JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022040834854Angle · corrodedFORWARD CARGO COMPARTMENT R/H SIDE SHIELD (Z-ANGLE) HAS CORROSION STA 492 TO 500A RBL 23 / FWD CARGO COMPARTMENT RH SIDE SHIELD (Z ANGLE) HAS CORROSION STA 492 TO 500A RBL23 BLENDED CORROSION AND FOUND A LOSS OF .011' ORIG .032' REMAINING .021 FOUND TO BE OUT SDR SWAA2022040828749Floorboard · delaminatedFWD PASSENGER CABIN FLOORBOARD 222BF HAS SURFACE DAMAGE / FWD PASSENGER CABIN FLOORBOARD 222BF SURFACE DAMAGE REPAIRED IAW SRM 53-00-50-2R-1. DAMAGE DETERMINED TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F. DELAMINATIONS ARE NOT PERMITTED.SDR SWAA2022040666455Intercostal · corrodedCUSTOMER REQUEST: (F.B.) AFT CARGO COMPARTMENT INTERCOSTAL BS 787-807 AT S-27R IS CORRODED. WL 156 / INTERCOSTAL WAS FOUND TO HAVE 100% MATERIAL LOSS. REMOVED AND REPLACED NTERCOSTAL AT STA 787-807 STR 27R IAW BOEING DWG #146A8130 REV: B AND SRM 51-40-02-0G-0.SDR SWAA2022040553559Gusset · crackedFWD CARGO BAY BS 500D STR 21 L/H GUSSET IS CRACKED / REMOVED & REPLACED GUSSET AT FCB BS 500D STR 21 L/H IAW SRM 51-40-02 & DWG 143A7902 REV.-E 59191U 14NOV19SDR SWAA2022040553558Gusset · crackedFWD CARGO BAY BS 500D STR 21 R/H GUSSET IS CRACKED / REMOVED & REPLACED GUSSET AT FCB BS 500D STR 21 R/H IAW SRM 51-40-02 & DWG 113A7902 REV.- E 59191U 14NOV19SDR SWAA2022040142327Scuff Plate · crackedAFT CARGO FWD SCUFF PLATE CORNER CRACK / WELD REPAIR ACCOMPLISHED ON SOUTHWEST EA # 1-A53-2076 REV 11; SEE ATTACHED COPY.SDR SWIA2019123147525Strap · corroded*FS559.00 RBL27 - RBL43 STRAP HAS CORROSION. (C-CHECK) RO 12/27/2019 REMOVED CORRODED STRAP AND INSTALLED NEW FS559.00 RBL27 - RBL43 STRAP (601R31025-29). REF CRJ200 SRM & BOMBARDIER DWG. SEE CONTINUATION CARD FOR DETAILS. PRESSURE CHECK GOOD.SDR SWIA2019123147524Strap · corroded*FS559.00 LBL27 - LBL43 STRAP HAS CORROSION. (C-CHECK) RO 12/27/2019 REMOVED CORRODED STRAP AND INSTALLED NEW FS559.00 LBL27 - LBL43 STRAP (601R31025-29). REF CRJ200 SRM, CRJ200 SRM & BOMBARDIER DWG 601R31025, REV N. SEE CONTINUATION CARD FOR DETAILS. PRESSURSDR SWIA2019123147518Door Sill · corrodedSERVICE DOOR LOWER SILL IN BETWEEN FS 319 AND FS 349.0 HAS CORROSION. (C-CHECK) RO 12/27/2019 REMOVED AND REPLACED SERVICE DOOR LOWER SILL ANGLE IN BETWEEN FS319 AND FS349.0 PER BOMBARDIER DWG, REF CRJ 200 SRM. CLEARANCE CHECK GOOD AT THIS TIME.SDR SWIA2019123147492Casting · cracked* FS 460 RBL 9.0 CASTING BELOW FLOORBOARD HAS CRACK AT UPPER RADIUS. (C-CHECK) RO 12/27/2019 REMOVED CRACKED AND INSTALLED NEW CASTING/ FITTING AT FS460 RBL9.0 BELOW FLOORBOARD REF. BOMBARDIER DRAWING 601R31118 REV. L AND CRJ200 SRM. SEE CONTINUATION CARD FORSDR FDEA2019120413166Support Angle · corrodedAPU INLET PANEL SUPPORT ANGLE HAS EVIDENCE OF CORROSION AT ANCHOR NUT ATTACH POINT LOCATED AT BS 1790 S6R CORROSION REMOVED IAW SRM 51-10-02 AND FOUND TO BE OUTSIDE LIMITS IAW SRM 53-00-04- 1A