JASC 5411
Service difficulty reports · 1,454
Reports filed under 5411 · Nacelle/Pylon, Frame/Spar/Rib, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5411' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5411' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR KCSA081391Frame · crackedNR 2 PYLON REAR ENG MOUNT BULKHEAD LT AFT FRAME WEB IS CRACKED (.750 INCHES) AT 221.9, LBL 5, WL 148.5. (S)SDR 08FDEA03378Rib · crackedNR 2 ENG BEAVER TAIL NR 2 AND NR 3 RIB CRACKED OR MISSING AT TRAILING EDGE. REMOVED DAMAGED RIB AND INSTALLED NEW RIBS REFERENCE DC/MD-10 SRM 51-35-01; VOL II AND 51-31-01; VOL II.SDR SWIA200820064Frame · crackedC-CHECK, RIGHT INBOARD NACELLE FRAME CRACKED. REPLACED FRAME.
SDR S9BA2008026Longeron · crackedRT HAND NACELLE INBOARD LONGERON CRACKED 10 1/2 INCHES AFT OF THE FWD END. REMOVED AND REPLACED RT HAND INBD LONGERON IAW AC 4313-1B CH 4, RD 6-54-036 AND VERIFIED MOD 6/1655 IS INSTALLED PER AD 80-13-12 R1. (A)SDR 08FDEA03211Spar · wornTHE NR 3 PYLON UPPER SPAR OUTBD AND INBD SPAR ANGLES HAVE 3 BOLTS; FWD TO AFT; BOTH SIDES LOOSE AND 7 FROM INBD TO OUTBD ARE LOOSE ON THE UPPER WEB AT PYLON STA YN 358. COMPLIED WITH FEDEX EA 8-5450-123625.SDR 08FDEA03212Spar · shearedTHE NR 3 PYLON STA YN 417, UPPER SPAR WEB AT THE BULKHEAD HAS 1 SHEARED FASTENER. REPLACED FASTENER IAW MD-10-10 AMM 20-50-02-2. PERFORMED BHEC TEST ON THE NR 3 PYLON UPPER SPAR WEB AT THE BULKHEAD IAW STSPM 06-10-01.003. NO DEFECTS NOTED.SDR 08FDEA03167Rib · crackedNR 1 PYLON ATTACH FLANGE FOR PANEL 438 GL IS CRACKED. REMOVED AND REPLACED RIB NR AUB 7107-39, PO 625780.4 IAW DAC DWG AUB 7107, REV "P" AND DC/MD-10 SRM 51-35-01, VOL II.SDR KCSA081345Frame · gougedNR 2 PYLON NAC STA 200 HAS A DEEP GOUGE AT FRAME BETWEEN STR 1 & 2 RT SIDE. (A)SDR KCSA081344Frame · chafed#2 PYLON NAC STA 200, BETWEEN STR 2 &3 HAS CHAFFED DAMAGED ON OUTBOARD SIDE OF FRAME. (A)SDR KCSA081343Rib · damaged#2 PYLON NAC STA. 180 RT SIDE OF SUPPORT RIB DAMAGED AT NACELLE ANTI-ICE PRESSURE SWITCH MOUNT BRACKET FORWARD ATTACH POINT. (A)SDR KCSA081342Frame · crackedNR 4 PYLON NAC STA 221.90 OUTBOARD AFT FRAME IS CRACKED .500" AT SKIN ATTACHMENT. (A)SDR SWIA200820027Frame · crackedRT NACELLE O/B WHEEL WELL FRAME IS CRACKED. C-CHECK, INSTALLED REPAIR DOUBLER TO NR 2 NACELLE WHEEL WELL INNER WEB SUPPORT INTERCOSTAL O/B SIDE.SDR KCSA081330Frame · crackedNR 2 PYLON REAR ENG MOUNT BULKHEAD OUTBOARD AFT FRAME WEB CRACKED .500 INCH AT NAC STA 221.9. (S)SDR KCSA081329Frame · crackedNR 3 PYLON REAR ENG MOUNT BULKHEAD OUTBOARD FWD FRAME WEB CRACKED .500 INCH AT NAC STA 221.9. (S)SDR KCSA081328Frame · crackedNR 4 PYLON REAR ENG MOUNT BULKHEAD OUTBOARD FWD FRAME WEB CRACKED .750 INCH AT NAC STA 221.9. (S)SDR KCSA081327Frame · crackedNR1 PYLON REAR ENG MOUNT BULKHEAD OUTBOARD AFT FRAME WEB CRACKED ONE INCH AT NAC STA 221.9. (S)SDR KCSA081326Frame · crackedNR 1 PYLON REAR ENG MOUNT BULKHEAD INBOARD AFT FRAME WEB CRACKED ONE INCH AT NAC STA 221.9. (S)SDR KCSA081325Frame · crackedNR 1 PYLON REAR ENG MOUNT BULKHEAD INBOARD FWD. FRAME WEB CRACKED ONE INCH AT NAC STA 221.9. (S)SDR UPS08852999Stringer · crackedINSPECTION TYPE:C2 NR 1 ALT STRINGER -54 CACKED APPROX. AT XRS 480- NR1 PYLON FABBED AND INSTALLED REPAIR IAW SRM, 51-1-8, 51-1-20D, 51-3-00.SDR KCSA081313Frame · chafedNR 2 PYLON LT SIDE FRAME IS CHAFFED AT FIRE BOTTLE AFT SUPPORT ATTACH POINT AT NAC STA. 162 (B)SDR 08FDEA02696Spar · crackedFOUND CRACK ON PYLON NR 2 LOWER SPAR UPPER SURFACE, RIB 10A. REPAIR PERFORMED IAW DRAWING R546-10344 AND RAS/70507447/004/2008 ISS A, APPROVED BY EA 6-5450-120039.SDR 2008UALA03658Spar · crackedNR 1 ENG PYLON TOP, BELOW ACCESS 441DT, RT SIDE, UPPER SPAR WEB CRACKED AT EXISTING REPAIR, CRACK NOT TERMINATED. REMOVED THE EXISTING REPAIR. FABRICATED AND INSTALLED A DOUBLER, RADIUS FILLER, AND REPAIR FILLER.SDR 08FDEA02489Rib · crackedWEB CRACKED LOWER END FORWARD OF RIB 18 RIGHT SIDE NR 2 PYLON. DRILLED CRACK STOP HOLES PER SRM 54-52-31. REMOVED THE RELATED FASTENERS PER SRM 51-40-21. MANUFACTURED THE DOUBLERS AND BROKE SHARP EDGES PER SRM 51-26-20. DRILLED FASTENER HOLES TO THE WEB ANSDR 08FDEA02488Rib · crackedWEB CRACKED LOWER END FORWARD OF RIB 18 LEFT SIDE NR 2 PYLON. DRILLED CRACK STOP HOLES PER SRM 51-40-21. REMOVED THE RELATED FASTENERS PER SRM 51-40-21. MANUFACTURED THE DOUBLER AND BROKE SHARP EDGES PER SRM 51-26-20. DRILLED FASTENER HOLES TO THE WEB AND SDR SWIA200820031Frame · crackedRIGHT NACELLE FRAME NR 1 CRACKED AT TENSION MOUNT AREAS IB AND OB. C-CHECK, REPLACED NACELLE FRAME NR 1.
SDR KCSA081281Frame · crackedNR 2 PYLON REAR ENG. MOUNT BULKHEAD FWD. O/B FRAME IS CRACKED AT NAC STA 221.9 (B)SDR 08FDEA02144Rib · crackedNR 2 PYLON RIB 8A; STA 726 OUTBD SIDE SHIM HAS A .75 INCH CRACK.SDR KCSA081271Frame · crackedNR 1 PYLON REAR ENG MOUNT BULKHEAD AFT I/B FRAME EDGE CRACKED AT NAC STA 221.9.SDR DL76L080783Spar · crackedCRACKS AT PASSTHROUGHS IN NR 2 PYLON UPPER SPAR WEB. CRACKS WERE CUT OUT AND DOUBLERS INSTALLED.SDR REXA201100318Rib · corrodedRIGHT ENGINE PYLON OUTBOARD RIB HAS FRETTING DAMAGE 0.002" DEEP TO PRODUCTION RISER. REPAIRED IAW REPAIRED IAW BOMBARDIER REO 601R-54-54-030 REV H.SDR DL757080781Fitting · damagedDURING ACCOMPLISHMENT OF THE SIP MOD PER S/B 757-54-0034 REV 1, THE NR 2 PYLON MID SPAR FITTING UPPER HORIZONTAL TANGE WAS MISDRILLED IN A FORWARD MOST HOLE LOCATION. THE FINAL CLEANUP SIZE HOLE WAS 0.704". A BUSHING AND RETENTION WASHER WERE INSTALLED AS A SDR NWAA082366623Frame · crackedDURING M-CHECK FOUND CRACK IN NR 4 PYLON NACELLE BULKHEAD FRAME AT NAC STA 221.90 LT. REPAIRED PER EA 66-212663.SDR UPS08852463Frame · chafedINSPECTION TYPE:C2 NR 2 PYLON UPPER PANEL FRAME, WORN BEYOND LIMITS, DEEP CHAFED DAMAGE BETWEEN PANELS 293A/B AND 294A/B. FABBED AND INSTALLED NEW PANEL FRAME IAW SRM, 51-1-8, 51-1-20D, 51-1-2 1, 54-3-3 FIG 7.SDR NOCA04008Frame · crackedAFT A FRAME LOWER CHANNEL CRACKED AT RIVET I/B FWD SIDE OF A FRAME BELOW DIAG BRACE AFT FITTING. REPLACED CRACKED