SDR CALA9601535Floor · corrodedINSPECTION FOUND LEFT AFT LAV FLOOR AREA HAD CORROSION IN SEVERAL AREAS AND UNDER MYLAR COVERING. THE FLOOR CORROSION WAS REMOVED. A REPLACEMENT WALL SUPPORT CHANNEL WAS FABRICATED AND INSTALLED IAW SRM 51-10-1.SDR COMA9630151Floorboard · corrodedC1 INSPECTION TASK 117/118-01I. CORROSION UNDER FLOORBOARDS ON RT SIDE OF COCKPIT THRESHOLD UNDER GALLEY AREA. REMOVED CORROSION, CLEANED, PRIMED, AND RESTORED CORROSION PREVENTATIVE COMPOUND.SDR AALA961475Floor · corrodedAFW - FOUND FLOOR AT STATION 405 RBL 12 HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-967. (M)SDR AALA961469Floor · corrodedAFW - FOUND FLOOR AT STATION 405, RBL 59, HAD CORROSION BLENDED BEYOND SRM LIMITS. REPAIRED PER MRB 757-960. (M)SDR AALA961467Floor · corrodedAFW - FOUND FLOOR AT STATION 405, RBL 12 HAD CORROSION BLENDED BEYOND LIMITS. REPAIRED PER MRB 757-968. (M)SDR ORJA9679Floor · corrodedFLOOR PANEL IN AFT CARGO PIT HAS EXFOLIATION CORROSION. FABRICATED NEW FLOOR PANEL, DRILLED, TREATED, AND PRIMED IAW SRM 51-10-2, 51-10-3, 51-10-4. (M)SDR EIAA9639Floor · crackedSAT - CABIN FLOOR WEB CRACKED AT STATION 520 FORWARD AND AFT, AND CORRODED AT STATION 455, LBL 11. REPAIRED WEB AND INSTALLED DOUBLER PER SRM 51-20-01, 51-40-2, AND 51-10-02. REMOVED CORROSION, TREATED, ALODINED, AND PRIMED PER SRM 51-10-01. (M)SDR AALA961421Floor · corrodedTUL - FOUND CORROSION ON LEFT AFT LAV FLOOR AT STATION 1170 TO STATION 1176. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 51-40-2 PAGES 1-6. (M)SDR AALA961405Floor · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-943. (M)SDR AALA961404Floor · corrodedAFW - AFTER BLENDING CORROSION THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-945. (M)SDR UPS96821401Floor Pans · corrosionINSPECTION TYPE: CS2. FS 55 RBL 30 AND RBL 20. RECESSED FLOOR PANS HAVE EXFOLIATED. CORROSION REPLACED FLOOR PANS PER SRM 51-1-20D.SDR DHL9672223CFloor · corrodedAT C-CHECK, FOUND HEAVY CORROSION ON CABIN FLOOR AT BS 1176 LBL 66. REMOVED CORROSION, INSTALLED NEW CHORD ANGLE LBL 66 TO RBL 66, INSTALLED NEW CHORD ANGLE PER SRM 51-30-2. INSTALLED AFT DOOR THRESHOLD PER SRM 51-30-2.SDR AALA961342Floor · corrodedAFW - FOUND AFTER REMOVING CORROSION, THE REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-930. (M)SDR AALA961340Floor · corrodedAFW - AFTER REMOVING CORROSION, FOUND REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIRED PER MRB 757-929. (M)SDR HEEA967773Floor Panel · mis mfgNEW FLOOR DOES NOT HAVE PROPER JOGGLE ON INBOARD AND FORWARD EDGES OF PANEL AS NEEDED TO GO BELOW (-051) LARGE FLOOR.SDR HEEA967772Floor Panel · mis repairedFLOOR PANEL WAS REPAIRED AND EXISTING INSERTS IN FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW TOP SKINS WERE INSTALLED. THE OLD INSERTS INSIDE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW STYLE INSERTS THAT MUST GO THROUGH TOP ANDBOTTOM SKINS. SENT TO SDR HEEA967771Floor Panel · mis repairedFLOOR PANEL WAS REPAIRED AND EXISTING INSERTS IN FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW SKINS WERE