ORIGINAL MATERIAL THICKNESS = 0.063" REMOVED MATERIAL = 0.030". SDR FDEA2019120433165Angle · corrodedUPON REMOVAL OF APU INLET, CORROSION FOUND ON UPPER AND LOWER ANGLES REMOVED CORROSION IAW SRM 51-10-02 AND FOUND TO BE OUTSIDE LIMITS IAW 53-00-04-1A ORIGINAL MATERIAL THICKNESS = 0.063" REMOVED MATERIAL = 0.032" UPPER AND LOWER ANGLES REPLACED IAW SRSDR FDEA2019120133156Strap · corrodedUPON REMOVAL OF APU INLET CORROSION FOUND ON STRAP AT BSTA 1825. CORROSION REMOVED IAW SRM 51-10-02 AND ONE AREA FOUND TO BE OUTSIDE LIMITS IAW SRM 53-80-15-1A AT MIDDLE STRAP AREA. CARRIED OUT SINGLE STRAP REPAIR IAW SRM 53-80-15-2R REPAIR 2.SDR SWAA2019120439329Stiffener · crackedKEEL BEAM AREA LOWER FUSELAGE HAD AN ANGLE THAT ATTACHES VAPOR BARRIER COMPOSITE WALL AT BS. 663 AND GSE EXHAUST CRACKED AT THE BOTTOM. / R&R STIFFENER PER SRM AND DWG.SDR SWAA2019120239245Web · corrodedFORWARD CARGO DOOR CUTOUT LOWER WEB AREA HAD SEVERAL SPOTS CORRODED AND SCRATCHED. / R&R WEB PER SRM AND DWG.SDR SWAA2019112739189Shear Web · corrodedWEB CORRODED BETWEEN BS. 1016 TO BS. 1026, BETWEEN LBL 0 TO LBL 37. / R&R SHEAR WEB IAW SRM & DWG.SDR YENA201911183649Web · crackedDURING HEAVY MAINTENANCE, CRACK BELLY FAIRING WEB AT LEVEL FR 52 LH SIDE MLG COMPARTMENT ON LOWER FUSELAGE; REF AEROMAN NR WO 2019-238/1 WCC 2019-332147 ACCOMPLISHED CRACK REPAIR OF CENTER FUSELAGE II WING TO FUSELAGE FAIRING FR 52 WEB IN ACCORDANCE WITH AEROMSDR SWAA2022040552608Gusset · out of toleranceFWD CARGO BAY OBLONG HOLE IN GUSSET BS500D; STR21R; WL178. / FCB OBLONG HOLE IN GUSSET BS500D; STR21R; WL178 WAS REMOVED PER SRM 51-40-02-0G-0; FABRICATED STRAP 143A9483-12 FROM 0.063' 7075-T6 LOT# 1387168-1 PER DWG 143A9483; INSTALLED NEW GUSSET AND STRAP BS5SDR C77A2020012700020Bracket · corrodedCORROSION UNDER WET AREA FLOOR ON BRACKET FWD OF AFT HOT WATER DRAIN AFT OF FR 86 STGR 28R-27R AS MARKED. X= 929.34 Y= 8.75 Z= -27;REMOVED CORROSION UNDER WET AREA FLOOR ON BRACKET FWD OF AFT HOT WATER DRAIN AFT OF FR 86 STGR 28R-27R REF SRM 51-12-01. AREA OF SDR SWIA2019123147516Floor Support · corroded* R/H PRESSURE FLOOR SILL STRUCTURE CORROSION NOTED IN AREAS FROM FS409.0 +128 TO FS559.0. (C-CHECK) RO 12/27/2019 PERFORMED BLEND OUT REPAIRS TO RH PRESSURE FLOOR SILL STRUCTURE CORROSION NOTED IN AREAS FROM FS409.0 +128 TO FS559.0. REF BOMBARDIER REO. SEE SDR SWIA2019122747470Plate · corrodedCORROSION ON UPPER PLATE JUST INBOARD OF THE LT FLOOR SUPPORT AT APPROXIMATELY BS 308, LBL 41. REMOVED CORROSION ON THE AFFECTED AREA IAW SRM.SDR SWIA2019122747468Floor Support · corrodedLEFT FLOOR SUPPORT HAD CORROSION BETWEEN FS 295 AND FS 310. REMOVED CORROSION ON THE AFFECTED AREA IAW SRM.SDR SWIA2019122747467Support · corrodedBS 574 - 605, RT FLOOR EDGE MEMBER HAS CORROSION AROUND SEVERAL SCREW HOLES. REMOVED CORROSION IAW SRM. ALL REWORKED AREAS ACCEPTABLE IAW REO. .SDR SWIA2019122747465Door Sill · corrodedCARGO DOOR SILL