JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202053090Doubler · crackedREPAIR DOUBLER ON FS 280.00 FLOOR BEAM (AFT FACE) IS CRACKED AT APPROXIMATELY RBL 12. C-CHECK RO 10/4/2020. REPAIRED -4 REPAIR ANGLE ON FS 280.00 FLOOR BEAM AFT FACE AT APPROXIMATELY RBL 12, REF REO. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH ATTACHED TASDR SWIA202053089Doubler · crackedREPAIR DOUBLER ON FS 280.00 FLOOR BEAM (AFT FACE) IS CRACKED AT APPROXIMATELY LBL 12. C-CHECK RO 10/4/2020. REPAIRED -1 REPAIR DOUBLER ON FS 280.00 FLOOR BEAM AFT FACE AT APPROXIMATELY LBL 12, REF REO. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH ATTACHED SDR SWIA202053088Floorbeam · corrodedFLOOR SUPPORT AT FS 280.00 BETWEEN LBL 9 AND RBL 9 IS CORRODED. C-CHECK RO 10/4/2020. REMOVED AND REPLACED FLOOR SUPPORT AT FS 280 BETWEEN LBL 9 AND RBL 9, REF CRJ200 SRM AND DWG. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH TASK CARD.SDR DALA2020090532965Floorbeam · crackedDURING HCK AT QRO, WHILE PERFORMING A BASE ZONAL INSPECTION PER WC 5300-2342, SEVERAL CRACKS WERE FOUND AFFECTING PANEL BREAK DETAILS P/N 143A5240-33 & -34 AT STA 540 BTW RBL 24.75 - LBL 24.75, PERTAINING TO LOWER LOBE INTEGRATION INSTALLATION. DAMAGE WAS REPASDR VGCA202009098302Floorbeam · corrodedCORROSION ON FLOOR BEAM LOWER FLANGE AT STATION 950D LBL 20.SDR SWAA2020090413981Floorbeam · crackedMAIN CABIN FLOOR BEAM INTERCOSTAL CRACKED AT STA. 540 RBL. 2'. REMOVED OLD INTERCOSTAL AND INSTALLED NEW INTERCOSTAL PER SRM 51-40-02-0G-0. REINSTALLED FLOOR PANEL 231XF PER AMM 53-21-00.SDR SWAA2020090212214Floorbeam · pulledPASSENGER CABIN FLOOR STRUCTURE; STATION 540; RBL 45-55 EXPANSION CHANNEL UPPER SKIN HAS PULLED FASTENERS. REMOVED AND REPLACED A PASSENGER CABIN FLOOR STRUCTURE EXPANSION CHANNEL (PANEL BREAK) AT STA. 540 RBL 45-55 IAW SRM 51-40-02-0G-0 AND DWG #143A5240 REVSDR SWAA2020090212216Floorbeam · pulledPASSENGER CABIN FLOOR STRUCTURE; STATION 540 LBL 45-55; EXPANSION CHANNEL UPPER SKIN HAS PULLED FASTENERS. REMOVED PASSENGER FLOOR STRUCTURE EXPANSION CHANNEL STA 540 LBL 45 TO 65 AND INSTALLED NEW EXPANSION CHANNEL ALL IAW SRM 51-40-02-0G-0 AND DWG 143A5240 SDR SWAA2020090212217Floorbeam · crackedPASSENGER CABIN FLOOR STRUCTURE; STATION 540 RBL 03; EXPANSION CHANNEL CRACKED LOWER INBOARD CORNER. REMOVED AND REPLACED A PASSENGER CABIN FLOOR STRUCTURE EXPANSION CHANNEL (PANEL BREAK) AT STA 540 RBL 3YAW SRM 51-40-02-0G-0 AND DWG #143A0060 REV A. REMOVEDSDR SWAA2021071512239Floorbeam · crackedCABIN FLOOR PANELS SUPPORT ANGLES LT AND RT AT B.L. ZERO STATION 540 HAVE CRACKS AT