JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR KCSA101004Strap · crackedFUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, RBL 20.SDR KCSA101003Strap · crackedFUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, RBL 10.SDR KCSA101001Strap · crackedFUSELAGE FRAME STABILIZATION STRAP IS CRACKED AT STA 2180 TO 2200, LBL 10.SDR AALA20100108TUL23Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET STATION 480 LEFT SIDE AT INBOARD FASTENER. REPAIRED BRACKET PER ECO J1159AC AND EA B727-53-008586.SDR AALA20100108TUL22Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET, STATION 500C LEFT SIDE AT INBOARD FASTENER. REPAIRED BRACKET PER ECO J1159AC AND ENGINEERING AUTHORIZATION B727-53-008586.SDR CA100120002Tube Frame · cracked(CAN) A CRACK WAS DISCOVERED IN THE AIRFRAME TUBING STRUCTURE FWD OF THE LT RUDDER PEDAL TORQUE TUBE SUPPORT LOCATION. THE CRACK WAS NOTED DURING A 100 HOUR INSP. THE CRACK APPEARED TO HAVE DEVELOPED QUICKLY WITHIN THE LAST 50 HOURS OF OPERATION. THE CRACK EXSDR AALA20100108TUL12Frame · crackedFRAME AT STATION 360 CRACKED. WORK ACCOMPLISHED UNDER ENGINEERING AUTHORITY B737-53-008557.SDR F3LA2010011200296Frame · corrodedDURING C5 C-CHECK INSP NOTED AFT PIT FRAME 56 ANGLE ON FWD SIDE OF FRAME IS CORRODED AT 2 FASTENER HOLES. MX REMOVED AND REPLACED ANGLE AT FRAME 56 IAW SRM 51-44-11.SDR SIMA201001104Frame · damagedDURING MAINTENANCE BASE VISIT INSPECTION FOUND FRAME 65 RIGHT TO HAVE TOOLING MARKS BEYOND STRUCTURAL REPAIR MANUAL LIMITS. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED TOOLING MARKS IAW AEAI ENGINEERING ORDER EM-53MR-1449. THE AIRCRAFT WAS RETURNED TO SSDR SWAA100112Frame · crackedDURING SCHEDULED 12Y CHECK, FOUND FRAME CRACKED AT BS 440, STR 8R. REPAIRED FRAME PER EA.SDR ASOA20100013Frame · crackedRT 640 FRAME REPLACED DURING THE INCORPORATION OF SB 601R-53-065. REF ASA TASKCARD EO 600-53-0356 JOB NR 8729015 OP NR 5586. (CLOSED)SDR AALA20100106TUL07Frame · crackedCRACK IN SKIN ON FUSELAGE RIGHT SIDE AT STATION 1474 CANT FRAME AT LONGERON 24 RIGHT. INSTALLED DOUBLER PER SRM 53-01-00 FIG 2.SDR F3LA2010011500301Frame · corrodedDURING C5 C-CHECK INSP NOTED AFT PIT FRAME 59 HAS EVIDENCE OF CORROSION IN FASTENER HOLES. MX REMOVED AND REPLACED FITTING IAW EA A9-53R-31612 AND EA A9-53R-31625.SDR QXEA2010010800018Frame · crackedC5 CHECK - FRAME AT STA X-18.250 IS CORRODED BETWEEN STR 31L TO STR 33. REMOVED CORROSION IAW RD 8/4-53-2344. HFEC INSPECTED BLENDED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801. NO CRACKS NOTED. UT THICKNESS CHECK IAW NDTM PART 1, 51-00-04. ALODSDR ASOA201000013Frame · crackedRT 640 FRAME IS CRACKED BETWEEN STRINGERS 10 AND 11. (OPEN)SDR CALA2010010800011Frame · crackedB737-06-3-0046 MAIN CABIN FUSELAGE FRAME AT STA 500A BETWEEN S-8L AND S-9L CRACKED AT PSU RAIL ATTACH BRACKET I/B RIVET HOLE. INSTALLED FRAME REPAIR AND NEW MODIFIED SUPPORT FITTING REF ECRA 5310-05070 PART B AND C.SDR CALA2010010800010Frame · crackedB737-06-3-0046 MAIN CABIN FUSELAGE FRAME AT STA 440 BETWEEN S8L AND S-9L CRACKED AT PSU RAIL ATTACH BRACKET I/B RIVET HOLE. INSTALLED FRAME REPAIR AND NEW MODIFIED SUPPORT FITTING REF ECRA 5310-05070 PART B AND C.SDR CALA2010010800009Frame · crackedB737-06-3-0046 MAIN CABIN FUSELAGE FRAME AT STA 400 BETWEEN S8R AND S-9R CRACKED AT PSU RAIL ATTACH BRACKET I/B RIVET HOLE. INSTALLED FRAME REPAIR AND NEW MODIFIED SUPPORT FITTING REF ECRA 5310-05070 PART B AND C.SDR CALA2010010800008Frame · crackedB737-06-3-0046 MAIN CABIN FUSELAGE FRAME AT STA 400 BETWEEN S-8L AND S-9L CRACKED AT PSU RAIL ATTACH BRACKET I/B RIVET HOLE. INSTALLED FRAME REPAIR AND NEW MODIFIED SUPPORT FITTING REF ECRA 5310-05070 PART B AND C.SDR FDEA201001060024Frame · corrodedAFT PIT FUSELAGE FRAME STA 1480 HAS CORROSION FROM S-27R TO S-25R. