JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL9771209DFloorbeam · corrodedAT D-CHECK, FLOORBEAM HAS CORROSION AT STA 640 RBL 24-63. CUT OUT DAMAGED AREA, INSTALLED CABIN FLOORBEAM REPAIR. RBL 24 TO 36 PER SRM 53-10-8, REMOVE CORROSION ON UPPER SURFACE FROM RBL 36 TO 63, MATERIAL LOSS WITHIN LIMITS PER SRM 53-10-1.SDR TWAA9809414Floorbeam · corrodedMCI - DURING OP 15 MAINTENANCE CHECK, FOUND CORROSION ON LOWER SIDE OF THE FLOORBEAM AT STA 200, LBL 43 INCHES TO RBL 43 INCHES. REMOVED CORROSION PER SRM 51-10-03, AND REPAIRED PER SRM 53-01, FIG 25 SHT 4, PAGE 9. (X)SDR ABXA9700601Floorbeam · corrodedDURING C-INSPECTION, FOUND LEVEL 2 CORROSION ON FLOORBEAM AT FS 937 LOWER FLANGE RBL 10 TO RBL 18. REPAIRED FLOORBEAM IAW ABX REA D953-18328MR AND DC-9 SRM CHAPTER 53-05, FIGURE 65.SDR ABXA9700600Floorbeam · corrodedDURING C-INSPECTION, FOUND THE LOWER CHANNEL ON FLOORBEAM AT FS 939 CORRODED AT NUT PLATES FROM LONGERON 18 RIGHT TO LONGERON 18 LEFT. REPLACED FLOORBEAM SUPPORT CHANNELS IAW DC-9 SRM CHAPTER 51-30-2.SDR 9703505511Floor Beam · corrodedDURING TRANSITION CHECK, FOUND CORROSION ON FLOOR BEAM LOWER SURFACE OF UPPER CHORD AT FS 1681, RBL 32 AT NUTPLATE. REPAIRED PER EA 55-121564.SDR 9703485511Floor Beam · corrodedDURING TRANSITION CHECK, FOUND CORROSION ON FLOOR BEAM LOWER SURFACE OF UPPER CHORD FS 1681, LBL 52 AT NUTPLATE. REPAIRED PER EA 55-121564.SDR GAIA9714Floorbeam · corrodedDURING C-CHECK INSPECTION, FOUND FLOORBEAM AT STATION 1166 LBL 48 CORRODED BEYOND LIMITS. FLOOR WAS REPAIRED ON KHA EA B53-011. (M)SDR CALA9700275Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 328, 49 INCHES RIGHT OF CENTERLINE. AN L-ANGLE REPAIR WAS INSTALLED IAW SRM 51-70-11.SDR CALA9700274Floorbeam · crackedINSPECTION FOUND A .75 INCH CRACK IN UPPER RADIUS OF FLOORBEAM AT B.S. 520, LEFT INBOARD SEAT TRACK, OUTBOARD SIDE. REPAIRED IAW ECRA 5320-01406.SDR 97ZZZM644Floorbeam · corroded31J - THE FOLLOWING WAS FOUND, AFT CARGO FLOORBEAM STATION 1007 HAS CORROSION RBL 24 TO LBL 40. REMOVED CORRODED AREA, FABRICATED TWO 'L' ANGLES, DIM 31 INCH BY 2 INCH BY 1 INCH AND 27.5 INCH BY 2 INCH BY 1 INCH. FABRICATED T-CAP, 27.6 INCH BY 2 INCH BY 2.8 SDR 97ZZZM586Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT AERO CORP, THE FOLLOWING WAS FOUND; CABIN FLOORBEAM AT STATION 360 LBL 24 - RBL 24 TOP OF FLOORBEAM AROUND FASTENER HOLES HAVE EXFOLIATION AND CORROSION. FABRICATED (2) 'L' ANGLES FROM 7075 T6 26 INCH BY .75 INCH BY 1, .9375 ISDR VJ970054Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, AFT CARGO COMPARTMENT FLOORBEAM CORRODED AT STATION 965 LEFT SIDE AT NUT CLIPS UNDER CABIN FLOOR. (M)SDR ASAA9710013Floor Beam · corrodedSEA - DURING C-CHECK, THE FLOOR BEAM UPPER FORWARD FLANGE AT BS 344 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01509 AND BOEING TELEX ASA-SEA-97-0039RR. (M)SDR ASAA9710012Floor Beam · corrodedSEA - DURING C-CHECK, THE FLOOR BEAM UPPER FORWARD FLANGE AT BS 1006 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01508 AND BOEING TELEX ASA-SEA-97-0038RR. (M)SDR 97FDEA00102Floorbeam · corrodedNR 0785 010, STA 1070 RBL 50, FLOORBEAM HAS CORROSION AROUND NUTCLIP HOLE. REPAIRED FLOORBEAM WITH DOUBLERS, CUTOUT DAMAGED AREA AND REPLACED WITH FILLER PER SRM 53-10-8.SDR SWAA970195Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED AT BS 294.5, AT RBL 4, WL 208, AT BS 986.5, RBL 20 TO 45, RBL 5. REPAIRED PER BOEING SRM.SDR F3LA97048Floor Beam · corrodedPAE - FLOOR BEAM UPPER CHORD AT BS 277 HAS TWO .625 INCH DIAMETER HOLES AT LBL 17 AND LBL 24, WL 208. CORROSION WAS DISCOVERED AT BS 277 LBL 17, LBL 20, AND LBL 25 WL 208. REMOVED CORROSION ON FLOOR BEAM FOUND TO BE OUT OF LIMITS, IAW 53-10-1, REPAIRED FLOORSDR AWXA9700111Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM BS 328, RBL 40 - 60. REPAIRED TOP CHORD OF STA 328 FLOORBEAM, RBL 60 - LBL 40, WL 208 PER 737-200 SRM 53-10-9, FIG. 5.SDR 97FDEA00103Floorbeam · corrodedNR 0782 011, STA 1130 RBL 60 FLOORBEAM HAS CORROSION AND PIECE OF FLOORBEAM GROUND OFF BELOW SEAT TRACK. REMOVED CORROSION, TREATED AND PRIMED AREA, INSTALLED ANGLE REPAIR PER EA 7-5310-28980 DATED 2-4-97.SDR C2XA97IA053Floorbeam · corrodedIAH - DURING ROUTINE INSPECTION, FUSELAGE FRAME NR 41 LOWER FLOORBEAM WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE PERFORMED A REPAIR PER ATR-42 SRM AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR UPS97222267Floorbeam · corrodedINSPECTION TYPE-SI, CORROSION STA 950 FLOORBEAM ON TOP AND BOTTOM OF UPPER CHORD AROUND NUTPLATE HOLES LBL 60 TO RBL 60. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-1. REPAIRED PER SRM 53-10-6, 51-20-151, 53 10-5, 51-30-2 AND EWO 97-2056 UPS ENG FILE NSDR UPS97422007Floorbeam · corrodedINSPECTION TYPE: C. FLOORBEAM UPPER CHORD BS. 1800 IS CORRODED AT RBL. 94. FLOORBEAM UPPER CHORD AT BS. 1800 RBL. 94 OUT OF LIMITS I.A.W. SRM. 53-10-01 FIG.1. REPAIRED FLOORBEAM UPPER CHORD AT BS. 1800 RBL. 94. I.A.W. SRM.53-10-07.SDR F3LA97046Floor Beam · corrodedPAE - FOUND CORROSION (C53-107-02) ON FLOOR BEAM UPPER CHORD, BS 360, RBL 1 TO LBL 11, WL 208.1. FOUND CORROSION BEYOND LIMITS. REMOVED BS 360, WL 208.1 CHORD FROM LBL 13 TO RBL 15. FABRICATED AND INSTALLED REPAIR. ALL WORK DONE IAW SRM 53-10-1, 53-10-9, 5SDR F3LA97037Floor Beam · corrodedPAE - FOUND CORROSION (C53-107-02) ON FLOOR BEAM UPPER CHORD BS 344, RBL 9 TO LBL 65. FOUND CORROSION BEYOND LIMITS PER SRM 52-10-1. REMOVED CHORD FROM LBL 65 TO RBL 65. FABRICATED AND INSTALLED NEW CHORD. ALL WORK PERFORMED IAW SRM 51-10-6, 53-10-2, 53-10SDR 97FDEA00113Floorbeam · corrodedNR 0379 001, UPPER LOBE STA 344 FLOORBEAM CORRODED AT CLIP NUTS HOLES, LBL 35 TO LBL 40. REMOVED CORRODED SECTION OF FLOORBEAM AND INSTALLED REPAIR PER DRAWING SR 27-53-007.SDR UPS97822061Floorbeam · crackedINSPECTION TYPE-C, FLOORBEAM CRACKED AT FASTENER HOLE FS 1580 LBL 36. CUT OUT DAMAGED AREA AND REPAIRED IAW DHC SK-806-586 REV C REF ENRG FILE NR DC8-53-1741.SDR F3LA97036Floor Beam · corrodedPAE - FOUND CORROSION (C53-107-02) ON FLOOR BEAM UPPER CHORD BS 328, RBL 60 - LBL 30, WL 208.1. REMOVED CORROSION ON FLOOR BEAM UPPER CHORD BS 328. FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. FABRICATED UPPER CHORD AND REPAIR ANGLES FROM 7075-T6 .090 T-ANGLESDR 97ZZZM618Floorbeam · corrodedFORWARD CARGO STATION 328 CABIN FLOORBEAM HAS CORROSION RBL 24-56. FABRICATED 'L' ANGLES, TWO 1 INCH BY 2 INCH BY 100 INCH, ONE 1INCH BY 2 INCH BY 30 INCH FROM BAC 1505 100246 T-ANGLE, TWO 1 FOOT 1.5 INCHES BY .063 INCH AND TWO 1 INCH BY 1 INCH BY 8 INCH BY .SDR 9703022287Floorbeam · corrodedDURING M-CHECK, FOUND CORROSION IN FLOORBEAM AT FS 1130 FROM LBL 12 TO LBL 18. REPAIRED PER EA 22-77369.SDR F3LA97033Floor Beam · corrodedPAE - FOUND CORROSION (C53-107-02) ON FLOOR BEAM UPPER CHORD BS 294, LBL 21 TO RBL 60, WL 208.1. REMOVED CORROSION ON FLOOR BEAM UPPER CHORD BS 294, LBL 21 TO RBL 60, WL 208.1 IAW SRM 51-10-6. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1. REMOVED UPPER CHORD FSDR DL72S970258Floorbeam · corrosionCORROSION ON TOP SIDE OF FLOORBEAM STA 344 FROM BL 0 TO LBL 39. REMOVED DAMAGED SECTION OF BEAM, FABRICATED AND INSTALLED A REPLACEMENT CHORD SECTION PER SRM 53-10-8, FIG 11.SDR 97ZZZM617Floorbeam · corrodedCORROSION ON FLOORBEAM BS 294 BL 24 LEFT. FABRICATED 4 'L' ANGLES FROM 7075 .063 12 INCH BY 1.25 INCH BY 1 INCH AND 2.10 INCH BY 1.25 INCH BY 1. INSTALLED IAW SRM 53-10-9 FIG 5.SDR 97ZZZM615Floorbeam · corrodedFLOORBEAM T-CAP CORRODED AT FS 294.5 FROM LBL 12 TO RBL 12. CORROSION WAS .030 BEYOND LIMITS IAW SRM 53-10-1. FABRICATED FLOORBEAM SECTION OUT OF 7075 T611 98.5 INCH BY 2 INCH BY 1 INCH. INSTALLED REPAIR IAW SRM 51-30-2, 51-10-1, 51-10-2 AND MM 51-21-21.SDR 97ZZZM606Floorbeam · corrodedFLOORBEAM FS 344 (UPPER T-CAP) CORRODED FROM LBL 45-58. CORROSION WAS .030 BEYOND LIMITS IAW SRM 53-10-1 FIG 1. FABRICATED ONE FLOORBEAM REPAIR. FABRICATED 6 ATTACH ANGLES. ONE OUT OF 7075 T6 11 11.75 INCH BY 1 INCH BY 1 INCH BY .063. THREE OUT OF 7075 T61SDR 9703046624Floorbeam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON FLOORBEAM AT FS 450 TO 456, RBL 22 TO RBL 32. REPAIRED PER EA 66-121373.SDR USAA970048Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION MEASURING 56 INCHES LOCATED AT FLOOR BEAM STATION 312. CORROSION TASK NR C53-107-03, CORROSION LEVEL 2. INSTALLED REPAIR ANGLES AS PER TYPICAL REPAIR 53-10-03. (M)SDR SWAA970175Floorbeam · crackedDURING SCHEDULED 1/2 D CHECK, FOUND FLOOR BEAM CRACKED ON UPPER FLANGE OF WEB .5 INCH AFT OF BS 1006, LBL 2.5. REPAIRED PER BOEING SRM.SDR CALA9700145Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED BETWEEN SEAT TRACKS 2-13 AT STA 360. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-9.SDR CALA9700144Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 744, RBL 15 TO LBL 15. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A FLOORBEAM REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-9 AND 51-30-2.SDR CALA9700143Floorbeam · corrodedINSPECTION FOUND UPPER FLANGE OF FLOORBEAM CORRODED AT STA 980. THE UPPER FLANGE WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-9 AND 51-30-2.SDR CALA9700141Floorbeam · corrodedINSPECTION FOUND UPPER FLANGE OF FLOORBEAM CORRODED AT STA 328, RBL 24 TO RBL 50. THE UPPER CHORD OF BEAM WAS REMOVED. REPAIRS WERE FABRICATED AND INSTALLED IAW SRM 53-10-9 AND 51-30-2.SDR CALA9700136Floorbeam · crackedINSPECTION FOUND A 2 INCH CRACK ON UPPER FLANGE OF FLOORBEAM AT BS 667, BL 0. A REPAIR WAS FABRICATED AND INSTALLED IAW ECRA 5710-01779.SDR CALA9700135Floorbeam · crackedINSPECTION FOUND A 1 INCH CRACK IN LOWER RADIUS OF FLOORBEAM AT STA 685, BL 0. A 1 INCH CRACK WAS FOUND IN TRANSVERSE BEAM AT STA 675, BL 0. THE FLOORBEAM WAS REPAIRED IAW BAC DRAWING 65C19643. THE TRANSVERSE BEAM WAS REPAIRED IAW BAC DRAWING 65C17103.SDR 97ZZZM641Floorbeam · corroded31J - THE FOLLOWING WAS FOUND, CABIN FLOORBEAM STATION 328 BL '0' 60 HAS CORROSION. FABRICATED NEW FLOORBEAM FROM BAC 1505-100246 15.5 BY 2 INCH IAW SRM 51-101. FABRICATED T-CAP FROM 7075 T6511 2.25 INCH BY 3 INCH BY 60 INCH AND 1.25 INCH BY 2.25 INCH BY 60 SDR 97ZZZM634Floorbeam · corroded31J - THE FOLLOWING WAS FOUND, CABIN FLOORBEAM HAS CORROSION STATION 295 RBL 60 TO UNDER FORWARD LAVATORY. FABRICATED T-CAP SECTION FRM AND 10136-2401 79.5 INCH BY 2.5 INCH BY 1.25 INCH. FABRICATED FOUR ANGLES 7075 T6 .063 1 INCH BY 1 INCH 14 INCH TWO AND 1 SDR 97ZZZM632Floorbeam · corroded31J - THE FOLLOWING WAS FOUND, CABIN FLOORBEAM HAS CORROSION STATION 344 RBL 16 - LBL 60. FABRICATED T-CAP FROM 60-893 83 INCH BY 1 INCH BY 1.25 INCH. FABRICATED FOUR ANGLES FROM BAC 1490-2865 TWO 11 INCH BY 1.5 INCH BY 1 INCH AND TWO 7.25 INCH BY 1 INCH BY SDR 97ZZZM631Floorbeam · corroded31J - THE FOLLOWING WAS FOUND, CABIN FLOORBEAM AND PAN HAS CORROSION. FABRICATED FILLER AND SHIM FROM 7075 T6 .071 8.5 INCH BY 1 INCH (SHIM) 7075 T6 .125 3.5 INCH BY 1 INCH IAW EO 97-470. INSTALLED REPAIRS IAW EO 97-470, N/R NR 71123/0734.SDR UPS97422026Floorbeam · corrodedINSPECTION TYPE-C, MAIN DECK FLOOR STRUCTURE: FLOORBEAM UPPER CHORD BS 1580 IS CORRODED ON LOWER SIDE OF FLANGE AT LBL 70. CORROSION FOUND TO BE BEYOND LIMITS OF SRM 53-10-01. FLOORBEAM UPPER CHORD BS 1580 LBL 0 TO OUTBOARD REPLACED ACC TO SRM 51-30-02.SDR SWAA970172Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORROSION AT BS 294, WL 208. REPLACED DAMAGED SECTION PER BOEING SRM.SDR SWAA970165Floorbeam · crackedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM SUPPORT STRAP CRACKED AT BS 312-328, RBL 30. REPAIRED PER BOEING SRM.
Back to JASC 5315