JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022072735432Angle · corrodedAPU COMPT CUTOUT; RH SIDE; ANGLE AT RBL 25 IS CORRODED AT NUTPLATE LOCATIONS (MARKED) / [01] UPDATED STEPS.<BR><BR>VERIFIED APPLICABILITY; NO FOUND ALLOWABLE DAMAGE ON SRM;[02] VERIFIED CORROSION REMOVAL PER SRM 51-10-02 STEP 15. SRM HAS NO ALLOWABLE LIMITS FOSDR SWAA2022072735433Angle · corrodedAPU COMPT CUTOUT; RH SIDE; ANGLE AT RBL 25 IS CORRODED AT NUTPLATE LOCATIONS (MARKED) / [01] UPDATED STEPS.<BR><BR>VERIFIED APPLICABILITY; NO FOUND ALLOWABLE DAMAGE ON SRM;[02] VERIFIED CORROSION REMOVAL PER SRM 51-10-02 STEP 15. SRM HAS NO ALLOWABLE LIMITS FOSDR SWAA2022071821664Intercostal · crackedFLOOR SUPPORT CRACKED BS344+9 LBL 11 WL 208 / [01] UPDATED MEASUREMENTS. REMOVED FLOOR SUPPORT INTERCOSTAL AT BS344+9 LBL11 WL208 IAW SRM 51-40-02.;[02] RECEIVED NEW INTERCOSTAL PO#873188; LOCATED HOLES; DRILLED; AND DEBURRED IAW SRM 51-40-05. ALSO; OK TO INSTSDR SWAA2022071821666Intercostal · crackedINTERCOSTAL CRACKED BS 277+8 BL 0 WL 208 / [01] REMOVED CRACKED INTERCOSTAL AT BS 277+8 BL0 WL208 IAW SRM 51-40-02. ALSO; UPDATED MEASUREMENTS.;[02] LOCATED AND DRILLED INTERCOSTAL BS 277-294 BL 0 WL 208 PER SRM 51-40-05-0G-0 AND DRAWING 141A5400.<BR>REQUEST OSDR SWAA2022071821667Shear Web · corrodedCORROSION ON SHEAR WEB STRAP BS 1016+4 LBL29 WL 208 / [01] REMOVED CORROSION AT BS 1016+4 LBL29 WL 208 AREA OF 2'X 1.5' PER SRM 53-70-51-1A-1;[02] VERIFIED CORRECTIVE ACTIONS STEP 1.;[03] SHEAR WEB STRAP IS OUT OF LIMITS DUE TO NO LIMITS; SRM 51-10-02-0G-0 IS SDR SWAA2022071821669Floor Support · corrodedCORROSION ON FLOOR SUPPORT BS 947+2 LBL 26 WL 208 / [01] REMOVED CORROSION ON FLOOR SUPPORT STA 947+2; LBL 26; WL 208. AREA BLENDED IS 3.4' BY 2' PER SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS; SRM 51-10-02-0G-0 IS APPLICABLE FOR RSDR SWAA2022071821670Channel · corrodedCORROSION ON ASD MOPSILL BS 947+16-967+18 RBL 57 L 208 / [01] REMOVED CORROSION ON ASD MOPSILL BS 947+16-BS 967+18 WL 208 IN AREA OF 25'X2' . ORGINAL THICKNESS .080 PER SRM 53-70-51-01-1;[02] REFERENCE IS SRM 53-70-15-1A-1;[03] CERTIFIED REFERENCE;[04] REFERENSDR R61A2022071400432Beam · corrodedFWD CARGO DOOR LOWER CUTOUT HAS CORROSION BY #2 LATCH FITTING AS MARKED. REMOVED AND REPLACED FWD CARGO LOWER BEAM REF EMB SRM 51-40-08SDR SWAA2022071221756Shield · corrodedAFT CARGO BAY SHIELD FWD OF THE DOOR HAS CORROSION BS767+5 RBL23 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767+5 RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] INSPECTED & VERIFIED CSDR SWAA2022071221757Intercostal · corrodedAFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD HAS CORROSION BS767+5 RBL23 WL156 / [01] EVALUATED CORROSION ON ANGLE BS 767+5 RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] INSPECTED & VERSDR SWAA2022071221758Shield · corrodedAFT CARGO BAY SHIELD AFT OF THE DOOR HAS CORROSION BS847+10 RBL23 WL164 / [01] EVALUATED CORROSION ON SHIELD BS 847+10 RBL 23 WL 164; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] INSPECTED & VERIFIEDSDR ASAA2022062238965Transition Panel · corrodedAFT CARGO L/H TRANSITION PANEL HAS SPOTS OF CORROSION. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS FOUND TRANSITION PANEL OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-2 REPAIRED TRANSITION PANEL IAW B737-800 SRM 53-00-53-2R-5W=1.0 O=.040 R=.032 L=5.0 D=SDR REXA2022070801507Angle · wornR/H MLG WHEEL WELL ANGLE HAS ONE EA OVERSIZED HOLE. REPLACED ANGLE PER CRJ200 SRM 51-42-06 AND PER DWG PL601R31058 REV J.SDR REXA2022062401338Intercostal · corrodedINTERCOSTAL AT STRINGER 20R IS CORRODED BETWEEN F.S.333 TO F.S.349 REMOVED AND REPLACED INTERCOSTAL IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR IPXA2022062283376None · damagedINSPECTION TYPE:A300FWD CARGO FLOOR PNL # 131 GE EDGE DAMAGE.REPAIR IAW SREO A300-5320-42722-FSDR IPXA2022062283375None · noneINSPECTION TYPE:A300FWD CARGO FLOOR PNL # 132GG BROKENREPAIR IAW SREO A300-5320-422722-FSDR IPXA2022062283374None · damagedINSPECTION TYPE:A300FWD CARGO PANEL 131 FE, EDGE DAMAGEREPAIR I.A.W SREO A300-5320-422722 FSDR SWAA2022072721332Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727C; BS 727C+2; BS 727C+6; BS 727C+10; BS 727C+14; BS 727C+18; BS 727D+3; BS 727D+7; BS 727D+10; BS 727D+14. / [01] ALL STEPS COMPLETED;[02] VERIFIED STEPS 1-8 ARE OUT OF LIMITS PER SRM 53-00-5SDR SWAA2022072721334Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 747+2; BS 747+6; BS 747+10; BS 747+14; BS 747+18. / [01] ALL STEPS COMPLETED 1 TO 5;[02] CORRECTED MEASUREMENT 19;[03] VERIFIED MEASUREMENT TABLE AND COMPLETED STEPS 1-5;[04] DUE TO OUT OF LIMITSDR SWAA2022072721333Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727D+18; BS 727E+2; BS 727E+6; BS 727E+9; BS 727E+10; BS 727E+14; BS 727E+15; BS 727E+18. / [01] ALL STEPS COMPLETED 1 TO 5;[02] VERIFIED STEPS 1-5 AND MEASUREMENT TABLE.;[03] CORRECTED MEASUREMSDR SWAA2022072721341Shield · corrodedCORROSION ON AFT CARGO BAY AFT DOOR SHIELD AT RBL 22 BS 847+8; BS 847+11; BS 847+15. / [01] VERIFIED APPLICABILITY PER SRM NOT ALLOWABLE DAMAGE THIS PARTS NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 0G-0 STEP 9C;[02] VERIFIED CORRECTSDR SWAA2022072721335Sidewall Support · corrodedCORROSION ON AFT CARGO BAY SIDEWALL SUPPORT AT RBL 23 BS 727C+19. / [01] VERIFIED APPLICABILITY PER SRM 53-00-53-1A-2<BR>REMOVED CORROSION ON AFT CARGO BAY SIDEWALL SUPPORT AT RBL23 BS 727C+19. REWORKED AREA L=5';W=1';D=0.006'. FOUND OUT OF LIMIT IAW SRM 53-00SDR SWAA2022072721337Attach Angle · corrodedCORROSION ON AFT CARGO BAY AFT BULKHEAD SUPPORT ATTACH ANGLE AT LBL 10 BS 847+19. / [01] VERIFIED APPLICABILITY PER SRM NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9C;[02] REMOVED ON AFT CSDR SWAA2022072721327Intercostal · corrodedCORROSION ON AFT CARGO BAY INTERCOSTAL AT RBL 19 BS 767+6. / [01] VERIFIED APPLICABILITY PER SRM 53-60-15-1A-1<BR>REMOVED CORROSION ON AFT CARGO BAY INTERCOSTAL RBL 19 BS 767+6. REWORKED AREA L=3';W=1.3';D=0.009' ORIGINAL THICKNESS 0.050'. FOUND TO BE OUT OF LSDR SWAA2022072721340Shield · corrodedCORROSION ON AFT CARGO BAY FWD DOOR SHIELD AT RBL 22 BS 767+2; BS 767+4; BS 767+12; BS 767+16. / [01] VERIFIED APPLICABILITY PER SRM NOT ALLOWABLE DAMAGE THIS PARTS NOT ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 0G-0 STEP 9C;[02] VERIFIED COSDR SWAA2022072721339Doubler · corrodedCORROSION ON AFT CARGO BAY TENSION STRAP ATTACH