JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023071105595Unknown · unknown(LOG 2855770) CRACKED FLOOR STRUCTURE SUPPORT ANGLE LOCATED BS 540, LBL 2, CENTER SECT ION AT PASSENGER CABIN. REPLACED FLOOR STRUCTURE SUPPORT ANGLE (SUPPORT PANEL) LOC. BS 540, LBL 2, CENTER SECTION AT PASSENGER CABIN AS PER B737-900ERSRM 51-40-02 AND SRM 51SDR DALA2023071005582Unknown · unknownSHIP 3355 CORROSION ON FLOOR BEAM Y2462 LOCATED FR32 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y2462 LOCATED BTW FR32 TO FR37 IN PASSENGER CABIN. (2856034)SDR DALA2023071005581Unknown · unknownSHIP 3355 CORROSION FLOOR BEAM +Y1959 LOCATED FR31 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y1959 LOCATED FR31 TO FR37 IN PASSENGER CABIN. (2854925)SDR UIEA2023070500703Unknown · unknownUPPER HALF FUSELAGE SKIN BETWEEN STA 544 / STA 566 AND STRINGER S-1 RH WITH LIGHTNING STRIKE DAMAGE(<P> LIGHTNING STRIKE DAMAGE WAS REPAIRED PER SRM53-00-01-2R-8, REPAIR 8, FIG 201 REQUIREMENTS. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2023070500694Unknown · unknownUPPER FUSELAGE SKIN BETWEEN STA 566 / STA 588 AND S-1 RH WITH LIGHTNING STRIKE DAMAGE(<P>LIGHTNING STRIKE DAMAGE WAS REPAIRED PER SRM 53-00-01-2R-8, REPAIR 8, FIG 201 REQUIREMENTS. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2023070500693Unknown · unknownUPPER FUSELAGE SKIN BETWEEN STA 544 / STA 566 AND S-1 RH / S-2 RH WITH LIGHTNING STRIKE DAMAGE(<P>LIGHTNING STRIKE DAMAGE WAS REPAIRED PER SRM 53-00-01-2R-8, REPAIR 8, FIG 201 REQUIREMENTS. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2023070500692Unknown · unknownUPPER FUSELAGE SKIN BETWEEN STA 456 / STA 478 AND S-1 RH / S-2 RH WITH LIGHTNING STRIKE DAMAGE(<P>LIGHTNING STRIKE DAMAGE WAS REPAIRED PER SRM 53-00-01-2R-8, REPAIR 8, FIG 201 REQUIREMENTS. NO FURTHER DEFECTS NOTED</P>)SDR CALA2023071002200Door Sill · corrodedR2 DOOR SILL HAS CORROSION AT FR66 AND FR68 PER HAECO LCQ N/R 9294633/24633 GEN BY V061603SDR IXXA2023070804Pan · crackedDURING MAINTENANCE VISIT AT VT-SAA, MAINTENANCE FOUND 0.85 INCH CRACK IN THE AFT CARGO COMPARTMENT PDU PAN AT 7L POSITION. ACCOMPLISHED PERMANENT WELD REPAIR IAW FVCI EO 23130-11 REV ASDR ASAA2023070745418Door Sill · corrodedMAIN CABIN R1 DOOR LOWER CORNER, AFT GIRT BAR PLATE DRAIN ACCESS HOLE HAS CORROSION (MARKED IN RED) GROUNDED - YES. REMOVED CORROSION AROUND R1 DOOR AFT GIRT BAR DRAIN, ORIG .197 MATERIAL LOSS .007 REMAINING .190 FOUND TO BE WITHIN LIMITS, HFEC DVI NO DEFECTS SDR ASAA2023070745415Door Sill · corrodedMAIN CABIN L1 DOOR LOWER CORNER; AFT GIRT BAR PLATE AREA