JASC 5340
Service difficulty reports · 22,411
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA040337Fitting · crackedEND FITTING ANGLES ON AFT SIDE OF STA. 604, BUTT LINE 0, ARE CRACKED AND CORRODED. REMOVED AND REPLACED END FITTING ANGLES ON AFT SIDE OF STA. 604, BUTT LINE 0 IAW SRM 51-30-5. PN: 3924029-2N AND 3924029-1N.SDR UPS04243273Fitting · crackedINSPECTION TYPE:C, SUSPECT CRACK FROM LT TERMINAL FITTING FOR STABILIZING LINK LWR IN TAIL SKID COMPARTMENT. INSTALLED NEW TERMINAL FITTING IAW SRM 51-30-02.SDR UPS04243272Fitting · crackedINSPECTION TYPE:C, SUSPECT CRACK FROM RIGHT TERMINAL FITTING FOR STABILIZING LINK LWR IN TA TAIL SKID COMPARTMENT. INSTALLED NEW TERMINAL FITTING IAW SRM 51-30-02.SDR 04FDEA02765Fitting · corrodedTHE FOLLOWING FWD CARGO COMPT FWD MANHOLE POCKETS HAD CORROSION AT LOCATIONS: (A) AFT OF FS 23 RT SIDE CTR PORTION 2 OFF POCKETS BETWEEN STR 51 RT AND STR 49RT. REPAIR C/W AS PER EA 6-310-77945 AND ALSO REFER TO N00411 AND N00412. RII BY L3167(SIAEC) Y: 275SDR KNN2008F00003Stringer Clip · damagedWHILE COMPLYING WITH AD 93-08-04 AND SB 737-53-1268. DURING THE CURRENT C-CHECK. WE FOUND STRINGER CLIP THAT FAILED NDT INSPECTION. THE STRINGER CLIP WAS REPLACED IAW SB-737-53-1268. ALL SUPPLEMENTAL INSPECTIONS WERE ALSO COMPLIED WITH IAW THE SB. (K)SDR UPS04843247Fitting · crackedINSPECTION TYPE:C1, LONGERON 5R END FITTING CRACKED STA 850. REMOVED AND REPLACED FITTING IAW SRM 51-1-21-1-200.SDR USAA040625Attach Angle · corrodedPIT - FOUND ATTACH ANGLE CORRODED THREE AREAS, APPROX 1.5 INCH BY 6 INCHES, STATION 947 FROM RT ZEE ANGLE TO LEFT ZEE ANGLE. MANUFACTURED AND INSTALLED NEW ANGLE PER SRM 51-40-02. (M)SDR USAA040623Stringer Clip · crackedPIT - FOUND CLIP CRACKED .5 INCH, STRINGER CLIP, CABIN OVERHEAD BS 601 S6L. INSTALLED NEW CLIP PER SRM 51-40-00. (M)SDR USAA040682Fitting · crackedPIT - FOUND STRINGER END FITTING CRACKED .25 INCH, STRINGER 15L AFT OF STATION 360. INSTALLED NEW PART PER BOEING DWG 65-17685 ND SRM 51-40-02, 51-10-02, 51-40-03. (M)SDR SWAA042704Stringer Clip · crackedDURING SCHEDULED 1/4D CHECK, FOUND 2 EACH STRINGER CLIPS AT BS 500B, STRINGER 25L AND BS 500C, STRINGER 25L, CRACKED. REMOVED AND REPLACED STRINGER CLIPS PER SRM.SDR SWAA042693Stringer Clip · crackedDURING SCHEDULED D-CHECK, FOUND STRINGER CLIP AT BS 706, STRINGER 11R, CRACKED. REMOVED AND REPLACED STRINGER CLIP PER SRM.SDR SWAA042668Stringer Clip · crackedDURING SCHEDULED D-CHECK, FOUND STRINGER CLIP AT BS 277, STRINGER 15R, CRACKED. REMOVED AND REPLACED STRINGER CLIP PER SRM.SDR SWIA200413842Attach Fitting · crackedFUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIPS ARE CRACKED; FS 280.00, RBL 9.0 INBOARD AND OUTBOARD. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIPS IAW CRJ SRM 51-40-11, 51-23-00, 51-42-06, 51-42-21, 51-25-16, AND 51-21-11.SDR UPS04843304Fitting · corrodedINSPECTION TYPE: C3, BS 1220.00 & L34R BATHTUB FITTING HAS CORROSION. REMOVED AND REPLACED FITTING IAW DC-8 SRM 53-2-0 FIG 2G.SDR SWAA042625Stringer Clip · crackedDURING SCHEDULED D CHECK, FOUND STRINGER CLIP AT BS 727D, STRINGER 4L, CRACKED. REMOVED AND REPLACED STRINGER CLIP PER SRM.SDR SWAA042605Stringer Clip · crackedDURING SCHEDULED D CHECK, FOUND STRINGER CLIP AT BS 685, STRINGER 2L, CRACKED. REMOVED AND REPLACED STRINGER CLIPS PER SRM.SDR CALA0400630Fitting · corrodedINSPECTION FOUND FORWARD CARGO DOOR SILL MOUNT FITTINGS NR 1, 2, 3, 4 & 5 CORRODED. THE CARGO DOOR SILL FITTINGS WERE REPLACED IAW SRM 51-40-02.SDR ASAA0410389Stringer Clip · damagedPAE - FOUND STRINGER HAS MECHANICAL DAMAGE TO STRINGER CLIP. REMOVED DAMAGED STRINGER CLIP, FABRICATED NEW STRINGER CLIP AND INSTALLED. (M)SDR USAA040720Stringer Clip · crackedCLIP, 1 INCH CRACK, FRAME TO LONGERON CLIP INTERIOR FUSELAGE, STA 344, STR 11R. MFG AND INSTALLED REPLACEMENT CLIP IAW MFG DWG 69-38939.SDR USAA040663Angle · crackedPIT - FOUND ANGLE CRACKED 2 INCHES, RT WING ROOT, BS 540 AT S22R. REPLACED CREASE BEAM SECTION PER SRM 51-40-00. (M)SDR 2004FA0000824Fitting · detachedDURING COMPLIANCE WITH SEB88-3 TO REPLACE FORWARD STABILIZER ATTACH FITTINGS PN 0732601-5, IT WAS DISCOVERED THAT THE TOP TWO RIVETS OF BOTH FITTINGS HAD FAILED LEAVING ONLY THE THREE RIVETS IN THE LOWER PORTION OF EACH FITTING. ALL FOUR RIVETS FAILED IN BETWSDR SWIA200414422Stringer Clip · crackedON 625 BULKHEAD STRINGER 13L AND 13R CLIP CRACKED. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED 2 REPLACEMENT BRACKETS PER RJ200 SRM 51-42-21 PG 13.SDR IXXA0500043SFitting · damagedDURING A ROUTINE C CHECK INSPECTION, REMOVED MAIN CARGO COMPT FRAME FITTING AT STA920.00 L-23L TO L24L IN ORDER TO COMPLY WITH N/R 3484. REPAIR ACCOMPLISHED. REMOVED FITTING TO GAIN ACCESS TO STRUCTURAL REPAIR. FRABRICATED SPLICES, DOUBLER AND FILLERS. CLEASDR UPS04843164Fitting · crackedINSPECTION TYPE: C2, LONGERON 32R SPLICE FITTING CRACKED FROM STA 620 TO STA 640. REMOVED AND REPLACED SPLICE FITTING PER SRM 51-1-20D.SDR 04FDEA02588Fitting · crackedCAC COMPARTMENT, BETWEEN STA Y= 6-90 AND STA Y= 6-100 LONGERON 43R END SPLICE FITTING FOUND CRACKED. CAC COMPARTMENT - STA Y= 6-90 AND STA Y= 6-100 