ATTACHMENTS. / REMOVED AND REPLACED FLOOR SUPPORT ANGLES LT AND RT B.L. ZERO STA 540. AS PER SRM : 51-40-02-0G-0 AND REINSTALL FLOOR PANEL # 231UF AS PER SRM 53-21-00-000-801.SDR SWAA2020092112231Floorbeam · corrodedCORROSION, FLIGHT DECK FLOOR STRUCTURE AT STA 270 FORWARD SIDE OF LATERAL BEAM BETWEEN LBL 10 TO RBL 10 WL 208.1 HAS SPOTS OF CORROSION, MARKED 78-8. REPAIRED FLIGHT DECK FLOOR STRUCTURE AT STA 270 FWD SIDE OF LATERAL BEAM BETWEEN LBL 10 TO RBL 10 WL 208.1, ASDR SWAA2021072112378Floorbeam · corroded***CORROSION*** ON FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS887 LBL7 TO RBL21 WL168. / REMOVED SUPPORT SPLICE AT ACB BS887; RECIEVED NEW SUPPORT SPLICE ON P.O. 761896. LOCATED AND DRILLED IAW SRM 51-40-05; 51-40-08; AND DWG#146A9401. 59118U 08SEP20 OK TO INSTALSDR SWIA202053257Angle · crackedPRESSURE FLOOR ANGLE/CLIP CRACKED AT FS 484 AND RBL 27. C-CHECK RO 10/13/2020. REMOVED AND REPLACED CLIP, IAW CRJ 200 SRM.SDR SCNA20201007055Floorbeam · corrodedAFT CARGO BAY FLOOR SUPPORT TEE SPLICE STA 727I+5 HAS CORROSION AROUND MULTIPLE NUTPLATES. AFT CARGO BAY FLOOR SUPPORT TEE SPLICE STA 727I+5 HAS CORROSION AROUND MULTIPLE NUTPLATES. FOUND TO BE OUT OF LIMITS DUE TO NO PUBLISHED LIMITS IN SRM. REMOVED AND RESDR SWIA202052882Floorbeam · corrodedREMOVE AND REPLACE LT AND RT FS 280 FLOOR BEAMS WITH SERVICEABLE, DUE TO OUT OF LIMIT CORROSION. C-CHECK RO 9/27/2020. REMOVED AND REPLACED LT AND RT FS 280 FLOOR BEAMS WITH SERVICEABLE PARTS, REF DWG SRM. COMPLIED WITH TASK CARD. SEE CONTINUATION CARD FORSDR SWIA202052881Floorbeam · corrodedRT FS 280 FLOOR CROSS BEAM HAS CORROSION BETWEEN RBL 9 AND LBL 9. C-CHECK RO 9/27/2020. RT FS 280 FLOOR CROSS BEAM BETWEEN RBL 9 AND LBL 9 HAS CORROSION ON FWD FACE THAT IS PITTED AND EXFOLIATED 100% MATERIAL LOSS AND IS OUT OF LIMITS, REF CRJ 700 SRM. RT FSDR SWIA202052880Floorbeam · corrodedLT FS 280 FLOOR CROSS BEAM HAS CORROSION BETWEEN RBL 9 AND LBL 9. C-CHECK RO 9/27/2020. LT FS 280 FLOOR CROSS BEAM BETWEEN RBL 9 AND LBL 9 HAS CORROSION ON FWD FACE THAT IS PITTED AND EXFOLIATED 100% MATERIAL LOSS AND IS OUT OF LIMITS, REF CRJ 700 SRM. LT FSDR AALA202008319010Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR PANEL BREAK ASSEMBLY AT STA 540 BETWEEN BL 0 AND BL 24R, MEASURING L=1.0 IN. REPLACED BREAK WITH NEW IAW AARD 51-00-05-1.SDR AALA202008319009Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR PANEL BREAK ASSEMBLY AT STA 540 BETWEEN BL 0 AND BL 24L, MEASURING L=1.0 IN. REPLACED BREAK WITH NEW IAW AARD 51-00-05-1.SDR SWAA2021080312970Floorbeam · crackedCRACKED BREAK PANEL STA 