HAS CORROSION ON SKIN AND (4EA) HILOSCK PINS (MARKED IN RED) GROUNDED - YES. REMOVED AND INSTALLED NEW LOWER SILL REF AIRBUS DWG D53135033 ISSUE B AND A320 SRM 51-42-11/001 REMOVED CORROSION ORIG. .197 MSDR ASAA2023070745414Door Sill · corrodedMAIN CABIN L1 DOOR LOWER CORNER; FWD GIRT BAR PLATE AREA HAS CORROSION ON SKIN AND (4EA) HILOSCK PINS(MARKED IN RED) GROUNDED - YES. REMOVED AND INSTALLED NEW SILL REF AIRBUS DWG D53135033 ISSUE B AND A320 SRM 51-42-11/001 ALL WORK ACCOMPLISHED ON CUSTOMER CARSDR ASAA2023070745352Door Sill · corrodedMAIN CABIN R1 DOOR LOWER CORNER; AFT GRIT BAR PLATE AREA HAS CORROSION ON SKIN AND (4EA) HILOSCK PINS (MARKED IN RED) GROUNDED - YES. REMOVED DAMAGE ON SILL FR19 AND FR20 AT -Y1950 LOWEST MATERIAL LOSS .142, HFEC SURFACE AND OPEN HOLE AND DVI NO DEFECTS NOTED.SDR ASAA2023070745351Door Sill · corrodedMAIN CABIN R1 DOOR CORNER; FWD GIRT BAR PLATE AREA HAS CORROSION ON SKIN AND (4EA) HILOSCK PINS (MARKED IN RED) GROUNDED - YES. REMOVED DAMAGE ON SILL BETWEEN FR16 AND FR17 AT -Y1952 LOWEST MATERIAL LOSS .134, HFEC AND OPEN HOLE AND DVI NO DEFECTS NOTED. FABRSDR SWIA20230707Unknown · corrodedDATUM 1 INTERCOSTAL BETWEEN APPROX FS320 - FS338 HAS CORROSION (C-CHECK RO 9/6/2023) REMOVED AND INSTALLED NEWLY DRILLED INTERCOSTAL D1 BETWEEN FS320 - FS338 REF CRJ200 SRM 51-42-06 REF CRJ200 SRM 51-42-21 AND DWG 601R31702 REV-N. COMPLIED WITH 51-900-1SDR SWAA2023081576005Support · corrodedCORROSION AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE MULTIPLE AREAS AROUND NUT PLATE HOLES BS727E+19' TO BS767+10' LBL22 WL156<[01] CORROSION FOUND TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION; FABRICATED REPAIR PARTS; INSTALLED REPAIR PARTS FOR ACB LH SDR SWAA2023081576015Support · corrodedCORROSION AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS AROUND NUT PLATE HOLES BS727D+12' TO BS767 RBL22 WL156<[01] DAMAGED ACB R/H FLOOR TO SIDEWALL SUPPORT BS727+4' TO BS767; RBL22; WL156 WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-SDR SWAA2023081576006Shield · corrodedCORROSION FWD CARGO BAY AFT SHIELD BS500+3 TO BS500+16 RBL22 WL156 HAS MULTIPLE AREAS AROUND NUT PLATE HOLES<[01] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.SDR SWAA2023081576002Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE CRACKED<[01] WELDED CRACK ON AFT CARGO BAY AFT CORNER SCUFF PLATE USING ER4043 ALUMINUM FILLER ROD LOT NUMBER 1131216 PER SRM 53-60-15-2R-1 PARAGRAPH 4.B.(2) AND (4). REPAIR AREA STILL REQUIRES A DYE PENETRANT INSPECTION.