JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 95FDEA00853Floor Beam · corrodedFS 360 RBL 19-20. CORROSION ON FLOORBEAM AROUND FLOORBOARD ATTACH SCREW HOLE. REPAIRED PER AA ESO 11782 FEDEX EA NR 7-5310-25029.SDR 95FDEA00851Floor Beam · corrodedCORROSION ON TOP OF FLOORBEAM AROUND FLOORBOARD ATTACH SCREW HOLE, BS 360 RBL 20-22. BLENDED OUT CORROSION ON TOP LEG OF FLOORBEAM. BLEND OUT AREA IS 2.0 INCHES X 1.0 INCH X .075 INCH DEEP, PER SRM 51-10-6 GUIDELINES. INSTALLED REPAIR STRAP PER ESO 11782 DASDR USAA950737Floorbeam · corrodedINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORRODED SCREW HOLE FLOORBEAM BS 986.5, 43 INCHES LBL. INSTALLED UPPER T-CAP REPAIR, ENTIRE LENGTH TR 53-10-05. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR DLL10952453Floorbeam · corrodedFLOORBEAM CORRODED FS 943 LBL 50 TOP OF BEAM, FOUND AT HMV. REPAIRED PER SRM 53-21-00 FIG 823.SDR AWXA9500347Floorbeam · corrodedPHX - DURING C4 INSPECTION, FOUND CORROSION ON LEFT AFT LAVATORY THRESHOLD SUPPORT 'I' BEAM AT STATION 1006 AND STATION 1016. REMOVED AND REPLACED DAMAGED AREA PER SRM 51-40-02. (M)SDR AWXA9500346Floorbeam · corrodedPHX - DURING C4 INSPECTION, FOUND STATION 1016 'I' BEAM CORRODED UNDER LAVATORY. REMOVED AND REPLACED DAMAGED AREA PER SRM 51-70-12. (M)SDR AWXA9500345Floorbeam · corrodedPHX - DURING C4 INSPECTION, FOUND CORROSION ON LEFT AFT LAVATORY THRESHOLD 'I' BEAM BETWEEN STATION 986.5 AND STATION 1006. REMOVED AND REPLACED FILLER IAW SRM 51-40-21 AND SRM 51-10-02, PARAGRAPH 8 AND 9. (M)SDR AWXA9500341Floorbeam · corrodedPHX - DURING C4 INSPECTION, FOUND CORROSION ON TOP CHORD OF FLOORBEAM, STATION 986.5 RBL 22 TO LBL 22. REMOVED AND REPLACED DAMAGED AREA PER MM 51-21-99 AND SRM 53-00-51. (M)SDR AALA951039Floor Beam · corrodedAFW - FLOOR BEAM CORRODED BEYOND LIMITS SRM AFTER BLEND-OUT. INSTALL ANGLE 0.10 INCH THICK 7075-T6 EXTRUSION WET WITH BMS 5-95 FAY SURFACE SEALANT PER B767 SRM AND ENGINEERING MRB 767-943. (M)SDR AALA951037Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLEND OUT. REFINISH BEAM PER B767-SRM. BEAM IS SATISFACTORY FOR CONTINUED SERVICE PER ENGINEERING MRB 767-942. (M)SDR USAA950720Floorbeam · corrodedINT - DURING Q-1 CHECK VISUAL INSPECTION FOUND APPROX 1 INCH BY 7 INCH AREA CORRODED STA 312 ON FLOORBEAM BL 0 RBL 7. REPAIRED PER TR 53-10-03, CUT OUT CORRODED SECTION OF UPPER T-CAP AND SPLICED IN NEW SECTION. THERE WAS LESS THAN ONE POUND ADDED FOR REPAIRSDR USAA950711Floorbeam · corrodedINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 4 INCH, 75 PERCENT LOSS STA 947 TO STA 967 RBL 52 INCHES ON FLOORBEAM. REPAIRED PER SRM 51-10-2, INSTALLED NEW BEAM. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR ABXA9500783Floorbeam · chafedDURING D-CHECK ACCEPTANCE INSPECTION, FOUND A FLOORBEAM CHAFED AT FS 200 IN THE MAIN CABIN. REPAIRED FLOORBEAM AT FS 200 IAW ABX REA D953-11699-MR.SDR ABXA9500613Floor Beam · damagedDURING C-CHECK INSPECTION, FOUND AN EXISTING REPAIR TO THE FLOOR BEAM AT STA. 917 TO BE DAMAGED. REPAIRED IAW ABX REA D953-11698-MR.SDR ABXA9500612Floor Beam · damagedDURING C-CHECK INSPECTION, FOUND TWO HOLES INCORRECTLY LOCATED AND ONE HOLE DOUBLE DRILLED AT STA. 897. REPAIRED IAW ABX REA D953-11716-MR.SDR USAA950715Floorbeam · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 2 INCH BY 2 INCH STA 950 LBL 52 INCHES. REPAIRED PER SRM 51-10-02, REMOVED CORRODED INTERCOSTAL AND INSTALLED NEW ONE. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR USAA950714Floorbeam · corrodedINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 2 INCH BS 967 TO BS 986 RBL 17. REPAIRED PER SRM 51-10-1, REPLACED BEAM. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR USAA950713Floorbeam · corrodedINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH STA 967 TO STA 986 LBL 17 INCHES. REPAIRED PER SRM 51-10-02, REMOVED CORRODED INTERCOSTAL AND INSTALLED NEW PART. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR USAA950708Floorbeam · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 2 INCH STA 947 TO STA 967 RBL 17 INCHES. REPAIRED PER SRM 51-10-1, REPLACED NEW BEAM. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)SDR DL73S952588Floorbeam · crackedDURING LAY OVER, INSPECTION FOUND THE FLOORBEAM AT BL 0.07 OF THE WING CENTER SECTION CRACKED AT STA 661. IN ACCORDANCE WITH BAC S/B 737-57-1210, THE CRACKS ARE TYPICAL AND WILL BE REPAIRED BY THE S/B 737-57-1210.SDR UPS203411Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON BOTTOM OF AFT UPPER FLANGE OF FLOORBEAM STA 480, LBL 60. INSTALLED REPAIR ANGLE IAW B727-5310-7006A.SDR UPS203405Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM UPPER SURFACE OF TOP CHORD STA 344, BL 0, RBL 45. INSTALLED FABRICATED PARTS IAW SRM 51-30-2, 51-20-151, 51-10-2.SDR USAA950571Floorbeam · corrodedINT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH BY 15 INCH TOTAL CORROSION, CORROSION AT SCREW HOLES ON FLOORBEAM AT BS 312 LBL 12 INCHES THROUGH RBL 24 INCHES. REPAIRED PER TR 53-10-03. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR SWAA950445Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 312, RBL 8. REPAIRED PER SWA RA 1-553-1274.SDR SWAA950444Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 312, RBL 8 TO LBL 10. REPAIRED PER SWA RA 1-553-1275.SDR SWAA950443Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 986.5, LBL 25.75 TO 43. REPAIRED PER SWA RA 1-553-1284.SDR SWAA950442Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, RBL 15. REPAIRED PER SWA RA 1-553-1280.SDR SWAA950441Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, RBL 48 TO RBL 53. REPAIRED PER SWA RA 1-553-1283.SDR SWAA950440Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, LBL 21.0. REPAIRED PER SWA RA 1-553-1278.SDR SWAA950439Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, RBL 5.0. REPAIRED PER SWA RA 1-553-1279.SDR SWAA950438Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, LBL 5.0. REPAIRED PER SWA RA 1-553-1282.SDR SWAA950437Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947, LBL 4 TO RBL 2. REPAIRED PER SWA RA 1-553-1277.SDR SWAA950433Floorbeam · corrodedDURING SCHEDULED TRANSITION CHECK, FOUND FLOORBEAM CORRODED AT BS 328 LBL 49 WL 208, BS 294 LBL 10 TO RBL 10 WL 208, BS 986.5 WL 208 RBL 57 TO LBL 57, BS 312 LBL 10 RBL 10 WL 208, AND AT BS 344 RBL 10 TO LBL 40 WL 208. REPLACED PER BOEING STRUCTURAL REPAIR MASDR 9509105528Floor Beam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON THE FS 365 FLOOR BEAM UPPER CHORD FASTENER HOLES RBL 0 - 19. REPAIRED BEAM PER EA 55-98483.SDR