JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023061651060Floor Panel · brokenFLOOR PANEL 221GF HAS A BROKEN TAB.<[01] IDENTIFIED FLOOR PANEL 221GF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 F<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-6 <BR><BR>REMOVED (2EA) TSDR SWAA2023070550629Floor Panel · deterioratedAFT CARGO COMPT. FLOOR PANEL 140DF DETERIORATED.<[01] AFT CARGO FLOOR PANEL #140DF WAS FABRICATED NEW ON JOB CARD TTG8QOO1RJXW.;[02] CORRECTION TO STEP 1: AFT CARGO PANEL #140DF WAS FABRICATED NEW ON JOB CARD TTG8Q001RJXW.;[03] VERIFIED STEP 2 PANEL FABRICATEDSDR SWAA2023070550627Floor Panel · deterioratedAFT CARGO COMPT. FLOOR PANEL 140AF DETERIORATED.<[01] AFT CARGO PANEL #140AF WAS FABRICATED NEW ON JOB CARD TTG8QOO1RJXW.;[02] CORRECTION TO STEP 1: AFT CARGO PANEL #140AF WAS FABRICATED NEW ON JOB CARD TTG8Q001RJXW.;[03] VERIFIED PANEL FABRICATED ON TTG8Q001RSDR SWAA2023070550630Floor Panel · deterioratedAFT CARGO COMPT. FLOOR PANEL 140BF DETERIORATED.<[01] AFT CARGO PANEL #140BF WAS FABRICATED NEW ON JOB CARD TTG8QOO1RJXW.;[02] CORRECTION TO STEP 1: AFT CARGO PANEL #140BF WAS FABRICATED NEW ON JOB CARD TTG8Q001RJXW.;[03] VERIFIED STEP 2 PANEL FABRICATED ON TTSDR SWAA2023070550633Floor Panel · deterioratedFWD CARGO COMPT. FLOOR PANEL 120AF DETERIORATED.<[01] FWD CARGO PANEL #120AF WAS FABRICATED NEW ON JOB CARD TTG8QOO1RJXW.;[02] CORRECTION TO STEP 1: FWD CARGO PANEL #120AF WAS FABRICATED NEW ON JOB CARD TTG8Q001RJXW.;[03] VERIFIED STEP 2 PANEL FABRICATED ON TTSDR SWAA2023070550634Floor Panel · deterioratedFWD CARGO COMPT. FLOOR PANEL 120CF DETERIORATED.<[01] FWD CARGO PANEL #120CF WAS FABRICATED NEW ON JOB CARD TTG8QOO1RJXW.;[02] CORRECTION TO STEP 1: FWD CARGO PANEL #120CF WAS FABRICATED NEW ON JOB CARD TTG8Q001RJXW.;[03] VERIFIED STEP 2 PANEL FABRICATED ON TTSDR SWAA2023061650606Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 221BF IS DELAMINATED ON PANEL.<[01] IDENTIFIED PANEL 221BF MATERIAL IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2.<BR><BR>FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F.<BR><BR>REPAIR TO BE ACCOMPLISHED IAW SRM 53SDR SWAA2023061650608Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 221DF HAS DELAMINATION ON PANEL.<[01] IDENTIFIED PANEL 221DF MATERIAL IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2.<BR><BR>FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F.<BR><BR>REPAIR TO BE ACCOMPLISHED IAW SRM SDR SWAA2023061650609Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 221CF HAS DELAMINATION ON PANEL<[01] IDENTIFIED FLOOR PANEL 221CF IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2 AND BOEING DWG 141A5810-9.<BR><BR>DAMAGE NOTED TO UPPER SURFACE SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1SDR SWAA2023061650610Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 221FF HAS DELAMINATION ON PANEL.<[01] IDENTIFIED FLOOR PANEL 221FF IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2 AND BOEING DWG 141A5810-157.<BR><BR>DAMAGE NOTED TO UPPER SURFACE SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1SDR SWAA2023061650611Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 222CF HAS DELAMINATION ON PANEL<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>RSDR SWAA2023061650607Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 222DF HAS DELAMINATION ON PANEL.