JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL72S960129Floor Pan · crackedFOUND ON MV1 CHECK, LT AND RT LAV FLOOR PAN DITCHING SEAL PANEL CRACKED, VIEWED FROM BAG BIN FWD OF 1183. REPAIRED PER M/M 53-0-11.SDR CAL960139Floor · corrodedSTATION 31J - INSPECTION FOUND FORWARD LAV FLOOR PANEL CORRODED. A NEW WEB SECTION AND L-ANGLE REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2, 51-10-1, 51-10-2, AND 51-40-3. (M)SDR 96ZZZM300Floor · corrodedLEVEL 2 EXFOLIATING CORROSION UNDER STAINLESS STEEL PLATE AT STA 1130-1148, RBL 26 AT RIGHT AFT LAV. FABRICATED DOUBLER AND FILLER, LOCATED AND DRILLED AND INSTALLED COMPLETE PER SRM 51-10-6, 51-40-2 AND TREATED. (M)SDR HEEA966354Panel · wrong studSTUD P/N 120-064-3HN WAS INSTALLED IN WRONG POSITION. HAD TO REMOVE IT TO MAKE REPAIR TO STYROFOAM AND INSTALL PROPER STUD P/N 120-142-1. REMOVED PANEL AND MADE HOLE IN STYROFOAM. REMOVED STUD AND INSTALLED SERVICEABLE STUD. REPAIRED HOLE AND REINSTALLED PANSDR 96ZZZM304Floor · corrosionLEVEL 2 EXFOLIATING CORROSION, STATION 600-640 RBL 64, UPPER HORIZONTAL SURFACE, OUTBOARD FLOOR STABILIZER. REMOVED CORROSION AND TREATED AND PRIMED PER SRM 51-10-6, 51-10-2. (M)SDR 96ZZZM146Floor · corrodedLEVEL 2 CORROSION, CABIN FLOOR AT STATION 1260R TO 1280R CUSP HAS CORROSION. REMOVED DAMAGED AREA, INSTALLED NEW FITTING (P/N 464016501N) PER SRM 53-1-0. (M)SDR AALA952159Deck Plate · corrodedAFW - FOUND DECK PLATE HAS CORROSION REMOVED ON UPPER SURFACES AT VARIOUS LOCATIONS. CORROSION REMOVED IS BEYOND SRM LIMITS. PER MRB 757-677. (M)SDR 96ZZZX1187Floor · corrodedLEVEL 2 CORROSION, CABIN FLOOR STA 1338, LT SIDE AFT OF EMERGENCY CIRCUMFERENTIALS, FRAMES AND CUSP HAVE CORROSION. REMOVED DAMAGED AREA, AND FABRICATED AND INSTALLED REPAIR PER RIA DRAWING 45931-2.SDR 96ZZZM237Floor Panel · corrodedMCI - DURING OP-16, FOUND CABIN FLOOR PANEL CORROSION, STATION 1305 TO STATION 1309. REPLACED FLOOR PAN PER SRM 51-10-01.SDR ABXA9600216Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13795-MR.SDR ABXA9600215Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13795-MR.SDR ABXA9600214Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13795-MR.SDR ABXA9600212Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND FLOOR PANEL CORRODED AT STA 180 TO 237. REPAIRED IAW ABX REA D953-13784-MR.SDR ABXA9600211Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND FLOOR PANEL CORRODED AT STA 180 TO 237. REPAIRED IAW ABX REA D953-13784-MR.SDR ABXA9600210Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND FLOOR PANEL CORRODED AT STA 180 TO 237. REPAIRED IAW ABX REA D953-13784-MR.SDR ABXA9600219Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13796-MR.SDR ABXA9600218Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13796-MR.SDR ABXA9600217Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 180 - STA 237. REPAIRED IAW ABX REA D953-13796-MR.SDR ABXA9600201Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORROSION ON THE FLOOR PANELS AT RBL 8.5 TO 22 STA 237 AND 256, LBL 0 TO 16.25 STA 237 AND 294. REPAIRED IAW ABX REA D953-13739-MR.SDR ABXA9600200Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORROSION