JASC 5321

Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR GTIA9700062Floor Panel · crackedMHV - FLOOR PANEL 14 FORWARD, ONE CORNER IS CRACKED ABOUT 2 INCHES LONG AND INSULATION BATTING MISSING ALONG ONE EDGE AND OPPOSITE BATTING IS COMING APART. REPAIRED CORNER PER SRM 55-01, FIG 2. TREATED AND PRIMED PER 51-10-3. INSTALLED FASTENERS PER 51-30-2Dec 13, 1996 · N928ML · Doug DC931SDR GTIA9700061Floor Panel · delaminatedMHV - AFT FLOOR PANEL, 1 CORNER IS DELAMINATING AND INSULATION IS MISSING. THERE IS A HOLE IN THE SKIN. FABRICATED A PATCH FOR THE DAMAGE. ALODINED AND PRIMED PATCH IAW SRM 51-10-3. INSTALLED PATCH IAW SRM 51-30-2. INSTALLED RIVETS IN DELAMINATING CORNER Dec 13, 1996 · N928ML · Doug DC931SDR GTIA9700060Floor Panel · deformedMHV - FLOOR PANEL NR 13, FORWARD END OF PANEL IS DEFORMED, RT HAT CHANNEL IS DELAMINATED AT CTR OF PANEL AND DEFORMED AT AFT END. FOUR CORNERS ARE DELAMINATED AND INSULATION IS MISSING. REPAIR HAT CHANNEL DELAMINATION PER SRM 51-30-3. STRAIGHTEN PANEL DAMAGDec 13, 1996 · N928ML · Doug DC931SDR GTIA9700059Floor Panel · brokenMHV - FLOOR PANEL 12 HAT CHANNEL SECTION AT ONE END HAS BROKEN OUT ABOUT 1 INCH LONG. OTHER SECTION HAS DEEP GOUGE. REPAIRED PER 53-21-0. INSTALLED RIVETS PER 51-30-2. BLENDED GOUGE EPR 53-01, REMOVED .008 FROM .040 MATERIAL, WITHIN LIMITS PER SRM 53-01, TDec 13, 1996 · N928ML · Doug DC931SDR GTIA9700058Floor Panel · damagedMHV - FLOOR PANEL, AFT CABIN, UPPER SURFACE HAS HOLES, RIVETS PULLED THROUGH AND CRACKS, LOWER SURFACE HAS CRACKS TO FASTENERS, PROTRUDING UPSET HEADS SHOULD BE FLUSH AND INSULATION TAPE IS LOOSE. REPAIRED HOLE PER SRM 53-05 BY INSTALLING DOUBLER. ALODINED ADec 13, 1996 · N928ML · Doug DC931SDR GTIA9700057Floor Panel · delaminatedMHV - NR 4 FLOOR PANEL HAS DELAMINATING DOUBLER AND SOME AREAS MISSING, ONE CRACKED SCREW HOLE, INSULATION MISSING AND MYLAR BROKEN. REPAIRED DELAMINATING DOUBLER AND INSTALLED MISSING DOUBLERS PER MM 53-20-1. REPAIRED CRACKED SCREW HOLE PER SRM 53-05 AND 53Dec 13, 1996 · N928ML · Doug DC931SDR GTIA9700056Floorboard · brokenMHV - FLOORBOARD WING BOX AREA, ON CORNER, METAL SECTION BROKEN OUT, INSULATION BATTING MISSING ALONG BOTH LONG EDGES, ONE SHORT EDGE HAS UNBONDING, AND OTHER SECTIONS OF SEAL MISSING. REMOVED BROKE SECTION FROM CORNER OF FLOORBOARD FABRICATED FILLER AND DOUBDec 13, 1996 · N928ML · Doug DC931SDR GTIA9700054Floor Panel · delaminatedMHV - NR 23B FLOOR PANEL IS DELAMINATING AT CORNERS. INSULATION TAPE IS LOOSE. REBONDED FLOOR PANELS AT CORNERS WITH SCOTCH GRIP ADHESIVE PER MM 53-20-1 AND RETAPED INSULATION PER MM 25-22-0. (M)Dec 12, 1996 · N928ML · Doug DC931SDR HEEA968700Panel · mis repairedEXISTING INSERTS FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW SKINS WERE INSTALLED. OLD INSERTS INSIDE THE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW STYLE INSERTS THAT MUST GO THROUGH TOP AND BOTTOM SKINS.Dec 11, 1996 · Skrsky S76ASDR GTIA9700050Floor Panel · crackedMHV - NR 19 FLOOR PANEL, CORNER DELAMINATING, INSULATION MISSING CENTER AREAS OF HAT CHANNELS DELAMINATING, SKIN TORN AT CORNER. REPAIRED FLOORBOARD PER SRM 53-05. FABRICATED REPAIR DOUBLER PER SRM 53-5. ALODINED AND PRIMED PER 51-10-3. INSTALLED REPAIR DODec 11, 1996 · N928ML · Doug DC931SDR GTIA9700049Floor Board · corrodedMHV - LEFT FS 237 LBL 44, FLOOR MEMBRANE HAS A CRACK FORWARD OUTBOARD EDGE CORROSION AROUND FITTING AT STATION 237 THAT ATTACHES TO MEMBRANE. CLEANED CORROSION FROM FITTING, REMOVED DAMAGED AREA FABRICATED DOUBLER AND INSTALLED IAW 51-10-3, 51-01-01, 51-10-2,Dec 11, 1996 · N928ML · Doug DC931SDR GTIA9700048Floor Board · tornMHV - LEFT FUSELAGE FLOOR MEMBRANE THAT ATTACHES TO OUTBOARD SEAT TRACK AT STATION 218-237 LBL 44 IS TORN ON FORWARD SIDE. REMOVED OLD MEMBRANE, FABRICATED NEW MEMBRANE AND INSTALLED PER SRM 51-30-01, 51-10-3. (M)Dec 11, 1996 · N928ML · Doug DC931SDR HEEA968667Floor · mis mfgFLOOR DOESN'T HAVE PROPER JOGGLE ON INBOARD AND FWD. EDGE OF PANEL AS NEEDED TO GO BELOW (-051) LARGE FLOOR.Dec 10, 1996 · Skrsky S76ASDR HEEA968666Panel Assy · mis repairedPANEL ASSY CORE TOO LONG AT CENTER OF PANEL WHERE FUEL LINE COVER NUT PLATES NEED TO BE INSTALLED.Dec 10, 1996 · N3904L · Bell 206L1SDR HEEA968665Panel · mis repairedRECENTLY SENT TO DODS FOR REPAIR. EXISTING INSERTS IN FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW TOP SKIN WERE INSTALLED. THE OLD INSERTS INSIDE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW INSERTS THAT MUST GO THROUGH TOP AND BOTTOM SKINS.Dec 10, 1996 · Skrsky S76ASDR GTIA9700047Floor Panel · delaminatedMHV - AFT FLOOR PANEL HAS DELAMINATING DOUBLERS RIVETS PULLED OUT OF HAT CHANNELS AND TEARS IN TOP SKIN OF PANEL. REPAIRED FLOOR BOARD PER SRM 53-05. FABRICATED SKIN REPAIR DOUBLERS PER SRM 53-05. ALODINED AND PRIMED PER SRM 51-10-3. STOP DRILLED TEAR IN TDec 10, 1996 · N928ML · Doug DC931SDR GTIA9700046Floor Panel · crackedMHV - FLOOR PANEL NR 15 HAS NUMEROUS CRACKS AND DELAMINATION. REMOVED DAMAGED AREA, FABRICATED NEW HAT CHANNELS PER SRM 53-05 FIG 1, INSTALLED IAW 51-30-2, 51-30-7. (M)Dec 10, 1996 · N928ML · Doug DC931SDR GTIA9700045Floor Panel · crackedMHV - FLOOR PANEL NR 10 FORWARD HAS 3 HAT SECTIONS WITH CRACKS IN CORNERS (2 AT 1 END AND ONE AT THE OTHER END). ALSO, INSULATION BATTING FALLING APART. REPAIRED HAT SECTIONS IAW SRM 53-05, ALODINED AND PRIMED PER SRM 51-10-3. REPAIRED INSULATION PER MM 25-Dec 9, 1996 · N928ML · Doug DC931SDR GTIA970041Floor Panel · damagedMHV - COCKPIT FLOOR AT STATION 117 RBL 3 INCH FROM CENTER LINE EXISTS DENTS AND A CRACK .823 INCH LONG THROUGH SUB STRUCTURE BARRIER FLOOR AND PLASTIC CABLE SHROUD. REMOVED DAMAGED AREA, FABRICATED AND INSTALL DOUBLERS PER SRM 53-01 FIG 2, 51-10-03, 51-30-02,Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700118Floor · corrodedMHV - FLOOR WEB HAS CORROSION AT STATION 902 RBL 59 ZF1 AND STATION 908 RBL 59 HAS EVIDENCE OF CORROSION BETWEEN WEBS. FABRICATED AND REPLACED CORRODED WEB IAW 51-10-3/51-30-0. (M)Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700043Floor Panel · damagedNR 30 FLOOR PANEL HAS 3 CRACKS. REMOVED DAMAGED MATERIAL, DOT LOCATION 24, 25, 26 AND FABRICATED FILLERS AND DOUBLERS. ALODINED AND PRIMED PER SRM 51-10-3. DRILLED AND COUNTERSUNK PER SRM 51-10-4. INSTALLED RIVETS PER SRM 51-30-3. REPAIRED PER SRM 53-05, Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700042Floor Panel · damagedMHV - COCKPIT FLOOR AT STATION 142 RBL 17 INCH FROM CENTERLINE EXISTS A HOLE .275 INCH DIAMETER THROUGH SUB STRUCTURE BARRIER FLOOR. REMOVED DAMAGE AREA AND FABRICATED AND INSTALLED NEW PARTS IAW SRM 53-01 FIG 2, 51-30-02. (M)Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700040Floor Panel · crackedMHV - FLOOR PANEL NR 2A HAS SEVERAL SMALL CRACKS AT THE END ROW OF RIVET HOLES. STOP DRILLED HOLE AND ADDED DOUBLER IAW 51-10-3, SRM 51-10-4. (M)Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700039Floor · corrodedMHV - FLOOR WEB HAS CORROSION ON STATION 931-948 RBL 59 ZF1. REMOVED DAMAGE, FABRICATED NEW WEB AND INSTALLED IAW 51-10-2, 51-10-3, 51-30-0. (M)Dec 6, 1996 · N928ML · Doug DC931SDR GTIA9700037Floor Panel · crackedMHV - FLOOR PANEL AFT CABIN HAS TWO CRACKS IN AFT AREA OF SKIN. CUT OUT CRACKS AND FABRICATED FILLER AND DOUBLER PER SRM 51-10-2. ALODINED PER SRM 51-10-3. DRILLED AND COUNTERSUNK PER SRM 51-10-4. INSTALLED FASTENERS PER SRM 51-30-2. FLOOR PANEL REPAIR CODec 3, 1996 · N928ML · Doug DC931SDR GTIA9700027Floor · crackedMHV - FLOOR WEB HAS A 4 INCH CRACK BETWEEN 2 CUTOUTS AT STATION 970 LBL 50. FABRICATED DOUBLERS PER SRM 53-01, FIG 7. INSTALLED IAW SRM 51-10-3. (M)Nov 27, 1996 · N928ML · Doug DC931SDR GTIA9700026Floor · misinstalledMHV - PASSENGER CABIN FLOOR MEMBRANE REQUIRES MODIFICATION PER DOUGLAS REWORK DRAWING SR09530002. MODIFIED FLOOR MEMBRANE PER DOUGLAS DRAWING SR09530002 FS 718-737 AND 737-756 LT AND RIGHT SIDES INBOARD OF FUSELAGE SKIN. (M)Nov 27, 1996 · N928ML · Doug DC931SDR USAA960758Floor Pan · corrosionINT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 3 INCH BY 3 INCH CORRODED AREA BS 1016 LBL 30 FLOOR PAN. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-70-13, FIG 1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)Nov 26, 1996 · N439US · Boeing 7374B7SDR GTIA9700025Floor Board · crackedMHV - FLOOR BOARD, WING BOX AREA, THREE CRACKS IN TOP SKIN AREA, INSULATION TAPE IS LOOSE. CUT OUT CRACKED AREA ON FLOOR BOARD, FABRICATED FILLER AND DOUBLER AND REPAIRED PER SRM 53-05, FIG 1. ALODINED AND PRIMED PER SRM 51-10-3. INSTALLED RIVETS PER SRM 51Nov 26, 1996 · N928ML · Doug DC931SDR GTIA9700023Floor · wornMHV - FLOOR WEB HAS TWO WEAR AREAS 1 INCH LONG OVER 50 PERCENT OF MATERIAL THICKNESS AT STATION 218 LBL 4 AND 7 ZF1. CUT OUT DAMAGE AREA FABRICATED FILLERS AND DOUBLER INSTALLED IAW 53-01, 51-30-2. (M)Nov 26, 1996 · N928ML · Doug DC931SDR GTIA9700022Floor Board · crackedMHV - CABIN FLOOR BOARD HAS A CRACK IN UPPER SKIN. REPAIRED PER SRM 53-05, FIG 1. CUT OUT CRACKED AREA AND FABRICATED FILLER AND DOUBLER. ALODINED AND PRIMED PER SRM 51-10-3. INSTALLED FASTENERS PER SRM 51-30-2. (M)Nov 25, 1996 · N928ML · Doug DC931SDR GTIA9700021Channels · crackedMHV - FLOOR PANEL RIGHT COCKPIT HAS CHANNELS DEFORMED, CRACKED AND WITH RIVETS PULLING THROUGH. REMOVED AND REPLACED CRACKED HAT CHANNEL PER SRM 53-05, FIG 1. FABRICATED REPLACEMENT HAT SECTION. ALODINED AND PRIMED PER SRM 51-10-3. REPLACED FASTENERS PER SNov 25, 1996 · N928ML · Doug DC931SDR GTIA9700020Floor · crackedMHV - COCKPIT FLOOR AREA LEFT STORAGE AREA HAS A CRACK DEVELOPING IN FORWARD TOP EDGE OF RETAINER. FABRICATED AND INSTALLED DOUBLER, CRACK STOP DRILLED IAW 52-01, 51-01, 51-10-03. (M)Nov 24, 1996 · N928ML · Doug DC931SDR GTIA9700018Floor Panel · crackedMHV - FORWARD LAVATORY FLOOR PANEL FS 200 TO 237 HAS SEVERAL FASTENER HOLES WITH CRACKS AND SURFACE CORROSION AROUND SCREW HOLES. REMOVED AND REPLACED SKIN AND DOUBLERS IAW 51-10-0, 51-10-2, 51-10-3, 51-10-4 AND 51-30-3. (M)Nov 22, 1996 · N928ML · Doug DC931SDR CALA9700044Floor · corrodedINSPECTION FOUND NR 2 GALLEY UPPER COMPARTMENT FLOOR CORRODED. THE CORROSION WAS REMOVED, TWO DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-10-1.Nov 22, 1996 · N69735 · Boeing 727224SDR GTIA9700017Floor Panel · delaminatedMHV - RIGHT FLOOR PANEL STATION 699-737 DOUBLER DELAMINATION ON SOME AREA. REATTACHED PER MM 53-20-1. REBONDED FIBERGLASS PER MM 53-20-1. (M)Nov 21, 1996 · N928ML · Doug DC931SDR GTIA9700016Floor · corrodedMHV - SURFACE CORROSION ON FLOOR WEB AT STATION 820-830 RBL 59 ZF1. REMOVED DAMAGE AREA, FABRICATED NEW WEB. INSTALLED IAW 53-05, 51-10-3. (M)Nov 21, 1996 · N928ML · Doug DC931SDR HEEA968496Panel · separationLOWER SIDE OF PANEL HAS SEPARATED COVERS FOR TIE DOWN RING AND SEPARATION ON SLANTED PROTECTIVE COVER OF PANEL.Nov 20, 1996 · N3911L · Bell 412SDR AALA961830Floor Skin · corrodedTUL - CORROSION ON CHORD AND RT AFT LAV FLOOR SKIN, BS 1176.9 RBL 29-32 