JASC 5340
Service difficulty reports · 22,411
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0410432Web · corrodedPAE - CORROSION ON THRESHOLD WEB AFT GALLEY DOOR CUT OUT. REMOVED AND REPLACED WEB.SDR COOSDR040045Fitting · crackedFWD CARGO COMPARTMENT FROM Y-STA 440 TO Y-STA 460, LONGERON 31R SPLICE FITTING, PN 3750257-1, CRACKED. (K)SDR COOSDR040049Fitting · crackedMAIN CARGO CABIN, FROM Y STA 650 TO Y-STA 680, LONGERON 1 FITTING WITH CRACK. (K)SDR USAA040893Stringer Clip · crackedPIT- Q5- STRINGER TIE CLIP, .2500 INCH CRACK, BS 344, STR8, RT. FABRICATED IAW MFG DWG 66-244553 AND INSTALLED IAW SRM 51-40-01.SDR USAA040892Stringer Clip · crackedPIT- Q5- STRINGER TIE CLIP, 1.25 INCH CRACK, BS 360, STR 4, RT. DEFECTIVE PART REPLACED WITH IDENT PART NR IAW SRM 51-10-02.SDR WLDA2004118Support Fitting · corrodedDURING 2C+12A CHECK, FOUND CORROSION IN CENTER WING W/W RT/LT SUPPORT FITTING AT STA Y=1481 X=-31.5 AND X=31.5. REPAIRED CORROSION ON LT/RT FWD TRUNNION FITTING BOOT STRAP OF CENTER MLG PER EGAT EI W2004A53B-590 REV.00 (FAA 8110-3 FORM DATED OCT/04/2004). CONSDR USAA040878Attach Bracket · crackedATTACH BRACKET, .5 INCH LONG CRACK, S10L, STA 360. MANUFACTURED ATTACH BRACKET IAW SRM 51-40-03.SDR AWXA200401172Stringer Clip · crackedDURING C-18 CHECK A .3750 INCH CRACK WAS FOUND IN STRINGER CLIP AT BS 294, STR 11 LT. MAINTENANCE REMOVED CRACKED STRINGER CLIP AT BS 294, STR 11 LT; FABRICATED A NEW REPLACEMENT CLIP; INSTALLED REPAIR PART IAW ER 03-5311-04295-ES1.SDR USAA040735Stringer Clip · corrodedSTRINGER TIE CLIP, 2 INCH SQUARE, CORROSION, STA 1420 LOWER FLANGE OF FRAME ABOVE STR 28R. REPLACED WITH FABRICATED PARTS IAW SRM 51-10-02.SDR IXXA0500067SFitting · corrodedDURING A ROUTINE C-CHECK INSPECTION FOUND RT FUSELAGE LONGERON 24 FITTING FRAME HAS CORROSION DAMAGE ON LOWER SIDE AT STA 960.000. REPAIR ACCOMPLISHED REMOVAL OF THE CORRODED AREA AND FOUND OUT OF LIMITS. FABRICATED NEW FITTING. FABRICATED SPLICES, DOUBLER SDR IXXA0500057SFitting · damagedDURING A ROUTINE C CHECK INSPECTION, LT FUSELAGE LONGERON 24 FITTINGS FRAME REMOVED AND INSTALLED FOR NR 3484 AT STA 940.000. REPAIR ACCOMPLISHED REMOVAL OF FITTING IN ORDER TO GAIN ACCESS FOR REPAIR. FABRICATED SPLICES, DOUBLER AND FILLERS. HEAT TREATED DOSDR AWXA200401182Stringer Clip · crackedDURING C-18 CHECK, A 3/8 INCH CRACK WAS FOUND IN FRAME TO STRINGER ATTACH CLIP AT BS 348, STR 15 LT. MAINTENANCE REMOVED DAMAGED FRAME ATTACH CLIP AT BS 348, STR 15 LT; FABRICATED A NEW REPLACEMENT CLIP PER DWG 69-16970; INSTALLED REPAIR PART IAW ER 03-5312-0SDR 2004UALA00928Stringer Clip · crackedTWO EA STRINGER CLIPS ARE CRACKED AT STA 460 STR 6 LT AND STA 420 STR 4 LT. MAJOR REPAIR ACCOMPLISHED. REPLACED BOTH STRINGER CLIPS.SDR 