURE AND STARTING TO CRACK AT RIGHT HAND EMERGENCY DOOR. REPAIRED IAW DHC-8 SRM 51-20-11 AND SRM 51-00-06.SDR UPS03240685Door Frame · crackedINSPECTION TYPE: C&SI, SUSPECT CRACK AT NR 1 STOP FITTING CUT OUT ON FWD FRAME OF AFT CARGO DOOR CUTOUT. REPAIR CARRIED OUT IAW SRM 51-30-02 & SMRO EO 2003-025-021 UPS ENGINEERING FILE NO. B727-5330-18744-ASDR UPS03840470Fitting · crackedINSPECTION TYPE: C1, STATION 380-400 LONGERON 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG. 3754473 AND SRM. 51-1-20DSDR SIMA200312707Gusset · corrodedABI - THIS IS A LEVEL 2 FINDING FOUND DURING AN IMBV INSPECTION, THE DIAMOND GUSSET AND RIGHT HAT BEAM AT FRAME 20 HAS CORROSION. REMOVED AND INSTALLED SERVICEABLE DIAMOND GUSSET ON RIGHT HAT BEAM IAW EMB 135 SRM 51-20-03, 51-40-02/06. (M)SDR 03FDEA00458Frame · crackedCRACK AT LIGHTENING HOLE IN HORIZONTAL FRAME AT BS 1183 RBL 44 WL 194.0. FABRICATED AND INSTALLED FRAME SECTION IAW BOEING 727-200 SRM 51-30-2 PG 2 AND 3 ITEM B AND 51-30-2 PG 8 ITEM D.SDR SIMA200312710Gusset · corrodedTHIS IS A LEVEL 2 FINDING FOUND DURNG AN IMBV INSPECTION, CENTER FLOORBEAM GUSSET CORRODED IN GALLEY. REMOVED AND INSTALLED SERVICEABLE CENTER FLOOR GUSSET IN GALLEY IAW EMB 135 SRM 51-40-02/06, 51-20-03. (M)SDR ABXA030166Door Frame · corrodedEVIDENCE OF CORROSION DETECTED AROUND FORWARD LOWER CARGO DOOR JAMB LOWER SET SCREW FITTINGS, BETWEEN SKIN LAYERS. REPAIRED AREA IAW REA D953-47181MR AND DC-9 SRM 53-05.SDR GTIA030318Door Frame · corrodedAFT PIT STA 1155 FORWARD DOOR FRAME CORRODED. REMOVED DAMAGED AREA. FORMED REPAIR. INSTALLED 2 REPAIR PIECES.SDR DL73S030365Doubler · crackedTHE 'H' DOUBLER AROUND THE LOWER HINGE CUTOUT FOR THE L1 DOOR CUTOUT FWD FRAME WAS FOUND WITH A 3/8 INCH CRACK IN THE CORNER RADIUS. THE CRACK WAS STOP DRILLED AND REPAIRED WITH A TITANIUM REPAIR DOUBLER PER ER/A 384891-14, REV B.SDR C2XA03TY049Shear Tie · bentTYS, DURING A SCHEDULED INSPECTION A DENT WAS FOUND ON THE LEFT FORWARD FUSELAGE BETWEEN FRAMES 10 AND 11 AND BETWEEN STRINGERS 13L AND 15L. MAINTENANCE REMOVED THE DAMAGED SHEAR CLIP, RESTORED SKIN AND INSTALLED A NEW SHEAR CLIP IAW EC5330-01246. THE REPAIRSDR QXEA0300501Sill · corrodedFORWARD PASSENGER DOOR SILL HAS CORROSION IN NUMEROUS PLACES. REPAIRED IAW DHC-8 SRM 51-42-05-330-801, PAGES 201-218, PARAGRAPH 1-4.SDR AWXA200300468Shear Tie · crackedYVR - MAJOR REPAIR - DURING C-15 CHECK A 1 INCH CRACK WAS FOUND ON VERTICAL ATTACH ANGLE (SHEAR TIE) AT FORWARD AND AFT SIDES OF BS 597, RT OUTBOARD SIDE. MAINTENANCE TRIMMED OUT DAMAGE ON SHEAR TIE AND FRAME AT FLANGE BEND; PERFORMED HFEC INSPECTION TO VERIFSDR UPS03440622Shear Tie · crackedINSPECTION TYPE:C M/D - BS 1301 LT STR 16L SHEAR TIE FOUND CRACKED. SHEAR TIE REPLACED AS PER SRM 51-10-01 PAGE 8.
Back to JASC 5310