SDR SWAA116398Angle · puncturedDURING SCHEDULED 12Y CHECK, FOUND AFT CARGO COMPARTMENT RT Z-ANGLE PUNCTURED AT BS 757. REMOVED AND REPLACED Z-ANGLE IAW SRM.SDR A6WA201140874Floorbeam · crackedFS280, RBL 9, OTBD CLIP CRACKED. REMOVED UNSERVICEABLE CLIP AT FS 280, LBL 9 OTBD IAW SRM 51-42-21. FABRICATED CLIP IAW SRM.SDR USAA2011091500028Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR16, Y503.2. REPLACED FLOORBEAM AT FR16, Y503.2 IAW A319 SRM 53-11-14, 51-72-11.SDR USAA2011091400015Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR20 3 INCHES AFT TO FR20 10 INCHES FORWARD, -Y254. BETWEEN FR20 3 INCHES AFT TO FR20 10 INCHES FORWARD, -Y254 IAW A319 SRM 53-11-14, 51-72-11.SDR USAA2011091400014Floorbeam · corrodedC11 CHECK - LEVEL 2 CORROSION ON FLOORBEAM BETWEEN FR12 TO FR16, -Y81. REPLACED FLOOR BEAM BETWEEN FR12 TO FR16, -Y81 IAW A319 SRM 51-72-11.SDR USAA2011091400013Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR15 TO FR21, Y254. REPLACED FLOORBEAM AT FR15 TO FR21, Y254 IAW A319 SRM 51-71-11.SDR SWAA116370Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUINDAL FLOORBEAM UPPER O/B CHORD CRACKED AT BS 727B, RBL 24. REPAIRED CHORD PER ER AND EA.SDR SWAA116357Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM T-CAP CORRODED AT BS 344, BETWEEN LBL 24 TO RBL 2. REPAIRED T-CAP PER SRM AND DWG.SDR SWAA116350Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 665, LBL 24. REPAIRED CHORD IAW EA.SDR SWAA116349Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 669, LBL 24. REPAIRED CHORD IAW EA.SDR SWAA116306Floorbeam · corrodedDURING SCHEDULED 26Y CHECK, FOUND FLOOR STRUCTURE FLOORBEAM CORRODED AT BS 986.5, RBL 43. REPAIRED BEAM IAW EA.SDR FDEA201109033655Floorbeam · corrodedBS 365 FLOORBEAM RBL 5-58 CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. REPLACED FLOORBEAM IAW SRM 53-10-51 DETAIL II. INSTALLED FLOORBEAM IAW 51-40-02. MAJOR REPAIR.SDR DALA1151193712Floorbeam · corrodedAFT CABIN FLOORBEAM 986 RBL 47 CORRODED AT NUT PLATE UPPER AND LOWER SURFACE. REPAIRED PER ERA 464736-14MA.SDR DALA1151183712Floorbeam · corrodedAFT CABIN FLOORBEAM STA 986 LBL 24-44 UPPER CAP CORRODED BEYOND LIMITS. REPAIRED PER SRM 53-70-51.SDR FDEA201109023665Floorbeam · damagedMAIN CABIN BS 480 LBL 62 - LBL 45 FLOORBEAM ATTACH FITTING HAS DOUBLE DRILLED FASTENER HOLES. REMOVED & REPLACED FLOORBEAM SUPPORT FITTING IAW DWG 53FX1469 & EA 7-5310-152436.SDR UALA2011090204725Floorbeam · corrodedCABIN FLOORBEAM STA 1661 LBL TO LBL HAS SURFACE CORROSION. MAJOR REPAIR ACCOMPLISHED: CORRODED SECTION OF FLOORBEAM UPPER CAP LBL 24 TO LBL 29 WAS CUTOUT AND REPAIR ACCOMPLISHED PER SRM REPAIR 3. WORK WAS ACP ON CAL NR 9949626.SDR USAA2011091300029Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR14, Y503.2. REPLACED FLOORBEAM AT FR14, Y503.2 IAW A319 SRM 51-72-11 & AMM 20-20-05.SDR USAA2011091300028Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR14 TO FR16, -Y81. REPLACED FLOORBEAM BETWEEN FR14 TO FR16, -Y81 IAW A319 SRM 53-11-14.SDR FDEA201109013607Floorbeam · bentAFT CARGO COMPARTMENT RT SIDE FR 63 BETWEEN SEAT TRACK 4R AND 5R, UPPER FLOORBEAM IS BENT. ACCOMPLISHED REPAIR TO AFT CARGO FR C-63 DAMAGE IAW E.A. 6-5310-152428.SDR ZZDA20110901001Floorbeam · corrodedFLOORBEAM BS 200, RBL 9 TO RBL 45, CORRODED. ACCOMPLISHED FLOORBEAM REPLACEMENT PER SRM 51-41-02.SDR USAA2011090800001Floorbeam · corrodedQ5 CHECK - LEVEL 2 GALVANIC CORROSION ON AFT CARGO FLOOR TRACK/BEAM BS 747, RBL 14. REPAIRED AFT CARGO FLOOR TRACK/BEAM IAW BOEING DRAWING 65-53844 & B737 SRM 51-10-02 & 53-00-53 REPAIR 2.SDR SWAA116280Attach Fitting · crackedDURING SCHEDULED 26Y CHECK, FOUND LONGITUDINAL FLOOR BEAM ATTACHMENT CLIP CRACKED AT BS 639, RBL 45.5. R&R CLIP IAW EO.SDR FDEA201109013626Floorbeam · corrodedSTA 377, FLOORBEAM LBL 10 - RBL 45 CORRODED. REMOVED CORRSION IAW SRM 51-10-02. ORIG MATERIAL .125 AFTER REWORK .108 AREA OUT OF LIMITS, EXCEEDS 10 PERCENT OF GAGE IAW SRM 53-00-51, FIG 101, DETAIL III. REMOVED DAMAGED FLOORBEAM IAW SRM 51-40-02. RECEIVED NESDR USAA2011091300034Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR22, -Y189. REPLACED FLOORBEAM BETWEEN FR20 TO FR22, -Y189 IAW A319 SRM 51-42-11.SDR USAA2011091300033Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR20, -Y765. REPLACED