SDR TWAA0017206Floorbeam · corrodedDURING OP 15 MAINT CHECK AT STA 199, BETWEEN RBL 44 AND RBL 53, THE FLOOR WEB WAS CORRODED, JUST AFT OF SERVICE DOOR. REMOVED OLD MEMBRANE AND INSTALLED PER SRM 53-01, PAGE 18.SDR TWAA0017205Floorbeam · corrodedDURING OP 15 MAINT CHECK AT STA 180 BETWEEN RBL 44 AND 52, LEVEL ONE CORROSION WAS FOUND ON FLOOR WEB IN 2 LOCATIONS, WHERE FLOOR PANEL RUBBED ON WEB. REMOVED OLD WEB. MANUFACTURED NEW PER SPM 6-70-01. INSTALLED PER SRM 53-01, PAGE 18.SDR 00FDEA00736Floorbeam · corrodedWHILE WORKING EO 7-2610-733195 PT 1 FOUND 1130 FLOORBEAM LWR CHORD CORRODED LBL 8 TO LBL 40. *S/D* REMOVED AND REPLACED PER IAW FEDEX EA 7-5310-52469.SDR 00FDEA00745Floorbeam · corrodedWHILE WORKING CORROSON BS 1166, LBL 11.5 TO LBL 5, WL 208 AT NUT PLATE HOLE IN SHEAR WEB, PREVIOUS BLEND. FOUND TOP FLANGE UNDER NUT PLATE CORRODED OUT OF LIMITS. *S/D* REPAIRED PER IAW FEDEX SRM 53-10-1, EA 7-5310-53825.SDR MWEA001081Floorbeam · damagedNO RECORD OF PREVIOUS REPAIR ON FLOOR SUPPORT BEAM AT STATION 1322 TOP EDGE FLANGE APPROXIMATELY 12 INCHES TO 24 INCHES INBOARD OF FUSELAGE SKIN RIGHT SIDE. FABRICATED AND INSTALLED REPAIR ANGLE.SDR MWEA001080Floorbeam · damagedNO RECORD OF PREVIOUS REPAIR ON FLOOR SUPPORT BEAM AT STATION 1322 TOP EDGE FLANGE APPROXIMATELY 27 INCHES INBOARD OF FUSELAGE SKIN RIGHT SIDE. FABRICATED AND INSTALLED REPAIR ANGLE.SDR MWEA001079Floorbeam · damagedNO RECORD OF PREVIOUS REPAIR ON FLOOR SUPPORT BEAM AT STATION 1338, TOP EDGE FLANGE, APPROXIMATELY 10 INCHES INBOARD OF FUSELAGE SKIN RIGHT SIDE. FABRICATED AND INSTALLED ANGLE REPAIR.SDR 00FDEA00743Floorbeam · corrodedDURING ROUTINE INSP LWR CHORD OF FLOORBEAM BS 720, BL 0 FOUND CORRODED. REMOVED, REPLACED AND FAB PER IAW BAC SRM 53-10-8.SDR USAA001803Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 24 INCHES, STATION 377.7, LBL 24 AND 48. CORROSION LEVEL 1. INSTALLED DOUBLER PER TR 53-15-02. (M)SDR TWAA0017605Floorbeam · corrodedDURING OP 16 MAINT CHECK, THE CABIN FLOORBEAM TOP HAD CORROSION AT RBL 35 AND RBL 80 IN, STA 303. REMOVED CORRODED SECTION BETWEEN LBL 35 AND RBL 80, STA 303, PER SRM 53-00-51, PAGE 201, 205. REPLACED 40 INCHES OF BEAM CAP.SDR TWAA0017516Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOORBEAM AT STA 325, RBL 64 INCHES. REMOVED CORRODED FLOORBEAM AND INSTALLED NEW SECTION OF T CAP AT STA 325, RBL 24 IN TO RBL 80 IN PER SRM 53-00-51, PAGE 201 TO 205.SDR TWAA0017515Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOORBEAM AT STA 287, LBL 36 IN TO RBL 80 IN. REMOVED CORRODED FLOORBEAM AND REPLACED