JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021081372700Floor Support · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON INTERCOSTAL(P/N:146T5649-8)ON MAIN DECK FLOOR NEAR STA 1602.64, RBL 54.75.INSTALL NEW PART I.A.W BOEING DWG 146T5650 SH 4, REV"A"; SH 5, REV"C" AND 767-300F SRM 51-40-02 REV 80.03.SDR IPXA2021081372699Angle · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON ANGLE (P/N:146T5628-22) ON MAIN DECK FLOOR BETWEEN STA 1581.845 AND STA 1597.940, RBL 33.INSTALL NEW PART I.A.W. BOEING DWG 146T5650 SH 2, REV "A", AND 767-300F SRM 51-40-02 REV 80.03SDR IPXA2021081372698Intercostal · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON INTERCOSTAL(P/N:146T5649-3) ON MAIN DECK FLOOR NEAR STA 1597.04, BETWEEN RBL 11 AND RBL 33.INSTALL NEW I.A.W BOEING DWG 146T5650 SH 2, REV"A" AND 767-300F SRM 51-40-02 REV 80.03.SDR IPXA2021081372697Filler · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON FILLER (P/N:146T5609-67) ON MAIN DECK FLOOR NEAR STA 1601,LBL 60.INSTALL NEW PART I.A.W BOEING DWG 146T5650 SH 5, REV "C" AND 767-300F SRM 51-40-02 REV 80.03.SDR IPXA2021081372696Angle · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON CLIP(P/N:146T5619-357) ON MAIN DECK FLOOR NEAR STA 1586.51, LBL 54.75.INSTALL NEW PART I.A.W BOEING DWG 146T5650 SH 4, REV"A" AND 767-300F SRM 51-40-02 REV 80.03SDR IPXA2021081372695Intercostal · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON INTERCOSTAL (P/N;146T5649-7) ON MAIN DECK FLOOR NEAR STA 1602.64, LBL 54.75.INSTALL NEW PART I.A.W BOEING DWG 146T5650 SH 4, REV "A";SH 5,REV"C" AND 767-300F SRM 51-40-02 REV 80.03SDR IPXA2021081372693Channel · corrodedINSPECTION TYPE:C12CORROSION WAS FOUND ON MOPSILL(P/N:146T5651-15) ON MAIN DECK CARGO FLOOR STRUCTURE AT STA 1605, LBL54.INSTALL NEW PART I.A.W BOEING DWG 146T5650 SH5,REV"C" AND 767-300F SRM 51-40-02 REV 80.03SDR DALA2021080904540Floor Support · corrodedSHIP 650 CORROSION ON STGR LBL 7.55 BTW STA 1380/1440. CORRECTIVE ACTION: SUMMARY: OF NRC 00596 STGR LBL 7.55 BTW STA 1380 TO 1440 WAS REPLACED PER B757-200 SRM. (1900638)SDR DALA2021080904539Floor Support · corrodedSHIP 650 CORROSION ON STRINGER LBL 2.90 BTW STA 1360/1380. CORRECTIVE ACTION: SUMMARY: OF NRC 00516 STRINGER LBL 2.90 BTW STA 1360/1380 (C2) WAS REPAIRED PER B757-200 SRM. (1900494)SDR DALA2021080904536Floor Support · corrodedSHIP 650 CORROSION ON STR LBL 10.45 BETWEEN STA 740/760 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: STR LBL 10.45 BETWEEN STA 705/800 WAS REPAIRED PER B757-200 SRM. (1900389)SDR DALA2021080904535Floor Support · corrodedSHIP 650 CORROSION ON STRINGER LBL 11.40 BTW STA 1620 TO 1640 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00571: CORROSION LEVEL, STRINGER LBL 11.40 BTW STA 1610 TO 1640 WAS REPAIRED PER B757-200 SRM. (1900385)SDR DALA2021080904530Floor Support · corrodedSHIP 650 CORROSION ON STRINGER LBL 7.55 BTW STA 1500 TO 1540 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00563: SECTION OF STRINGER LBL 7.55 BTW STA 1500 TO 1550 WAS REPAIRED PER B757-200 SRM. (1900020)SDR DALA2021080904527Floor Support · corrodedSHIP 650 CORROSION ON STRINGER LBL 2.90 BTW STA 1440+03 TO 1500 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SECTION OF STRINGER LBL 2.90 BTW STA 1440+03 TO 1500 AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-200 SRM. (1899992)SDR DALA2021080904526Floor Support · corrodedSHIP 650 CORROSION ON STRINGER LBL 7.55 BTW STA 1440+ 03 TO 1500 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00445: SECTION OF STRINGER LBL 7.55 BTW STA 1440+03 TO 1500 AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-200 SRM. (1899897)SDR AALA202108092465Support Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN UPPER SUPPORT ANGLE OUTBD OF KEEL BEAM AT STA 663.75 AND RBL 13, MEASURING L=0.5 IN, W=0.001 IN, D=0.071 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 57-10-10 AND EA 329337.SDR DALA2021080604472Stiffener · crackedSHIP 3158 - CRACK INDICATION FOUND ON FRAME 4 LH VERTICAL STIFFENER. CORRECTIVE ACTION: PERFORMED VERTICAL STIFFENER REWORK ON FRAME 4 LH PER AMDS CARD 5311 (1900785)SDR REXA2021100500776Seat Track · gougedSEAT TRACK GOUGE AT STA 661+8.40 WL 72.50 I/B TRACK (RED DOT) R/H INSIDE. JC:900-53-900-126 IN:RR EMP#:1092 REMOVED AND REPLACED SEAL TRACK F.S. 661.00 +8.40 TO F.S. 693.00 IAW CRJ 900 SRM 51-41-02.SDR REXA2021100500775Frame · corrodedCORROSION ON LOWER FLANGE AT FRAME FS319.7 BETWEEN STGR 26L TO STGR27 JC: 900-53-140-500 IN:AV EMP#: 873 CORROSION ON LOWER FLANGE @ F.S. 319.7 BETWEEN STGR 26L TO 27L REPAIRED IAW EA CRJ953-12029.SDR REXA2021100500774Frame · corrodedCORROSION ON LOWER FLANGE AT FRAME FS310 BETWEEN STGR25L TO STGR26L JC:900-53-14-500 IN:AV EMP#:873 REMOVED CORROSION ON LOWER FLANGE AT FRAME 310 BTW STGR25L TO STGR26L FOUND -002" MATERIAL LOST-REF TO EA #CRJ953-11999SDR REXA2021100500773Stringer · corrodedCORROSION ON STGR 26L FS 280+5 JC:900-53-140-500 IN:AV EMP#:873 REMOVED CORROSION ON STGR 26L FS280. FOUND TO BE OUT OF LIMITS IAW CRJ900 SRM 53-21-06. REMOVED & REPLACED NEW STGR IAW CRJ 900 SRM 51-40-11 & 51-42-06SDR REXA2021100500772Buttstrap · corrodedCORROSION ON BUTTSTRAP AT FS 280 BETWEEN STGR 25L TO STGR 26L JC:900-53-140-500 IN:AV EMP#:873 REPAIRED BUTTSTRAP AT F.S. 280 BETWEEN STGR 25L TO STGR 26L IAW ENDEAVOR AIR CRJ900 EA NO: CRJ953-12172 EA REV IRSDR REXA2021100500771Buttstrap · corroded"CORROSION ON BUTTSTRAP AT FS 280 BETWEEN STGR 24L TO STGR 25L JC:900-53-140-500 IN:AV EMP#:873 REPAIRED BUTTSTRAP AT F.S. 280 BETWEEN STGR 24L TO STGR 25L IAW ENDEAVOR AIR CRJ900 EA NO: CRJ953-12173 EA REV I RSDR REXA2021100500770Angle · corrodedCORROSION ON NUTPLATES AT FS 280 CRAWLWAY ANGLE SUPPORT JC: 900-53-140-500 IN:AV EMP#:873 REMOVED & REPLACED FWD CRAWLWAY ANGLE SUPPORT P/N: CC670-34095-3 IAW CRJ900 SRM'S 51-40-11, 51-43-06 & 51-42-13SDR SWAA2021092003666Support Angle · crackedCRACK SUPPORT ANGLE LOCATED AT BS 695 AND BL 0 FWD FACE AT PASSENGER CABIN ; 2021-357046 / [01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 21-JAN-22; [02] REPLACED SUPPORT ANGLE LOCATED AT BS 695 AND BL 0 FWD FACE AT PASSENGERSDR SWAA2021092003667Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS 695 AND BL 0 AFT FACE AT PASSENGER CABIN ; 2021-357056 / [01] INSTALLED REPAIR SUPPORT ANGLE LOCATED BS 695 AND BL 0 AFT FACE AT PASSENGER IAW B737-700 SRM 51-40-02 AND DRAWING 273A9112 REV:H; [02] REPLACED REPAIR SUPPORT ANGLE LSDR SWAA2021092003668Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS 695 AND LBL 24 LOWER POSITION AT PASSENGER CABIN ; 2021-357068 / [01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 21-JAN-22; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DASDR SWAA2021091503706Strap · corrodedCORROSION ON TENSION STRAP AT AFT WET AREA BS1018 LBL3 