WAS CORRODED AROUND SEVERAL SCREW HOLES. REMOVED CORROSION FROM THE CARGO DOOR SILL IAW SRM 51-21-06. ALL REWORKED AREAS ARE ACCEPTABLE IAW REO.SDR SWIA2019122747464Floor Support · corrodedRIGHT FLOOR SUPORT BETWEEN BS 349 AND 409+5 WAS CORRODED. REMOVED CORROSION ON THE AFFECTED AREA IAW SRM.SDR SWIA2019122747462Floor Support · corroded*FLOOR BEAM AT 559.0 LBL 9 HAS CORROSION (C-CHECK) RO 12/24/2019 REMOVED CORROSION ON LBL 9 FLOOR BEAM CAP FROM FS409+118 TO FS559+10, OUT OF LIMITS. REPAIRED.SDR SWIA2019122747460Angle · crackedAFT CARGO DOOR SURROUND AT FWD CAM TRACK SUPPORT LOWER ANGLE CRACKED. REPLACED FWD CAM TRACK SUPPORT LOWER ANGLE IAW SRM AND DWG. MAJOR REPAIR.SDR SWIA2019122747459Floor Support · corrodedFLOOR SUPPORT AT BS 559, RBL 9 WAS CORRODED. REMOVED CORROSION FROM BS409+118 TO 559+10. FOUND OUT OF LIMITS, REPAIRED.SDR SWIA2019122747458Floor Support · corrodedFLOOR SUPPORT BETWEEN BS 559+64 - 559+80, RBL 9, WAS CORRODED. EXFOLIATED BEYOND REPAIR. 100% MATERIAL LOSS. OUT OF LIMITS. FABRICATED AND INSTALLED A NEW REPLACEMENT FLOOR SUPPORT. INSTALLED IAW DWG.SDR SWIA2019122747457Floor Support · corrodedRIGHT FLOOR SUPPORT BETWEEN BS 409+32 AND 409+48 WAS CORRODED. REMOVED CORROSION ON THE AFFECTED AREA IAW SRM.SDR SWIA2019122747453Floor Support · corrodedRBL 9 FLOOR SUPPORT CAP, INBOARD FLANGE WAS CORRODED AT MULTIPLE LOCATIONS BETWEEN BS 409+6 AND 409+118. REMOVED AND INSTALLED A NEW FLOOR SUPPORT CAP IAW DRAWING.SDR SWIA2019122747450Floor Support · corrodedLBL 9 FLOOR SUPPORT CAP INBOARD FLANGE HAD CORROSION AT MULTIPLE LOCATIONS BETWEEN BS 409+6 AND 409+118. INSTALLED A NEW FABRICATED FLOOR SUPPORT CAP IAW SRM.SDR SWIA2019122747448Floor Support · corrodedRBL 9 FLOOR SUPPORT CAP INBOARD FLANGE HAD CORROSION AT MULTIPLE LOCATIONS BETWEEN BS 409+118 AND 409+128. REMOVED CORROSION AND FOUND OUT OF LIMITS, REPAIRED.SDR SWIA2019122747446Floor Support · corrodedLBL 9 FLOOR SUPPORT CAP INBOARD FLANGE HAD CORROSION AT MULTIPLE LOCATIONS BETWEEN BS 409+118 AND 409+128. REMOVED CORROSION AND FOUND OUT OF LIMITS, REPAIRED.SDR SWIA2019122747443Floor Support · corrodedLH FLOOR SUPPORT WAS CORRODED BETWEEN BS 409+32 AND 409+80. REMOVED CORROSION ON THE AFFECTED AREA. IAW SRM.SDR SWIA2019122747372Angle · bentAFT CARGO SURROUND FWD CAM TRACK SUPPORT LOWER FWD ANGLE BENT. REPLACED FWD CAM TRACK SUPPORT LOWER FWD ANGLE. REF SRM 51-42-06 AND DWG 601R35050 REV AC / COMPLIED WITH TASK CARD 51-900-1003 MAJOR REPAIRSDR QMLA2019120619093Support Frame · chafedTHE TRANSMISSION SUPPORT FRAME (PN 350A21-1041-143) HAS CHAFING DAMAGE ON THE LOWER FLANGE FROM AN UNSECURED CABLE. THE DAMAGE IS UNDER THE TRANSMISSION DECK AT THE AFT RH CORNER OF THE TRANSMISSION CUTOUT. ** THIS AIRCRAFT REMAINS OUT OF SERVICE AT THE TIME OSDR DALA2019112806955Web · corrodedCORROSION WEB LOCATED BTW FR 69 TO FR 70 LEVEL STR 23L UNDER FLOOR STRUCTURE IN BULK CARGO COMPARTMENT (1 EA) (SSI 534144). REPLACED FLOOR STRUCTURE ON SUPPORT WEB LOKATED BTW FR69 TO FR70 AT LEVEL STRG 23L IN PASSENGER CABIN ASPER A319 SRM 51-72-11 AND DWG D5SDR REXA2019112601682Support · cracked"AWR; PER MTC REQUEST: [ DURING REMOTION OF MLG WHEEL BINS RELATED WITH TASK 900-27-900-112 STEP 5 ]: CRACK IN LH FAIRING SUPPORT DIAPHRAGM IN STA. FS= 797 TO FS= 807 AND 35LBL AT LH MLG WHEEL WELL. (FYT)
