JASC 5315
Service difficulty reports · 44,205
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202508269578Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKS INDICATION FOUND ON OPEN HOLE ON CENTER WING BOX FR36 FRONT SPAR VERTICAL STRINGER 4 ZONE 1, CRACKS DIRECTION AT 12 O CLOCK, 5 O CLOC K AND 3 O CLOCK , D= 0.112 INCH. MAINTENANCE ACCOMPLISHED PERMANENT REPAIR (PARTIAL REPLASDR CALA2025071706651Floorbeam · corrodedAFT WET AREA RT FLOORBEAM BS 947 HAS SURFACE CORROSION. DAMAGE FOUND TO BE OUT OF LIMITS PER B737-800 SRM 53-70-51-1A-1. REMOVED AND T-ANGLE REPAIR PER B737-800 SRM 51-40-02. REFABRICATED AND REPLACED T-ANGLE REPAIR PER B737-800 SRM 53-70-51-2R-5.SDR JR2R20250701209Floorbeam · crackedFWD SIDE OF FLOOR BEAM 12 ANGLE CRACKED UNDER PILOTS SIDE COUNSIL IN THE FLIGHT DECK IS CRACKED AT INTERCOSTAL.SDR CALA2025071506573Floorbeam · corrodedCORROSION AROUND FASTENER HOLE/BEAM UPPER SURFACE AT STA328 RBL 40.SDR DALA2025070104885Floorbeam · corroded(LOG 1055538) CORROSION WAS FOUND BELOW FITTING ON BEAM (UPPER FLANGE) OF BS947.5 BTW RBL 54 AT W2. BEAM OF BS947.5 BTW RBL 54 AT W2 WAS REPAIRED PER B737-800 SRM 53-70-51-2R REPAIR 5.SDR VNAA20250629035Floorbeam · corrodedF.S. 280 FWD J ANGLE IS CORRODED OUT OF LIMITS BETWEEN LBL9 TO RBL 9. REMOVED UNSERVICEABLE/CORRODED F.S. 280.00 J ANGLE P/N CC670-34095-3 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND CRJ 900 SRM 51-42-21-001-001-A01. INSTALLED NEW SERVICEABLE F.S. 280.00 J ANGLSDR VNAA20250629034Floorbeam · corrodedR/H F.S. 280 BEAN HAS TWO CORRODED RIVETS BETWEEN RBL 9 TO RBL 18. REMOVED 2 EACH CORRODED FASTENERS IAW CRJ900 SRM 51-42-13-001-001-A01. INSTALLED 2 NEW FASTENERS. APPLIED TO FASTENERS. IAW CRJ900 SRM 51-42-13-001-001-A01, 51-25-16-001-001-A01.SDR VNAA20250629012Floorbeam · crackedFLIGHT DECK FLOORBEAM AT RBL 12 FWD SIDE OF FS280 IS CRACKED. REPAIRED BY CUTTING AWAY DAMAGED PORTION AND INSTALLING REPAIR PARTS IAW MHIRJ REO 690-53-11-1976 REV-- DATED 2025-04-25SDR VNAA20250629011Floorbeam · crackedFLIGHT DECK FLOORBEAM AT LBL 12 FWD SIDE OF FS280 IS CRACKED. REPAIRED BY CUTTING AWAY DAMAGED PORTION AND INSTALLING REPAIR PARTS IAW MHIRJ REO 690-53-11-1976 REV-- DATED 2025-04-25.SDR SIMA20250628004Floorbeam · corrodedRH CENTER FLOOR BEAM HAS CORROSION AT FR 17, JUST FWD OF THE SEAT TRACK SSI 53-10-027. (MAJOR REPAIR) (LEVEL 2 CORROSION). ACCOMPLISHED A PERMANENT REPAIR ON RH CENTER FLOOR BEAM CORROSION AT FR 17, JUST FWD OF THE SEAT TRACK IAW ERS-EJ-53MR-5233SDR SIMA20250628003Floorbeam · corrodedSSI 53-10-027 FR 19 LH NUTPLATE SUPPORT BRACKET HAS CORROSION AROUND SCREW HOLE. (LEVEL 2 CORROSION). RAR FR 19 LH NUTPLATE SUPPORT BRACKET IAW ERJ 170 SRM 51-40-08.SDR SIMA20250627004Floorbeam · corrodedSSI 53-23-005 RH FLOOR CROSS BEAM IS CORRODED AT FR 84 (MAJOR REPAIR) (LEVEL 2 CORROSION). ACCOMPLISHED A PERMANENT REINFORCEMENT REPAIR ON RH FLOOR CROSS BEAM AT FR84 IAW ERS-EJ-53MR-5236SDR SIMA20250627003Floorbeam · corrodedSSI 53-23-005 ? RH FLOOR SILL AT FR 84 TO CROSS BEAM IS