SDR DALA2016102607669Floorbeam · corrodedMAIN CABIN, CORROSION ON FLOORBEAM STA 324 RBL 61. REMOVED REPAIR, FABRICATED REPAIR AND INSTALLED IAW SRM.SDR ASAA2015022510910Floorbeam · corrodedCORROSION ON FLOORBEAM STA 947.5, AT LEFT AFT LAV INBD AFT FLOOR MOUNT. ACFT GROUNDED. REMOVED DAMAGE FLANGES AND PERFORMED FLOORBEAM REPAIR IAW SRM 53-70-51-2R-5. REMOVED INBD LAV MOUNT IAW SRM 51-40-02. REMOVED DAMAGE, CUTOUT, AS REQUIRED IAW SRM 53-70-5SDR DALA2015022701823Floorbeam · corrodedMAIN CABIN, CORROSION ON FLOOR SUPPORT BS 405, BETWEEN RBL 24 & 45. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. DRILLED AND DEBURRED NEW FLOOR SUPPORT IAW SRM AND INSTALLED.SDR DALA2015022601681Floorbeam · corrodedMAIN CABIN FLOORBEAM NUT PLATE CORRODED STA 1680, RBL 25. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR AND INSTALLED.SDR SWAA2015042738991Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CHANNEL CORRODED AT BS 772, LBL 7. REPAIRED CHANNEL IAW SRM & DWG.SDR SWAA2015041438500Floorbeam · corrodedAFT CARGO BAY FLOORBEAM ANGLE CORRODED AT BS 772, RBL 3. REPAIRED ANGLE IAW SRM & EA.SDR SWAA2015040738200Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 727D+5, RBL 8. REPAIRED ANGLE IAW SRM.SDR SWAA2015040738199Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 727D+5, RBL 3. REPAIRED FLOORBEAM IAW EA.SDR SWAA2015040738195Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 772, LBL 3. REPAIRED ANGLE IAW EA.SDR CALA2015022400124Floorbeam · corrodedCABIN STATION 325, LBL 20 - 55 FLOORBEAM UPPER CHORD CORROSION FOUND. CORROSION REMOVED IAW SRM 51-10-02. BLEND OUT AREA D0.030" W1" L2", ORG THK0.090", OUT OF SRM 53-00-51 ALLOWABLE DMG 1 FIG 101 LIMIT. UPPER CHORD CORRODED, AREA REPAIRED IAW SRM 53-00-51 SDR CALA2015022400123Floorbeam · corrodedCABIN STATION 303, LBL 15 - 55 FLOORBEAM UPPER CHORD CORROSION FOUND. REPAIRED IAW SRM 53-00-51 REPAIR 1 FIG 201 AT LBL 8 - 64. FLOORBEAM UPPER CHORD CORROSION REMOVED IAW SRM 51-10-02. BLEND OUT AREA D0.060 INCHES, ORG THK0.090 INCH, L3" W1" OUT OF SRM53-0SDR SWIA201540848Floorbeam · crackedFS 280 BEAM CLIP AT RBL 9 IS CRACKED. C-CHECK, RO: 03/10/2015, R & R FS 280, RBL 9 INBD CLIP, PN 601R31113-58 IAW REO AND SRM.SDR C77A20150223004Floorbeam · corrodedAFT CABIN RT FLOORBEAM, PN 170-65669-004, HAS CORROSION AT FRAME 7, X= 23865 Y= 260.4. R & R RT FLOORBEAM IAW SRM 51-41-01 & 51-43-01 ON WO 6213171H8 IAW 53MR-094 REV 4 WO 1832102.SDR C77A20150223003Floorbeam · corrodedAFT CABIN LT FLOORBEAM HAS CORROSION AT FRAME 87, X=23865, Y= -260.4. R & R LT FLOORBEAM IAW SRM 51-41-01 & 51-43-01 ON WO 6213171H7 IAW EO E170-53MR-093 REV 3 WO 1832163.SDR SWAA2015041338423Floorbeam · corrodedFLOORBEAM T CAP CORRODED AT BS 986.5. REPAIRED T CAP IAW EA.SDR ASOA2015031212375Floorbeam · corrodedFS 280 CRAWLWAY FLOOR SUPPORT ANGLE HAS CORROSION. BEYOND ALLOWABLE LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED CRAWLING FLOOR SUPPORT ANGLE AT FS280 IAW SRM 51-42-06-001-001-A01. LOCATED, DRILLED AND DEBURGED FASTENER HOLES IN NEW FLOOR SUPPORT ANGLE IAW SDR SWAA2015022636919Floorbeam · corrodedRIGHT FLOORBEAM INBD SEAT TRACK UPPER T CAP CORRODED AT BS 328. REPAIRED T CAP IAW SRM.SDR SWAA2015032437749Floorbeam · corrodedPASSENGER