DOUBLER AT RBL 19 BS 787+13. / [01] VERIFIED APPLICABILITY PER SRM NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9C;[02] REMOVED ON AFT CARGO SDR SWAA2022072821326Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727+11; BS 727A+2; BS 727A+12; BS 727B+2; BS 727B+6; BS 727B+8; BS 727B+10; BS 727B+12; BS 727B+14; BS 727B+18. / [01] ALL STEPS COMPLETED;[02] VERIFIED STEPS 1-9 OUT OF LIMITS AND MEASUREMENT TSDR SWAA2022072821331Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 767+10; BS 767+14; BS 767+18; BS 787+2; BS 787+6; BS 787+10; BS 787+14; BS 827+14. / [01] VERIFIED APPLICABILITY AS PER SRM 53-00-53-1A-2;[02] VERIFIED STEPS 1-5 AND MEASUREMENT TABLE.;[03] FABRSDR SWAA2022072721315Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 440+10; BS 460+6; BS 460+10; BS 480+6. / [01] ALL MAINTENANCE ACTION ARE COMPLETED WITH CUSTOMER CARD#TTG8QOOD4TAW.REQUIRE FINAL BUY OFF.;[02] VERIFIED MEASUREMENT TABLE; CORRECTIVE ACTION 1. VESDR SWAA2022072721316Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 480+10; BS 480+14; BS 480+18; BS 500+5; BS 500+10; BS 500+14; BS 500+18; BS 500A+2; BS 500A+6; BS 500A+10. / [01] ALL MAINTENANCE ACTION ARE COMPLETED WITH CUSTOMER CARD#TTG8QOOD4TAW;REQUIRE FINSDR SWAA2022072721317Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500A+14; BS 500A+18; BS 500B+2; BS 500B+6; BS 500B+14; BS 500B+18; BS 500C+2. / ;FOUN TO BE OUT OF LIMITS IAW 53-00-53-1A-2 USED TOOL ID ATS 1672 S/N 65092939 DUE 03/2023 FABRICATED LOCATED AND SDR SWAA2022072721321Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500B+2; BS 500B+6; BS 500B+14; BS 500B+18; BS 500C+2; BS 500C+6; BS 500C+10. / [01] REMOVED CORROSION IN FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL24 BS500A TO BS500D;MEASURE:L=.6;W=.6;D=0.0SDR SWAA2022072721318Shield · corrodedCORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 24 BS 420+9; BS 420+16. / [01] PRIOR TO REMOVAL;FOUND PART TO HAVE NO ALLOWABLE DAMAGE OR SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 STEP 9.<BR><BR>REMOVED SHIELD AT RBL 24 BS 420 TO BSDR SWAA2022072721322Shield · corrodedCORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 500+2; BS 500+6; BS 500+10; BS 500+14. / [01] REMOVED CORROSION ON FWD CARGO BAY AFT SHIELD AT RBL24 BS492.4 TO BS500A;FOUND PART TO HAVE NO ALLOWABLE DAMAGE OR SRM LIMITS AND SO PART IS REPAIRABLE BY REPSDR SWAA2022072721324Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 907+10; BS 907+17. / [01] COMPLETED ALL STEPS;[02] VERIFIED PARTIAL ITEM STEPS 1 AND 2.;[03] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01 AND SOPM 20-41-02;[04] VERIFIED CORRESDR SWAA2022072721329Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727C+18; 727D+3; BS 727D+5; BS 727D+7; BS 727D+1; BS 727D+14; BS 727E+2; BS 727E+6; BS 727E+10. / [01] VERIFIED APPLICABILITY AS PER SRM 53-00-53-1A-2;[02] VERIFIED STEPS 1-6- OUT OF LIMITS.;[03SDR SWAA2022072721325Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727A+14; BS 727B+2; BS 727B+6; BS 727B+10; BS 727B+14; BS 727B+18; BS 727C+2; BS 727C+6; BS 727C+10; BS 727C+14. / [01] ALL STEPS COMPLETED;[02] VERIFIED STEPS 1-7;[03] CORRECTED MEASUREMENT 19;SDR