540; LBL 1; WL 208. / REMOVED AND REPLACED BREAK PANEL STA540; LBL1 WL208 PER DWG# 143A0060 REV A; SRM 51-40-02-0G-0; SRM 51-40-05-0G-0SDR SWIA202053262Floorbeam · corrodedRT FLOORBOARD SUPPORT BRACKET BETWEEN RBL 9 AND RBL 18 AT FS 559.00+80 IS CORRODED. C-CHECK RO 10/13/2020. REPLACED EXISTING SUPPORT PLATE P/N 601R32215-43 WITH NEW, SERVICEABLE SUPPORT PLATE P/N 601R32215-13, IAW CRJ 200 SRM.SDR SWAA2020091812318Floorbeam · corrodedCORROSION AFT CARGO BAY FLOOR BEAM AFT END SUPPORT AT STA 947 LBL 9 WL 177. REMOVED AND REPLACED AFT CARGO BAY FLOOR BEAM AFT END SUPPORT AT STA 947 LBL 9 WL 177, IAW SRM 51-40-02-0G-0 AND DWG 147A1047 REV.SDR YENA2020083100444Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM -Y1292 AT FR68. EVALUATED CORROSION ON FLOOR BEAM -Y1292 AT FR 68, MATERIAL LOSS OF .035 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11 AND 53-00-14SDR YENA2020083100443Floorbeam · corrodedDURING HEAVY MAINTENANCE, AFT WET AREA FR68 -Y300 FLOOR BEAM SMALL SPOT OF CORROSION; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00016 ) EVALUATED CORROSION AT FLOOR BEAM -Y300 FR 68 MATERIAL LOSS OF .029 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SDR YENA2020083100440Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM Y1292 AT FR 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00013 ) EVALUATED CORROSION ON FLOOR BEAM Y 1292 AT FR 68 MATERIAL LOSS OF .026 IS OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM IAW A32SDR YENA2020083100439Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM Y765 AT FR 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00012 ) REMOVED AND REPLACED FLOOR BEAM AFT WET AREA Y765 AT FR 68 IAW A320 SRM 51-42-11 MATERIAL LOSS OF .022 IS OUT OF LIMITS IAW A320 SRMSDR YENA2020083100438Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION IN AFT WET AREA ON FLOOR BEAM -Y765 AT FRAME 68; (RESOLVED ON W/O: 1056627 TASKCARD: NR-00011 ) EVALUATED AREA FLOOR BEAM -Y765 AT FR 68 CORROSION MATERIAL LOSS OF .037 IS OUT OF LIMITS REMOVED AND REPLACED FLOOR BEAM IAW ASDR SWAA2021071511760Floorbeam · corroded***CORROSION*** ON SUPPORT ANGLE AT PASSENGER CABIN BS705 RBL65 WL203. / THE DAMAGE IS INSPECTED AND REPAIRED PER EA 20-153-01725 REV IR (ATS ER 20-03181 REV IR).SDR SWIA202053204Floorbeam · corrodedUPON REMOVAL OF STRAP/SHIM ON JOB: 4 OP: 109, FOUND CORROSION ON FLOOR CROSS BEAM FS 349 LBL 9. C-CHECK RO 10/9/2020. REPAIRED FLOOR CROSS BEAM LBL 9.0 AT FS 349 BY REMOVING CORROSION AND INSTALLING NEW PACK AND FABRICATED SHIM, REF REO.SDR SWIA202052864Floorbeam · corrodedRBL 9 FLOOR