INSTALLED. THE OLD INSERTS INSIDE THE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW STYLE INSERTS THAT MUST GO THROUGH TOP ANDBOTTOM SKINS. TIME SINSDR HEEA967752Panel · damagedEDGE OF PANEL CUT FROM INSTALLATION HOLE. TIME SINCE REPAIR 0:00.SDR UPS96521036Floor Panel · corrodedINSPECTION TYPE-3C, CORROSION ON FLOOR PANEL ON LOWER CENTER OF COCKPIT. REMOVED CORROSION AND FOUND OUT OF LIMITS, FABED NEW PANEL AND INSTALLED. ALL WORK PER SRM 51-40-02, 51-10-01, 53-00-51, 51-30-01 AND 53-00-50.SDR AALA961296Floor Board · corrodedTUL - FOUND CORROSION TWO PLACES AT FORWARD END OF CENTER FLOOR BOARD SUPPORT UNDER LAV. INSTALLED NEW FLOOR BOARD SUPPORT UNDER LAV 'V' PER SRM 51-72-10. (M)SDR AALA961290Floor Board · corrodedTUL - FOUND INBOARD FLOOR BOARD SUPPORT BEAM FOR G-7 GALLEY CORROSION. INSTALLED INBOARD FLOOR BOARD SUPPORT FOR G-7 GALLEY PER SRM 51-72-10. (M)SDR AALA961257Floor Pan · corrodedTUL - FOUND AREA OF RIGHT AFT LAV FLOOR PAN WEB HAS HEAVY CORROSION IN AREA OF HOLE FOR DUMP SHUTE FLANGE. REMOVED CORRODED AREA. INSTALLED REPAIR PER SRM 51-40-2, PG 1-6. (M)SDR AALA961258Floor Pan · corrodedTUL - FOUND CORROSION ON FLOOR PAN RIGHT AFT LAV. CUT OUT CORRODED AREA AND INSTALLED DOUBLER PER SRM 51-40-2 PG 1-6. (M)SDR AALA961256Floor Pan · corrodedTUL - FOUND RIGHT AFT LAVATORY (FLOOR PANEL) CORRODED AT SEVERAL AREAS, (FWD TO AFT) AREA MARKED. INSTALLED TYPICAL WEB REPAIR SRM 51-40-2 PG 1-6. (M)SDR AALA961254Floor Pan · corrodedTUL - FOUND CORROSION ON LAV FLOOR PAN, AT STATION 1175 RBL 34-36. REMOVED CORRODED SECTION OF FLOOR PAN AND INSTALLED REPAIR DOUBLER PER SRM 51-40-2 FIG 1 PAGE 6. (M)SDR RRXA96159Floor Panel · separatedDURING A MAINTENANCE VISIT, FOUND AFT LOWER FLOOR PANEL MODIFICATION SEPARATING FROM GILL BOARD ON BOTH SIDES OF PANEL, AT Y=1220 TO Y=1320. REPAIRED PANEL BY RESEALING PANEL TO GILL BOARD IAW DAC-DRW 2277-006 REV F, TREATED AREA IAW DC-8 SRM 51-1-8.SDR P5CA9601134Floor · corrodedHITS AND CORROSION ON SHEET METAL FLOOR COVER BETWEEN STA 860 TO 880 BETWEEN AREA LBL TO RBL 58. AREA SMOOTHED, CORROSION REMOVED AND TREATED PER SRM 51-10-01.SDR P5CA9601067Floor · crackedCRACK ON FLOOR SHEET METAL AT STRINGER 26 AREA NEAR STA 780 RT SIDE. FAB NEW PART PER SRM 53-10-21 AND 51-30-02.SDR AALA961214Deck Plate · corrodedAFW - AFTER CORROSION REMOVAL, REMAINING THICKNESS BEYOND SRM LIMITS. REPAIR PER MRB 757-902. (M)SDR AALA961183Floor Pnl · corrodedTUL - FOUND LEFT AFT LAVATORY FLOOR CORRODED THREE PLACES AND AROUND THE PUMP SHUTE TO THE ANGLE AT THE DITCHING PANELS. MADE STAINLESS STEEL WEB REPAIR, CAD-PLATED AND PRIMED AND INSTALLED WITH 870 SEALER REF SRM 51-40-2. (M)SDR P5CA9600460Floor · crackedCRACKED FLOOR PANEL AFT CARGO COMPARTMENT BS 1680 AT CENTER LOCK. REPAIRED PER BOEING SRM 51-30-02.SDR AALA961150Deck Plate · corrodedAFW - DECK PLATE WITH CORROSION REMOVED. REMAINING MATERIAL IS BEYOND SRM LIMITS. REPAIR PER MRB 757-889. TST: 15,172 HOURS. CYCLES: 5,361. (X)SDR ABXA9700109Floor Panel · puncturedDURING C-CHECK AND COMPLIANCE WITH AD 92-22-08, FOUND HOLE IN SUBFLOOR STA 