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL 3; L=.025",W=.025",D=.012", AT BS 1480, S25R-27R. FABRICATED REPAIR PARTS OSDR SWAA100089Frame · crackedDURING SCHEDULED 18Y CHECK, FOUND FRAME CRACKED AT BS 482B LT WIRE PENETRATION HOLE. REPAIRED FRAME PER SRM.SDR SWAA100084Frame · crackedDURING SCHEDULED SPV CHECK, FOUND FRAME CRACKED AT BS 986.5, BETWEEN STR 2L TO STR 3L. REPAIRED FRAME PER SRM.SDR SWAA100083Frame · crackedDURING SCHEDULED SPV CHECK, FOUND FRAME CRACKED AT BS 277, STR 16L. REPAIRED FRAME PER SRM.SDR SWAA100080Frame · crackedDURING SCHEDULED SPV CHECK, FOUND FRAME CRACKED AT BS 480, STR 8L. REPAIRED FRAME PER EA.SDR COMA2010010650010Frame · crackedFOUND CRACK AT LEFT SIDE OF FS 640 FRAME AT STRINGER 9 CUT OUT. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER IN ACCORDANCE WITH REO 601R-53-061 REV E DATED 07/2006 AND APPENDIX B PART C REV C DATED JUNE 25/2003.SDR AALA20100108TUL10Frame · crackedFRAME 500F RIGHT CRACKED. REPAIRED FRAME 500F RIGHT PER ENGINEERING CHANGE ORDER J1159AC.SDR AALA20100108TUL08Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET AT STATION 727D LEFT SIDE AT INBOARD FASTENER. REPAIRED FRAME PER ENGINEERING CHANGE ORDER J1159AC.SDR AALA20100108TUL07Frame · crackedFRAME 440 LEFT CRACKED. REPAIRED FRAME 440 LEFT PER ENGINEERING CHANGE ORDER J1159ACSDR AALA20100108TUL06Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET STATION 440, LEFT SIDE AT INBOARD FASTENER. REPAIRED FRAME 440 LEFT PER ECO J1159AC.SDR AALA20100108TUL05Frame · crackedFRAME 500C RIGHT CRACKED. REPAIRED FRAME 500C RIGHT PER ENGINEERING CHANGE ORDER 1159AC.SDR AALA20100108TUL03Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET STATION 827 LEFT SIDE AT INBOARD FASTENER. REPAIRED FRAME 827 LEFT SIDE PER ECO J1159AC.SDR FDEA201001050011Frame · crackedFWD CARGO AREA, BS 640, STR 28L, CRACKED FRAME. CUT-OUT DAMAGE IN B640 FRAME AT STR. 28L, 1" X 1 1/4" IAW SRM REV 102, 51-10-1. FABRICATED REPAIR DOUBLER IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 3. HEAT TREATED REPAIR DOUBLER TO -T6 CONDITION IAW FAS ENGINEERINGSDR FDEA201001050016Frame · damagedFUSELAGE FRAME UPPER EXPOSED FLANGE HAS TOOL MARK DAMAGE "DRILL MARK", FRAME STA 1640, BTW S-26L AND 27L. DAMAGED FRAME FLANGE STA 1640, BTW S-26L AND S-27L FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, PG 103, FIG. 101, DETAIL II. ORIG MAT .063, MAT. LOSS .020SDR FDEA201001050015Frame · corrodedFUSELAGE FRAME UPPER CHORD HAS CORROSION STA 1640, S-22L. AFTER FURTHER EVALUATION IAW DWG NR 146N1023 FRAME THICKNESS IS .080, AFTER BLEND OUT FOR CORROSION REMOVAL, MAT REMAIN IS .077, FRAME IS WITHIN LIMITS IAW SRM 53-00-07 FIG. 101 DET. 2 AND IS A MINOR RSDR QXEA2010010600010Frame · corrodedPDX - C5 CHECK - CORROSION ON FRAME FLANGE AT ST 341.00 BETWEEN STR 31L AND STR 32L. REMOVED RIVET FOR ACCESS AND BLENDED AREA OF CORROSION, FOUND BLEND AREA TO BE WITHIN LIMITS IAW RD 8/4-53-2344. PERFORMED HFEC INSP IAW 1-84-7A, PT 6, 51-00-01, NO CRACKS NSDR QXEA2010010600009Frame · corrodedC5 CHECK - CORROSION ON