FLOORBEAM AT FR20, -Y765 IAW A319 SRM 51-72-11 & 51-42-11.SDR USAA2011091300032Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR20, -Y254. REPLACED FLOORBEAM BETWEEN FR16 TO FR20, -Y254 IAW A319 SRM 51-72-11 & 51-42-11.SDR USAA2011091300031Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR20, Y1292. REPLACED FLOORBEAM BETWEEN FR16 TO FR20, Y1292 IAW A319 SRM 51-72-11.SDR USAA2011091300030Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR24, -Y1292. REPLACED FLOORBEAM BETWEEN FR20 TO FR24, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2011091300024Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR16, -Y1292. REPLACED FLOORBEAM AT FR16, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2011091300020Floorbeam · corrodedC11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR16 TO FR21, Y254. REPLACED FLOORBEAM BETWEEN FR16 TO FR21, Y254 IAW AIRBUS DRAWING D53112807, D53112816 & D53110920.SDR ZZDA2011682Floorbeam · corrodedMAIN CABIN FLOORBEAM, BS 200, LBL 8-12, CORRODED. ACCOMPLISHED FLOORBEAM REPLACEMENT PER SRM 51-41-02.SDR AALA20110906AFW04Floorbeam · corrodedCORROSION WAS FOUND AROUND NUT PLATE CLIP ON FUSELAGE MAIN DECK FLOORBEAM AT STATION 347 RIGHT BUTLTINE 26.5. INSTALLED REPAIR STRAP PER EA B767-53-018731.SDR USAA2011090800027Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, Y765. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, Y765 IAW A319 SRM 51-72-11.SDR AALA20110831TUL02Floorbeam · damagedFLOOR BEAM DAMAGED, LOWER SIDE, STATION 665, 1 INCH RIGHT OF CENTER LINE. BLENDED OUT DAMAGE ON LOWER SIDE OF FLOOR BEAM AT STATION 665 1 INCH RIGHT OF CENTER LINE AND INSTALLED DOUBLER PER AARD53-20-00-21.SDR SWAA116274Floorbeam · looseDURING SCHEDULED SPV CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD LOOSE BETWEEN BS 727A+1735 TO BS 727A+18.5, RBL 23. REMOVED AND REPLACED CHORD PER DWG.SDR SWAA116264Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM T-CAP CORRODED AT BS 986, BL 0. REMOVED AND REPLACED T-CAP IAW EA.SDR SWAA116263Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 45. REPAIRED CHORD PER ER AND ER.SDR SWAA116240Floorbeam · crackedDURING SCHEDULED 14Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 45.5. REPAIRED CHORD PER EA.SDR SWAA116224Floorbeam · crackedDURING 24Y CHECK, FOUND FLOORBEAM CRACKED AT BS 663.75, BL 0. REPAIRED BEAM PER SRM AND DWG.SDR CALA2011083000564Floorbeam · corrodedCABIN - STA 986.5 RBL 27 - RBL 44 FLOOR SUPPORT CORRODED. CABIN STA 986.5 RBL 27 TO RBL 44 FLOORBEAM OF UPPER SURFACE COR REMOVED AND BLENDED AREA D=0.050" (ORG 0.155") X W=0.8" X L=3" OUT OF SRM 53-70-51 ALLOWABLE DAMAGE 1 FIG 103 LIMITS AND FLOORBEAM CORRODSDR USAA2011091300038Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y1227. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y1227 IAW A319 SRM 51-42-11.SDR USAA2011091300035Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, Y765 IAW A319 SRM 51-72-11.SDR USAA2011091300027Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR65 TO FR66, -Y464.8. REPLACED FLOORBEAM BETWEEN FR65 TO FR66, -Y464.8 IAW A319 SRM 51-72-11.SDR USAA2011091300026Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR68, -Y765. REPLACED FLOORBEAM BETWEEN FR64 TO FR68, -Y765 IAW A319 SRM 53-41-14.SDR USAA2011091300025Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, -Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2011091300023Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR69, -Y1162.5. REPLACED FLOORBEAM BETWEEN FR66 TO FR69, -Y1162.5 IAW A319 SRM 51-42-11.SDR USAA2011091300022Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, Y1162.5. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Y1162.5 IAW A319 SRM 51-72-11.SDR USAA2011091300021Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR67 TO FR68, Y1162.5. REPLACED FLOORBEAM BETWEEN FR67 TO FR68, Y1162.5 IAW A319 SRM 51-72-11 & AIRBUS DRAWING D53472780.SDR USAA2011091300019Floorbeam · corrodedC11 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, Y1292 IAW A319 SRM 51-72-11 & AIRBUS DRAWING D53472780.SDR SWAA116196Floorbeam · corrodedDURING SCHEDULED 26Y CHECK, FOUND FLOOR STRUCTURE BEAM LOCATED AT BS 986.5, BETWEEN RBL 43 LBL 53. REPAIRED BEAM EO.
Back to JASC 5315