"LH FAIRING SUPPORT DIAPHRAGM IN STA. FS= 797 TO FS= 8SDR SWAA2019112539098Gusset · crackedFORWARD CARGO GUSSET CRACKED AT BS. 500D, STR. 19L. / R&R GUSSET PER SRM AND DWG.SDR SWAA2019112539097Gusset · crackedFORWARD CARGO GUSSET CRACKED AT BS. 500D, STR. 19R. / R&R GUSSET PER SRM & DWG.SDR AALA201911229032Shear Plate · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SHEAR PLATE AT FR 70 AND S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR SWAA2019112038996Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS. 500D, STR. 19R. / R&R GUSSET IAW SRM AND DWG.SDR IPXA2019112049202Support Web · crackedINSPECTION TYPE:2CCENTER ACC. COMP CIELING AT STA. 6-90 AND RBL 85, SUPPORT WEB IS CRACKED.REMOVED, FABRICATED AND REPLACED WEB IAW DWG. ADA4562 AND SRM 51-35-01. (MINOR)SDR FDEA2019111522923Web · corrodedUPON FLOOR SUPPORT REMOVAL FOR REPAIR - LOWER CENTER CARGO AFT BULKHEAD RIGHT HAND WEB FOUND WITH CORROSION AT STATION 1841 X=-20 TO X=-40 . LOWER CENTER CARGO AFT BULKHEAD RIGHT HAND AT STATION 1841,X=-20 TO X=-40 CORROSION WEB REMOVED AS PER SRM 51-21-01SDR FDEA201911122921Web · crackedAFT LOWER CARGO COMPARTMENT LEFT HAND FLOOR WEB AT STATION 1841,X=39 UNDERNEATH PANEL 187EF FOUND CRACKED. AFT LOWER CARGO COMPARTMENT LEFT HAND FLOOR AT STATION 1841,X=39 UNDERNEATH PANEL 187EF CRACKED WEB REMOVED AND INSTALLED WITH FABRICATED WEB AS PER SDR DALA2019111536722Support · damaged(LOG 1357113) DURIING INSPECTION FOUND CORROSION ON RH SIDEPLATE-SUPPORT ZEE STATION 500B+3" ALSO SCRATCH STA 500B+17" AND CRACK ON STA 500C+2" AT FWD CARGO COMPARTMENT. SIDE PLATE WAS REPLACED PER B737-800 SRM 53-00-53-2R-5, B737-800 SRM 51-40-02.SDR DALA2019111436693Floor Support · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 12 TO FR 24 AND -Y765 IN PASSENGER CABIN (1 EA), REPLACED FLOOR BEAM AND FASTENERS LOCATED BTW FR12 TO FR24 AND -Y765 IN PASSENGER CABIN AS PER SRM A320 51-72-11 AND DRAWING D53110920 AND D53112812SDR DALA2019111206692Floor Support · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 68 TO FR 69 AND -Y 1292 AFT IN PASSENGER CABIN (1 EA), REPLACED FLOOR BEAM -Y1292 LOCATED BTW FR.68 TO FR.69 AFT IN PASSENGER CABIN (1E/A) AS PER A320 SRM 51-72-11 AND DWG #D53472001SDR DALA2019111426691Floor Support · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 66 TO FR 67+18 INCH AND -Y 1292 IN PASSENGER CABIN (1 EA), REPLACED FLOOR BEAM LOCATED BTW FR.66 TO FR.67+18 INCH AND -Y1292 IN PASSENGER CABIN (1E/A) AS PER A320 SRM 51-72-11 AND DWG#53472780