04FDEA02917Fitting · crackedCRACKED LONGERON END FITTING, AFT OF RIGHT HAND AIR CONDITIONING DOOR CUTOUT, LONGERON 35R, STA 535. REMOVED END FITTING IAW FEDEX SRM 51-35-01 VOLUME II PAGE 1, AREA ALODINED AND TREATED IAW FEDEX DC10 SRM 51-21-01 VOLUME II PAGE 1, RECEIVED NEW END FITTING SDR IXXA0500211SAttach Fitting · crackedDURING ROUTINE C-CHECK FOUND LONGERON ATTACH FITTING CRACKED AT STATION 1690 LONGERON 23 RIGHT. REMOVED DAMAGED FITTING, FABRICATED NEW FITTING. LOCATED, DRILLED, TREATED, PRIMED AND INSTALLED NEW LONGERON ATTACH FITTING IAW DC8 MM 20-16-0, DC8 SRM 51-3-1, 5SDR ASA0440179Stringer Clip · crackedOKC - CRACKED STRINGER CLIP. REMOVED AND REPLACED STRINGER CLIP.SDR AWXA200401183Stringer Clip · crackedDURING C-18 CHECK, A 5/16 INCH CRACK WAS FOUND IN FRAME TO STRINGER ATTACH CLIP AT BS 360, STR 11 LT. MAINTENANCE REMOVED DAMAGED FRAME ATTACH CLIP AT BS 360, STR 11 LT; FABRICATED A NEW REPLACEMENT CLIP PER DWG 69-48985; INSTALLED REPAIR PART IAW ER 03-5312-SDR IXXA060045SAttach Fitting · corrodedDURING ROUTINE C-CHECK FOUND MAIN CARGO CABIN SUPPORT END FITTING CORRODED AT STATION Y55 -X65 Z0. REMOVED FASTENERS AS NEEDED TO REMOVE END FITTING. MANUFACTURED NEW END FITTING, LOCATED, DRILLED, TREATED, PRIMED, INSTALLED NEW END FITTING AND FASTENERS AT STSDR IXXA060042SFitting · crackedDURING ROUTINE C CHECK FOUND LONGERON 1 FITTING CRACKED AT STATION 650. REMOVED FASTENERS AS NEEDED TO REMOVE DAMAGED FITTING. MANUFACTURED NEW FITTING, LOCATED DRILLED TREATED, PRIMED, INSTALLED FITTING AND FASTENERS WET WITH SEALANT AT LONGERON 1 STATION 65SDR ASOA04804Bushing · migratedDURING DESCENT, AT APPROX 24,000 FT THE CREW HEARD A LOUD (BANG) FROM UNDER THE RT WING ROOT. ALL INDICATIONS WERE NORMAL INCLUDING THE FLIGHT CONTROLS AND DOORS. AN EMERGENCY WAS DECLARED WITH A NORMAL APPROACH AND LANDING ACCOMPLISHED WITHOUT FURTHER INCIDSDR ASA0440168Stringer Clip · crackedPAE - STRINGER CLIP CRACKED. REMOVED AND REPLACED STRINGER CLIP.SDR UPS04243394Fitting · corrodedINSPECTION TYPE:C DURING REMOVAL OF RIGHT 740 FITTING CORROSION FOUND ON CENTER WING SECTION FRONT SPAR UPPER CHORD AT RBBL 65-70 APPROX CORROSION REMOVED IAW SRM 51-10-06. REPAIR ANGLES FABRICATED IAW SRM 53-30-03. HFEC CARRIED OUT ON ABOVE AREA IAW B727-NDSDR SWIA200413964Stringer Clip · crackedCLIP AT FS 202.75 AND LEFT STRINGER 21 CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIP IAW CRJ SRM 51-40-11, 51-42-06, AND 51-23-00.SDR 0401855518Fitting · crackedDURING H-CHECK FOUND CRACK IN FITTING ON AFT SIDE OF FRAME AT BS 1681 S13R. REPAIRED PER EA 55-201106.SDR UPS04243403Terminal · crackedINSPECTION TYPE: C, TAIL SKID BAY STABILIZING LINKS UPPER AND LOWER LEFT AFT TERMINALS CRACKED AND LOWER AFT RIGHT TERMINAL