CORRODED (LEVEL 2 CORROSION) RAR RH FLOOR SILL AT FR84 TO CROSS BEAM IAW ERJ 170 SRM 51-40-08SDR JJBA20250711025Floorbeam · corrodedAT FRAME 19 MIDDLE FLOOR SUPPORT CAP IS CORRODED. REMOVED CORROSION AT FRAME 19 MIDDLE FLOOR SUPPORT CAP. REMOVED AND LOCATED AND DRILLED AND INSTALLED NEW PARTSDR JJBA20250711024Floorbeam · corrodedAT FRAME 20 IB FLOOR SUPPORT CAP PLATE IS CORRODED. REMOVED CORROSION AT FRAME 20 IB FLOOR SUPPORT CAP PLATE. REMOVED AT FRAME 20 IB FLOOR SUPPORT CAP. LOCATED, DRILLED AND INSTALLED NEW PART.SDR DALA2025070104881Floorbeam · corroded(LOG 1049586) CORROSION ON Z ANGLE FLOOR SUPPORTS (2 EAS) BTW STA 992 LBL 43 AND RBL 43 AT PAX CABIN. Z ANGLE FLOOR SUPPORTS (2 EAS) BTW STA 992 LBL 43 AND RBL 43 AT PAX CABIN WERE REPLACED AND INSTALLED PER B 737-800 SRM 51-40-02-0G.SDR CALA2025070106107Floorbeam · damagedSTA 947/LBL 4'-11' STA 947/RBL 5' ELONGATED HOLES AND CORROSION. ACCOMPLISHED REPAIR AT STA 947.50 FROM LBL 4 - LBL 11 IAW EC/RA 5370-01181, B737/800 SRM 53-00-51-2R-1.SDR SIMA20250627001Floorbeam · corrodedAFT WET AREA BEAM CORRODED AT FR 86 Y-11" (MAJOR REPAIR) (LEVEL 2 CORROSION) BLENDED CORROSION ON BEAM AT FRAME 86 Y-11" IAW E-175 SRM 51-10-03, ORIGINAL THICKNESS .076", MATERIAL LOSS .072", FOUND TO BE OUT OF ALLOWABLE LIMITS IAW E-175 SRM 51-75-16. LOCATED SDR N6WA2025062705Crossbeam · corroded280 CROSSBEAM AT LBL9 AND RBL9 HAS CORROSION. REMOVED AND REPLACED THE 280 CROSSBEAM IAW CRJ SRM 51-42-06.SDR SWAA2025072985848Floorbeam · crackedCRACKED ON FLOORBEAM AT BS 328; RBL 18.5; WL208. REMOVED AND REPAIRED DAMAGE PART OF THE UPPER FLANGES FLOOR BEAM BS328 FROM RBL1-RBL60 WL208 I.A.W SRM 53-10-51-2R-7 REPAIR 7 ALTERNATIVE 2.SDR SWAA2025072285897Floorbeam · crackedCRACK BRAKE PANEL FLOOR STRUCTURE LOCATED STA540 AND LBL1 AT PASSENGER CABIN. REPLACED FLOORBEAM IAW SRM 51-10-02 ITEM 9 &INSTALLED FASTENERS IAW DRAWING 143A5240 ; SHEET 14; REV - AND SRM 51-40-02.SDR SIMA20250626004Floorbeam · corrodedAFT GALLEY FLOOR STRUCTURE, THE LH FLOOR BEAM HAS CORROSION AT FR 87. SSI 53-23-005. (MAJOR REPAIR) (LEVEL 2 CORROSION). RAR THE AFT GALLEY FLOOR STRUCTURE LH FLOOR BEAM BETWEEN FR 86-89 IAW ERJ 175 SRM 51-40-08SDR AALA202507217514Floorbeam · elongatedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLE ON SPLICE O/B SIDE LOWER LOC. FLOOR BEAM +Y765 AT LEVEL FR64 AFT GALLEY AREA MEASURE OF ELONGATE HOLE ON SPLICE IS 0.263 INCH. MAINTENANCE REPLACED SPLICE O/B SIDE LOWER AND FASTENERS LOC. FLOOR BEAM Y765 AT LEVEL SDR JJBA20250711029Floor Support · corrodedLH IB FLOORSILL CAP FROM 23 TO 24 IS CORRODED. REMOVED CORRODED LH IB FLOOR CAP FROM 23 TO 29. RECEIVED, LOCATED, DRILLED, AND INSTALLED NEW FLOORSILL.SDR SIMA20250626001Floorbeam · corrodedAFT WET AREA CORROSION AT LH FLOOR BEAM FR86-87 @Y=-10. (MAJOR REPAIR) (LEVEL 2 CORROSION). BLENDED CORROSION ON LH FLOOR BEAM PER EMB 175 SRM 51-10-03. BLENDED AREA MEASURES (L: .50? W: .50? D: .030?) AND IS FOUND TO BE OUT OF LIMITS PER EMB 175 SRM 51-75-16.SDR DALA2025063004861Floorbeam · corrodedSHIP 