BEAM HAS CORROSION AROUND FASTENER UPPER OUTBOARD SIDE AT FS 501.00. C-CHECK RO 9/27/2020. CUT AWAY DAMAGE ON DAMAGED SECTION OF FLOOR BEAMS, REF CRJ700 SRM. FABRICATED, LOCATED AND DRILLED REPAIR PARTS, REF CRJ700 SRM. INSTALLED REPAIR PARTS TSDR SWIA202052850Floorbeam · corrodedFLOOR SUPPORT CORRODED AT MULTIPLE AREAS, FORWARD SIDE OF THE FS 280.00 BEAM BETWEEN BL 9L-BL 9R. C-CHECK RO 9/27/2020. FLOOR SUPPORT ANGLE AT FS 280 BETWEEN BL 9L-BL 9R IS CORRODED AND OUT LIMITS, REF CRJ-700 SRM. REMOVED AND INSTALLED NEW COCKPIT FLOOR SUSDR SWAA2020092212027Floorbeam · corrodedCORROSION AT BS 270 LBL 6 TO RBL 10 WL 208. DAMAGE REPAIRED, PER EA 1-A53-13812 REV 2.SDR IPXA2020092060410Floorbeam · crackedINSPECTION TYPE: 2C LOWER FWD CARGO FLOOR BEAM IS CRACKED AT STA 6-70 AND X=57.50. REPAIRED CRACKED FLOOR BEAM AT STA 6-70 AND X=57.50, IAW VT-SAA EA 011-5340-01-A8529 REV. I/R AND UPS EO MD11-5340-77877-A (MAJOR).SDR FDEA202008252021Floorbeam · corrodedCABIN FLOOR BEAM CORRODED BS 375, BL354L. REMOVED CORROSION IAW B757 SRM 51-10-02. DAMAGE FOUND TO BE OUT OF LIMITS IAW B757 SRM 53-00-51-1A. ACCOMPLISHED FLOOR BEAM REPAIR IAW FEDEX EA "F-5310-T0356115-P1. FUSELAGE-MAINFRAME, MAIN CABIN FLOOR BEAM STA 377SDR VNAA202008249994Floorbeam · corrodedLH FS280.00 FLOOR BEAM TO BE CORRODED BEYOND LIMITS, REQUIRING REPLACEMENT DEEPEST DEPTH OF CORROSION IS .048 MAX ALLOWED IS .006. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE L/H FS 280.00 BEAM P/N: CC670-34094-15 IAW CRJ900 SRM 51-40-11-001-001-A01.SDR IPXA202009160268Floorbeam · corrodedINSPECTION TYPE: 2C CENTER CARGO FLOOR BEAM HAS CORROSION AT STA 1781 X=-58. REPAIRED CORRODED FLOOR BEAM IN CENTER CARGO STA 1781 X= -58, IAW EA 011-5310-01-A8538 REV IR AND EO MD11-5310-77782-A (MAJOR).SDR SWIA2020091152467Floorbeam · crackedFLIGHT DECK FLOOR SUPPORT BRACKET CRACKED AT FRAME 12 ON PILOTS SIDE, AS MARKED. C-CHECK RO 9/8/2020. REMOVED AND REPLACED FLIGHT DECK FLOOR SUPPORT BRACKET AT FRAME 12 ON PILOTS SIDE. REF EMB175 SRM.SDR SWIA202053194Floorbeam · corrodedAPPROXIMATELY FS 748.50 RT FLOOR ANGLE CORRODED, MARKED. C-CHECK RO 10/9/2020. REMOVED CORROSION FROM THE FLOOR ANGLE AT FS 748.50, REF MHIRJ REO. COMPLIED WITH TASK CARD.SDR SWIA202053193Floorbeam · corrodedAPPROXIMATELY FS 762.50 RT FLOOR ANGLE CORRODED, MARKED. C-CHECK RO 10/9/2020. REPLACED FLOOR ANGLE ON FS 762.50, REF MHI REO. COMPLIED WITH TASK CARD.SDR SWIA2020091052439Floorbeam · crackedCOCKPIT FLOOR CENTER ANGLE SUPPORT CRACKED AT FR 12. C-CHECK RO 9/6/2020. REMOVED AND REPLACED COCKPIT FLOOR CENTER ANGLE SUPPORT AT FR 