CABIN UPPER FLOORBEAM T CAP CORRODED AT BS 1016, BETWEEN LBL 4 - 10. REPAIRED T CAP IAW SRM & EA.SDR WX0A2015030572449Floorbeam · corrodedFLOORBEAM AT FS 256 HAS CORROSION BETWEEN LBL 22 & RBL 22. FABRICATED & INSTALLED FLOOR SUPPORT IAW SRM 51-10-4 & 51-30-5 WITH 2 1/2 LENGTH 1 1/2 ORIGINAL .070 REMAINING 0 LEVEL 2. WORK ACCOMPLISHED ON WO 243433 M301 ITEM 529 & WO 1011609 2000-0182.SDR WX0A2015030572448Floorbeam · corrodedFLOORBEAM AT FS 256 HAS CORROSION BETWEEN RBL 22 & RBL 44. FABRICATED & INSTALLED FLOOR SUPPORT IAW SRM 51-10-4 & 51-30-5, WITH 4½ LENGTH 1½ ORIGINAL .070 REMAINING 0. LEVEL 2 WORK ACCOMPLISHED ON WO 243433 M301 ITEM 530 & WO 1011609 2000-0183.SDR SWIA201540792Floorbeam · crackedCRACK ON FLOOR SUPPORT FLANGE FS 621, LBL 36, C-CHECK, RO 2/26/15. REMOVED CRACKED ANGLE AND INSTALLED NEW FLOOR SUPPORT ANGLE 601R-53-61-117, REF: REO AND SRM.SDR WX0A2015022772442Floorbeam · corrodedCORROSION UNDER FWD FLANGE OF 1681 FLOORBEAM AT NUTPLATE HOLE, MATERIAL LOSS OUT OF LIMITS. DAMAGE CUT OUT & REPAIRED IAW STM 53-60-51 REPAIR 3 IAW TO NRC 3574250.SDR DALA2015022001508Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y512 LOCATED BETWEEN FRAME 64 AND FRAME 70 AT AFT GALLEY AREA L=2", W=1, D=0.004". REPLACED FLOORBEAM Y512 LOCATED BETWEEN FRAME 64 AND FRAME 70 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015022001506Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1292 LOCATED BETWEEN FRAME 64 AND FRAME 66+5" AT AFT GALLEY AREA L=0.500", W=0.250", D=0.001". REPLACED FLOORBEAM -Y1292 LOCATED BETWEEN FRAME 64 AND FRAME 66+5" AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D5SDR DALA2015022001503Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y1292 LOCATED BETWEEN FRAME 64 AND FRAME 66+5" AT AFT GALLEY AREA L=0.500", W=0.300", D=0.002". REPLACED FLOORBEAM +Y1292 LOCATED BETWEEN 64 AND FRAME 66+5" AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472216SDR DALA2015022001501Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y1225 LOCATED BETWEEN FRAME 66+5" AND FRAME 67+15" AT AFT GALLEY AREA L=0.500", W=0.300", D=0.002". EVALUATED FLOORBEAM +Y1225 LOCATED BETWEEN FRAME 66+5" AND FRAME 67+15" AT AFT GALLEY AREA IAW SRM 51-72-11 ASDR DALA2015022001500Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y1162 LOCATED BETWEEN FR 67+15" AND FRAME 69 AT AFT GALLEY AREA L=0.200", W=0.150", D=0.001". REPLACED FLOORBEAM +Y1162 LOCATED FRAME 67+15" AND FRAME 69 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015022001499Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1225 LOCATED BETWEEN FRAME 66+5" AND FR.67+15" AT AFT GALLEY AREA, L=2" W=0.800", D=0.003", SSI 534147. REPLACED FLOORBEAM -Y1225 LOCATED BETWEEN FR 66+5" AND FR 67+15" AT AFT GALLEY AREA IAW SRM 51-72-11 AND SDR WVER0218201500003Floorbeam · corrodedBS 280 FLOORBEAM CORRODED.SDR WX0A2015022772439Support · crackedVERTICAL FLOORBEAM SUPPORT CRACKED FS 905 LBL 44. REMOVED, FABRICATED & INSTALLED NEW SUPPORT IAW SRM 51-30-5, 51-10-4 & 51-10-3.SDR AALA20150218012Floorbeam · crackedCRACK IN FLOORBEAM CORD, INSTALLED A STRAP & SPLICE.SDR SWAA2015021936728Strap · crackedFLOORBEAM STRAP CRACKED AT BS 328, LBL 12. REPAIRED STRAP IAW SRM.SDR WVER0218201500002Floorbeam · damagedFLOORBEAM ANGLE BS 280, RBL 17.46 HAS ELONGATED HOLES.SDR SPUY201502180026Floorbeam · crackedMAIN CARGO COMPARTMENT FLOORBEAM CRACKED 3", BS 1183, RBR 24.5 NEAR WL 263.SDR UIEA2015022000152Floorbeam · corrodedFOUND MAIN DECK FLOORBEAM CORROSION LOCATED STATION 980, LBL 90. (REPAIRED DAMAGED IAW EI NO T2015A53B-296 REV 1. JOB COMPLETED & CONDITION CHECKED NORMAL.SDR UIEA2015022000143Floorbeam · corrodedFOUND MAIN DECK FLOORBEAM CORROSION AT STATION 1580, RBL 95. REPAIRED DAMAGED AREA IAW SRM 53-00-51-2R-3 REPAIR 3 REV 71. JOB COMPLETED & CONDITION CHECKED NORMAL.SDR UIEA2015021900134Floorbeam · corrodedCORROSION MAIN DECK CARGO FLOORBEAM. CORROSION AT STATION 1860, RBL 6. REMOVED CORROSION & MEASURE REWORKED AREA, DEPTH=0.012 INCHES, LENGTH=1 INCH & WIDTH=1 INCH IS WITHIN ALLOWABLE LIMIT IAW SRM 53-00-51-1A-1 FIGURE 101 REV 71. JOB COMPLETED & CONDITION CSDR WVER0217201592901Angle · damagedANGLE AT BS 280, LBL 17.46, HAS ELONGATED HOLES.SDR ASOA2015030512337Floorbeam · corrodedFLOORBOARD SUPPORT ANGLE AT FS 280.00 HAS 2 CORRODED HOLES, SCREW HOLES. R & R FLOORBOARD SUPPORT ANGLE WITH NEW SUPPORT ANGLE AT FS 280.00 IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-21-001-001-801 DWG CC670-34256-3.SDR ASOA2015032012444Floorbeam · crackedFS 280 BEAM IS CRACKED BETWEEN 2 RIVETS AT UPPER FLANGE JUST OTBD OF LBL 9. REPAIRED FS 280 BEAM IAW REO:601R-53-11-138 AND EC/TC REO:601R-53-11-138.SDR SWAA2015022536887Floorbeam · crackedFLOORBEAM CRACKED AT BS 294.5, RBL 53. REPAIRED FLOORBEAM IAW SRM.SDR UIEA2015021800131Floorbeam · corrodedMAIN DECK STATION 980 LBL 67 FLOORBEAM & UPPER CHORD FOUND CORROSION. REPAIRED IAW SRM 53-00-51 REPAIR 3.SDR DALA2015021701369Floorbeam · corrodedCORROSION AT FLOOR SUPPORT BS 522. THE FLOOR SUPPORT WAS REPAIRED IAW SRM 53-01, FIG 2, SHEET 4, 51-10-3, PAR 21 AND 14, AND 38 OTHER AREAS WAS REMOVED CORROSION IAW SRM 51-10-3, PAR 26.SDR USAA2015022000008Floorbeam · corroded1S CHECK, CORROSION ON FLOORBEAM BETWEEN FRAME 75 & 76 AT STRINGER 26R. R & R FLOORBEAM IAW SRM 51-42-11.SDR MASA2015021612904Floorbeam · crackedTEMP REPAIR TO FS 280 CROSSBEAM CRACKED BETWEEN LBL11.128 AND RBL11.128. PERMANENT REPAIR EXTENDED AND ADDITIONAL 6000 FLT HRS. PERMANENT REPAIR DUE AT 32540 FH. EDDY CURRENT INSPECTION COMPLETED ON 2/14/2015. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR FDEA201502130527Crossbeam · corrodedAFT CARGO FLOOR FRAME 63 CROSSBEAM CORRODED BETWEEN Y140 & Y805. REPAIRED THE CROSSBEAM PER SRM 53-10-15 FIG.209.SHT.1SDR FDEA201502130526Crossbeam · corrodedAFT CARGO FLOOR FRAME 61 CROSSBEAM CORRODED BETWEEN -Y805 & Y805. REPAIR THE CROSSBEAM PER SRM 53-10-15 FIG.209 SHT.1SDR DALA2015021401255Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM LOCATED BETWEEN -Y254 AND -Y160, FRAME 66. REPLACED FLOORBEAM IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2015031202125Floorbeam · corrodedBS 365 FLOORBEAM PREVIOUS REPAIR CORRODED FROM LBL 10 TO RBL 60. CORRECTIVE ACTION: REMOVED PREVIOUS REPAIR, INSPECTED, NO CRACKS NOTED. FABRICATED REPAIR AND INSTLLED IAW SRM.SDR SWIA201540769Floorbeam · crackedRT FLOORBEAM AT FS 274, RBL 11 CRACKED. C-CHECK, RO: 02/23/2015, REPAIRED RT FLOORBEAM AT FS 274 IAW REO.
Back to JASC 5315