SDR AALA202306269092Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON MAIN CABIN AFT WET AREA Z ANGLE LOCATED AT BS 990 FROM LBL 33 TO LBL 40. REPLACED ANGLE PER SRM SRM 51-40-05 AND DWG 147A5700 REV B.SDR SWI2023F00291Unknown · corrodedMAIN AVIONICS BAY STR 24R BETWEEN FS333.00 AND FS349.00 (C-CHECK RO 8/31/2023) REMOVED AND INSTALLED NEW SECTION OF STR 24R FROM FS333.00 TO FS356.00 REF. DRWG SH690-31350 REV.M AND CRJ 700 SRM 53-00-03-201-001-A01. PERFORMED PRESSURE CHECK THROUGH REPASDR SWI2023F00290Unknown · corrodedMAIN AVIONICS BAY STR 23R CORRODED BETWEEN FS295.00 AND FS310.00 (C-CHECK RO 8/31/2023) REMOVED AND INSTALLED NEW MAIN AVIONICS BAY STR 23R FROM FS280.00 TO FS333.00 REF. DWG SH670-31630 REV K, CRJ 700 SRM 51-42-06-001-001-A01 AND CRJ 700 SRM 51-42-21-SDR SWI2023F00289Unknown · corrodedMAIN AVIONICS BAY STR 24L BETWEEN FS295.00 AND FS310.00 (C-CHECK RO 8/31/2023) REMOVED AND INSTALLED NEW MAIN AVIONICS BAY STR 24L FROM FS280.00 TO FS333.00 REF. DWG SH670-31630 REV K, CRJ 700 SRM 51-42-06-001-001-A01 AND CRJ 700 SRM 51-42-21-001-001-A0SDR SWIA20230623Unknown · corrodedMAIN AVIONICS BAY STR 23R BETWEEN FS349.00 AND FS364.00 (C-CHECK RO 8/31/2023) REMOVED AND REPLACED MAIN AVIONICS BAY STR 23R FROM FS333 TO FS379 REF DWG SH690-31350 REV M, CRJ-700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01. COMPLIED WITH 51-SDR SWAA2023072870656Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS695 AND RBL24.75 WL203 CENTER SECTION 2023-404893<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112811019; DUE DATE: 25-JAN-24.;[02SDR SWAA2023072870643Fitting · wornWEAR ON GIRT BAR FITTING HARDWARE ENTRY DOOR AT FWD GALLEY AREA 2023 404876<[01] REPLACED GIRT BAR FITTING HARDWARE ENTRY DOOR AT FWD GALLEY AREA I.A.W B737-700 AMM 25-66-02-400-801. THE INSTALLATION IS DOCUMENTED ON MT J725-025-00-01Y (TTG8Q003FBA5);[02] REPLSDR SWAA2023072671357Intercostal · corrodedAFT GALLEY FLOOR STRUCTURE INTERCOSTAL STA. 951 RBL 54 (ADJACENT TO R/H O/B LAV MOUNT) HAS CORROSION. (MARKED)<[01] REMOVED CORROSION WITHIN LIMITS PER SRM53-70-51-1A-1. OK TO TREAT AND PAINT.;[02] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-SDR SWAA2023072671358Angle · corrodedAFT GALLEY DOOR CUTOUT Z ANGLE STA. 967-987 RBL 47; HAS CORROSION. (MARKED)<[01] REMOVED CORROSION WITHIN LIMITS PER SRM53-70-51-1A-1. OK TO TREAT AND PAINT.;[02] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. OK TO TREAT AND PAINT.;[03] RSDR SWAA2023072671355Angle · corrodedAFT GALLEY FLOOR STRUCTURE STA. 947.5 LBL 56; AFT ENTRY 'Z' ANGLE HAS CORROSION AROUND NUT PLATE HOLES. AREA MARKED IS ADJACENT TO 2 HI LOCKS AND NOT AROUND NUTPLATE HOLES<[01] CORRECTED LOCATION TO STA 947.5 ON MEASUREMENTS.;[02] REMOVED CORROSION WITHIN LIMISDR SWAA2023071971219Floor Support · corrodedCORROSION ON FLOOR SUPPORT BS 949 RBL 51 WL 208<[01] VERIFIED APPLICABILITY PER SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1;[02] EVALUATED CORROSION ON FLOOR SUPPORT STA 949; RBL 51; WL 208 1'X0.600' INCH LOWEST