SWAA2022072721330Sidewall Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727E+14; BS 727E+18; BS 747+2; BS 747+6; BS 747+10; BS 747+14; BS 747+18; BS 767+3; BS 767+6; BS 767+7. / [01] ALL STEPS COMPLETED;[02] VERIFIED STEP 1-6- SRM APPLICABILITY AND TO BE OUT OF LIMISDR SWAA2022072521239Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED ON UPPER FLANGE BS 360+15' RBL 9. CORRECT LOCATION BS 380+15' / [01] INSTALLED EWIS PROTECTION AT REPAIR AREA AS PER B-737-700 AMM. 20-60-07-913-801;[02] REMOVED DAMAGE CABIN FLOOR INTERCOSTAL UPPER FLANGE AT STA.360+15'AS PER BSDR SWAA2022072521240Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED ON UPPER FLANGE BS 360+19' BL 0 CORRECT LOCATION IS BS 380+19' / [01] INSTALLED EWIS PROTECTION AT REPAIR AREA AS PER B-737-700 AMM. 20-60-07-913-801;[02] REMOVED DAMAGE CABIN FLOOR INTERCOSTAL UPPER FLANGE AT STA.360+19 BL.0 ASSDR SWAA2022072521243Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED ON UPPER FLANGE BS 360+10' RBL 41. 8-49 CORRECTION FOR LOCATION: BS 380+10' RBL 41 / [01] INSTALLED EWIS PROTECTION AT REPAIR AREA AS PER B-737-700 AMM. 20-60-07-913-801;[02] REMOVED DAMAGE CABIN FLOOR INTERCOSTAL UPPER FLANGE ASDR SWAA2022072521241Fastener · missingCABIN FLOOR INTERCOSTAL FWD SIDE OF BS 380 BL 0 MISSING 5 FASTENERS. 8-52 CORRECT LOCATION IS: BS 400. / [01] CORRECTING STA : STATION IS 380 TO 400;[02] STEP 1 CORRECT LOCATION IS STA 400; BL 0.;[03] INSTALLED MISSING FASTENERS AT CABIN FLOOR INTERCOSTAL FWD.SDR R61A2022071400431Shear Tie · corrodedSHEAR CLIP CORRODED AT FR. 87 STR. 27R-26R. REMOVED AND REPLACED SHEAR CLIP AT FR. 87 STR. 27R-26R REF EMB SRM 51-40-08SDR REXA2022070101449Stringer · corrodedSTRINGER 25L BETWEEN FS 485.00 AND FS 517.00 IS CORRODED REPAIRED STRINGER IAW ENDEAVOR EA CRJ953-13740 REV A DATED 6/24/2022.SDR REXA2022062401385Beam · corrodedFLOOR BEAM AT LBL9.00 HAS CORROSION BETWEEN FS661+24 AND 661+90. REPAIRED FLOOR BEAM PER CRJ900 SRM 53-00-43-201-001-A03 AND REO 690-53-31-651 REV -- DATED 2022-06-20SDR DALA2022062404431Stringer · corrodedSHIP 686 CORROSION ON SUPPORT STA 1380-1440 STRG 27R AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00289: SUPPORT STA 1380-1440 STRG 27R AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-200, SRM. (2287372)SDR REXA2022062401339Doubler · corrodedANTENNA DOUBLER CORRODED AT STGR 27 BETWEEN FS 485.00 AND FS 501.00 REMOVED AND REPLACED DOUBLER (NUT PLATE SUB ASSEMBLY) I.A.W. CRJ 900 SRM'S #51-40-11-001-001-A01 AND51-42-06-0001-001-A01SDR FDEA202206211488Angle · crackedAREA AFT OF BULK CARGO COMPARTMENT L/H SIDE JUST BELOW MAIN CABIN FLOOR LEVEL, FLOOR SUPPORT STRUVTURE HAS 1EA INBD FACING SPLICE CRACKED REMOVED & REPLACED ANGLE IAW BAC DWG 146T5650, SHEET 5, REV CSDR FDEA202206211487Angle · crackedAREA AFT OF THE BULK CARGO COMPARTMENT L/H SIDE JUST BELOW THE MAIN CABIN FLOOR LEVEL, FLOOR SUPPORT STRUCTURE HAS 1EA OTBD FACING SPLICE CRACKED REMOVED & REPLACED ANGLE IAW BAC DWG 146T5650, SHEET 5, REV CSDR FDEA202206211486Angle · crackedAREA AFT OF THE BULK CARGO COMPARTMENT R/H SIDE JUST BELOW THE MAIN CABIN FLOOR LEVEL, FLOOR SUPPORT STRUCTURE HAS 1EA INBD FACING SPLICE CRACKED REMOVED & REPLACED ANGLE IAW BAC DWG 146T5650, SHEET 5, REV C
Back to JASC 5320