Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 9613535507Deck Plate · corrodedDURING P-CHECK, FOUND CORROSION ON THE AFT GALLEY FLOOR STRUCTURE DECK PLATE, SHEAR WEB BS 1681 TO 1720. REPAIRED PLATE (P/N 146N5318-3) PER EA 55-106091.SDR UPS96220484Floor · crackedINSPECTION TYPE SI, CRACKED FLOOR AT HYLOCK BS 296, RBL 21, WL 208. REMOVED HYLOCK NDI LOCATED AND MARKED FOR STOP DRILLING NOTED. CRACK INDICATION STOP DRILLED CRACKS FOUND CRACKS TO BE CONTAINED. FABRICATED AND INSTALLED REPAIR DOUBLER IAW 51-10-02 SRM 51SDR UPS96220481Floor · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR WEB STA 460 WL 208, LBL 52 AREA MARKED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, CUT OUT DAMAGED AREA AND REPAIRED PER SRM 51-40-02.SDR MALA965043Floor Board · crackedDURING A SCHEDULED INSPECTION IN MSP, MAINTENANCE FOUND A CRACKED OUT RIVET HOLE IN RIGHT CENTER AISLE FLOOR BOARD WEB AT FS 227.221. CRACK LENGTH APPROXIMATELY .300. COMPLETED REPAIR BY STOP DRILLING CRACK, FABRICATING AND INSTALLING A REPAIR DOUBLER. LENGSDR AALA960807Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE AT VARIOUS LOCATIONS. MATERIAL REMOVED IS BEYOND SRM LIMITS, PER MRB 757-839. (M)SDR USAA960588Floor Panel · corrodedYYC - DURING FC-06 CHECK, FOUND SEVERAL SMALL AREAS OF CORROSION ON GALLEY FLOOR PANEL 24AB. CORROSION CLEANED AND TREATED. FLOOR BOARD REPAINTED PER SRM 51-10-04. (X)SDR ABXA9600560Floor Panel · puncturedDURING C-CHECK INSPECTION, FOUND COCKPIT FLOOR PANEL PUNCTURED AFT OF THE PILOT'S CONTROL COLUMN. REPAIRED IAW DC-9 SRM 53-21-0, FIGURE 2B.SDR 96ZZZM1031Floor · corrodedMCI - DURING OP-15, FOUND CORROSION ON TOP AND BOTTOM OF FLOOR MEMBRANE, FS 1174, LBL 48 TO LBL 60. REMOVED CORROSION PER SRM 51-10-3, INSTALLED WEB REPAIR PER SRM 53-01, FIGURE 2 AND 51-30-0, FIGURE 2. (M)SDR DHL9670906CFloor · corrosi0nAT C-CHECK, FOUND CORROSION ON FLOOR SHEAR AT STA 460 APPROX LBL 51. INSTALLED DOUBLER REPAIR PER SRM 51-40-2, 6.5 INCH BY 5 INCH.SDR 96FDEA00925Floor Panel · corrosionNR0420 AND 016, CORROSION (C53-221-01) ON FLOOR PANEL UNDER WIRE BUNDLE ON RT SIDE OF CENTER CONSOLE BS 200 TO 288 WL 208 RBL 4 TO 12.SDR HEEA967106Panel · mis mfgJOGGLE ON PANEL IS 1/16" TOO SHALLOW AND NO EDGE DISTANCE FOR BOLT HOLES. TIME SINCE REPAIR 0:00.SDR CALA9600728Floor Web · corrodedINSPECTION FOUND FLOOR WEB CORRODED AT STA 200, LBL 8. THE CORRODED AREA WAS CUT OUT, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-01.SDR AALA960750Deck Plate · corrodedAFW - FOUND DECK PLATE HAS SEVERAL AREAS OF CORROSION BLENDED BEYOND SRM LIMITS, PER MRB 757-824. (M)SDR CKSA96042Floor Plank · corrodedKOSC - FLT 72016 - DURING 'C-1' CHECK INSPECTION FOUND, CARD NR 5670-0551 AREA, GALLEY (ANY LOCATION) FS 255 LBL 29 FLOOR PLANK CORRODED. LEVEL 2 TASK NR 61940. REMOVED CORROSION, TREATED AND PRIMED AS IT REQUIRED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-8 ANDSDR CKSA96041Floor Plank · corrodedKOSC - FLT 72016 - DURING 'C-1' CHECK INSPECTION FOUND, CARD NR 5670-0551 AREA, GALLEY (ANY LOCATION) FS 255 LBL FLOOR PLANK CORROSION LEVEL 2 TASK NR 61938. REMOVED CORROSION, TREATED AND PRIMED AS IT REQUIRED PER IAW DC-8 SRM 51-1-8, AND INSTALLED REPAIR ACSDR AALA960692Floor · corrodedTUL - FOUND CORROSION ON FLOOR AROUND PLUMBING THROUGH FITTINGS FORWARD OF STATION 1183,LEFT LAV. INSTALLED DOUBLER PER SRM 51-40-2. (M)SDR RAAAB296027Press Floor · crackedDURING SCHEDULED INSPECTION OF THE PRESS FLOOR IN THE LEFT WHEEL WELL PER AD 92-19-11, FOUND THE FOLLOWING 5 CRACKS AT STATION 940, BL 29-1 .375 INCH, BL 31 .625 INCH, BL 36 .375 INCH, BL 38 .75 INCH AND BL 55 1.125 INCH. REPAIRED PER SB 53-0149 RV AND DWG 65SDR PLG41896G6Floor · corrosionDURING ROUTINE C-CHECK INSPECTION, CORROSION FOUND ON STRUCTURE UNDER GALLEY FLOOR AREA. MAINTENANCE REMOVED CORROSION AND REPAIRED DAMAGE IAW SAAB SRM CHAPTER 51. MAINTENANCE TREATED AND REPAINTED IAW SAAB SRM CHAPTER 51. (X)SDR PLG41896G5Floor · corrodedDURING ROUTINE C-CHECK INSPECTION, CORROSION FOUND ON FLOOR UNDER PILOT AND COPILOT'S FLOOR MATS. CORROSION REMOVED AND DAMAGE REPAIRED IAW SAAB SRM CHAPTER 51. (X)SDR GTIA96NK166Floor Board · corrodedDURING C-CHECK, FOUND CENTER COCKPIT FLOOR BOARD CORRODED. FABRICATED, TREATED AND INSTALLED REPLACEMENT FLOOR BOARD IAW 51-10-2, 51-10-3, 51-30-0 AND 51-20-0. (M)SDR AALA960637Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE MATERIAL REMAINING AT VARIOUS LOCATIONS ARE BEYOND SRM LIMITS. PER MRB 757-779. (M)SDR SCNA96088Floor Web · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON A FLOOR WEB SECTION AT BS 1175, RT SIDE. REMOVED CORROSION, FABRICATED REPAIR WEB AND INSTALLED IN ACCORDANCE WITH B727 SRM 51-10-2, 51-30-2 AND MM 51-20-11.SDR 96ZZZX2581Panel · damagedPANEL WAS RECEIVED WITH NO MANUFACTURER'S PART NUMBER OR SERIAL NUMBER TAGS, NOR ANY TRACEABILITY TO A REGISTERED TYPE CERTIFICATED AIRCRAFT. PART APPEARS TO HAVE BEEN REPAIRED OR OVERHAULED, THEN DAMAGED. PANEL IS COVERED WITH DENTS. PANEL WAS RECEIVED AS SDR 96ZZZX3120Floor · corrodedATW - FLOOR PLATE OUTBOARD OF FORWARD AIRSTAIR CLOSET HAS SEVERAL PLACES WITH SURFACE CORROSION. REMOVED SURFACE CORROSION AIRSTAIR CLOSET OUTBOARD SILL AREA, TREATED, PRIMED AND PAINTED.SDR AALA960552Plate · corrodedPLATE IS CORRODED AT AFT GIRT BAR FLOOR FITTING