JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023062048266Floor Panel · pulledFLOOR PANEL 241FF UPPER SURFACE HAS PULLED STRANDS.<[01] DUE TO EXTENT OF THE DAMAGE FABRICATED NEW FLOOR PANEL 241FF FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED ALL INSERTS USING BMS5-107 LOT# AK2KP8383K-1; CURED INSERTS USING HEAT LAMP AND THERMSDR SWAA2023062048268Floor Panel · pulledFLOOR PANEL 242CF UPPER SURFACE HAS PULLED STRANDS.<[01] PART/MATERIAL IDENTIFIED PER SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 SECTION 44. <BR>UPPER SURFACE DAMAGE EXCEEDS THE ALLOWABLE LIMITS AS GIVEN IN SRM 53-00-50-1A-1 PARA 4 SECTION. 44.<BR>DAMAGED FLOOR PANEL SDR SWAA2023062048274Floor Panel · pulledFLOOR PANEL 241EF UPPER SURFACE HAS PULLED STRANDS.<[01] DUE TO EXTENT OF THE DAMAGE FABRICATED NEW FLOOR PANEL 241EF FROM BMS4-17 TYPE 6 LOT#1526676-1; LOCATED AND INSTALLED ALL INSERTS USING BMS5-107 LOT# AK2KP8383K-1; CURED INSERTS USING HEAT LAMP AND THERMSDR SWAA2023062048265Floor Panel · pulledFLOOR PANEL 241DF UPPER SURFACE HAS PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 241DF USING BMS 4-17TY6 LOT#1526676-2; INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K; CURED WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023; PART MASDR SWAA2023062048267Floor Panel · pulledFLOOR PANEL 242AF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 SHEET 1; FIGURE 4; TABLE 4; AND DWG DOC: 144A5810 ID: 0189<BR><BR>PANEL UPPER SURFACE DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM <BR>53-00-50-1A-1 PAR.SDR SWAA2023062048273Floor Panel · pulledFLOOR PANEL 241CF UPPER SURFACE HAS PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 241CF USING BMS 4-17TY6 LOT#1526676-2; INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K; CURED WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023 AND PARTSDR SWAA2023062048261Floor Panel · pulledFLOOR PANEL 241XF UPPER SURFACE HAS PULLED STRANDS. PANEL SHOULD BE 231XF DUE TO THE FAULT DETAILS ON THIS DEFECT MENTIONING THE OPEN OF PANEL 231XF.<[01] IDENTIFIED FLOOR PANEL 231XF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 AND BAC DWG 144A5810 ID: 012SDR SWAA2023062048262Floor Panel · pulledFLOOR PANEL 231ZF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 231ZF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 AND BAC DWG 144A5810 ID: 0160. DAMAGE TO UPPER SURFACE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. FLSDR SWAA2023062048271Floor Panel · pulledFLOOR PANEL 232RF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 232RF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. DAMAGE TO FLOOR PANEL IS BEYOND ECONOMICAL REPAIRSDR SWAA2023062048263Floor Panel · pulledFLOOR PANEL 232SF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 232SF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. DAMAGE TO FLOOR PANEL IS BEYOND ECONOMICAL REPAIRSDR SWAA2023062048264Floor Panel · pulledFLOOR PANEL 241AF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 241AF MATERIAL IAW SRM 53-00-50-0I-1 FIG 4 AND TABLE 4.<BR><BR>DAMAGE TO PANEL 241BF IS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F. AND BEYOND ECONOMICAL REPAIR.