MATERIAL REMOVED IS 0.040' ADJACENT TO ORIGINAL MATERIASDR CALA2023071702268Floor Support · corrodedFLOOR BEAM Y765 UPPER SURFACE HAS SEVERAL SPOTS WITH CORROSION FR66 TO FR68 DOT 41-20 REMOVED CORROSION IAW SRM 51-74-00 D: 0.045 OUT OF LIMITS IAW SR 51-75-12 SEE ATTACHMENT 44-0008 EMP#: V936322 WORK ACCOMPLISHED M 53-41-14-283-009, RECEIVE NEW PART, P/N D53SDR AALA202307050560Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOORBOARD SUPPORT LOCATED AT BS 540 AND RBL 1. REPLACED FLOORBOARD SUPPORT PER AARD 51-00-05-1.SDR FDEA202306231135Angle · crackedAVIONICS COMP'T BELOW COCKPIT FLOOR PICK UP ANGLE CRACK AT Y403,FR10 POSITION. REPLACED THE ANGLE BY NEW ONE WITH RIVETS I.A.W A300-600F SRM 51-72-10-001 PAGE 2.SDR DALA2023062605113Unknown · unknown(LOG 2830603) CORROSION ON AFT CARGO COMPARTMENT INTERNAL BELLY DRAIN DOUBLER AT STA 949 BL 0 WL 170. REMOVED AND REPLACED BELLY DRAIN DOUBLER STA 949 BL0 WL170 IAW B737 51-40-02 AND DWG# 147A3424.SDR DALA2023062605112Panel · corroded(LOG 2830077) FORWARD CARGO COMPARTMENT RH FLOOR TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION ON UPPER SURFACE BETWEEN BS 500A AND BS 500 L RBL 26. INSTALLED NEW FORWARD CARGO COMPARTMENT RH FLOOR TRANSITION PANEL BS 500A TO BS 500 L. RBL 26. IAW B737 SRM 5SDR CALA2023062602002Intercostal · corroded(SUPPORT TASK) MAIN CABIN FLOOR STRUCTURE INTERCOSTAL AT STA 294 .5 - 312 LBL12 CORRODED. TRANSCRIBED FROM HAECO GSO NR 9282393 MECH V901143 CORROSION REMOVAL OF 0.050" FROM ORIGINAL 0.170", REMAINING 0.12 0" FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-10-5SDR AALA202306231398Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND SIDE WALL TRANSITION PANEL LOCATED FROM BS 500A TO BS 500D + 10 INCHES, AT S25R. REPAIRED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 5.SDR AALA202310122374Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND SIDE WALL TRANSITION PANEL LOCATED FROM BS 400 TO BS 420 AT S25R. REPLACED TRANSITION PANEL PER SRM 51-40-02-0G. SUPPLEMENTAL REPORT FOR AALA202306232374: QC REVIEWED THIS EVENT ANSDR SWI2023F00302Unknown · corrodedBELOW AFT BAGGAGE BAY FLOOR,LEFT FS1000.0 CROSS BEAM CORROSION (MARKED) (C-CHECK RO 8/31/2023) AFT BAGGAGE BAY FLOOR LEFT OF F/S 1000 CROSS BEAM REPAIRED ALL STEPS COMPLIED WITH IAW REO 670-53-61-2134 REV. -- DATED 2023-07-18 COMPLIED WITH SKYWEST TASK SDR SWIA202309016022Unknown · corrodedBELOW AFT BAGGAGE BAY FLOOR, LEFT FLOOR SILL FS696.0-FS985.0 CORROSION (MARKED) (C-CHECK RO 8/31/2023) REMOVED CORROSION ON 2 AREAS ON LH FLOOR SILL BETWEEN FS969 AND FS985 AND REMOVED ADDITIONAL CORROSION AT FS966 LEFT FLOOR SILL IAW CRJ700 SRM 51-21-SDR VNAA202307290005Door Sill · corrodedSERVICE DOOR SILL UPPER SURFACE HAS AREA OF CORROSION APPROXIMATELY FS 326.00 ADJACENT TO FWD SERVICE DOOR FITTINGSDR SWAA2023072870674Scuff Plate · crackedFWD CARGO DOOR CUTOUT LOWER SILL FWD SCUFF PLATE CRACKED MKD DOT<[01] RECEIVED WELDED SCUFF PLATE FROM OUTSIDE VENDOR J.L. WELDING ;P.O#2012626; TAG#426643; WHICH ACCOMPLISHED