WL 208.1. REMOVED CORROSION TREATED AND PRIMED AREA PER MM 51-20-0. INSTALLED DOUBLER ON LAV FLOOR SKIN. (M)Nov 20, 1996 · N6818 · Boeing 727223SDR GTIA9700121Floor Panel · corrodedMHV - FORWARD LAV FLOOR PANEL HAS SURFACE CORROSION AND NUMEROUS RIVET HEADS. REMOVED DAMAGED AREA, FABRICATED FILLER AND DOUBLER INSTALLED IAW 51-10-3, 53-05 FIG 1, 51-30-2. (M)Nov 19, 1996 · N928ML · Doug DC931SDR GTIA9700011Floor Panel · crackedMHV - FORWARD CABIN FLOOR PANEL RBL 20 TO 43 FS 200 TO 237 HAS DENT WITH CRACKS AND UNDER SIDE HAS A CRACK ON PANEL STRINGER. REPAIRED FLOOR PANEL IAW SRM 53-01, FIG 2 SRM 53-05 FIG 1, 51-10-03. (M)Nov 15, 1996 · N928ML · Doug DC931SDR GTIA9700009Floor Panel · crackedMHV - FORWARD CABIN FLOOR PANEL INBOARD OF L1 DOOR FS 160 TO 198 HAS A HOLE WITH A CRACK NEXT TO COCKPIT DOOR CUTOUT, LIGHT CORROSION LEVEL 1. FABRICATED REPAIR IAW SRM 51-21-0, FIG 1. REPAIRED PANEL IAW SRM 53-05, 51-10-3. (M)Nov 14, 1996 · N928ML · Doug DC931SDR 97ZZZX1771Floor Panel · corrosionDURING A SCHEDULED INSPECTION AT AERO CORP, CORROSION FOUND ON THE COCKPIT FLOOR CENTER PANEL. REMOVED CENTER COCKPIT FLOOR IAW DC9 SRM 51-30-1, MECHANICALLY REMOVED CORROSION FROM HAT SECTIONS. LESS THAN .001 INCH REMOVED, FOUND WITHIN LIMITS IAW DC9 SRM 51Nov 11, 1996 · N921VV · Doug DC932SDR ABXA9700306Subfloor · crackedDURING C-CHECK, FOUND SUBFLOOR CRACKED AT STA 208 (AD 92-22-08). REPAIRED IAW DC-9 SRM 51-30-2.Nov 6, 1996 · N927AX · Doug DC915SDR ORJA9695Floor Board · corrodedFORWARD LAV FLOOR BOARD INBOARD EDGE CORRODED. CUT OUT DAMAGED AREA AND REPLACED HONEYCOMB IAW SRM 51-90-0, 51-70-2, 51-70-1. REFERENCE AAR N/R 2000-0055. (M)Nov 3, 1996 · N833RA · Doug DC983SDR EIAA9675Floor Panel · corrodedSAT - FORWARD CARGO BAY FLOOR PANEL NR 3 IS CORRODED. REPAIRED FLOOR PANEL PER SRM 51-70-2. (M)Oct 30, 1996 · N935F · Doug DC932FSDR CALA9601581Floor Panel · corrodedINSPECTION FOUND CABIN FLOOR PANEL LOWER SURFACE CORRODED AT STA 1135, RBL 26. THE CORRODED AREA WAS CUT OUT AND A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND 51-40-5.Oct 22, 1996 · N59792 · Boeing 727232SDR TWAA9613009Floor · damagedMCI - DURING OP-16, FOUND HOLE IN CABIN FLOOR MEMBRANE ADJACENT TO LEFT SIDEWALL, FS 1208. INSTALLED REPAIR PER SRM 53-01, APGE 17, FIGURE 4. (M)Oct 14, 1996 · N959U · Doug DC982SDR HEEA968265Floor · mis mfgFLOOR DOES NOT HAVE PROPER JOGGLE ON INBOARD AND FORWARD EDGE OF PANEL AS NEEDED TO GO BELOW (-051) LARGE FLOOR.Oct 14, 1996 · Skrsky S76ASDR CALA9601639Floor · corrodedINSPECTION FOUND RT AFT LAV FLOOR AREA CORRODED IN SEVERAL PLACES. THE CORRODED AREAS WERE CUT OUT, FILLERS AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-40-2.Oct 10, 1996 · N59792 · Boeing 727232
Back to JASC 5321