6807 CORRIOSION FOUND AT STA 1000 L/H SIDE UNDER FLOOR BEAM. CORRECTIVE ACTION: REPAIRED CORROSION ON LTR TANK UPPER SKIN AT STA 1000 L/H UNDER STUB BEAM PER ER/A 626574-14. (1047165)SDR FDEA202506261063Floorbeam · corrodedMCC FLOOR BEAM SUPPORT UPPER HAS CORROSION RBL 8 -14 STA 560. PERFORMED FLOOR BEAM REPAIR AT MCC STA 560 FROM RBL 15.8 TO LBL 11.1 ON UPPER CHORD IAW B 757 SRM 53-00-51-2R REPAIR 10. THIS IS MAJOR REPAIR.SDR FDEA202506261060Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR BEAM SUPPORT LOWER CHORD NUT PLATES CORRODED AT BS 1560 BETWEEN RBL 45.75 TO LBL 45.50.SDR SWAA2025072985416Floorbeam · corrodedCORROSION FLOOR STRUCTURE FLOOR BEAM LOCATED BS 986.5 AND RBL 43 WL 208.1 AT AFT GALLEY AREA. PERFORMED REPAIR FLOOR STRUCTURE FLOOR BEAM LOCATED BS 986.5 AND RBL 43 WL 208.1 AT AFT GALLEY AREA IAW SRM 53-70-51-2R-6 REPAIR 6.SDR AALA202507047345Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON CENTER WING BOX FR36 FRONT SPAR VERTICAL STRINGER N5 ZONE 1, CRACK DIRECTION AT 12 O CLOCK D= 0.091 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON CENTER WING BOX FR36 FRONT SPAR VERTICAL STRINGER 5 (BEAM SDR DALA2025063004860Floorbeam · corrodedSHIP 6807 CORRIOSION FOUND AT STA 1020 L/H SIDE UNDER FLOOR BEAM. CORRECTIVE ACTION: REPAIRED CORROSION FOUND ON CTR TANK UPPER SIN AT STA 1020 L/H UNDER FLOOR BEAM PER PRI ER/A 626574-14. (1045541)SDR DALA2025063004838Floorbeam · corroded(LOG 1045539) CORROSION ON FLOOR BEAM UPPER AND LOWER AREAS STA 986.5 AT W2. PREVIOUS REPAIR ON FLOOR BEAM STA 986.5 AT W2 WAS REPLACED PER ERA 583800-14 REV. ORIGINAL, SECTION I: PERMANENT REPAIR.SDR DALA2025063004836Floorbeam · corroded(LOG 1044655) CORROSION ON FLOOR SUPPORT UPPER AND LOWER AREAS STA 948.5 FROM 54 RBL TO 50 RBL AT W2. FLOOR SUPPORT STA 948.5 FROM 54 RBL TO 50 RBL AT W2 WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR AALA202506303361Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 FRONT SPAR VERTICAL STRINGER 3 ZONE 1 CRACK DIRECTION AT 12 O CLOCK D=0.089 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FR36 FRONT SPAR VERTICAL STRINGER 3 (BEAM Y254) IAW EA 364522.SDR COEA2025103001919Floorbeam · corrodedWO 264878 NR 100023 HEAVY CHECK COE/MAJOR REPAIR DISCREPANCY: INTERNAL FUSELAGE FLOORBEAM 40 HAS LEVEL 2 CORROSION BETWEEN STRINGERS 16L AND 16R. CORRECTIVE ACTION: REPAIRED PER ATR42 SRM 51-25-01.SDR AALA202506308263Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON FR36 FRONT SPAR VERTICAL STRINGER N4 ZONE 1 CRACK DIRECTION AT 12 D=0.095 IN. MAINTENANCE PERFORMED PERMANENT REPAIR ON FR36 FRONT SPAR VERTICAL STRINGER 4 (BEAM Y-254) IAW EA 364522 PART D AND DWG R57112SDR CALA2025062605915Floorbeam · corrodedCABIN FLOORBEAM HAS BARE METAL STA 1661 LBL-57" TO RBL-57". REPAIRED CABIN FLOORBEAM BS 1661 LBL-57 TO RBL 57 IAW EC/RA 5360-01972 THIS IS A CATEGORY A REPAIR NO DIPS REQUIRED F OR INSPECTION. RII VERIFIED AND APPROVED.SDR VNAA20250625003Floorbeam · corrodedFOUND CORROSION ON FS 280 "J" ANGLE. UPON FURTHER INVESTIGATION ON FS 280 "J" ANGLE FOUND TO BE OUT OF LIMITS IAW CRJ 700 SRM 53-00-00-101-001-A01. LOCATED AND DRILLED NEW J ANGLE P/N CC670-34095-1SB IAW CRJ-700-SRM-51-40-11-001-001-A01. INSTALLED FS 280 NEWSDR VNAA20250625002Floorbeam · corrodedFOUND CORROSION ON FS 280 R/H CROSS BEAM. UPON REMOVAL OF R/H CROSS BEAM FOUND R/H CORROSION CAP ANGLE DAMAGE REQUIRES REPLACEMENT. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE RH CORROSION CAP ANGLE P/N CC670-34096-2 IAW CRJ 700 SRM 51-42-06-001-001- A01.SDR VNAA20250625001Floorbeam · corrodedFOUND CORROSION @ L/H F.S.280 BEAM. INSTALLED NEW FS 280 LH CROSSBEAM P/N CC670-34094-2 AND INSTALLED NEW LH CORROSION CAP ANGLE PN CC670-34096-1 IAW CRJ 700 SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01 & 51-42-22-001-001-A01.SDR ASAA2025062359921Floorbeam · crackedSTA 540 PANEL BREAKS CRACKED LBL 44 TO RBL 22. GROUNDED - YES. REMOVED AND REPLACED 3EA PANEL BREAKS AT STA 540 FROM LBL 44 TO RBL 22 I.A.W. B737-700 SRM 51-40-02-OG-0.SDR SWAA2025072984620Floorbeam · crackedCRACK FLOORBEAM LOCATED BS 294.5 AND RBL 52 FWD GALLEY AND LAV. PERFORMED PERMANENT REPAIR CAT A; FLOOR BEAM LOCATED BS 294.5; BTW RBL 20 TO RBL 60 IAW B737-700 SRM 53-10-51-2R-16 REPAIR 16.SDR AALA202507110608Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM AT BS 986, RBL 50. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-6 ALTERNATIVE 4.SDR AALA202507110368Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM AT BS 986, LBL 50. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-6 ALTERNATIVE 4.SDR SCNA20250707245Floorbeam · corrodedCORROSION IN BEAM OF FLOOR SUPPORT AT LBL 44 & STA 986 AT W2 PASSENGER CABIN. BEAM OF FLOOR SUPPORT AT LBL 44 & STA 986 AT W2 PASSENGER CABIN WAS REPAIRED PER B737-800 SRM 53-70-51-2R-6 REPAIR 6.SDR ASAA2025062359152Floorbeam · crackedSTA 540 PANEL BREAKS CRACKED LBL 44 TO RBL 22. GROUNDED - YES. REMOVED AND REPLACED 3EA PANEL BREAKS AT STA 540 FROM LBL 44 TO RBL 22 I.A.W. B737-700 SRM 51-40-02-OG-0.SDR CALA2025062605898Floorbeam · corrodedAFT WET AREA FLOOR BEAM STA 987 RBL 43 UPPER FLANGE HAS CORROCION. ACCOMPLISHED FLOOR BEAM REPAIR AT AFT WET AREA STA 986.5 RBL 43 IN REF SRM 53-70-51-2R-6 REPAIR 6.SDR SWAA2025071584306Floorbeam · crackedCRACK BREAK PANEL ON FLOOR STRUCTURE LOCATED STA 540 BTW BL 0 TO RBL 24.75 AT PASSENGER CABIN. REPLACED BREAK PANEL LOCATED ON FLOOR STRUCTURE LOCATED ON STA 540 BTW BL 0 TO RBL 24.75 AT PASSENGER CABIN IAW SRM 51-40-02 AND DWG 143A5240; SHEET: 13 AND REV: -.SDR SWAA2025071584304Floorbeam · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED STA 695 AND LBL 24.75 AT PASSENGER CABIN. REPLACED SUPPORT BRACKET AND NEW FASTENERS ON FLOOR STRUCTURE LOCATED STA 695 AND LBL 24.75 AT PASSENGER CABIN IAW SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 273A9110 SHEET 6 REV: A.SDR AALA202506240761Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE BREAK ASSEMBLY PANEL AT BS 540, RBL 10. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.
Back to JASC 5315