12, REF EMB SRM.SDR SWAA2020090413969Floorbeam · gougedCABIN FLOOR BEAM AT STA.520 - RBL 12IN. HAS GOUGES. FLOOR PNL 231UF REPAIRED CABIN FLOOR BEAM AT STA.520 - RBL 12IN. PER EA 20-153-01542.SDR FDEA2020082621983Floorbeam · corrodedFLOOR BEAM NUTPLATE IS CORRODED BS 1681-RBL47. REMOVED NUTPLATE BRACKET IAW B757 SRM 51-40-02. MAT ID 7075-T6 ALUMINIUM SHEET PO NR 964704.1, IAW BOEING PL 146N5693 REV C AND BOEING DWG 146N5693 REV B. FABRICATED NUTPLATE STRIP IAW BOEING DWG 146N5693 REV B.SDR SWAA2021071410301Floor Support · crackedFORWARD CARGO AFT AT STA 540 UPPER RIGHT SIDE PANEL BREAK SUPPORT CRACK. / REMOVED AND REPLACED FORWARD CARGO AFT AT STA 540 UPPER RIGHT SIDE PANEL BREAK SUPPORT IAW AMM 53-21-00 AND SRM 51-40-02SDR SWIA202053004Floorbeam · damagedFASTENER HOLES ON INBOARD SIDE OF RBL 9 AND LBL 9 AT FS 280 FOUND TO BE OVERSIZED. C-CHECK RO 10/1/2020. REPAIRED FASTENER HOLES ON INBOARD SIDE OF RBL 9 AND LBL 9 AT FS 280.0, IAW REO. COMPLIED WITH TASK CARD AND M-337 ATTACHED. WEIGHT AND BALANCE NOT AFSDR FDEA202008212010Floorbeam · corrodedCTR WING AREA CORROSION ON FLOOR SUPPORT STA 1219 RBL 78-106 (MARKED NR 1). MAIN DECK FLOOR SUPPORT AT STA 1219 RBL78-106 (PNR WSP0711-509). REMOVED AND REPLACED WITH NEW FLOOR SUPPORT, IAW MD10-10 SRM 51-35-01 VOL 2 (REFER JPF FOR FABRICATION OF FLOOR SUPPOSDR SWAA2020090910099Floorbeam · corrodedCORROSION ON LATERAL BEAM AT COCKPIT BS 270 RBL 10-LBL 10 WL 207.5. REPAIRED CORROSION ON LATERAL BEAM AT COCKPIT BS 270 RBL10-LBL10 WL 207.5, PER EA 1-A53-13812-REV 2.SDR SWAA2021072209593Floorbeam · corrodedFWD PIT STA 500I LATERAL FLOOR SUPPORT UPPER SURFACE CORRODED FROM LBL 24 TO RBL24 AT WL 155 / EVALUATED CORROSION ON LOWER BULKHEAD SUPPORT AT STA 500I LBL 24 - RBL 24 NO PUBLISHED LIMITS IN SRM. REMOVED AND REPLAED RAIL ASSY IAW SRM 51-40-02-0G-0 AND BOEING SDR SWIA202053152Attach Angle · corrodedMAIN AVIONICS BAY FLOORBOARD SUPPORT ATTACH ANGLE AT FS 280.00 CORRODED. C-CHECK RO 10/9/2020. REMOVED AND INSTALLED NEW FLOORBOARD SUPPORT ANGLE AT FS 280, REF DWG CRJ900 SRM. COMPLIED WITH.SDR DALA202008242843Floorbeam · corrodedCORROSION FLOOR STRUCTURE LOCATED AT FR 16 HARD POINT AND Y1292 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM LOCATED AT FR12 TO FR24 AND Y1292 IN PASSENGER CABIN (1EA) AS PER A319 SRM 51-72-11 AND DRAWING #D53112812, ISSUE E.SDR SWAA2021072209701Floorbeam · corroded***CORROSION*** ON FLOOR SUPPORT SPLICE AT ACB BS767+6 LBL19 TO RBL19 WL156. / REMOVED AND REPLACED ACB FLOOR SUPPORT SPLICE BS 767+6 LBL 19 - RBL 19 WL 156 I.A.W AMM 25-52-10-400-801
Back to JASC 5315