ON THE FLOOR PANELS AT RBL 8.5 TO 22, STA 237 AND 256, LBL 0 TO 16.25 STA 237 AND 294. REPAIRED IAW ABX REA D953-13739-MR.SDR ABXA9600199Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORROSION ON THE FLOOR PANELS AT RBL 8.5 TO 22 STA 237 AND 256, LBL 0 TO 16.25 STA 237 AND 294. REPAIRED IAW ABX REA D953-13739-MR.SDR ABXA9600198Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORROSION ON THE FLOOR PANELS AT RBL 8.5 TO 22 STA 237 AND 256, LBL 0 TO 16.25 STA 237 AND 294. REPAIRED IAW ABX REA D953-13739-MR.SDR GTIA96NK111Floor · corrodedDURING C-CHECK, FOUND PAX CABIN AT Y237 TO X50 FLOOR OUTBOARD MEMBRANE CORRODED, FOUND DURING FORWARD TOILET FLOOR PANEL. REPLACED SHEET IAW SRM 51-01 PARA C. REPLACED RIVETS IAW SRM 51-30-2. (M)SDR ABXA9600209Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANELS AT STA 160. REPAIRED IAW ABX REA D953-13783-MR.SDR ABXA9600208Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANELS AT STA 160. REPAIRED IAW ABX REA D953-13783-MR.SDR ABXA9600207Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND CORRODED FLOOR PANEL AT STA 160. REPAIRED IAW ABX REA D953-13783-MR.SDR ABXA9600205Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND FLOOR PANEL CORRODED AT STA 193. REPAIRED IAW ABX REA D953-13771-MR.SDR ABXA9600204Floor Panel · corrodedDURING C-CHECK INSPECTION, FOUND FLOOR PANEL CORRODED AT STA 193. REPAIRED IAW ABX REA D953-13771-MR.SDR GTIA96NK110Floor · corrodedDURING C-CHECK, FOUND PAX CABIN BETWEEN Y200 TO Y210 AND FROM XX23 TO XX49 PANEL CORRODED. LOCATED UNDER FLOOR PANEL. REPLACED SHEET UNDER FLOOR PANEL IAW SRM 51-0 PARA C. REPLACED RIVETS IAW SRM 51-30-2. (M)SDR EISA95446Floor · corrodedCORROSION AT FORWARD LAV FLOOR PANEL BETWEEN STATION 290-300. REMOVED BAD PART OF FLOOR, FABRICATED NEW PIECE AND DOUBLER PER SRM 57-10-6. INSTALLED FABRICATED PANEL AND DOUBLER PER SRM 51-10-1.SDR DL73E954677Floor Panel · corrodedAT HMV INSPECTION, FOUND THE FORWARD B/B LT FIXED FLOOR PANEL CORRODED AT STA 500-520. CORRECTION: REMOVED FIXED FLOOR. REPLACED FIXED FLOOR. INSTALLED FIXED FLOOR PANEL.SDR AWXA9500794Floor · corrodedPHX - DURING SCHEDULED C4 INSPECTION, FOUND AFT GALLEY FLOOR PAN CORRODED IN NUMEROUS AREAS FROM STATION 1681.8 THROUGH STATION 1740, RBL 2 THROUGH LBL 55. REPAIRED PER ER 5-53-16-11. (M)SDR AWXA9500793Floor · corrodedPHX - DURING SCHEDULED C4 INSPECTION, FOUND FLOOR PAN AT BS 1691 TO BS 1710 LBL 55 CORRODED. INSTALLED REPAIR IAW ER 5-53-16-11. (M)SDR CAL951166Floor · corrodedINSPECTION FOUND CORROSION ON LEFT SIDE OF FLOOR IN AFT LAV AT DUMP TUBE. THE CORRODED AREA WAS CUT OUT. A DOUBLER AND FILLER REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2, 51-10-2, 51-30-2, AND MM 51-20-0. (M)SDR GTIA96NK078Floor · corrodedDURING C-CHECK, FOUND E/E COMPARTMENT PAX CABIN FLOOR PANEL WITH CORROSION AT Y197 AND X20. REPLACED SHEET IN FLOOR PANEL IAW SRM 51-01 PARA C. REPLACED RIVETS IAW SRM 51-70-2. (M)SDR 95ZZZX6921Floor Pan · crackedCOPILOT INBOARD SEAT RAIL AFT END, STA 27.02 TO STA 56.69, FOUND FLOORBOARD CRACKED AT AFT END OF INBOARD SEAT RAIL (COPILOT SIDE). THE