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>SDR SWAA2023052350902Floor Panel · delaminatedSUSPECT FLOORBOARD AT ROW 17 DELAMINATED<[01] REMOVED AND REPLACED FLOOR PANEL AT SEAT ROW 17 PER AMM 53-21-00SDR AALA202305221799Floor Panel · damagedAIRCRAFT WAS GROUNDED: MID CABIN ROW 8 FLOORBOARD SOFT. FLOORBOARD REPLACED.SDR SWAA2023062050392Floor Panel · brokenBROKEN FLOOR PANEL 221GF AT AT FWD GALLEY AREA 2023-334348<[01] REPLACED FLOOR PANEL 221GF AT AT FWD GALLEY AREA IAW AMM 53-21-00-400-801. AND THE INSTALLATION OF THIS PANEL WILL BE CARRIED OUT WITH TTG8Q00KAQHK;[02] CORRECTED STEP 1<BR>REPLACED FLOOR PANEL 22SDR SWAA2023062050377Floor Panel · brokenBROKEN FLOOR PANEL 241ADF AT AFT GALLEY AND LAV 2023-334341<[01] TOOL USED= CALIPER P/N: 500-197-30; S/N: B20189416; DUE DATE: 19-DEC-23.;[02] REPLACED FLOOR PANEL 241ADF AT AFT GALLEY AND LAV I.A.W B737-700 AMM 53-21-00-400-801 AND THE INSTALLATION OF THIS PASDR DALA2023052204083Unknown · unknown(LOG 2774558) DURING INSPECTION FOUND PASSENGER COMPARTMENT, FLOOR BEAM FASTENER HOLES AT WL 208 BS. 927, LBL 10 AND RBL 10 HAS CORROSION. REPAIRED PER ERA 608269-14 REV ORIGINAL.SDR DALA2023052204068Unknown · unknownSHIP 3219 CRACK ON LOWER FLANGE FR 19 AT LEVEL STR 40 RH ON NLG AREA. CORRECTIVE ACTION: REPAIRED PER A320 SRM 51-72-11. (2774693)SDR DALA2023052204051Unknown · unknownFWD CARGO DOOR SILL/JAMB, EVIDENCE OF CORROSION AROUND FASTNERS IN THE SILL AREA. (MARKED). SUMMARY SEE NRC 001-0312:5231-2003/007 00134: REPLACED FWD CARGO DOOR LOWER JAMB PAN REF B717 SRM 53-20-15-2R-6. (LP #2774676)SDR SWAA2023061349898Intercostal · crackedFWD CABIN WET AREA SIDE WALL INTERCOSTAL CRACKED @ S-15L BETWEEN. STA 294.5 AND 303.9 WL 208.1<[01] INSTALL REPAIR ANGLE WITH FASTENERS PER FIGURE 1-1 OF 23-153-01662-WIP1. AND SRM 51-40-02-0G-0;[02] VERIFIED STEP 1;[03] REQUIRE INDEPENDANCE CHECKSDR DALA2023052504157Unknown · unknownCORROSION SHEAR PLATE R/H AT AFT GALLEY AREA. REPLACED SHEAR PLATE LOC. ON R/H AT AFT GALLEY AREA AS PER A321 SRM 51-72-11, A321 SRM 51-42-11 AND DWG# D53474180, RELEASE DATE:14-JUL-22, ISSUE: Z RII INSPECTION COMPLETE 0855335 (AE354QC) JOB COMPLETE. (LP# 2773SDR DALA2023052204079Panel · corroded(LOG 2773704) DURING INSPECTION FOUND FORWARD CARGO COMPARTMENT L/H FLOOR TRANSITION PANEL HAS AREAS OF CORROSION ON UPPER SURFACE BETWEEN BS 500D AND BS 500L. LOCATED, DRILLED AND ASSEMBLED REPLACEMENT PANEL AND SPLICE FROM 7075 T 6 ZEE CHANNEL EXTRUSION. IAWSDR SWAA2023053149396Floorboard · pulledDOT 114-015. CABIN FLOOR BOARD 242AF HAS AREAS OF PULLED FIBER.<[01] EVALUATED PANEL 242AF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;E SDR SWAA2023053149402Floorboard · pulledDOT 114-012. CABIN FLOOR BOARD 232YF HAS AREAS OF PULLED FIBERS.<[01] EVALUATED PANEL 232YF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;CSDR SWAA2023053149397Floorboard · pulledDOT 114-010. CABIN FLOOR BOARD 232RF HAS AREAS OF PULLED FIBERS.<[01] EVALUATED PANEL 232RF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;CSDR SWAA2023053149412Floorboard · pulledDOT A24-20 MID CABIN FLOOR BOARD 231XF HAS COMPOSITE PULLED FIBERS ON UPPER SURFACE.