CRACKED SPLICE AT LONGERON 43R. REMOVED PER SRM 51-31-01 VOLUME II. NEW SPLICE FITTING FABRICATED PER DWG AGSDR IXXA0500034SFitting · corrodedDURING A ROUTINE C CHECK INSPECTION, FOUND FUSELAGE AT SECTION FITTING CORROSION DAMAGE BETWEEN STA 1680.00 AND 1690.00, L-36. REPAIR ACCOMPLISHED, REMOVED CORRODED FITTING AND THE CORROSION. FOUND OUT OF LIMITS. CLEANED, TREATED AND PRIMED AREA AND INSTALLSDR ASAA0410385Stringer Clip · corrodedFOUND CORROSION ON STRINGER CLIP. BLENDED CORROSION, FOUND OUT OF LIMITS, FABRICATED AND INSTALLED. (M)SDR UPS04843166Fitting · crackedINSPECTION TYPE: C2, BATHTUB FITTING CRACKED AT STA 280 L27L. REMOVED CRACKED FITTING. FABBED REPAIR PARTS FROM BAC1503-100163 PER SRM 53-2-0 FIG 2D. INSTALLED NEW FITTING AND REPAIR PARTS PER SRM 53-2-0 FIG 2D, 51-1-8, 51-1-20D, 51-3-0, 51-1-15.SDR UPS04843165Fitting · crackedINSPECTION TYPE:C2 LONGERON 36 END FITTING CRACKED AT STA 203. REMOVED AND REPLACED END FITTING REF DC8 SRM 51-1-20D.SDR SWIA200413776Clip · crackedFLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00; RBL 9.0; IB LOCATION. (ITEM FOUND AT C-CHECK INSPECTION.) CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-25-16 AND 51-21-11.SDR USAA040783Stringer Clip · crackedPIT - Q5, TIE- .1250 INCH CRACK, RIVET, STR TO FRAME CLIP, STA 663.75-S10R. REMOVED AND REPLACED STRINGER CLIP (TIE) IAW 53-00-03.SDR UPS04243244Fitting · crackedINSPECTION TYPE:C, SUSPECT CRACK ON LEFT 950 O/B LUG AFT SIDE. FITTING REPLACED IAW SRM 51-30-02 AND AAAE EO 2004-083-001R1 (727-53- 20161).SDR USAA040810Stringer Clip · crackedPIT, Q5, STRINGER CLIPS, .5000 INCH AND .1250 INCH CRACKS, STA 578, STR S9R. CLIP REPLACED IAW SRM 51-40-02.SDR ACE08282004Stringer Clip · missingDURING SCHEDULED STRUCTURAL INSPECTION OF THE AREA, FOUND STRINGER CLIP PN. 114-430066-5 NEVER INSTALLED AND THE BULKHEAD AT FS 363.25 HAD CRACKS IN THE FLANGE ABOVE AND BELOW THE MISSING CLIP LOCATION.SDR USAA040676Anchor Fitting · corrodedANCHOR FITTINGS, .1250 INCH BY .1250 INCH AREA, CORROSION: LEVEL 1; TASK NR C53-107-02 ANCHOR FITTINGS (2) STA 993L. REPLACED FITTINGS IAW SRM 51-10-2.SDR SWAA042460Stringer Clip · crackedDURING SCHEDULED 1/2D CHECK, FOUND STRINGER CLIP AT BS 400 TO BS 420, STRINGER 16L, CRACKED. REMOVED AND REPLACED STRINGER CLIPS PER SRM.SDR IXXA0500048SFitting · damagedDURING A ROUTINE C-CHECK INSPECTION, LT FUSELAGE LONGERON 24 FITTING FRAME WAS REMOVED AND INSTALLED TO COMPLY WITH N/R 3484 SID 960.000L-24 TO L-23L. REPAIR ACCOMPLISHED, REMOVED FRAME FITTING, CLEANED, TREATED AND PRIMED AREA. FABRICATED