<BSDR SWAA2023080976404Support Angle · crackedCRACKED SUPPORT ANGLE FOR CHANNEL; BS 692.5 - 694 RBL 24 WL 203<[01] UPDATED MEASUREMENTS TABLE;[02] REMOVED DAMAGED SUPPORT ANGLE FOR CHANNEL FROM BS 692.5 TO BS 694; RBL 24; WL 203 IAW SRM 51-40-02-0G-0;[03] CERTIFY;[04] SRM DOESN'T HAVE ALLOWABLE DAMAGE/REPSDR SWAA2023080176431Intercostal · corrodedAFT. CARGO R/H SIDE UNDER TRANSITION ANGLE (SIDE-PLATE) RBL. 21 WEB/INTERCOSTAL HAS CORROSION AROUND NUT-PLATE HOLES. AFT. CARGO R/H SIDE UNDER TRANSITION ANGLE (SIDE-PLATE) RBL. 21 WEB/INTERCOSTAL HAS CORROSION AROUND NUT-PLATE HOLES. STA.747-767<[01] REMOVEDSDR SWAA2023073176430Intercostal · corrodedAFT. CARGO R/H SIDE UNDER TRANSITION ANGLE (SIDE-PLATE) RBL. 21 WEB/INTERCOSTAL HAS CORROSION AROUND NUT-PLATE HOLES. STA. 747-767. AFT. CARGO R/H SIDE UNDER TRANSITION ANGLE (SIDE-PLATE) RBL. 21 WEB/INTERCOSTAL HAS CORROSION AROUND NUT-PLATE HOLES.<[01] REMOVSDR SWAA2023073176433Angle · corrodedAFT. CARGO L/H TRANSITION ANGLE LBL. 21 STA.727H+10 TO STA.807+10 HAS CORROSION IN SEVERAL AREAS.<[01] CUT AND REMOVED DAMAGED SECTION PER SRM 53-00-53-2R-5. SECTION OUT OF LIMITS;[02] C/W INSPECTION.;[03] REJECT: IN THE MEASUREMENTS SECTION; THE FOLLOWING ERRSDR SWAA2023073176432Angle · corrodedAFT. CARGO L/H TRANSITION ANGLE LBL. 21 STA.727H+10 TO STA.787+10 HAS CORROSION IN SEVERAL AREAS.<[01] CUT DAMAGED SECTION FROM STA.727H+10 TO 787+10 PER SRM 53-00-53-2R-5;[02] CUT DAMAGED SECTION FROM STA.727H+10 TO 787+10 PER SRM 53-00-53-2R-5 SECTION IS OUTSDR DALA2023071105594Channel · corroded(LOG 2854129) CORROSION AFT CARGO R/H Z CHANNEL STA 727D TO STA 727I STR 25. REMOVED & REPLACED R/H ZEE CHANNEL @ STA 727C+10 -STA 767 IAW B737 SRM 53-00-53-2R PROCEDURE 5, B737 SRM 51-40-02 & BOEING DWG 146A7500.SDR DALA2023071105593Unknown · unknown(LOG 2853856) CORROSION IN AFT CARGO COMPARTMENT FLOOR STRUCTURE CARGO TRACK-TIE DOWN SUPPORT BETWEEN BS. 795 AND BS.835 RBL.13.84. REMOVED AND REPLACED TRACK IAW B737-900 SRM 51-40-02 AND DWG# 146A7500 REV G.SDR DALA2023071105592Unknown · unknown(LOG 2853672) AFT CARGO COMPARTMENT R/H FLOOR BAFFLE STA 747-767 DAMAGED. REMOVED AND REPLACED DAMAGED R/H FLOOR BAFFLE @ STA 747-767 IN AFT CARGO IAW B737 SRM 51-40-02, 51-40-05 & BOEING DWGS 146A7500, 146A7502.SDR DALA2023071105591Unknown · unknown(LOG 2853654) FWD WET AREA TOOL MARKS AT FLOOR SUPPORT STA 312 TO STA 328 LBL 10 WL 208. REMOVED AND REPLACED FLOOR SUPPORT AT STA 312 TO STA 328 LBL 10 IAW B737 SRM 51-40-02-0G AND BOEING DWG# 141A5400.SDR DALA2023071005549Unknown · unknownSHIP 3123 CORROSION INTERNAL STRUCTURE WEB LOCATED FR30 TO FR34 AND STR38R IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED WEB LOCATED FR30 TO FR34 AND STR38R IN FWD CARGO COMPARTMENT AS PER A319 SRM 51-42-11 AND SRM 51-72-11. (2853889)SDR DALA2023071005548Unknown · unknownSHIP 3123 CORROSION INTERNAL STRUCTURE WEB LOCATED FR30 TO FR34 AND STR38L IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED WEB LOCATED ON INTERNAL STRUCTURE FR30 TO FR34 AND STR38L IN FWD CARGO COMPARTMENT AS PER A319 SRM 51-42-11 AND SRM 51-72-11. (2853SDR JR2R20230707014Gusset · corrodedAFT CABIN FLOOR TEXAS DOUBLER CORRODED ON FR90 RBL27 AREASDR JR2R20230707013Gusset · corrodedAFT CABIN FLOOR TEXAS DOUBLER CORRODED ON FR90 RBL27 AREASDR JR2R202307070013Channel · corrodedAFT CABIN FLOOR O/B SUPPORT CORRODED BETWEEN FR88 AND FR90 AT R2 DOOR AREASDR JR2R20230707012Support · corrodedAFT CABIN FLOOR PANEL SUPPORT ANGLECORRODED FWD SIDE OF FR87 AT L2 DOOR AREASDR JR2R20230707009Shear Panel · corrodedAFT CABIN FLOOR WEB CORRODED MULTIPLE AREA BETWEEN FR87 AND FR88 AFT OF THE R2 DOORSDR JR2R20230707011Shear Panel · corrodedAFT CABIN FLOOR CENTER WEB CORRODED MULTIPLE AREA BETWEEN FR87 AND FR88SDR JR2R20230707010Shear Panel · corrodedAFT CABIN FLOOR WEB CORRODED MULTIPLE AREA BETWEEN FR87 AND FR88 AFT OF THE L2 DOORSDR SWAA2023082975865Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS284 BL0 WL208.<[01] UPON INVESTIGATION FOUND NO ALLOWABLE DAMAGE AND THE PART WILL BE REPLACED IAW SRM 51-10-02-0G-0 STEP 9.;[02] REMOVED CRACKED INTERCOSTAL AND RECEIVED THE NEW INTERCOSTAL P/N 141A5410U3AAR; LOT # 240019. LSDR SWAA2023082975868Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+9 LBL11 WL208.<[01] PARTIAL STEP 3;[02] REMOVED AND REPLACED INTERCOSTAL AT FWD CABIN BS344+9 LBL11 WL208.;[03] REMOVED & REPLACED INTERCOSTAL AT FWD CABIN BS344+9 LBL11 WL208 IAW SRM 51-40-02-0G-0 AND DWG 141A5400.;[04] SDR SWAA2023082975857Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS312+10 LBL45 WL208.<[01] UPON INVESTIGATION FOUND NO ALLOWABLE DAMAGE AND THE PART WILL BE REPLACED IAW SRM 51-10-02-0G-0 STEP 9.;[02] REMOVED CRACKED INTERCOSTAL AND RECEIVED THE NEW INTERCOSTAL 236728. LOCATED; DRILLED; & DSDR SWAA2023082975869Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS328+8 LBL45 WL208.<[01] UPON FURTHER INVESTIGATION FOUND NO ALLOWABLE DAMAGE AND THE PART WILL BE REPLACED IAW SRM 51-10-02-0G-0 STEP 9.;[02] REMOVED CRACKED INTERCOSTAL AND RECEIVED A NEW INTERCOSTAL 1533852-1. LOCATED; DRILSDR SWAA2023082975870Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+5 RBL12 WL208.