JASC 5315

Service difficulty reports · 44,223

Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5315'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR TWAA0006108Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND HEAVY CORROSION AT STA 200, LBL 24 AND LBL 43. INSTALLED NEW FLOOR SUPPORT WITH RIVETS PER SRM 51-30-2. PATTERN FROM OLD PART. ALODINED, PRIMED, AND PAINTED WHITE. ---CLOSED---Feb 29, 2000 · N989Z · Doug DC931SDR TWAA0006107Floorbeam · corrodedDURING OP 16 MAINT CHECK, CABIN FLOOR SUPPORT AT LBL 46 TO LBL 56 HAD HEAVY CORROSION. REPLACED FLOOR SUPPORT AT STA 200 FROM LBL 46 TO 56 WITH RIVETS PER SRM 51-36-02. PATTERN FROM OLD PART. ALODINED, PRIMED, AND PAINTED WHITE. ---CLOSED---Feb 29, 2000 · N989Z · Doug DC931SDR TWAA0003718Floorbeam · canningDURING OP 16 MAINT CHECK, THE CABIN FLOOR WEB AT STA 160 TO 200 WAS OIL CANNING AND STRETCHED EXCESSIVELY, BL 0 AND LBL 42 INCHES. INSTALLED NEW MEMBRANE FROM STA 175 TO 200, BL 0, TO LBL 44 IN, WITH RIVETS PER SRM 51-30-2.Feb 29, 2000 · N989Z · Doug DC931SDR TWAA0003709Floorbeam · crackedDURING OP 16 MAINT CHECK, THE FWD CABIN FLOOR MEMBRANE WAS CRACKED AT STA 200, RBL 24. STOP DRILLED CRACK AND INSTALLED REPAIR DOUBLER PER SRM 53-01, FIG 4 SHEET 3.Feb 29, 2000 · N984Z · Doug DC931SDR SWAA000373Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED, BS 344, LBL 22 TO RBL 9. REPAIRED BEAM PER TI.Feb 29, 2000 · N314SW · Boeing 7373H4SDR CALA0000220Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT FS 160-200, RBL 44. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-10-04, 53-14-01, AND 51-30-02.Feb 29, 2000 · N938MC · Doug DC983SDR CALA0000219Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT FS 160-200, LBL 22 TO LBL 44. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-30-2.Feb 29, 2000 · N17812 · Doug DC982SDR CALA0000218Floorbeam · corrodedINSPECTION FOUND SUB FLOOR CORRODED UNDER SUPPORT AT FS 200, LBL 4 TO RBL 4. THE FLOOR SUPPORT WAS REMOVED IAW SRM 51-10-4 AND 51-30-5. THE CORRODED AREA WAS REMOVED IAW SRM 53-01, FIGURE 1B. A DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 2, 51-10-3, AND 51-Feb 29, 2000 · N17812 · Doug DC982SDR RAIA0002031Floorbeam · corrodedMX-STL- DURING MAINTENANCE CHECK, FOUND CORROSION AT FRAME 37 FLOORBEAM. MAINTENANCE REPLACED FLOORBEAM AT FRAME 37.Feb 29, 2000 · N721TE · Aerosp ATR72202SDR RAIA0002030Floorbeam · corrodedMX-STL- DURING MAINTENANCE INSPECTION FOUND CORROSION AT FLOORBEAM 38. MAINTENANCE REPLACED FLOORBEAM 38 IAW ATR SRM.Feb 29, 2000 · N721TE · Aerosp ATR72202SDR RAIA0002029Floorbeam · corrodedMX-STL- DURING MAINTENANCE INSPECTION FOUND CORROSION AT FLOORBEAM 39. MAINTENANCE REPLACED FLOORBEAM 39 IAW ATR SRM.Feb 29, 2000 · N721TE · Aerosp ATR72202SDR RAIA0002028Floorbeam · corrodedMX-STL- MAINTENANCE FOUND CORROSION AT FLOORBEAM 40. MAINTENANCE REPAIRED FLOORBEAM 40 IAW ATR SRM.Feb 29, 2000 · N721TE · Aerosp ATR72202SDR QXEA0000671Floorbeam · corrodedPDX- LIGHT CORROSION ON TOP OF FLOOR SUPPORT BEAM BETWEEN FRAMES 3820 AND 4900 BL 0. REPAIRED IAW FOKKER SRM 51-31-01.Feb 29, 2000 · N478US · Fokker F28MK4000SDR TWAA0003902Floorbeam · corrodedDURING CHECK-C MAINT, MEMBRANE BELOW FLOOR STA 1140 TO 1180, LBL 48 TO 56, HAD CORROSION ON UPPER AND LOWER SURFACES. REMOVED CORROSION PER SRM 53-01, PAGE 18 FIG 4 SHEET 3, AND TWA STD PROCEDURES MANUAL 6-80-01 PAGE 1 TO 3. TREATED AND PRIMED PER SRM 51-10-Feb 28, 2000 · N953U · Doug DC982SDR TWAA0003804Floorbeam · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON SUB FLOOR MEMBRANE AT STA 160 TO 200, LBL 6 IN TO RBL 53 INCHES. REPLACED SUB FLOOR MEMBRANE STA 160 TO 200, LBL 12 TO RBL 59, WITH 0.020 7075-T6, INSTALLED WITH SEALER AND 3 ROWS OF ATTACHMENT FASTENERS PER SRM 53-01,Feb 28, 2000 · N9406W · Doug DC983SDR TWAA0003735Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 1155, BETWEEN NUMBER 3 AND 4 GALLEYS TIE DOWN TRACK. REPLACED FLOOR SUPPORT PER SPM 6-70-01. PRIMED AND PAINTED PER SRM 51-10-03.Feb 28, 2000 · N9406W · Doug DC983SDR TWAA0003728Floorbeam · corrodedDURING OP 16 MAINT CHECK, FLOOR WEB HAD CORROSION AT STA 20, LBL 48 INCHES, BELOW FWD END OF CHAIR TRACK. REMOVED CORROSION PER SPM 6-80-1. INSTALLED NEW MEMBRANE AT STA 200 FWD OF NUMBER 1 TRACK WITH PROPER FASTENERS PER SRM 51-30-2.Feb 28, 2000 · N989Z · Doug DC931SDR TWAA0003717Floorbeam · crackedDURING OP 16 MAINT CHECK, THE FLOORBEAM DOUBLER WAS CRACKED AT STA 180, LBL 19 TO BL 0. REPAIRED PER SRM 53-05, PAGE 224, AND DOUGLAS PRINT 99223484.Feb 28, 2000 · N989Z · Doug DC931SDR TWAA0003716Floorbeam · crackedDURING OP 16 MAINT CHECK, THE FLOORBEAM DOUBLER WAS CRACKED AT STA 180, LBL 19 TO 54. REPAIRED PER SRM 53-05, PAGE 224 AND DOUGLAS PRINT 9923484.Feb 28, 2000 · N989Z · Doug DC931SDR USAA000275Floorbeam · crackedCLT - FOUND CRACK IN T-CAP, 2 INCHES, BL 0 AT STATION 663. INSTALLED REPAIR STRAPS AND ANGLES PER TR 57-10-04. (M)Feb 28, 2000 · N260AU · Boeing 737201SDR USAA000282Floorbeam · corrodedCLT - FOUND CORROSION LEVEL 1, 2 INCHES BY 12 INCHES, STATION 244, LBL 44 TO LBL 56 FLOOR LEVEL. INSTALLED REPAIR PER TR 53-10-13. (M)Feb 28, 2000 · N277AU · Boeing 7372B7SDR UPS00831983Floorbeam · crackedINSPECTION TYPE:C123, FLOORBEAM END FITTING IS CRACKED AT STA 1200 RBL54. REMOVED, FABRICATED AND REPLACED FITTING IAW DWG 3754923 AND SRM 51-1-20D.Feb 27, 2000 · N706UP · Doug DC871FSDR CALA0000211Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 160-200, LBL 12. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-30-1.Feb 27, 2000 · N17812 · Doug DC982SDR COMA0060206Floorbeam · corrodedTOP OF FLOORBEAM CAP LBL 27, LBL9, RBL9, RBL27 FS TO FS 409 CORRODED. REMOVED AND REPLACED FLOORBEAM CAPS IAW CANADAIR REO 601R-53-00-027.Feb 26, 2000 · N931CA · Cndair CL6002B19SDR COMA0060205Floorbeam · crackedFS 621.00 FLOOR SUPPORT STRUCTURE CRACKED BETWEEN LBL42 AND LBL9 W.L. 73 LEFT SIDE. REPAIRED FS 621.00 FLOOR SUPPORT STRUCTURE LEFT SIDE I/A/W CANADAIR REO 601R-53-61-117 REV A.Feb 26, 2000 · N991CA · Cndair CL6002B19SDR RRXA001673Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATFeb 25, 2000 · N994CF · Doug DC862SDR RRXA000997Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075-T6 ANDFeb 25, 2000 · N994CF · Doug DC862SDR RRXA001501Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOOR BEAM AT STA 902 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075Feb 25, 2000 · N994CF · Doug DC862SDR CALA0000205Floorbeam · crackedINSPECTION FOUND FLOOR SUPPORT WEB CRACKED STA 1287-1301, RBL 2. AN INTERCOSTAL WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.Feb 25, 2000 · N938MC · Doug DC983SDR RRXA001672Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRIFeb 24, 2000 · N994CF · Doug DC862SDR RRXA001671Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATEDFeb 24, 2000 · N994CF · Doug DC862SDR RRXA000998Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM STA 920 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075Feb 24, 2000 · N994CF · Doug DC862SDR RRXA000951Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE AFT UPPER CARGO COMPT. TOP OF FLOORBEAM AT STA 1530, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRFeb 24, 2000 · N994CF · Doug DC862SDR RRXA001518Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 857 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FRFeb 24, 2000 · N994CF · Doug DC862SDR RRXA001517Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 857 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FRFeb 24, 2000 · N994CF · Doug DC862SDR