JASC 5315

Service difficulty reports · 44,223

Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5315'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR USAA000237Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 28 INCH BY 2 INCH, BS 328, RBL 13 THROUGH RBL 41 T-CAP. REPAIRED DOUBLER AND STRAP PER SRM 53-00-51 FIG 203. (M)Feb 22, 2000 · N512AU · Boeing 7373B7SDR AALA2000369Floorbeam · crackedTUL - FOUND FLOORBEAM CRACKED ALONG UPPER EDGE BELOW AND INBOARD OF ROLLER TRAY. REMOVED THE CRACKED WEB SECTION 2.25 INCH BY 8 INCH LONG IN FLOORBEAM AND MANUFACTURED AND INSTALLED FILLER AND FLOORBEAM DOUBLERS SRM 53-00-1. (M)Feb 22, 2000 · N135AA · Doug DC1010SDR USAA000156Floorbeam · corrodedCLT - FOUND 3 FEET OF CORROSION ON FLOORBEAM, STATION 312, LBL 13 TO RBL 13. INSTALLED FILLER AND DOUBLER PER SRM 53-10-9. (M)Feb 22, 2000 · N277AU · Boeing 7372B7SDR USAA000239Floorbeam · corrodedCLT - FOUND CORROSION ON FLOORBEAM 2 INCHES BY 2 INCHES, AT STATION 377.7 BL 0 TO LBL 65 FLOOR PANEL. REPAIRED FLOORBEAM T-CAP EPR EA 66717. (M)Feb 22, 2000 · N617AU · Boeing 7572B7SDR USAA000248Floorbeam · corrodedCLT - FLOORBEAM HAS A 1 INCH BY 2 INCH AREA OF CORROSION AT BS 344 LBL 29. REMOVED CORROSION PER SRM 51-10-06. (M)Feb 22, 2000 · N277AU · Boeing 7372B7SDR USAA000249Floorbeam · crackedCLT - FLOORBEAM WEB HAS A 1 INCH AREA OF COROSION AT BS 947 PLUS 1 STRINGER 11R. INSTALLED DOUBLER PER TR 53-30-07A. (M)Feb 22, 2000 · N277AU · Boeing 7372B7SDR 0001056740Floorbeam · corrodedDURING M-CHECK, FOUND CORROSION ON AFT CABIN FLOORBEAM, UPPER T-CHORD, PRESSURE BULKHEAD INSTALLATION CAP. REPAIRED PER EA67-171809.Feb 22, 2000 · N640US · Boeing 747251FSDR RRXA001654Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1180, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATEDFeb 21, 2000 · N994CF · Doug DC862SDR RRXA000819Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES, FABRICATED STRAP DOUBLERS Feb 21, 2000 · N994CF · Doug DC862SDR RRXA000813Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES WITH AD RIVET MATERIAL, FABFeb 21, 2000 · N994CF · Doug DC862SDR TWAA0003022Floorbeam · corrodedDURING CHECK-C MAINT, MEMBRANE WAS CORRODED ON LT SIDE LONGERON 18, STA 660 TO 665. REMOVED CORROSION PER SPM 6-80-01. ALODINED AND PRIMED PER SRM 51-40-3. FABRICATED DOUBLER FROM TWA SN 55-0261. INSTALLED DOUBLER WITH AD RIVETS. SEALED WITH RRC 1422 PER Feb 21, 2000 · N9406W · Doug DC983SDR TWAA0003002Floorbeam · corrodedDURING CHECK-C MAINTENANCE, THE TOP OF FLOORBEAM STA 1322, LBL 40 IN, HAD CORROSION AT FLOOR PANEL HOLE. REMOVED CORROSION OF FLOOR BEAM PER SRM 51-10-3. REPAIRED FLOORBEAM PER SRM 53-05, FIG 20A.Feb 19, 2000 · N953U · Doug DC982SDR RRXA001657Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING HOLES, FABRICATED DFeb 18, 2000 · N994CF · Doug DC862SDR RRXA001656Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES, FABRICATED Feb 18, 2000 · N994CF · Doug DC862SDR RRXA0001653Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1200, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FABFeb 18, 2000 · N994CF · Doug DC862SDR RRXA000815Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES WITH AD RIVET MATERIAL, FABFeb 18, 2000 · N994CF · Doug DC862SDR ASAA0080166Floorbeam · corrodedPHX - DURING 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1231 TO 1250, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-14-3, FIG 12. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080165Floorbeam · corrodedPHX - DURNG 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1174 TO 1193, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01, FIG 1 AND FIG 4. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080163Floorbeam · corrodedPHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1041, RBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01, FIG 4. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080162Floorbeam · corrodedPHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 674 TO 693, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080161Floorbeam · corrodedPHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT STATION 636 TO 655, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080160Floorbeam · corrodedPHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 588 AND 617, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01, FIG 4. (M)Feb 18, 2000 · N969AS · Doug DC983SDR ASAA0080159Floorbeam · corrodedPHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 503 AND 579, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30-2. (M)Feb 18, 2000 · N969AS · Doug DC983SDR 20000329SH031Floorbeam · corrodedDURING C-CHECK, CORROSION WAS NOTED ON FLOORBEAM RT STA 1090 - STA 1110. (X)Feb 18, 2000 · N79754 · Boeing 727227SDR 20000329SH030Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM STA 1090 - STA 1110 (58 INCHES FROM RT SIDE). (X)Feb 18, 2000 · N79754 · Boeing 727227SDR 20000329SH029Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM STA 303.9 - STA 344 (36 INCHES FROM