FLOORBEAM T CAP AT STA 287, LBL 36 IN TO RBL 80 PER SRM 53-00-51, PAGE 201 TO 205.SDR SWAA002119Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOOR BEAM CORRODED AT BS 986.5, RBL 4. REPAIRED FLOORBEAM PER SRM.SDR AWXA0000783Floorbeam · corrodedC-CHECK CORROSION LVL 2, AFT CABIN FLOORBEAM TOP CAP CORRODED AT FS 1006, RBL 12. REMOVED DAMAGED SECTION OF FLOORBEAM IAW 737 SRM 53-00-51 FIG 202, FAB''D AND INSTALLED REPAIR WEB ANGLE IAW 737 SRM 51-70-11 FIG 1.SDR AWXA0000776Floorbeam · corrodedC-CHECK CORROSION LVL 1, AFT CABIN FS 986, BL 0 TO RBL 45 FLOORBEAM TOP CAP CORRODED; AFTER FURTHER EVALUATION, FOUND CORROSION OUT OF LIMITS AT RBL 20 AND LBL 15. CUT TOP CAP AT LBL 29 AND REMOVED EXISTING REPAIR AT LBL 27, FAB''''D REPAIR PARTS IAW 737 SRM SDR CALA0001624Floorbeam · corrodedINSPECTION FOUND GALLEY G3 LATERAL FLOORBEAM J SECTION CORRODED AT STA Y = 459, X = 18L-24R. A NEW SECTION WAS INSTALLED IAW GMM 10-900-01 AND SRM 53-11-01.SDR CALA0001622Floorbeam · corrodedINSPECTION FOUND LATERAL FLOORBEAM CORRODED AT STA Y = 459, X = 38R-41R. A SPLICE REPAIR WAS PERFORMED IAW SRM 53-30-00.SDR 2000UALA00716Floorbeam · crackedSTA 246 FLOORBEAM: THREE STIFFENERS BUCKLED IN THE FREE FLANGE AT RBL 7.88 & 26.06 AND LBL 7.88. MID-CHORD CRACKED AT RBL 43 ON THE AFT SIDE. SUPPLEMENTAL DATA UPDATE, REPLACED DISTORTED STIFFENERS PER SRM 53-10-51. REPAIRED CRACKED CHORD ANGLE PER SRM 53-10SDR MWEA00849Floorbeam · chafedFLOOR SUPPORT AND BEAM AT STATION 522 HAVE CHAFE DAMAGE BETWEEN NR 2 SEAT TRACK AND CENTER FLOOR SUPPORT. FABRICATED AND INSTALLED WEAR STRIP REPAIR.SDR MWEA00844Floorbeam · chafedCABIN FLOORBEAM STATION 598 JUST OUTBOARD OF CENTER FLOORBEAM CHAFED BEYOND LIMITS. INSTALLED FLOORBEAM REPAIR PER BOEING TELEX-MWX-ORD-00-00451H.SDR USAA001779Floorbeam · corrodedCLT - FOUND FLOORBEAM 38 INCHES, STATION 328, BL 12L TO BL 50L. CORROSION LEVEL 1. REPLACED FLOORBEAM PER SRM 53-10-9. (M)SDR AALA20001822Floorbeam · crackedTUL - FLOORBEAM CRACKED BELOW NR 6 SEAT TRACK. INSTALLED NEW FLOORBEAM PER SRM 51-30-1 AND SRM 51-30-2. (X)SDR RRXA003233Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND A TEAR IN THE CABIN FLOORBOARD FRAME AT STA 1680, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR DL73K002066Floorbeam · crackedCRACK INDICATIONS WERE FOUND ON THE BL 0.07 LONGITUDINAL FLOORBEAM BETWEEN FS 700 AND FS 717. THE CRACKS WERE REMOVED AND REPAIRED SIMILIAR TO THAT OF B737 S/B 57-1210 PER ERA 396272-14 AT HMV.SDR DL73K002065Floorbeam · corrodedTHE FS 294 FLOORBEAM WAS CORRODED ON THE UPPER CAP AT LBL 10 AND RBL 49. REPAIRED PER ERA 396233-14AD AT HMV.SDR CALA0001603Floorbeam · corrodedINSPECTION FOUND FLOORBEAM WEB CORRODED JUST UNDER SUB FLOOR MEMBRANE AT FS 200, LBL 54. REPAIRED IAW SRM 51-30-2.SDR CALA0001601Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT R-2 GIRT BAR MOUNT STA 986.5, RBL 40. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED AND REPLACED IAW ECRA 5310-03851 AND SRM 53-60-51.SDR USAA001776Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 3 INCHES BY 3 INCHES, STATION 1640 BETWEEN RBL 22 AND RBL 60. REPLACED SECTION PER TR 53-15-01 AND EA 68285. CORROSION LEVEL 1 C53-251-03. (M)SDR USAA001773Floorbeam · corrodedCLT - FOUND FLOORBEAM CRACKED 1 INCH BY 10 INCHES, STATION 312 BETWEEN LBL 30 AND RBL 12. CORROSION LEVEL 1. INSTALLED UPPER CHORD REPAIRED T-CAP PER SRM 53-10-51. (M)SDR USAA001772Floorbeam · corrodedCLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY 1 INCH EACH, STATION 987, LBL 5, 6, 16, 17, 39.5 AND RBL 5, 14.5, 23.5. INSTALLED NEW T-CAP PER TR 53-60-01 REV A. (M)SDR USAA001771Floorbeam · crackedCLT - FOUND FLOORBEAM ANGLE CRACKED 1 INCH, BS 520, RBL 45. REPLACED ANGLE PER REPAIR DOCUMENT 51-10-02. (M)SDR TWAA0017514Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON AFT CARGO FLOORBEAM CAP AT STA 1395, STRINGER 33L. REMOVED CORRODED FLOORBEAM CAP AND INSTALLED NEW SECTION FROM LBL 34 IN TO 46 IN AT STA 1395, PER SRM 53-60-51, AND SRM 51-40-02.SDR MWEA00911Floorbeam · damagedFLOORBEAM UPPER FORWARD FLANGE AT STATION 965, RBL 19 IS CUT. FABRICATED AND INSTALLED ANGLE REPAIR.SDR TWAA0017513Floorbeam · corrodedDURING OP 16 MAINT CHECK THE FWD CARGO COMPT CARGO FLOORBEAM CAP HAD CORROSION AT STA 368, RBL 36 IN, AT NUT PLATE HOLE. REMOVED BEAM CAP FROM RBL 15 TO RBL 45 AND SPLICED IN NEW PER SRM 53-00-07, FIG 204. REMOVED BAR BEAR WEB CAP FROM RBL 35 TO RBL 45 STA 3SDR UPS00434365Floorbeam · corrodedINSPECTION TYPE:C, FOUND CORRODED FLOORBEAM UPPER CHORD STA 480 RT AT RT OF STAIR CUTOUT. REPLACED EXISING PART OF UPPER DECK OF FLOORBEAM AT EXISTING SPLICE STA 480 BETWEEN RBL 57 AND 77 ACCORDING TO SRM 51-30-02.SDR USAA001766Floorbeam · corrodedCLT - FOUND BEAM CORRODED 1 INCH BY 1 INCH IN 3 PLACES, FLOORBEAM INTERCOSTAL STATION 365 TO 377.7, RBL 63. INSTALLED NEW FLOORBEAM/INTERCOSTAL PER SRM 51-40-02. (M)SDR CALA0001589Floorbeam · crackedINSPECTION FOUND A 2 INCH CRACK IN FLOORBEAM AT FS 218, LBL 44. THE FLOORBEAM WAS REMOVED AND A NEW FLOORBEAM WAS INSTALLED IAW 53-05, FIGURE A AND 51-30-2.SDR CALA0001588Floorbeam · corrodedINSPECTION FOUND RT LAV