<BR><BR>NEW SDR SWAA2023062048272Floor Panel · pulledFLOOR PANEL 241BF UPPER SURFACE HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 241BF MATERIAL IAW SRM 53-00-50-0I-1 FIG 4 AND TABLE 4.<BR><BR>DAMAGE TO PANEL 241BF IS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F. AND BEYOND ECONOMICAL REPAIR.<BR><BR>NEW SDR ASAA2023051343408Floorboard · delaminatedMAIN CABIN FLOOR BOARD 222EF UPPER SKIN IS DELAMINATED. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR ON MAIN CABIN FLOOR BOARD 222EF IAW A321 SRM 53-02-00-283-001, REV. 144 TABLE 3.SDR UIEA2023051200453Floor Panel · dentedBULK CARGO RH STA 1920 - 2040 FLOOR PANEL FOUND 3EA DENT AND 1EA PUNCTURE(<P>3EA DENT AND 1EA PUNCTURE AREA REPAIRED AS PER RI NO : RI-53-60-16248 REV A</P>)SDR UIEA2023051200454Floor Panel · dentedBULK CARGO STA 2040-2160 CTR FLOOR PANEL FOUND 3EA DENT(<P>3EA DENT AREA REPAIRED AS PER RI NO : RI-53-60-16249 REV A</P>)SDR UIEA2023051200455Floor Panel · puncturedBULK CARGO STA 1920-2040 CTR FLOOR PANLE FOUND 3EA DENT AND 2EA PUNCTURE(<P>3EA DENT AND 2EA PUNCTURE AREA REPAIRED AS PER RI NO : RI-53-60-16250 REV A</P>)SDR UIEA2023051200456Floor Panel · dentedBULK CARGO LH STA 1920-2040 FLOOR PANEL FOUND 3EA LOCATIONS DENT(<P>3EA LOCATION DENT AREA REPAIRED AS PER RI NO. RI-53-60-16251 REV A</P>)SDR SWAA2023061448330Floor Panel · frayedMAIN CABIN FLOOR PANEL 241AEF UPPER SURFACE FRAYING AND COMPOSITE EXPOSED<[01] RECEIVED MAIN CABIN FLOOR PANELS 241AEF; PANEL WILL BE INSTALLED ON T/C TTG8Q00K86F1;[02] VERIFIED STEP 1SDR SWAA2023061347797Floor Panel · crackedL/H CABIN FLOOR PANEL 231EF UPPER SKIN SURFACE CRACKED.<[01] REPAIRED FLOOR PANEL #231EF PER B737 SRM 53-00-50-2R-1. MATERIALS USED RESIN P/O#1799598; CLOTH P/O#1738579;[02] RII....VERIFIED FINAL CORRECTIVE ACTION.SDR SWAA2023061347796Floor Panel · chippedL/H CABIN FLOOR PANEL 231EF UPPER SKIN SURFACE CHIPPED.<[01] WORK ACCOMLPISHED ON NON-ROUTINE TTGQ00KZSMW;[02] REPAIRED DAMAGE AREA AS MARKED ON TOP SURFACE OF MAIN CABIN FLOOR PANEL 231EF ASPER B737 SRM 53-00-50-2R-1. MATERIALS USED PO#1738579; AND PO#1799598SDR SWAA2023061347799Floor Panel · damagedL/H CABIN FLOOR PANEL 231LF UPPER SKIN SURFACE O/B SIDE SMASHED.<[01] REPAIRED FLOOR PANEL #231LF PER B737 SRM 53-00-50-2R-1. MATERIALS USED RESIN P/O#1799598; CLOTH P/O#1738579;[02] CWSDR ASAA2023051243277Insert · damagedMID CABIN FLOOR BOARD P/N 144A5810-124 INSERT MISSING DAMAGE. GROUNDED - YES. REPAIRED MID CABIN FLOOR BOARD P/N 144A5810-124 INSERT MISSING DAMAGE IAW ASA B737-800 RM 53-00-50-0I-1 & 53-00-50-2R-2 REP 2 *SDR DALA2023051603915Unknown · unknownSHIP 660 BROKEN STABILIZATION STRAP BTW STA 365 TO STA 377 LBL 24 AT PAX CABIN FLOOR. CORRECTIVE ACTION: SUMMARY OF NRC 00631: STABILIZATION STRAP BTW STA 365 TO STA 377 LBL 24 WAS REPAIRED PER B-757-200 SRM. (2764363)SDR DALA2023051603914Unknown · unknownSHIP 672 CORROSION ON FLOOR SUPPORT RBL 16.10, RBL 7.55 AND RBL 2.90 BTW STA 635-705 AND RBL 10.45 BTW STA 640-680 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00534: FLOOR SUPPORT RBL 16.10 , RBL 7.55 AND RBL 2.90 BTW STA 635-705 AND RBL 10.45 SDR DALA2023051603912Unknown · unknownSHIP 688 CORROSION ON STRAP ANGLE BTW STA 740 AND 690 LBL 65 AT W2 AREA. CORRECTIVE ACTION: SUMMARY NRC 00422: CORROSION ON STRAP ANGLE BTW STA 740 AND 690 LBL 65 AT W2 AREA WAS REMOVED PER B757-200 SRM THEREFORE, AREAS ARE OUT LIMITS. B757-200 SRM, STRAP ANGLSDR DALA2023051603911Unknown · unknownSHIP 660 CORROSION OUT OF LIMITS ON BOX BEAM BTW STA 324 TO STA 365 RBL 63 AT PAX CABIN IN REF NRC 00596. CORRECTIVE ACTION: SUMMARY OF NRC 00738: CORROSION LEVEL 2; NEW BOX BEAM (2EA) AT RBL 63 BTW STA 324 TO STA 365 WERE REPLACED PER B-757-200 SRM. (2762864)SDR SWAA2023051548022Floor Panel · crackedRAMP REPORTS AFT CARGO FLOOR PANEL 140 BF HAS A CRACK.