LT SIDE). (X)Feb 18, 2000 · N79754 · Boeing 727227SDR 20000329SH028Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM AT STA 1110 - STA 1130 RT. (X)Feb 18, 2000 · N79754 · Boeing 727227SDR 20000329SH026Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM LT STA 300 - STA 320 (19 INCHES FROM LT SIDE). (X)Feb 18, 2000 · N79754 · Boeing 727227SDR 20000329SH025Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOOR WEB AT LBL 14 BETWEEN STA 1148 - STA 1166. (X)Feb 18, 2000 · N32719 · Boeing 727224SDR DHL200080381CFloorbeam · crackedAT C-CHECK, MAIN CARGO UPPER FLANGE OF THE FLOORBEAM SHOWS 8 INCH CRACK BETWEEN LBL 41 AND LBL 48 AT FS 240. STOP DRILLED CRACK, FABRICATED AND INSTALLED REPAIR DOUBLER IAW EO NR 011802. N/R 5193Feb 18, 2000 · N803DH · Doug DC873FSDR 0000586740Floorbeam · corrodedDURING M CHECK, FOUND CORROSION ON UPPER AND LOWER SURFACE OF FLOORBEAM UPPER T-CHORD. REPAIRED PER EA67-173700.Feb 17, 2000 · N640US · Boeing 747251FSDR RRXA001674Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1020, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES, FABRICATED DOUBLERS AFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001670Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATEFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001667Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRICFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001658Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT ST 1100, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL EXISTING HOLES, FABRICATEFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001655Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1160, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRICFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001649Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1280, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FAFeb 17, 2000 · N994CF · Doug DC862SDR RRXA000996Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR BEAM AT STA 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075-T6 ANDFeb 17, 2000 · N994CF · Doug DC862SDR RRXA001513Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT FLOORBEAM UPPER LOWER CARGO BAY FS 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR ANGLE FROM 7075-T6 AND INSTALLED IAFeb 17, 2000 · N994CF · Doug DC862SDR RRXA000812Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILL HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING HOLES USING AD RIVET MATERFeb 17, 2000 · N994CF · Doug DC862SDR AALA2000332Floorbeam · bentTUL - FOUND BOTTOM LIP OF FLOORBEAM IS BENT AT STATION 899 AND STATION 92R. REMOVED BENT PORTION OF LIP AND INSTALLED DOUBLER PER SRM 53-00-01. (M)Feb 17, 2000 · N135AA · Doug DC1010SDR TWAA0003016Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON TOP OF FLOOR WEB, FWD SIDE OF FLOOR SUPPORT ON AFT SIDE, STA 200, BL-0, LBL 52. REMOVED CORROSION BY REMOVING WEB. INSTALLED WEB REPAIR PER SRM 53-01, PAGE 9 SHEET 3, FIG 2.Feb 17, 2000 · N989Z · Doug DC931SDR CALA0000170Floorbeam · corrodedINSPECTION FOUND G-2 GALLEY FLOOR SUPPORT CORRODED AT FS 218, RBL 6. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-30-05 AND 51-10-03.Feb 17, 2000 · N938MC · Doug DC983SDR CALA0000169Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORTS CORRODED AT FS 160-200, BL 0 TO LBL 12 AND AT STA 200, BL 0 TO RBL 44. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-30-01, 51-30-02, 51-10-04, 51-10-3, AND 53-14-01.Feb 17, 2000 · N938MC · Doug DC983SDR AWXA0000087Floorbeam · corrodedFLOORBEAM CORRODED BEYOND LIMITS AT TOP CAP STA 294.5 AT LBL 8. REMOVED DAMAGED UPPER CHORD IAW 737 SRM 53-10-51, FABRICATED SPLICE ANGLE FROM (BAC 14902734 7075T6 R673166), FLOORBEAM FROM (AND10136-2404 7075T6 R745841), INSTALLED SPLICE ANGLES AND FLOORBEAM UFeb 17, 2000 · N312AW · Boeing 7373S3SDR AWXA0000086Floorbeam · corrodedFLOORBEAM UPPER T CAP CORRODED BEYOND LIMITS AT STA 328 RBL 24.5 TO 60. REMOVED T CAP, FABRICATED REPAIR PARTS FROM (PINALCO 7075T6R696065), ANGLE FROM ( BAC 14902734 7075T6 R673166), 4 ANGLES FROM (BAC 14902738 7075 T6 R697241), AND RADIUS BLOCK (.125 7075Feb 17, 2000 · N312AW · Boeing 7373S3SDR RRXA001652Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1220, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FAFeb 16, 2000 · N994CF · Doug DC862SDR 0001271234Floorbeam · crackedDURING H-CHECK, FOUND CRACK ON FLOORBEAM AT BS 1099 LBL 58. REPAIRED PER EA 12-174996.Feb 16, 2000 · N234NW · Doug DC1030SDR UPS00231938Floorbeam · corrodedINSPECTION TYPE:C&SI, FWD CARGO LEFT FLOOR TRACK UPPER SURFACE CORRODED AT BS 482 ALSO CORROSION EVIDENT ADJACENT ANCHOR NUTS LWR SURFACE BS 480 - BS 540. FWD CARGO BAY LEFT FLOOR TRACK REPLACED FROM BS 480 TO 680 IAW SRM 51-30-2, 7 SRM 53-10-5 FIG 8.Feb 16, 2000 · N908UP · Boeing 72727CSDR SWAA000289Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 986 FLOORBEAM UPPER SURFACE CORRODED, RBL 36. REPAIRED BEAM PER SRM.Feb 16, 2000 · N604SW · Boeing 7373H4
Back to JASC 5315