FLOORBEAM CORRODED NEAR O/B END AT CUSP, STA 1338, L18R. A REPAIR WAS INSTALLED IAW ECRA 5310-04059.SDR TWAA0017511Floorbeam · corrodedDURING OP 16 MAINT CHECK AT STA 1307 BETWEEN STRINGER 39R AND 38R, FOOT ON FLOORBEAM HAD CORROSION. REPLACED CORRODED FORMER FOOT WITH STOCK MATERIAL. PROTECTIVE TREATED NEW FORMER FOOT PER SRM 51-20-01 TABLE 1 SHEET 1 PAGE 1. SEALED PARTS FOR INSTALLATION SDR P2EA00305Floorbeam · crackedDURING Q CHECK FOUND THE PAX CABIN FLOORBEAM WEB AT BS 312 BETWEEN RBL 8 AND RBL 18 WITH CRACK L=0.50 W=0.002. REPAIRED THE PAX CABIN FLOORBEAM WEB AT BS 312 BETWEEN RBL 8 AND RBL 18 IAW BOEING FAX COO-SJO-OO-1175H DATED OCT 13, 2000 DOCUMENTED ON FAA FORM 8SDR P2EA00302Floorbeam · crackedDURING Q CHECK FOUND THE PAX CABIN FLOORBEAM WEB AT BS312 BETWEEN RBL 5 AND REL 14 WITH CRACK L=0.75 W=0.002. REPAIRED THE PAX CABIN FLOORBEAM WEB AT BS312 BETWEEN RBL 5 AND RBL 14 IAW BOEING FAX COO-SJO-OO-01182H DATED OCT 17, 2000 DOCUMENTED ON FAA FORM 81SDR USAA001730Floorbeam · corrodedCLT - Q-4, FLOORBEAM CORRODED, .25 INCH, CORROSION LEVEL 1, STA 328, BL ZERO. INSTALLED REPAIR ANGLE AND FILLER PER SRM 53-10-51 FIG 206. (X)SDR SWAA002007Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 328, RBL 25 TO RBL 56. REPAIRED FLOORBEAM PER RA 1-353-2382.SDR SWAA002006Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM AFT FLANGE CORRODED AT BS 986, RBL 24 TO RBL 48. REPAIRED FLOORBEAM PER SRM.SDR 20010111SG017Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAM 38 AND 40 CORRODED BEYOND LIMITS. REPAIRED IAW SRM 53-00-00. REF SIMA2851. (M)SDR SIMA2851Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAM 38 AND 40 CORRODED BEYOND LIMITS. REPAIRED IAW SRM 53-00-00. (M)SDR P2EA00339Doubler · crackedSJO - DURING Q-CHECK, FOUND DOUBLER ON PREVIOUS REPAIR ON FLOORBEAM AT AILERON CONTROL QUADRANT AT BS 678 LBL 24.82 CRACKED. L = 1.00 INCH. W = 0.002 INCH. IDENTIFIED AS REPORTABLE ON 11-7-00. REPLACED DOUBLER ON PREVIOUS REPAIR ON FLOORBEAM AT AILERON CONSDR SWAA001996Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM FWD FLANGE CORRODED AT BS 986, LBL 35. REPAIRED FLOORBEAM PER SRM.SDR SWAA001994Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 1016, RBL 37 TO LBL 37, WL 208. REPAIRED FLOORBEAM PER ER 00-1103 & SRM.SDR CALA0001544Floorbeam · corrodedINSPECTION FOUND RIGHT AFT LAV FLOORBEAM CORRODED AT STA 1322. THE CORRODED AREA OF FLOORBEAM WAS TRIMMED OUT IAW SRM 53-05, FIGURE 20A. A REPAIR ANGLE, SHIM, AND WEAR STRIP WERE INSTALLED IAW SRM 53-05, FIGURE 20A AND 51-10-4.
Back to JASC 5315