<[01] EVALUATED DAMAGE; TOP SIDE OF PANEL IS REPAIRABLE IAW B737 SRM 53-00-50-2R-1 REPAIR 1; TAP TEST GOOD NO DELAMINATION NOTED. <BR><BR>VERIFIED REPAIR MATERIALS IAW B737 SRMSDR SWAA2023053149409Floorboard · pulledDOT A24-21 MID CABIN FLOOR BOARD 241AF HAS COMPOSITE PULLED FIBERS ON UPPER SURFACE.<[01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-SDR DALA2023052004041Unknown · unknownCORROSION WAS FOUND ON FLOOR SUPORT STA Y=180 BTW RBL 44 TO RBL 10 CABIN PAX (CPAX) AFTER REMOVAL OF SUPPORT. SUMMARY OF NRC 00547: CORROSION LEVEL 2. FLOOR SUPORT STA Y=180 BTW RBL 44 TO RBL 10 WAS REPLACED PER B717-200 SRM 53-10-51- 01 PROC 2 AND MUST BE INSSDR DALA2023051803965Unknown · unknownCRACK SHEAR PLATE L/H AT AFT GALLEY AREA. REPLACED SHEAR PLATE LOC. ON L/H AT AFT GALLEY AREA AS PER A321 SRM 51-72-11, A321 SRM 51-42-11 AND DWG# D53474180, RELEASE DATE:14-JUL-22, ISSUE: Z RII INSPECTION COMPLETE 1942138 (AE398QC) JOB COMPLETE. (LP# 2771630)SDR DALA2023051803961Unknown · unknownSHIP 3356 CRACK FLOOR STRUCTURE PROFILE AT LEVEL STR26L BTW FR75/FR77 AT AFT GALLEY AREA (1 EA). CORRECTIVE ACTION: REMOVED AND REPLACED PROFILE AT LEVEL STR26L BTW FR75/FR77 AT AFT GALLEY AREA (1 EA). RII INSPECTION COMPLETE. (2771979)SDR DALA2023051803960Unknown · unknownSHIP 3356 CRACK FLOOR STRUCTURE PROFILE AT LEVEL STR26R BTW FR75/FR77 AT AFT GALLEY AREA (1 EA). CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR STRUCTURE PROFILE AT LEVEL STR26R BTW FR75/FR77 AT AFT GALLEY AREA (1E/A). RII INSPECTION COMPLETE. (2772004)SDR DALA2023051803958Unknown · unknownSHIP 3351 CORROSION FLOOR BEAM -Y2462 LOCATED FR31 TO FR37 RH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR ON FLOOR BEAM -Y2462 LOCATED BTW FR 31 TO FR 37 RH SIDE ON PASSENGER CABIN. SEAT SECTION AND SPLICES (4 EA) WAS MACHINED AND DOSDR ASAA2023051645209Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251RF HAS MISSING MATERIAL GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 251RF IAW A320 AMM 53-00-00-400-801-A AND 53-00-00-000-801-A.SDR SWAA2023053149393Floorboard · pulledDOT 114-002. CABIN FLOOR BOARD 232SF HAS PULLED FIBERS.<[01] EVALUATED PANEL 232SF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP FOR REPAIR. IAW B737-700 SRM 53-00-50-2R-1 PAR 3ASDR DALA2023051803975Unknown · unknownSHIP 672 CORROSION ON RH SIDE PANEL UPPER/LWR FACES BTW STA 645-765 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00428: RH SIDE PANEL BTW STA 645-765 AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 SRM. (2769159)SDR FDEA202305160877Floor Panel · crackedMAIN DECK CARGO FLOOR PANEL P/N:152W8650-3 FOUND CRACKED AT STA 1660 RBL1. EVALUATED THE MAIN DECK CARGO FLOOR PANEL P/N:152W8650-3 CRACKED AT STA 1660 RBL1.DAMAGE SIZE L=2.7", OUT OF ALLOWABLE LIMIT .AS PER B777 SRM53-00-50-1A ALLOWABLE DAMAGE 1 REV.43.SDR FDEA202305160876Floor Panel · crackedMAIN DECK CARGO FLOOR PANEL P/N:152W8650-4 FOUND CRACKED AT STA1780 RBL1. EVALUATED THE MAIN DECK CARGO FLOOR PANEL P/N:152W8650-4 CRACKED AT STA1780 RBL1 DAMAGE SIZE L=2.5", OUT OF ALLOWABLE LIMIT. AS PER B777 SRM53-00-50-1A ALLOWABLE DAMAGE 1 REV.4SDR DALA2023051803974Unknown · unknownSHIP 688 IN REF TO NRC 159: CORROSION ON FLOOR FITTINGS (2EAS) ON STA 715 TO STA 720 L2. CORRECTIVE ACTION: SUMMARY NRC 00565: FLOOR FITTING STA 720 WAS REPLACED PER B757-200 SRM. FLOOR FITTING STA 715 WAS FABRICATED PER DWG 143N8328-59 REV. R. AND REPLACED PESDR DALA2023051803973Unknown · unknownSHIP 688 CORROSION ON FLOOR STGR STA 1280 LBL 2 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY NRC 00218: CORROSION ON FLOOR STGR STA 1280 LBL 2 WAS REPAIRED PER B757-200 SRM. (2768755)SDR DALA2023051803972Unknown · unknownSHIP 672 CORROSION ON LOWER SPLICE OF RH SIDE PANEL BTW STA 640-660 AND STGR 28R-26R AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00530 SPLICE OF RH SIDE PANEL BTW STA 640-660 AND STGR 28R-26R AT FWD CARGO COMPARTMENT WAS REPLACED PER DWG 143N53SDR DALA2023051803971Unknown · unknownSHIP 688 CORROSION ON BEAM STA 1661 BL 0 AT W4 AREA. CORRECTIVE ACTION: SUMMARY NRC 00443: CORROSION ON BEAM STA 1661 BL 0 AT W4 AREA WAS REPAIRED PER B757-200 SRM. (2768523)SDR DALA2023051803970Unknown · unknownSHIP 660 CORROSION ON UPPER CHORD BEAM STA. 1640 FROM LBL 45 TO RBL 45 AT PASSENGER FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00619: PREVIOUS REPAIR OF UPPER CHORD BEAM STA. 1640 FROM LBL 45 TO RBL 45 WAS REPLACED PER. ER/A: 478221-14 REV. (2768387)SDR DALA2023051803969Unknown · unknownSHIP 660 SECONDARY IN REF. A NRC 00624: CORROSION ON THRESHOLD SUPPORT NP 146N8769-47 (2EAS) AND NP 143N8328-60 (2EAS) FROM STA. 1650 TO 1670 AT 4L LOWER SILL AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00735: THRESHOLD SUPPORTS (4 EAS) WERE REPLACED PER B-757-200SDR DALA2023051803968Unknown · unknownSHIP 672 CORROSION ON FLOOR SUPPORT LBL 16.10 BETWEEN STA 730 TO 760 FWD CARGO COMPARTMENT. CORRECTIVE ACITON: SUMMARY OF NRC 00489: FLOOR SUPPORT LBL 16.10 BETWEEN STA 730 TO 760 FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 SRM. (2767022)SDR DALA2023051803967Unknown · unknownSHIP 688 CORROSION ON ANGLE SUPPORT (2 EAS) STA 1681 APROX RBL 52 AND LBL 52 AT W4 AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00440: ON ANGLE SUPPORTS (2 EAS) STA 1681 APROX RBL 52 AND LBL 52 AT W4 AREA WAS EVALUATED PER B757-200 SRM. (2766151)SDR DALA2023051603859Unknown · unknown(LOG 2766794) DURING INSPECTION FOUND BENT FRAME BS 500K BTW STR 27L TO STR 25L AT FWD CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON FRAME BS 500K BTW STR 23L TO STR 27L AT FWD CARGO COMPARTMENT, AS PER B737-900ER SRM 53-30-07-2RREPAIR 1.SDR DALA2023051503850Unknown · unknownSHIP 3356 CORROSION ADAPTER ASSY-SEAT TRACK YB1 BTW FR73/FR74 AT AFT GALLEY AREA (1 EA). CORRECTIVE ACTION: REPLACED ADAPTER ASSY-SEAT TRACK YB1 LOC BTW FR73/FR74 AT AFT GALLEY AREA (1 EA). RII INSPECTION COMPLETE. (2767109)SDR DALA2023051503848Unknown · unknownSHIP 3356 CORROSION FLOOR BEAM LOCATED -Y1552.5 FR31 TO FR37 RH SIDE IN PASSENGE R CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1552.5 LOCATED FR31 TO FR37 RH SIDE IN PASSENGER CABIN AND INSTALLED BRAKETS (12EA), SPLICE (12EA) AND FASTENERS. FLOOR BEAM WAS SDR ASAA2023051343750Floorboard · corrodedMAIN CABIN FLOOR BOARD 221FF UPPER SKIN IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN FLOOR BOARD 221FF AT FR16 TO FR20, LBL 52 TO LBL 73 IAW A321 AMM 53-00-00-400-801-A-01.SDR SWAA2023062048275Floor Panel · pulledFLOOR PANEL 242DF UPPER SURFACE HAS PULLED STRANDS.<[01] PANEL DAMAGE TO MARKED AREA WITH PULLED STRANDS EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR. 4. F.<BR><BR>FABRICATING NEW FLOORBOARD IAW SRM 53-00-50-2R-0 PAR. 1. A. NOTE:<BR><BR>FABRICATED
Back to JASC 5321