UPS203372Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON TOP AND BOTTOM OF FLANGE BL0, LBL 30, WL 208 OF FLOORBEAM BS 560. INSTALLED FABRICATED PARTS IAW 51-10-1, 51-10-2, 51-30-2, 53-10-8.SDR UPS203367Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM AT STA 640 LBL 45 TO 59. REPAIRED IAW UPS EO NR B727-5310-7014A.SDR UPS203366Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON BOTTOM FLOORBEAM AT STA 1090, LBL 48 TO 57, WL 208. SPLICED IN REPAIR SECTION IAW SRM 51-30-2, 51-10-2, 51-10-6, 53-10-8, M/M 51-20-151.SDR UPS203365Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FASTENERS OF FLOORBEAM BS 312, RBL 50, WL 208. INSTALLED FABRICATED REPAIR PARTS IAW SRM 51-10-2, M/M 51-20-151, 51-40-3, EWO 95-2552.SDR UPS203362Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM AT BS 560, RBL 6, WL 199. REMOVED AND INSTALLED REPAIR SECTION IAW UPS EO NR B727-5310-7026A.SDR UPS203357Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON CREASE BEAM AT FASTENER HOLES, BS 304 TO 344, RBL 58, WL 208 UPPER AND LOWER. INSTALLED FABRICATED PARTS IAW SRM 51-40-3.SDR UPS203329Floorbeam · corrodedWHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON BOTTOM FLOORBEAM AT STA 825, RBL 62, WL 208. INSTALLED FABRICATED SUPPORT ANGLE IAW SRM 53-10-1, 53-10-2, 51-30-2, 51-20-4 AND M/M 51-20-151.SDR DLL10952778Floorbeam · corrodedAT HMV, FLOORBEAM CORRODED FS 1463 RT SIDE BELOW CARGO TIE DOWN ABOVE STR 27. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-23-00 FIG 801. REMOVED CORRODED BEAM AND INSTALLED REPLACEMENT BEAM PER LAC DWG NR 1505121.SDR DLL10952771Floorbeam · corrodedAT HMV, FLOORBEAM CORRODED FS 1501 ABOVE STR 39 BELOW CARGO TIE DOWN SUPPORT. REPAIRED PER SRM 53-23-00 FIG 802.SDR DLL10952613Floorbeam · corrodedTOP OF FLOORBEAM IS CORRODED IN SEVERAL PLACES, FS 901 FROM LBL 60 TO RBL 60. REMOVED OLD FLOORBEAM, CUT NEW BEAM, DRILLED HOLES, TREATED AND PAINTED PER SRM 53-21-00 PG 849.SDR DLL10952432Floorbeam · crackedAT HMV, FLOOR FRAME CRACKED AT FS 349 LBL 105 BELOW CABIN FLOOR AT WL 180. REPAIRED PER SRM 53-21-00 FIG 817.SDR DLL10952375Floor Beam · corrosionAT HMV, TOP OF FLOOR BEAM IS CORRODED AT FS 861 LBL 50. CORR: TRIMMED CORRODED FLANGE AS PER SRM 53-21-00 FIG 823. INSTALLED REPAIR ANGLES PER SRM 53-21-00 FIG 823.SDR AWXA9500331Floorbeam · corrodedPHX - DURING SCHEDULED C14 INSPECTION, FOUND TOP OF FLOORBEAM CORRODED AT STATION 312, APPROXIMATELY 12 INCHES LEFT OF BL 0. REPAIRED FLOORBEAM IAW SRM 53-10-9, FIGURE 5. (W)SDR USAA950685Floorbeam · corrodedPIT - DURING Q-5 CHECK INSPECTION, FOUND LEVEL 2 CORROSION IN FLOORBEAM WEB AT STA 1338 RT O/B. CORROSION TASK C58-53305. CUT OUT CORRODED AREA AND INSTALLED WEB REPAIR PER SRM 53-05 FIG 79 SHT 1. (W)SDR USAA950684Floorbeam · corrodedPIT - DURING Q-5 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AROUND 2 HOLES IN FLOORBEAM RT LAV. CORROSION TASK NR C58-53300. REMOVED CORROSION AND INSTALLED FILLER, STRAP AND ANGLE REPAIR PER USAIR TYPICAL REPAIR 53-10-19. (W)SDR USAA950682Floorbeam · corrodedPIT - DURING Q-5 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AT FLOORBEAM TOP FLANGE RT LAV STA 1338 CORROSION TASK NR C58-53300. REMOVED AND REPLACED TOP FLOOR ANGLE AND INSTALLED BEAM SPLICE PER USAIR TYPICAL REPAIR 53-10-14. (W)
Back to JASC 5315