<[01] INSPECTED AND FOUND CRACK TO BE MORE THAN 2 INCHES FROM EDGE. REPAIRED CRACK ON FLOOR PANEL IN REFERENCE TO AMM 25-52-01. OK FOR CONTINUED SERVICE.SDR CALA2023051501508Floor Panel · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 232NF HAS CRUSHED CORNER. TRANSCRIBED FROM HAECO GSO NRC# 9286720SDR DALA2023051203749Unknown · unknownCRACK ON PAN (FASTENER HOLE AREA) ABOVE SEAL RETEINER AT AFT CARGO DOOR. SUMMARY OF NRC-00071: PAN ON 3 AREAS AT AFT CARGO COMPARTMENT DOOR WAS REPAIRED PER ERA 608442-14, REV ORIGINAL, SECTION I AND PRI 608442-4, REV 1. (LP #2763196)SDR SWAA2023061547768Floor Panel · deterioratedPAX CABIN BODY STA 747 HONEYCOMB PANEL #241RF IS SHOWING DISBANDING.<[01] REMOVED CABIN FLOOR PANEL 241RF AS PER BOEING 737-700 AMM 53-21-00-000-801;[02] VERIFIED PANEL IS REMOVED.;[03] FABRICATED NEW PANEL #241RF REF DWG#146A5810.;[04] VERIFIED STEP 1; 2 AND SDR SWAA2023061447914Floor Panel · frayedMAIN CABIN FLOOR PANEL 222CF UPPER SURFACE FRAYING<[01] APPLIED REPAIR ON MAIN CABIN FLOOR PANEL 222CF; AS PER B737 SRM 53-00-50-2R-2 MATERIAL USED PO.1473815 AND PO.1783720;[02] VERIFIED STEP 1SDR SWAA2023061447909Floor Panel · frayedMAIN CABIN FLOOR PANEL 222AF UPPER SURFACE FRAYING<[01] RECEIVED MAIN CABIN FLOOR PANELS 222AF PANEL WILL BE INSTALLED ON T/C TTG8Q00K86CC;[02] VERIFIED STEP 1.SDR SWAA2023061447907Floor Panel · frayedMAIN CABIN FLOOR PANEL 222DF UPPER SURFACE FRAYING<[01] REPAIRED WITH A PERMANENT REPAIR DAMAGE AREAS AS MARKED ON TOP SURFACE OF MAIN CABIN FLOOR PANEL 222DF AS PER B737 SRM 53-00-50-2R-1. MATERIALS USED PO#1738579 AND PO#1783720;[02] PERFORMED TAP TEST ON RESDR DALA2023051603894Unknown · unknownSHIP 1701 THE FWD CARGO AROUND DRAIN MARST FITTING FOUND CORROSION AT STA 654+121 TO 676, S-34L TO S-35L, CORRECTIVE ACTION: DAMAGED AREA REPAIRED PER B767-300 SRM 51- 40-02 (2764663)SDR SWAA2023051547654Floor Panel · crackedGROUND CREW REPORTS CRACK ON THE FLOOR OF THE FWD CARGO COMPARTMENT<[01] OK TO CONTINUE PER MEL 25-16-01 SP1B;[02] REPAIRED FWD CARGO COMPARTMENT FLOOR PANEL PER AMM 25-52-01.SDR DALA2023051503822Unknown · unknownSHIP 688 CORROSION ON LAVATORIES FITTING SUPPORTS STA 1640 RBL 24, RBL 45 AND LBL 45 AT W4 AREA. CORRECTIVE ACTION: SUMMARY OF NRC 000445 LAVATORIES FITTING SUPPORTS STA 1640 RBL 24, RBL 45 AND LBL 45 AT W4 AREA WERE REPLACED PER B757-200 SRM. (2762364)SDR DALA2023051503821Unknown · unknownSHIP 688 IN REF. NRC 0438: CORROSION ON BEAM BOX BTW STA 1661 AND 1681 LBL 53 AT W4. CORRECTIVE ACTION: SUMMARY NRC 00575: CORROSION ON BEAM BOX BTW STA 1661 AND 1681 LBL 53 AT W4 AREA WAS REMOVED PER B757-200 SRM AREAS ARE OUT LIMITS PER. B757-200 SRM BEAM BOSDR DALA2023051503820Unknown · unknownSHIP 672 SECONDARY NRC: IN REFERENCE TO NRC 00470: AFTER REMOVAL OF CORROSION ON FLOOR SUPPORT LBL2.90 