CRACKED. INSTALLED NEW UPPER AND LOWER LEFT AFT TERMINALS ON TAILSKID BAY, FABRICATED LOWER AFT RIGHT TERMINAL AND FITTED IAW SRM 51-30SDR 371PA0084Attach Fitting · crackedHFEC INSPECTION OF PREVIOUS REPAIR INDICATES A CRACK AT THE BS 616 STUB BEAM TO LONGITUDINAL FLOORBEAM ATTACH POINT AT LBL 45.5. FURTHER INVESTIGATION DETERMINED THAT THE DAMAGE TO BE A PREVIOUS PLUG INSTALLED IN THE FASTENER HOLE. REPAIRED AREA IAW MFG MESSSDR ASAA0410422Angle · corrodedPAE - CORROSION ON UPPER FLANGE OF L-ANGLE. REMOVED CORROSION IN AN AREA 1 INCH X 20 INCHES. REMOVING .075 INCHES FROM AN ORIGINAL .200 INCHES, FOUND TO BE OUT OF LIMITS. REPAIRED IAW EA.SDR ASA0440175Stringer Clip · crackedPAE - CRACKED STRINGER CLIP AT FASTENER. REMOVED AND REPLACED STRINGER SPLICE AND CLIP.SDR ASA0440174Stringer Clip · crackedPAE - CRACKED STRINGER CLIP. REMOVED AND REPLACED STRINGER CLIP.SDR ASA0440173Stringer Clip · crackedPAE - CRACKED STRINGER CLIP. REMOVED AND REPLACED STRINGER CLIP.SDR ASA0440172Stringer Clip · bentPAE - AFT CARGO BAY STRINGER CLIP BENT. REMOVED AND REPLACED STRINGER CLIP.SDR LR7A04109Fitting · crackedDURING SCHEDULED C6 INSPECTION IAW JOB CARD HC5323 FOUND LMLG FS 617 AFT FAIRING TENSION TIE FITTING CRACKED AT WL 158, LBL 68. REPLACED FITTING IAW DWG 339394 AND SRM SMP 51-70. NR 0283.SDR AWXA200401125Stringer Clip · corrodedDURING C-18 CHECK, EXFOLIATION CORROSION WAS FOUND ON STRINGER CLIP FORWARD OF BS 967, STR 25 RT. MAINTENANCE REMOVED DAMAGED STRINGER CLIP AT BS 967, STR 25 RT; FABRICATED A NEW REPLACEMENT STRINGER CLIP; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02, FIG SDR ASAA0440165Stringer Clip · crackedCRACKED STRINGER CLIP. REMOVED AND REPLACED CRACKED STRINGER CLIP. (REV 1)SDR USAA0480517Fitting · corrodedOKC - C-CHECK, AFT BILLIE BATH TUB FITTING TO BULKHEAD STA 1003, LONG 30, HAS AREAS OF CORROSION ON FORWARD INSIDE OF FITTING. REMOVED DAMAGE, SPOT FACED FASTENER HOLES, TREATED AND PRIMED, SEALED AND APPLIED CORROSION INHIBITING COMPOUND IAW EA 5340-01132 ANSDR SWIA200413907Attach Fitting · crackedFUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIPS ARE CRACKED IB AND OB; FS 280.00 RBL 9.0. (ITEM FOUND AT C-CHECK INSPECTION.) CLIPS REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-23-00, 51-42-21, 51-42-13, 51-21-11 AND 51-25-16.SDR SWIA200413906Attach Fitting · crackedFUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIPS ARE CRACKED IB AND OB; FS 280.00 LBL 9.0. ITEM FOUND AT C-CHECK INSPECTION. CLIPS REPLACED IAW CRJ SRM 51-40-11, 51-23-00, 51-42-06, 51-42-21, 51-42-13, 51-21-11, 51-25-16.SDR DHL2004801556Fitting · crackedITEM REF. NR. 0988: AFT ACCY COMPARTMENT FLOORBEAM CEILING FITTING CRACKED 0.500 AT STA. 660.000. REMOVED CRACKED