CRACK WAS 2 INCHES IN LENGTH AND CORRESPONDED DIRECTLY WITH THE AFT END OF THE SEAT RAIL. THE FLOOR BEGINS TO CONTOUR UPWASDR AALA952007Deck · corrodedAFW - DECK PLATE HAD CORROSION BLENDED BEYOND SRM LIMITS. PER MRB 757-651. (M)SDR CAL951096Floor Panel · corrodedTHE RIGHT FLOOR SUPPORT PANEL WAS FOUND CORRODED IN THE AFT CARGO COMPARTMENT AT BS 950-950F. THE FLOOR SUPPORT PANEL WAS REMOVED. A NEW FLOOR SUPPORT PANEL WAS FABRICATED AND INSTALLED IAW SRM 51-40-2, 51-10-6, AND 51-10-2. (M)SDR 96ZZZX105Panel · corrodedWHILE PERFORMING A SHEET METAL INSPECTION, FOUND SKIN CORRODED AND SEPARATED AROUND PERIMETER OF RT FORWARD FLOOR PANEL. INADEQUATE (PRO-SEAL) AROUND PERIMETER OF PANEL.SDR 95ZZZX6474Panel · corrodedFLOOR PANEL RECEIVED WITH TWO UPPER SKINS OF .020 INCH EACH. SB REQUIRED SKIN OF .020 INCH PANEL. SHOWS HEAVY CORROSION. PART PREVIOUSLY OVERHAULED BY ANOTHER REPAIR STATION.SDR ORJA95114Floor Panel · puncturedMETAL FLOOR PANEL PUNCTURED AND DEFORMED WITH CORROSION AFT PIT FLOOR PLATE. REPAIRED 2 PUNCTURED AND DEFORMED AREAS ON AFT PIT FLOOR PLATE. INSTALLATION OF DOUBLER AT EACH LOCATION USING MATERIAL OF SAME THICKNESS. INSTALLED PER REF DC9 SRM 53-01 PAGE 17 ASDR AALA951855Deck Plate · corrodedAFW - DECK PLATE, AT STATION 1681 AND 1720, HAS CORROSION REMOVED AT VARIOUS BL LOCATIONS BEYOND SRM LIMITS. PER MRB 757-637. (M)SDR 95ZZZX6757Floor Panel · crackedDURING 100-HOUR INSPECTION, COPILOT'S INBOARD SEAT TRACK AFT FLOOR AREA, FOUND 2 INCH CRACK. CRACK AT RADIUS COMES UP OVER MAIN LANDING GEAR ATTACH BOXES. SUSPECT CAUSE, SEAT TRACK TOO LONG ENDING IN THE START OF THE RADIUS. SUGGEST BEVEL SEAT TRACK TO PREVSDR USAA951147Floor Pan · corrosionINT - DURING 'Q-3' CHECK, VISUAL INSPECTION FOUND 1 INCH BY 1 INCH CORROSION ON FLOOR PAN, SEVERAL SPOTS, STA 1038, LBL 8. FABRICATED AND INSTALLED NEW FLOOR PAN. REPAIRED PER DRAWING 65C33419, SRM 53-60-51. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2.SDR 95FDEA1568Cargo Floor · crackedAFT CARGO FLOOR CRACK IN FRAME AROUND TOOLING HOLE STA 1090, JUST ABOUT STR 27 LT (NR 1020). FABRICATED FRAME REPAIR PER SRM 51-40-3, DOUBLER INSTALLED.SDR AALA951851Deck Plate · corrodedAFW - SEVERAL AREAS OF DECK PLATE HAS CORROSION BEYOND SRM LIMITS. PER MRB 757-619. (M)SDR AALA951911Deck Plate · corrodedAFW - DECK PLATE HAS CORROSION BLENDED BEYOND SRM LIMITS. CYCLES, 5,937. (X)SDR UPS204596Floor · crackedWHILE IN FOR SI CHECK, MAINTENANCE FOUND UPON REMOVAL OF LT AND RT DOGHOUSE FLOORS, BOTH LT AND RT HAND FLOORS HAVE NUMEROUS CRACKS. INSTALLED FABRICATED FLOOR REPAIRS PER SRM 51-20-1, 51-40-2, 51-30-2.SDR 96ZZZX1853Floor · damagedDURING C- AND D-CHECKS, FOUND E AND E COMPARTMENT, CABIN FLOOR AREA JUST ABOVE SERVO DRIVE UNIT CORRODED. REPAIRED IAW DC9 SRM CH 53. AIRCRAFT TT: 51,653. AIRCRAFT TC: 57,610.SDR 95ZZZX5972Floor Skin · delaminatingWHILE PRESSURIZING AIRCRAFT FOR 1,200 HOUR INSPECTION, AIRCRAFT WOULD NOT MAKE ALLOWABLE LEAK RATE. FOUND LOWER SKIN OF DIVAN SEAT FLOOR SITTING ON TOP OF WING SKIN WITH AIRCRAFT PRESSURIZED. FOUND UPPER AND LOWER DIVAN SEAT SKIN SEPARATING FROM THE HONEYCOM
Back to JASC 5321