RRXA000817Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FUSE STRUCTURE AFT UPPER CARGO COMPT OF FLOORBEAM AT STA 1440, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES, FABRICATED STFeb 24, 2000 · N994CF · Doug DC862SDR RRXA000816Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES WITH AD RIVET MATERIAL, FABFeb 24, 2000 · N994CF · Doug DC862SDR TWAA0003708Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR SUPPORT CORRODED AT STA 237 BETWEEN BL O AND LBL 22 IN. FABRICATED NEW PART PER SAMPLE SPM 6-70-01 AND SRM 53-11-1 MATERIAL SPECS. APPLIED PROTECTIVE TREATMENT PER SRM 51-10-3. INSTALLED PART PER SRM 51-30 AND 51-10-04.Feb 24, 2000 · N984Z · Doug DC931SDR COMA0060208Floorbeam · corrodedFLOORBEAM WEBBING AT LBL 9 FROM FS 280 TO FS 295 CORRODED. INSTALLED NEW FLOORBEAM WEBBING IAW WVAC EO 601R-53-0985.Feb 24, 2000 · N931CA · Cndair CL6002B19SDR RRXA001650Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1260, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED Feb 23, 2000 · N994CF · Doug DC862SDR RRXA000562Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FLOORBEAM AT STA 70 AND LONGERON RBL 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED IAW DC-8 SRM 51-1-20D AND SK 831-235. (CORROSION DAMAGE RFeb 23, 2000 · N831AL · Doug DC873FSDR GAIA0094Seat Track · crackedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND CRACK IN SEAT TRACK WEB FORWARD OF STATION 620 LBL 48. REMOVED AND REPLACED SEAT TRACK IAW SRM 53-10-5. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)Feb 23, 2000 · N6808 · Boeing 727223SDR GAIA0095Floorbeam · crackedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND FLOORBEAM WEB AT BS 294.5 LBL 17 IS CRACKED IN THREE PLACES. REPAIRED IAW SRM 51-40-2. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)Feb 23, 2000 · N6808 · Boeing 727223SDR CALA0000193Floorbeam · crackedINSPECTION FOUND FLOOR SUPPORT WEB CRACKED AT STA 1287-1301, BL 0. AN INTERCOSTAL WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.Feb 23, 2000 · N938MC · Doug DC983SDR CALA0000189Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT UPPER LOBE UNDER CABIN FLOOR LAV/GALLEY AT STA 1884 BETWEEN RBL 90 AND LBL 90. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-60-01, 51-21-01, AND 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030SDR CALA0000188Floorbeam · crackedINSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT AT STA 575, RBL 65. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-60-01, 51-21-01, AND 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030SDR CALA0000187Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORTS CORRODED AT UPPER LOBE UNDER LAV/GALLEY, STA 459-495, LBL 22 TO RBL 22 AND STA 457-495, LBL 52. NEW FLOOR SUPPORTS WERE INSTALLED IAW SRM 53-13-01, FIGURE 1, 53-60-01, 51-21-01, AND 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030SDR CALA0000186Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORTS CORRODED AT GALLEY, STA 760-890, LBL 45 AND STA 780-880, RBL 45. NEW FLOOR SUPPORTS WERE INSTALLED IAW SRM 53-13-01, 53-70-00, FIGURE 13, AND 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030SDR CALA0000184Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT UPPER LOBE UNDER CABIN FLOOR LAV/GALLEY AT STA 1902-1921 BETWEEN RBL 21 TO LBL 21. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-60-01, 51-21-01, AND 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030SDR CALA0000183Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORTS CORRODED AT UPPER LOBE UNDER CABIN FLOOR LAV/GALLEY AT STA 1868-1884 BETWEEN LBL 5 AND RBL 5, BL 0 TO RBL 35, AND RBL 35-LBL 35. THE FLOOR SUPPORTS WERE REMOVED AND NEW SUPPORTS WERE INSTALLED IAW SRM 51-31-01.Feb 23, 2000 · N49082 · Doug DC1030
Back to JASC 5315