FITTING IAW SRM 51-3-0 PG.1. SRM 51-1-21 PG.1. FABRICATED NEW FITTING (AL7075-T7351) IAW DWG 4333996. PERFORMED NDT INSPECTION IAW NDT SPM PART 0SDR DHL2004801544Fitting · crackedAFT CARGO COMPT STOP FITTING CRACKED 1.000, STA 1240.000, L-24L TO L-27L. REMOVED CRACKED FITTING IAW DC8 SRM 51-1-21 PG 1, DC8 SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW DC8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC8 SRM 51-1-21 PG 1, DC8 SRMSDR DHL2004801557Fitting · crackedAFT ACCY COMPT SPLICE FITTING HAS CRACKS 1.000, 0.500 STA. 640.000 TO STA. 660.000, L-32R. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 PG.1, DWG 5800471. REMOVED CRACKED SPLICE FITTING IAW SRM 51-1-20D PG. 21. FABRICATED SPLICE FITTING (AL7075-T651) IAW DWG 580047SDR ASAA0440166Stringer Clip · wornLOOSE STRINGER CLIP. REMOVED AND REPLACED LOOSE STRINGER CLIP.SDR SWAA042794Stringer Clip · crackedDURING SCHEDULED 1/4D CHECK, FOUND STRINGER TIE CLIP AT BS 706, STRINGER 1L, CRACKED. REMOVED AND REPLACED STRINGER TIE CLIP PER SRM.SDR SWAA042791Fitting · crackedDURING SCHEDULED C4 CHECK, FOUND FWD ENTRY DOOR UPPER AND LOWER HINGE BOX FITTINGS CRACKED. REMOVED AND REPLACED UPPER AND LOWER HINGE BOX FITTINGS PER SRM.SDR SWIA200414274Attach Angle · crackedMAIN CABIN FLOORBEAM ATTACH ANGLE AT FS 461 RBL IS CRACKED AT RADIUS LOCATION. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED NEW ANGLE BRACKET AND SPLICE IAW REO 601R-53-61-004.SDR SWIA200414257Attach Angle · crackedMAIN CABIN FLOORBEAM ATTACH ANGLE AT FS 461 RBL 10 IS CRACKED AT RADIUS LOCATION. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED NEW ANGLE IAW CRJ 200 SRM 51-42-21 AND EO NR 601R-53-5459.SDR DHL2004801541Fitting · crackedUPPER CUSP EXTRUSION FITTING CRACKED 1.000, STA 857.000 L-19R. REMOVED CRACKED FITTING IAW DC8 SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW DC8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D PG 9.SDR USAA040677Anchor Fitting · corrodedANCHOR FITTINGS; CORROSION; LEVEL 1; TASK NR C53-107-02, ANCHOR FITTINGS AT STA 993R. REPLACED FITTINGS IAW SRM 51-10-2.SDR UPS04843371Fitting · crackedINSPECTION TYPE: C, MAIN CARGO FS 781 RBL 62 BOOT FITTING CRACKED AT RADIUS FWD AND AFT SIDES BELOW FLOORLINE. REMOVED BOOT FITTING AT FS 781 RBL 62 IAW SRM 51-1-21. FABRICATED BOOT FITTING IAW SAA SK 729-576. INSTALLED BOOT FITTING IAW SRM 51-1-20D & 51-1-SDR UPS04843363Fitting · crackedINSPECTION TYPE-C, CRACKED FITTING IN MAIN CABIN SUBFLOOR, STA 978-980 IN CORNER, LBL 66. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR ABXA040336Fitting · crackedEND FITTING AT LONGERON 29 RT ON AFT SIDE OF STA. 604 WAS CRACKED. REMOVED AND REPLACED END FITTING AT LONGERON 29 RT, STA. 604 IAW SRM 51-30-5.
Back to JASC 5340