WELD REPAIR AS PER SRM 53-30-15-2R-1. THIS SCUFF PLATE WILL BE INSTALL ON FAULT #TTGSDR SWAA2023072570502Stiffener · crackedCUSTOMER REQUEST CRACK ON STIFFENER LOCATED BS663.75 AND RBL 25 MAIN WHEEL WELL 2023-409384<[01] REPLACED STIFFENER LOCATED BS663.75 AND RBL 25 MAIN WHEEL WELL B737-700 SRM 51-10-02 ITEM 9 AND DWG:111A1000 SHEET:258 REV:A. SEE INDIVIDUAL SIGN OFF BELOW;[02] RESDR ASAA2023062244132Web · corrodedFWD CARGO DOOR LOWER SILL HAS AREA OF CORROSION. GROUNDED - YES. REMOVED & REPLACED FWD CARGO DOOR LOWER SILL IAW B737-900 SRM 51-40-02-0G-0.W= 1.25" O= .045" R= .031" L= 3" D= .014".SDR ASAA2023062244131Transition Panel · corrodedAFT CARGO LH TRANSITION PNL HAS MULITPLE AREAS OF CORR BETWEEN STA 727+4 TO STA 727C+10. GROUNDED - YES. REMOVED & REPLACED LH TRANSITION PNL FROM STA 727+4 TO STA 727C+10 IAW B737-900 SRM 53-00-53-2R-6.SDR ASAA2023062244130Transition Panel · corrodedFWD CARGO R/H TRANSITION CORRODED BETWEEN STA 500J+8 TO STA 520. GROUNDED - YES. REMOVED AND REPLACED TRANSITION PANEL FROM STA 500J+8 TO STA 520 IAW B737-900 SRM 51-40-02-0G-0.W= .05 O= 0.040 R= 0.024 L= 1.00 D= 0.16.SDR ASAA2023062244129Transition Panel · corrodedFWD CARGO R/H TRANSITION PANEL HAS MULTIIPLE AREAS OF CORROSION BETWEEN STA 500D+ TO STA 500I+8. GROUNDED - YES. REMOVED AND REPLACED TRANSITION FROM STA 500D TO 500I+8 IAW B737-900 SRM 51-40-02-0G-0.W= 2" O= .040" R= .024 L= 2" D= .016.SDR AALA202307180969Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT AFT PASSENGER / CREW DOOR CUTOUT LOWER AFT CORNER SHAPE FITTING AT FR 68 AND S23R. REPLACED AFT CORNER SHAPE FITTING PER SRM 51-42-11.SDR AALA202307181341Angle · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT AFT PASSENGER / CREW DOOR CUTOUT LOWER SILL ANGLE HAS ELONGATED FASTENER HOLES AT FR 67 AND S23R. REPLACED ANGLE PER SRM 51-72-11.SDR REXA2022071700504Web · corrodedL/H FS 280 LOWER WEB IS CORRODED AT LBL !2 BEHIND CORROSION CAP AND CROSSBEAM REPAIRED IAW CRJ-900 SRM 53-11-10-201-004-A01.SDR REXA2022071700502Web · corrodedR/H FS 280 LOWER WEB IS CORRODED BETWEEN RBL 36.00 TO RBL 45.00 REPAIRED IAW CRJ-900 SRM 53-11-10-201-004-A01.SDR REXA2022071700501Angle · corroded" F.S. 280 FWD J ANGLE IS CORRODED. INSTALLED NEW SERVICEABLE F.S. 280 ""J"" ANGLE P/N CC670-34095-1 IAW CRJ-900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. "SDR FDEA202306221229Panel · damagedMAINTENANCE PLATFORM SOFT AT TRIM TANK FR87-FR91. FABRICATED THE PLATFORM PANEL I.A.W FEDEX DRAWING SRZ-25-005 "MAJOR REPAIR"SDR AALA202307056468Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOORBOARD SUPPORT LOCATED AT BS 540 AND LBL 1. REPLACED FLOORBOARD SUPPORT PER AARD 51-00-05.SDR DALA2023062605111Unknown · unknown(LOG 2828990) CORROSION AROUND FASTENER HOLES IN AFT CARGO COMPARTMENT FLOOR STRUCTURE LT SIDE TRANSITION PANEL SECTION BETWEEN BS.727A AND BS.727I+8 LBL.21.00. REMOVED, FABRICATED NEW SECTION AND INSTALLED IAW B737-900 SRM 51-40-02.SDR AALA202306230921Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN MAIN