WL208. ; / [01] REMOVED AND EVALUATED CORROSION REMOVAL AT DISCREPANCY AREA. L= 2.8' W=1.2' DEPTH= 0.015'. NO ALLOWABLE DAMAGE FOUND ON SRM. PART TO BE REPAIR BY REPLACEMENT PER SRM 51-10-02 DEPTH GAGE ID SDR SWAA2021091414454Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BS 663.5 AT BL0 TO LBL 64 AND WL 173.1 AIR CONDITION COMPARTMENT ; 2021-342346 / [01] TOOL USED CALIPER P/N 700-113-10 S/N 0019306 DUE DATE 14-OCT-21; [02] REPLACED ANGLE LOCATED BS 663.5 AT BL0 TO LBL 64 AND WL 173.1 AIR CONDITISDR SWAA2021091003801Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS 695 AND BL0 RH SIDE AT PASSENGER CABIN ; 2021-368562 / [01] REMOVED SUPPORT ANGLE LOC. BS 695 AND BL0 RH SIDE AT PASSENGER CABIN IAW SRM B737-700 SRM-51-40-02 DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM B737-700; ANGLE MUST BE REPLASDR SWAA2021090703341Angle · corrodedR2 DOOR LOWER SILL ANGLE;BETWEEN STA967 AND STA.986.5 CORRORED/ ; / [01] REMOVED CORROSION AT R2 DOOR SILL ANGLE BETWEEN STA967 AND STA986.5AS PER REF B737 SRM 51-10-02-; [02] VERIFIED STEP 1.; [03] PERFORMED UT THICKNESS INSP ON REWORKED AREA AT R2 DOOR LOWERSDR SWAA2021090703842Panel · delaminatedPANEL 193AR DELAMINATED ON OUTER SURFACE; 7' FROM FWD EDGE; 31.25' FROM I/B EDGE. ; / [01] PART/MATERIAL IDENTIFIED PER SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM 18 . <BR>PREVIOUS REPAIR FAILED ; DAMAGE EXCEEDS THE ALLOWABLE LIMITS AS GIVEN IN SRM 53-40-70-1A-1 PARSDR SWAA2021090703338Splice Strap · corrodedAFT CARGO FLOOR SPLICE STRAP AT STA.727 D +5 ;CORRORED ; / [01] REMOVED CORROSION AT AFT CARGO FLOOR SPLICE STRAP AT STA 727D+5 AS PER REF B737 SRM 51-10-02-0G-0 FOUND EXFOLIATE CORROSION AS PER REF B737SRM53-00-53-1A-2; [02] VERIFIED STEP 1.; [03] RECIVED NEWSDR SWAA2021090703340Splice · corrodedAFT CARGO ;FLOOR SPLICE STRAP AT STA 767 +5 CORRORED ; / [01] REMOVED CORROSION AT AFT CARGO FLOOR SPLICE STRAP AT STA767+5 AS PER REF B737SRM51-10-02-0G-0 FOUND EXFOLIATE CORROSLON; [02] VERIFIED STEP 1.; [03] RECEIVED NEW STRAP P/N: 146A9401-4 AND INSTALLATISDR SWAA2021082303971Gusset · crackedFOUND A GUSSET CRACKED AT FWD. CARGO COMPT. AFT. BLKH. AREA; STA. 540D; STRG. 19R. ; / [01] REMOVED DAMAGE GUSSET AT FWD CARGO COMPT AFT BLKH STA 540D S-19R;PER B737-7 SRM 51-4-02-0G-0.; [02] VERIFIED STEP 1; [03] OK TO INSTALL GUSSET AT FWD. CARGO AFT BULKHEASDR SWAA2021082304027Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500C FWD SIDE LBL25 WL155. ; / [01] REMOVED INTERCOSTAL ATTACH ANGLE AT FCB BS 500C FWD SIDE LBL25 WL 155 IAW SRM 51-40-02; [02] LOCATED AND DRILLED NEW ATTACH ANGLE PER SRM 51-40-05 AND DWG 143A7505 SH 118. SDR SWAA2021082304039Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS769 TO BS783 RBL22 WL157. ; / [01] THERE IS NO SRM ALLOWABLE DAMAGE FOR FWD SHIELD AT ACB RBL22. PART TO BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0; [02] THERE IS NO SRM ALLOWABLE DAMAGE FOR FWD SHIELD AT ACB RBSDR SWAA2021082304015Shield · corrodedCORROSION ON AFT SHIELD AT FWD CARGO BAY BS497 RBL24 WL157. ; / [01] REMOVED CORROSION ON AFT SHIELD AT FWD CARGO BAY BS 497; RBL 24; WL 157; WORK AREA 0.600' L X 0.600' W X 0.010' DEPTH ; NO ALLOWABLE DAMAGE ON SRM; [02] REMOVED CORROSION ON AFT SHIELD AT FWDSDR SWAA2021082304014Support Angle · corrodedCORROSION AT FWD CARGO BAY ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS500D LBL18 TO RBL20 WL157. ; / [01] NO