FRAME FLANGE AT ST 281.00 BETWEEN STR 31R AND STR 32R. REMOVED RIVETS FOR ACCESS AND BLENDED AREA OF CORROSION, FOUND BLEND AREA TO BE WITHIN LIMITS IAW RD 8/4-53-2344. HFEC INSPECTED BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801SDR QXEA2010010600008Frame · corrodedC5 CHECK - CORROSION ON FRAME FLANGE AT ST 281.00 BETWEEN STR 31L AND STR 32L. REMOVED RIVETS FOR ACCESS AND BLENDED AREA OF CORROSION, FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. HFEC INSPECTED BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801, NO CRACKSSDR QXEA2010010600007Frame · corrodedC5 CHECK - CORROSION ON FRAME FLANGE AT BS 301.00 BETWEEN STR 31R AND STR 32R. REMOVED RIVETS FOR ACCESS AND BLENDED AREA OF CORROSION, FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. HFEC INSPECTED BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801, NO CRACKSDR QXEA09010600005AFrame · corrodedC5 CHECK - CORROSION ON FRAME FLANGE AT ST 301.00 BETWEEN STR 31L AND STR 32L. BLENDED AREA OF CORROSION AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. HFEC INSPECTED BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801, NO CRACKS NOTED. ALODINED, PRIMED ASDR SWAA100077Frame · crackedDURING SCHEDULED MV2 CHECK, FOUND FRAME CRACKED AT BS 482, BETWEEN STR 20L TO STR 21L. REPAIRED FRAME PER SRM.SDR SWAA100076Frame · crackedDURING SCHEDULED MV2 CHECK, FOUND FRAME CRACKED AT BS 482A, BETWEEN STR 20L TO STR 21L. REPAIRED FRAME PER SRM.SDR FDEA201001050012Frame · crackedFWD CARGO AREA, BS 620, STR 28R, CRACKED FRAME. CUT OUT DAMAGE IN FWD PIT ON STA 620 FRAME AT STR 28R, IAW SRM 51-10-1. FABRICATED REPAIR DOUBLER IAW SRM 51-40-3, FIG 1 AND 53-10-2 FIG 3. HEAT TREATED REPAIR DOUBLER TO T6 CONDITION IAW FAS ENG REPORT NR 2-371SDR IPXA10563473Frame · dentedINSPECTION TYPE:C4, AFT CARGO BAY FRAME INNER FLANGE IS DENTED BS 1260, STR 26-27L REPAIRED IAW EO B757-5310-40390-A.SDR AALA20100105TUL01Frame · crackedFRAME CRACKED AT AIR CONDITIONING RAIL BRACKET STATION 380 LEFT SIDE AT INBOARD FASTENER. REPAIRED CRACKED FRAME UNDER ECO J1159AC.SDR FDEA201001040085Frame · crackedFORWARD CARGO AREA, BS 620, S28L, CRACKED FRAME. CUT OUT DAMAGED AREA IAW SRM 51-10-1. FABRICATED REPAIR DOUBLER IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 3. HEAT TREATED REPAIR DOUBLER TO T6 CONDITION IAW FAS ENGINEERING REPORT NR 2-37153-801 REV A. INSTALLED RSDR SWAA100050Frame · crackedDURING SCHEDULED 18Y CHECK, FOUND FWD CARGO BAY FRAME CRACKED AT BS 482B, BETWEEN STR 20L TO STR 21L. REPAIRED FRAME PER AAR EA.SDR SWAA100047Frame · corrodedDURING SCHEDULED SPV CHECK, FOUND FRAME CORRODED AT BS 360, BETWEEN BL 0 TO LBL 5. REPAIRED FRAME PER SRM.SDR GLBA20100104JFrame · crackedMAJOR REPAIR - DURING ROUTINE SCHEDULED MX 2 CRACKS WERE FOUND AT THE AIRSTAIR DOOR FUSELAGE FRAME AT FS 150 AT THE LWR STRUT MOUNT AREA. CRACKS MEASURE 1" AND 1.25" RESPECTIVELY. MX REPAIRED THE AFFECTED AREA AND PERFORMED THE REQUIRED RII INSPECTIONS IAW SDR GLBA20100104GFrame · crackedMAJOR REPAIR - DURING ROUTINE SCHEDULED MX CRACK WAS FOUND IN THE RT SIDEWALL FRAME AT TS 164 AND STRINGER 9AR CUTOUT. CRACK IS APPROX 1.75" IN LENGTH. MX REPAIRED THE AFFECTED AREA AND PERFORMED THE REQUIRED RII INSPECTIONS IAW EO 09-120-53-001. MATERIALS SDR ASAA1047245Frame · corrodedFRAME AT STA 767 ABOVE STR 24L 24R HAVE CORROSION AT FASTENER HOLES. REMOVED CORRODED FRAME AND INSTALLED NEW FRAME.
Back to JASC 5311