160.SDR CALA9601142Floorboard · corrodedINSPECTION FOUND COCKPIT FLOORBOARD AT FIRST OFFICER'S SEAT TRACK CORRODED. THE FLOORBOARD WAS REPLACED IAW SRM 51-10-02.SDR P5CA9600562Floor · corrodedLEVEL 1 CORROSION LEFT OTBD MAIN DECK FLOOR WEB UPPER SURFACE BS 2160 TO BS 2200. REMOVED CORROSION AND RE-PROTECTED PER BAC SRM 51-01-01.SDR P5CA9600551Floor Plate · corrodedLEVEL 1 CORROSION AFT BULK CARGO DOOR SILL ENTRY FLOOR PLATE UNDER SCUFF PLATE UPPER SURFACE AT BS 1980 TO 2040. CORROSION REMOVED AND TREATED PER BOEING SRM 51-10-01 AND 51-10-02.SDR P5CA9600550Floor Plate · corrodedLEVEL 1 CORROSION AFT CARGO FLOOR PLATE UPPER SURFACE BS 1850 RBL 7 TO RBL 14. REMOVED CORROSION AND TREATED PER BOEING SRM 51-10-01 AND 51-10-02.SDR AALA961071Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION BLENDED BEYOND SRM LIMITS IN VARIOUS LOCATIONS PER MRB 757-880. TST: 15,185 HOURS. CYCLES: 5,323. (X)SDR P5CA9600309Floor Panel · puncturedFOUND HOLE IN BULK CARGO PIT AT FORWARD RIGHT HAND END. REPAIRED HOLE IN FLOOR IAW SRM 51-40-02.SDR P5CA9600303Floor Panel · damagedFOUND AFT CARGO COMPARTMENT RIGHT HAND WALKWAY HAS A HOLE JUST FWD OF ENTRY DOOR. REPAIRED HOLE IN CARGO FLOOR IAW SRM 51-40-02.SDR UPS96220576Floor · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR STA 209 TO 231 LBL 6 TO 18 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REPLACED FLOOR PANEL PER SRM 51-40-2, 51-10-2 MM 51-20-151, SRM 51-30-02.SDR AALA961011Deck Plate · corrodedAFW - FOUND DECK PLATE CORROSION BEYOND SRM LIMITS. REPAIR PER MRB 757-871. (M)SDR 9614795513Plate · corrodedDURING P-CHECK, FOUND CORROSION ON THE AFT GALLEY DECK PLATE AT BS 1681 BETWEEN LBL 54 TO RBL 54. REPAIRED PLATE (P/N 146N5318-3) PER EA 55-106107.SDR P5CA9600262Floor Panel · damagedFOUND FLOOR DAMAGED ON MAIN CARGO DECK STA 1720-1740 LT. REMOVED AND REPLACED FLOOR PANELS IAW SRM 51-32-01.SDR UPS96520402Floor · corrodedINSPECTION TYPE: C. CORROSION ON CONTROL CABIN FLOOR AT BS STA 255-297 FROM BL ZERO-RBL 10, BL ZERO-BL 15 AND LBL 15-LBL 30. REMOVED CORROSION PER SRM 51-20-01. FOUND TO BE OUT OF LIMITS PER SRM 53-00-01 AT BS 297, LBL 15 TO LBL 30. REPAIRED PER SRM 51-70SDR AALA960903Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVED IN VARIOUS LOCATIONS, CORROSION REMOVED IS BEYOND SRM LIMITS. PER MRB 757-855. (M)SDR 96ZZZM1164Deck · corrodedFOUND LEVEL 2 CORROSION, MAIN CABIN PRESSURE DECK FLOOR IS CORRODED FS 328 AND FS 349 TO RBL 51. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-11-00.SDR 96ZZZM1163Deck · corrodedFOUND LEVEL 2 CORROSION, MAIN CABIN PRESSURE DECK FLOOR IS CORRODED BETWEEN FS 349L AND 369L LBL 100. REMOVED DAMAGED AREA FABRICATED AND INSTALLED REPAIR PER SRM 53-11-00.SDR 96ZZZM1162Deck · corrodedFOUND LEVEL 2 CORROSINO, MAIN CABIN PRESSURE DECK FLOOR CORRODED BETWEEN FS 329L TO FS 349L LBL 110. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-11-00.SDR P5CA9600285Floor Panel · delaminatedFOUND MAIN DECK BS 500, RBL 20, FLOOR PANEL ASSEMBLY DELAMINATED. REMOVED AND REPLACED FLOOR PANEL IAW SRM 51-30-02.
Back to JASC 5321