AT FWD SERVICE. REMOVED AND REPLACED WITH NEW PLATE. (M)SDR CAL960509Floor Web · crackedGSO - COCKPIT FLOOR HAS BULGING IN 2 PLACES AND CRACKED FLOOR WEB AT STA 259.5. CRACK LENGTH = .1250 INCH. CUT OUT AND REPLACED FLOOR SECTION AT BS 259.5. CORD SECTION CUT AND SPLICED, FLOOR SUPPORT REPAIRED, FLOOR BEAM WEB CUT AND SPLICED IAW B737, SRM 53-SDR AALA960522Deck Plate · corrodedDECK PLATE HAS CORROSION REMOVAL ON UPPER SURFACE AT VARIOUS LOCATIONS. MATERIAL REMAINING IS BEYOND SRM LIMITS. PER MRB 757-767. (M)SDR DLM88960755Sub Floor · crackedLT SUBFLOOR IS CRACKED AT FS 1300. REMOVED OLD SUBFLOOR AT FS 1300, DRILLED UP NEW SUBFLOOR, INSTALLED SUBFLOOR PER SRM 53-05 PG 380.SDR PLG32596DG3Floor · corrodedPSM - DURING ROUTINE C-CHECK INSPECTION, CORROSION WAS FOUND PILOTS AND CO-PILOTS FLOOR AREA IN COCKPIT. REMOVED CORROSION AND REPAIRED IAW SAAB SRM CHAPTERS 51-53. (M)SDR TC8A96038Floor · corrodedMAIN CARGO COMPARTMENT FLOOR RT SIDE STATION 460, STATION 480 AND STATION 500, TRACK AND WEB AREA HAS CORROSION, LEVEL 2, 5 AREAS. REMOVED AND REPAIRED TRACK AS PER SRM 52-4-0. (M)SDR TC8A96016Floor · corrodedCOCKPIT FLOOR FROM FS 141 THROUGH FS 245 LEFT SIDE (AROUND NR 91 ACCESS PANEL), HAS CORROSION, LEVEL 2. REMOVED CORROSION AND REPAIRED AFFECTED AREA PROPERLY AS PER SRM 52-4-0. (M)SDR AALA960508Deck Plate · coorodedDECK PLATE HAD CORROSION REMOVED AND AREA LEFT IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-754. (M)SDR TC8A96035Floor · corrodedMAIN CARGO COMPARTMENT, GALLEY AND FWD LAV AREA FLOOR HAS LEVEL 2 CORROSION, STATION 265 TO 295. MADE AND INSTALLED GALLEY AND FWD LAV AREA FLOOR AS PER SRM 52-4-0. (M)SDR 96ZZZX1481Panel Assy · deterioratedFLOOR PANEL FOR CENTER SEATS IS A FOAM PANEL WITH METAL TOP AND BOTTOM. FOAM FILLER COMING OUT OF MIDDLE. FOAM FILLER SEEMS TO DRY OUT AND FLAKE APART. SUBMITTER STATED FLOORS FORMERLY MADE OF WOOD. A WOOD FLOOR WITH METAL TOP AND BOTTOM WOULD BE MUCH BETTSDR AALA960318Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVED IN VARIOUS LOCATIONS. MATERIAL REMOVED IS BEYOND SRM LIMITS, PER MRB 757-735. TST: 15,758.46. CYCLES: 5,958. (X)SDR CAL960195Floor Web · corrodedGSO - INSPECTION FOUND RIGHT AFT LAV FLOOR WEB CORRODED AT ATTACH AREAS, RBL 8 AND RBL 15. THE CORRODED AREAS WERE REMOVED. A REPLACEMENT WEB AND ATTACH ANGLE WERE FABRICATED AND INSTALLED IAW BAC DRAWING 65-52457 AND SRM 51-40-02. (M)SDR ABXA9600403Floor Panel · damagedDURING C AND D-CHECK ACCEPTANCE INSPECTIONS, FOUND A FLOOR PANEL DAMAGED FROM FS 237 TO 313. REPAIRED FLOOR PANEL IAW ABX REA D953-14339-MR.SDR AALA960272Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVED BEYOND SRM LIMITS ON UPPER SURFACE, PER MRB 757-721. TST: 15,773 HRS. CYCLES: 5,917. (X)SDR AALA960218Floor Web · corrodedTULE - FOUND FLOOR WEB CORRODED UNDER THRESHOLD STRIP AT AFT END OF FORWARD GALLEY DOOR OPENING. INSTALLED CUSP DOUBLER AS PER SRM 53-01 FIG 2. (M)SDR AALA960217Floor Web · corrodedTUL - FLOOR WEB CORRODED, INBOARD OF FORWARD SERVICE DOOR. SPLICED IN NEW SECTION OF WEB. (M)SDR 96ZZZX1255Floor Panel · corrodedDURING ROUTINE INSPECTION, CARPET WAS REMOVED. FOUND CORROSION ON FLOOR. FURTHER INSPECTION REVEALED CORROSION ON 5 OF 6 FUEL LINES UNDER FLOOR AND ALONG DOOR SILLS AND DOOR POST. SUBMITTER SUSPECTS IMPROPER FLAMEPROOFING ON CARPET CAUSED CORROSION.SDR CAL960266Floor Pan · corrodedINSPECTION FOUND CENTER OF LT AFT LAV FLOOR PAN CORRODED AT BS 1140 TO BS 1176. THE CORROSION WAS REMOVED FROM THE FLOOR PAN. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND SRM 51-20-4. (X)SDR CAL960149Floor Skin · corrodedSTATION 31J - INSPECTION FOUND G2 GALLEY FLOOR AND MOUNT BRACKET CORRODED. THE MOUNT BRACKET AND FLOOR SKIN WERE REMOVED. A NEW FLOOR SKIN WAS FABRICATED AND INSTALLED. THE CORROSION WAS CLEANED FROM BLOCK TIE DOWN AND REBONDED AND A NEW UPPER SHELF WAS INSSDR AALA960171Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVED ON UPPER SURFACE AT SEVERAL LOCATIONS. CORROSION REMOVED IS BEYOND SRM LIMITS. PER MRB 757-699. TST, 15,723.22 HOURS, CYCLES, 5,740. (X)SDR GTIA96NK149Floor · corrodedDURING C-CHECK, FOUND MAIN CABIN FLOOR HAS SURFACE CORROSION BETWEEN STATION 160 AND 200 LBL 12 - LBL 46. FABRICATED AND REPLACED FLOOR BOARDS AND TREATED METAL IAW SRM 51-10-4, 51-70-0, 51-10-3. (M)SDR GTIA96NK147Floor · corrodedDURING C-CHECK, FOUND CABIN FLOOR FROM STATION 120-218 LBL 5 TO RBL 5 CORROSION. REMOVED CORROSION AND TREATED METAL IAW SRM 51-10-3. (M)SDR GTIA96NK144Floor · corrodedDURING C-CHECK, FOUND SURFACE CORROSION ON CREW COMPARTMENT FLOOR PANEL AT STATION 160 LBL 12-RBL 12. REPAIRED FLOOR DOUBLER IAW SRM 53-05, FIG 2. REMOVED CORROSION AND TREATED METAL IAW SRM 53-10-3, AREA WITHIN LIMITS. (M)SDR GTIA96NK143Floor · corrodedDURING C-CHECK, FOUND CORROSION THROUGHOUT THE GALLEY BOTTOM PANEL AND THE MAIN CABIN FLOOR. REMOVED CORROSION IAW SRM 51-10-3. FABRICATED DOUBLER AND INSTALLED, TREATED IAW SRM 51-01 AND SRM 51-10-3. (M)SDR DL73E960156Floor Panel · corrodedDURING HMV, LT FIXED FLOOR PANEL AT FS 777 FOUND CORRODED BEYOND LIMITS. REPAIRED PER MM 53-21-04 PG 801.SDR AALA960078Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION REMOVED ON UPPER SURFACE AT VARIOUS LOCATIONS, PER MRB 757-685. TST, 15,514.52 HOURS. CYCLES, 5,884. (X)
Back to JASC 5321