BETWEEN STA 640 TO 700 FWD CARGO COMPARTMEN AREAS WERE MEASURED AND WAS FOUND OUT LIMITS. CORRECTIVE ACTION: SUMMARY OF NRC 00792: SECTION OF FLOOR SUPPORT LSDR DALA2023051503819Unknown · unknownSHIP 660 CRACK ON STABILIZATION STRAP RBL 25 AT BSTA 740.C1. CORRECTIVE ACTION: SUMMARY OF NRC 00179: STABILIZATION STRAP RBL 25 AT BSTA 740 WAS REPAIRED PER B757-200 SRM. (2761354)SDR CALA2023051201477Floor Support · damagedSUPPORT TASK: FLOOR PANEL 242MF HAS 1 SMALL HOLE IN UPPER SURFA CE. TRANSCRIBED FROM HAECO GSO NRC# 9286717SDR DALA2023053104361Unknown · unknownSHIP 3570 FOUND AFT CARGO FLOOR PANEL WITH SEVERAL AREA WITH SEQUECE OUT. CORRECTIVE ACTION: AFT CARGO COMPARTMENT SAID ABOVE AFFECTED AREAS WITH SEAL SQUEEZED OUT AT FLOOR PANELS BEEN REPAIRED WITH GLASS CLOTH TAPE IAW ASR A350-A-53-02-XX-18001-662A. (2760185SDR DALA2023053104360Unknown · unknownSHIP 3570 FOUND FWD CARGO FLOOR PANEL WITH SEVERAL AREA WITH SEAL SQUEEZE OUT. CORRECTIVE ACTION: FWD CARGO COMPARTMENT SAID ABOVE AFFECTED AREAS WITH SEAL SQUUEZED OUT AT FLOOR PANELS BEEN REPAIRED WITH GLASS CLOTH TAPE IAW ASR A350-A-53-02-XX-18001-662A. (27SDR IPXA2023051278793Floor Panel · damagedFAULT - FOUND MAIN DECK CARGO FLOOR PANEL DAMAGE LOCATION: STA 933 ~ STA 985 RBL 75 - RBL 88 (PANEL NO: 242MFF P/N: 145T5876-84) (REPAIR) REVIEWEDSDR DALA2023051503818Unknown · unknownSHIP 660 CRACK ON STABILIZATION STRAP RBL 25 AT BSTA 700.C1. CORRECTIVE ACTION: SUMMARY OF NRC 00178: STABILIZATION STRAP RBL 25 AT BSTA 700 WAS REPAIRED PER B757-200 SRM. (2761271)SDR DALA2023051503817Unknown · unknownSHIP 672 SECONDARY NRC: IN REF. NRC 00228: CORROSION ON STRINGER FLOOR SUPPORTS RBL/LBL 2 STA 1470-1498 (OUT OF LIMITS) AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00800: STRINGER FLOOR SUPPORTS RBL/LBL 2 STA 1470-1498 AT AFT CARGO COMPARTMENT SDR DALA2023051503816Unknown · unknownSHIP 688 IN REF NRC 00436 ATTEND AREA OUT LIMITS (STA 1640 BTW RBL 13). CORRECTIVE ACTION: SUMMARY NRC 00550: FLOOR BEAM UPPER CHORD STA 1640 BTW RBL 13 AND RBL 16 WAS REPAIRED PER B757-200 SRM. (2761078)SDR DALA2023051503815Unknown · unknownSHIP 660 CORROSION ON FLOOR SUPPORT STA. 760, BTW RBL 45 TO RBL 52 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00566: FLOOR SUPPORT WAS FABRICATED PER B757-200 DWG 143N5845-45 REV- AND NEW FLOOR SUPPORT WAS REPLACED PER B757-200 SRM. (27610SDR DALA2023051503814Unknown · unknownSHIP 672 IN REFERENCE TO NRC 00480: CORROSION ON FLOOR STRINGER LBL 7.55 BETWEEN STA 640 TO STA 704 FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00791: FLOOR STRINGER LBL 7.55 BETWEEN STA 640 TO STA 704 WAS REPLACED PER B757-200 SRM. (2760984)SDR DALA2023051503813Unknown · unknownSHIP 672 IN REF TO NRC 00231: CORROSION ON STRINGER FLOOR SUPPORT RBL 7 STA 1470-1498 AND PREVIOUS REPAIR DOBLER STA 1510 RBL/LBL 7 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00801: FLOOR SUPPORT RBL 7 STA 1470-1498 AND PREVIOUS REPAIR DOBLER SDR DALA2023051503812Unknown · unknownSHIP 672 IN REF. TO NRC 00192: CORROSION ON RH SIDE PLATE (UPPER/LOWER SURFACES) AT AFT CARGO COMPARTMENT, ON STA 1561 AND 1595. CORRECTIVE ACTION: SUMMARY OF NRC 00780: SIDE PLATE AT AFT CARGO COMPARTMENT, ON STA 1530 TO STA 1640 WAS REPAIRED PER B757-200 SRM
Back to JASC 5321