<[01] PARTIALLY COMPLETED STEPS 1 AND 2. NEED OK TO INSTALL.;[02] PARTIALLY COMPLETED STEP 3.;[03] VERIFIED APPLICABILITY OF SRM 53-10-51-1A-1 CRACKED INTERCOSTAL AT BS 344+5 RBL 12 WL 208 FOUND TO BE OUT OFSDR SWAA2023082975860Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+5 RBL32 WL208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-51-1A-1 ALLOWABLE DAMAGE;[02] CRACK DAMAGED INTERCOSTAL CRACKED 0.6330 LONG THRU FASTENER HOLE FOR AND AFT; ORIGINAL THICKNESS 0.0630 FOUND TO BE OUT OF LIMITS IAW SSDR SWAA2023082975874Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+5 RBL50 WL208.<[01] NO LIMITS FOUND IN SRM FOR TYPE OF DAMAGE.<BR>DAMAGE TO BE REMOVED PER SRM 51-10-02-0G-0 AND SUBMITTED TO ENGINEERING FOR FURTHER REPAIR INSTRUCTIONS .;[02] CUT OUT CRACK IN INTERCOSTAL FLANGE AT BS344SDR SWAA2023082975854Angle · corrodedCORROSION ON BS 277 LBL 40-LBL45 WL 208 LATERAL UPPER SURFACE CHORD ANGLE<[01] NO ALLOWABLE LIMITS FOUND ON SRM DAMAGE REMOVED PER SRM 51-10-02-0G-0 5'X1' AREA ORIGINAL MATERIAL THICKNESS IS 0.100' REMAINING LOWEST MATERIAL THICKNESS IS 0.062' SUBMMITED INFORMSDR SWAA2023082975866Floor Support · corrodedCORROSION ON FLOOR SUPPORT AT FWD CABIN BS294+13 LBL11 WL208.<[01] NO ENTRIES FOUND ON SRM DAMAGE REMOVED I.A.W ORIGINAL MATERIAL THICKNESS IS 0.080' REMAINING MATERIAL THICKNESS IS 0.040 PART TO BE REMOVE AND REPLACE I.A.W SRM 51-10-02-0G-0 PAR 9.A(1);C;[02] SDR SWAA2023082975872Channel · corrodedCORROSION ON FSD MOP SILL BS294+7 RBL54 WL208.<[01] VERIFIED APLICABILITTY OF SRM 53-10-15-1A-2;[02] EVALUATED CORROSION ON FSD MOP SILL BS294+7 RBL54 WL208 1'X1' ORIGINAL MATERIAL THICKNESS IS 0.080' REMAINING MATERIAL THICKNESS IS 0.020' DAMAGE FOUND TO BE OSDR SWAA2023082975873Support · corrodedCORROSION ON FSD THRESHOLD SUPPORT BS312+3 RBL54 WL208.<[01] VERIFIED APLICABILITTY OF SRM 53-10-15-1A-2;[02] REMOVED CORROSION OF FWD SERVICE DOOR MOPSILL THRESHOLD ATTACH ANGLE BS 312+3; RBL54; WL 208 1'X1'AREA AND FOUND OUT LIMITS; MATERIAL THICKNESS 0.090'SDR SWAA2023082975861Web · corrodedCORROSION ON 1016 WEB BS1016+12 LBL7 - LBL20 WL208.<[01] NO ENTRIES FOUND ON SRM;REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR 9.C <BR>UPDATED TABLE MEASUREMENT;[02] VERIFIED CORRECTIVE ACTION 1;[03] REMOVED WEB AT BS 1016-BS 1026; BL0-LBL3SDR SWAA2023082975875Web · corrodedCORROSION ON 1016 WEB AT AFT CABIN LBL10 WL208.<[01] NO ENTRIES FOUND ON SRM;REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR 9.C PART TO BE REMOVE AND REPLACE ON COSTUMER CARD TTG8Q00M284B<BR>UPDATED TABLE MEASUREMENT;[02] COMPLETED TASK;[03]
Back to JASC 5320