SPLICES AND DOUBLESDR ASOA04664Bracket · crackedDURING A C-CHECK IN MCN, THE RAM AIR SPIDER DUCT BRACKET IN THE AFT EQUIPMENT BAY WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE RAM AIR SPIDER DUCT BRACKET IN THE AFT EQUIPMENT BAY IAW AMM 21-52. (M)SDR USAA040588Stringer Clip · crackedPIT - FOUND TIE CLIP CRACKED .125 INCH, STATION 847 S10R ATTACH TIE CLIP. REMOVED AND REPLACED STRINGER CLIP PER SRM 51-20-02. (M)SDR USAA040590Stringer Clip · crackedPIT - FOUND TIE CLIP CRACKED .24 INCH, INTERIOR TIE CLIP STATION 807 10R. REPLACED TIE CLIP PER SRM 53-40-03. (M)SDR USAA040589Stringer Clip · crackedPIT - FOUND TIE CLIP CRACKED .25 INCH, STATION 847 - 4L INTERIOR TIE CLIP. REPLACED TIE CLIP PER SRM 53-40-03. (M)SDR SWIA200413753Attach Angle · crackedFS 280 LEFT HAND FLOORBEAM LBL 9.0 INBOARD AND OUTBOARD ATTACH ANGLES CRACKED. ITEM FOUND AT C-CHECK INSPECTION. REPLACED ANGLES IAW CRJ SRM 51-40-11, 51-42-06, 51-23-00, 51-42-21, 51-42-13, 51-21-11.SDR COOSDR040033Fitting · corrodedMAIN CARGO CABIN FROM Y STA 960 TO Y STA 980 FITTINGS, CORRODED.SDR MWEA040148Fitting · corrodedFLOOR SUPPORT FITTINGS AT FRAME STATION 430 BETWEEN NUMBER 30 AND 29 RIGHT LONGERON HAS MODERATE CORROSION ON THE UPPER SURFACE, ALSO NUT PLATES ARE CORRODED. FABRICATED AND INSTALLED FITTING AND INSTALLED TWO EACH NUT PLATES.SDR COMA0460470Angle · crackedINTERCOSTAL ANGLE AT FS 484.00 LBL 36 IS CRACKED. PERFORMED A MAJOR REPAIR AT FS 484.00 LBL 36 BY CUTTING AWAY DAMAGED ATTACHMENT FLANGE, EDDY CURRENT AREA, FABBED NEW ANGLE AND INSTALLED IAW BOMBARDIER REO 601R-53-059 REV A.SDR USAA040598Stringer Clip · crackedPIT - FOUND CLIP CRACKED .5 INCH, STATION 827 STRINGER 4L TIE CLIP. DEFECTIVE PART REPLACED WITH IDENT PART NR PER SRM 51-00-00. (M)SDR USAA040599Stringer Clip · crackedPIT - FOUND CLIP CRACKED .5 INCH, STATION 807 STRINGER 4L. DEFECTIVE PART REPLACED WITH IDENT PART NR PER SRM 51-00-00. (M)SDR UPS04443011Fitting · crackedINSPECTION TYPE: C, RT BS 1241 REAR SPAR UPPER SPLICE PLATE CRACK FOUND AT HOLE NR 6, APPROX 0.090 INCH IN LENGTH RUNNING AFT ( STR R28 TO R28) CRACKED HOLE REAMED TO 1.000 INCH IAW EO B747-5740-17032.SDR ASAA0410381Stringer Clip · corrodedPAE - CORROSION FOUND ON STRINGER CLIP. REMOVED DAMAGE, FABRICATED AND INSTALLED STRINGER CLIP. (M)SDR SWIA200413749Attach Fitting · crackedFUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED FS 280.00 LBL 9.0 O/B CLIP. ITEM FOUND AT C-CHECK INSPECTION. CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-23-01, 51-42-13, 51-21-11, 51-25-16.
Back to JASC 5340