CABIN FLOOR STRUCTURE INTERCOSTAL ANGLE LOCATED FROM BS 380 TO BS 400 AT BL 0. REPLACED ANGLE PER DWG 143A5400.SDR AALA202306231165Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND SIDE WALL TRANSITION PANEL LOCATED FROM BS 420 TO BS 440 AT S25R. REMOVED, FABRICATED, AND INSTALLED TRANSITION PANEL PER SRM 51-40-02-0G.SDR AALA202306232374Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND SIDE WALL TRANSITION PANEL LOCATED FROM BS 400 TO BS 420 AT S25R. REPLACED TRANSITION PANEL PER SRM 51-40-02-0G.SDR AALA202306233952Unknown · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON MAIN CABIN LEFT HAND MOP SILL (INNER CHORD) LOCATED AT BS 640 AND LBL 64. REMOVED, FABRICATED, AND INSTALLED MOP SILL PER SRM 51-40-02-0G.SDR AALA202306235050Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN AFT CARGO COMPARTMENT INTERCOSTAL LOCATED FROM BS 907 TO BS 927 BETWEEN S23L AND S24L. REPLACED INTERCOSTAL PER SRM 51-40-02-0G.SDR AALA202306236885Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCED: CORROSION ON AFT CARGO COMPARTMENT LEFT HAND TRANSITION PANEL LOCATED FROM BS 727B TO 847 AT S25L. REMOVED, FABRICATED, AND INSTALLED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 6 REPAIR 6.SDR SWAA2023072870145Scuff Plate · crackedAFT CARGO COMPARTMENT; FWD SCUFF PLATE HAS CRACKED.<[01] RECEIVED WELDED SCUFF PLATE FROM OUTSIDE VENDOR J.L. WELDING ;P.O#2012626; TAG#426643; THIS SCUFF PLATE WILL BE INSTALL ON FAULT #TTG8Q001S74N.;[02] (AMENDING STEP 1) RECEIVED WELDED SCUFF PLATE FROM OUTSDR SWAA2023072570170Angle · crackedCRACK ANGLE BTW BS 907 TO BS 927 AND BTW S 25R TO S 26R AT AFT CARGO COMPARTMENT 2023-394775<[01] TOOL USED DIGITAL CALIPER P/N: 500-196-30 S/N: A20227391 DUE DATE: 11/OCT/23;[02] REPLACED ANGLE LOCATED BTW BS 907 TO BS 927 AND BTW S 25R TO S 27R AT AFT CARGO SDR SWI2023F00132Unknown · corrodedCORROSION, AFT WET AREA, ON RH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE CENTER AND RH SHEAR PANELS. (C-CHECK RO 7/12/2023) REMOVED AND REPLACED RH LONGITUDINAL FLOOR BEAM AT FR 87. REF EMB SRM 51-40-08. THIS ACTION DOES NOT SDR R61A2023070700381Support · corrodedCORROSION FOUND ON UPPER FLANGE CROSSBEAM @ FWD FUSE FR14 RBL30-35.REPLACED UPPER SUPPORT PN 170-13939-001 IAW SRM 53-00-10 #3 FIG 203SDR SWAA2023070570163Web · crackedDOT A24-07 LH A/C BAY. METAL WEB COMMON TO VAPOR BARRIER AND PACK EXHAUST SEAL CRACKED JUST I/B OF EXHAUST SEAL.<[01] AUDIT C/WSDR DALA2023062605110Unknown · unknown(LOG 2827423) AFT CARGO ENTRY PANEL UNDER THRESHOLD HAS MULTIPLE AREAS OF CORROSION. REPAIRED AREA PER DELTA ERA 609690-14 REV ORIGINAL.SDR DALA2023062605108Shield · corroded(LOG 2827388) FWD CARGO COMPARTMENT AFT DOOR SHIELD FS 490-500A CORRODED. REMOVED AND REPLACED FWD CARGO DOOR SHIELD FS 490-500A IAW BOEING 737-800 SRM 51-40-02.SDR DALA2023062605107Unknown · unknown(LOG 2827268) FWD PIT WEB AT STA 500-500A RH HAS ELONGATED FASTENER HOLES. REMOVED AND REPLACED FWD PIT WEB AT STA 500-500A R/H IAW BOEING 737-800 SRM 51-40-02.
Back to JASC 5320