ALLOWABLE DAMAGE LIMTOS FOUND IN SRM FOR FCB AFT CENTER BULKHEAD SUPPORT; PART TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02; [02] UPDATED MEASUREMENTS;SDR SWAA2021082304059Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727C+6.5 LBL22 WL156. ; / [01] REMOVED CORROSION 1'X1'X0.005' AT ACB BS 727C+6.5 LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] VERIFIED RESDR SWAA2021082304043Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727D+5 RBL22 WL156. ; / [01] REMOVED CORROSION FROM ACB RH FLOOR TO SIDEWALL SUPPORT AT BS 727D+5' MEASURED 4.6'L X 2.5' AND 0.015' DEEP; ORIGINAL THIKNESS OF 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53SDR SWAA2021082304049Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS803 TO BS816 RBL26 WL158. ; / [01] REMOVED CORROSION ON ACB SUBTHRESHOLD AT BS 803 - BS816 RBL 26 WL 158 IN 5 EA. AREAS MAX DIMENSION OF 2.5'L X 1.5'W X 0.010' DEEP. ORIGINAL THICKNESS .045'; REMAINING THICKNESSSDR SWAA2021082304051Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS807 LBL22 WL158. ; / [01] REMOVED CORROSION 1'X1'X0.005' AT ACB BS 807 LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] VERIFIED REMOVED CORRSDR SWAA2021082304055Floor Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS792 LBL22 WL157. ; / [01] REMOVED CORROSION 1'X1'X0.005' AT ACB BS 792 LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] VERIFIED REMOVED CORRSDR SWAA2021082304056Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727E - BS761 LBL22 WL156. ; / [01] REMOVED CORROSION 1'X1'X0.006' AT ACB BS 747+14' LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] VERIFIEDSDR SWAA2021082304050Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS826 RBL26 WL159. ; / [01] REMOVED CORROSION ON ACB SUBTHRESHOLD AT BS 826 RBL 26 WL 159 IN AREA OF 1.5'L X 1'W X 0.008' DEEP. ORIGINAL THICKNESS .045'; REMAINING THICKNESS .037' FOUND TO BE OUT OF LIMITS IAW <BRSDR SWAA2021082303559Filler · brokenEXTERNAL POWER RECEPTACLE DOOR CUT OUT LOWER REPAIR FILLER FILLER IS BROKEN. ; / [01] REMOVED DOUBLER ITEM[2]; & FILLER ITEM[3] TO BE REPLACED; AT EXT. POWER RECEPTACLE DOOR CUT OUT LOWER AREA;PER REF. B737-7 SRM 51-40-02-0G-0; & 53-10-15-2R-4 REPAIR 4 FIG. 20SDR SWAA2021082304016Support Bracket · crackedPNEUMATIC DUCT CLAMP SUPPORT BRACKET IS CRACKED AT B.S. 540+6; W.L. 160; R.B.L. 8. ; / [01] REMOVED AND INSTALLED NEW PNEUMATIC DUCT CLAMP SUPPORT BRACKET AT BS 540+6 WL 160 RBL 8 IAW SRM 51-40-02-0G STEP 7; [02] VERIFIED; [03] REJECTION: TABLE MEASUREMENTS MASDR SWAA2021082304028Support Bracket · crackedPNEUMATIC DUCT CLAMP SUPPORT BRACKET IS CRACKED AT B.S. 540+2; W.L. 160; L.B.L. 8. ; / [01] REMOVED AND INSTALLED NEW PNEUMATIC DUCT CLAMP SUPPORT BRACKET AT BS 540+2 WL 160 LBL 8 IAW SRM 51-40-02-0G STEP 7; [02] UPDATED MEASUREMENT CHART; [03] VERIFIED; [04] SDR DALA2021080904525Floor Support · corrodedSHIP 650 CORROSION ON STRINGER RBL 2.90 BTW STA 1300/1340 + 3. CORRECTIVE ACTION: SUMMARY OF NRC 00498: CORROSION LEVEL SECTION DAMAGED ON STRINGER RBL 2.90 BTW STA 1300/1340 + 3 WAS REPAIRED PER B757-200 SRM. (1899562)SDR DALA2021080904523Floor Support · corrodedSHIP 650 CORROSION ON STRINGER RBL 10.45 BTW STA 1300 /1340 + 3. CORRECTIVE ACTION: SUMMARY OF NRC 00494: CORROSION LEVEL SECTION DAMAGED ON STRINGER RBL 10.45 BTW STA 1290 TO 1340 WAS REPAIRED PER B757-200 SRM. (1899428)
Back to JASC 5320