C-CHANNEL IAW SRM 51-10-02.SDR KCSA081242Spar · gougedNR 3 PYLON MID SPAR WEB IS GOUGED AT NAC STA 202.SDR 08FDEA01822Rib · crackedNR 2 PYLON AFT LOWER FAIRING PANEL NR 485 AL, RIB IS CRACKED AT THE LOWER ATTACH ANGLE. REMOVED CRACKED ANGLE AND REPLACED WITH A NEW ANGLE PER SRM 51-40-21 PARA 6 & 7. LOCATED & DRILLED HOLES PER SRM 51-40-44. APPLIED PRIMER PER AMM 51-23-10-0.SDR 08FDEA01802Rib · wornNR 1 PYLON STRINGER FOR PANEL 439 AL FWD LEFT LANDING IS WORN. REMOVED FWD RIB IAW SRM 51-31-01; VOL II & 51-35-01; VOL II. DRILLED UP NEW RIB IAW DWG AUB 7107, REV F & SRM 51-31-01; VOL II. INSTALLED NEW RIB IAW SRM 51-31-01, VOL II & 51-35-01; VOL SDR 08FDEA01803Longeron · chafedNR 1 PYLON AFT LOWER FAIRING PANEL 475 AL; UPPER LT ATTACH ANGLE IS CHAFED ON THE INNER SURFACE. BLENDED CHAFED AREA PER SRM 51-77-10. FOUND TO BE OUT OF LIMITS PER SRM 54-55-51 TABLE 101 SHEET 1. ORIGINAL MATERIAL 0.071. MATERIAL REMAINING 0.047. MATERIAL RESDR 2008UALA02650Spar · crackedNR 2 PYLON UPPER SPAR WEB IS CRACKED AT OTBD DRAIN HOLE, NAC STA 156. MAJOR REPAIR ACCOMPLISHED, ACCOMPLISHED HFEC AND FOUND 2 CRACKS APPROX .5 INCH LONG. STOP DRILLED CRACKS. FABRICATED AND INSTALLED A REPAIR DOUBLER.SDR 08FDEA01612Spar · crackedCRACK FINDING ON LT PYLON NR 2 LOWER SPAR AT RIB 10. REPAIR PERFORMED BY CUTTING AREA AND INSTALLING A DOUBLER IAW DRAWING R546-10342 ISS A , APPROVED BY RAS/AS/0040/2008 AND EA 6-5451-115284.SDR 08FDEA01620Rib · damagedNR 1 PYLON PANEL 437EL HAS A DAMAGED RIB. REMOVED REPLACED RIB NR AUB7079-9 PO NR 577666.3 IAW DC/MD 10 SRM 51-35-01 VOL II.SDR 08FDEA01412Spar · crackedFOUND CRACK ON PYLON LOWER SPAR CENTER STIFFENER RIB 10 REPAIR PERFORMED IAW, DRAWING R546-10340 AND SB 54-6019, APPROVED BY RAS/AS/0029/2008 ISS A AND EA 6-5450-117165.SDR 08FDEA01257Spar · damagedFOUND OVERSIZED HOLE ON PYLON NR 2 LOWER SPAR, BETWEEN RIB 12-18. REPAIR PERFORMED BY BORING THE HOLE TO 21,5 MM, FREEZE INSTALLATION OF SHOULDERED BUSH IAW RAS 70503539/004/2008 AND REPAIR DRAWING R546-10338, APPROVED BY EA 6-5451-114870.SDR KCSA081204Frame · crackedNR 3 PYLON FRAME CRACKED AT NAC STA 268.06.SDR ABXA080136Frame · crackedPANEL 8105 FRAME CRACKED, LOWER PYLON BELOW AND FORWARD OF AFT ENGINE MOUNT. INSTALLED SPLICE REPAIR IAW DC9 DWG K05683.SDR FDKA200803128Rib · chafedTHE PREVIOUS REPAIR ON THE L/B UPPER RIB ON THE LT LOWER COWLING IS CHAFED. THE RIB HAS BEEN REMOVED AND REPLACED.SDR 2008UALA01607Pin · crackedNR 1 PYLON, LT MIDSPAR FUSE PIN HAS CRACK INDICATIONS IN INSIDE DIAMETER. MAJOR REPAIR ACCOMPLISHED: MIDSPAR FUSE PIN IS REPLACED WITH NEW PIN (P/N 311N5500-1).SDR KCSA081191Frame · crackedNR 2 PYLON AFT ENGINE MOUNT BULKHEAD FRAME CRACKED 1.25 INCH AT NAC STA 221.9.SDR KCSA081190Frame · crackedNR 2 PYLON AFT ENG MOUNT BULKHEAD FRAME CRACKED .5 INCH AT NAC STA 221.9.SDR 08FDEA00891Frame · crackedNR 2 STRINGER PANEL 485AL HAS A CRACKED FRAME ON THE LT SIDE AT FWD MID SKIN. REMOVED CRACKED FRAME; RECEIVED NEW FRAME P/N 221-0081-181; PO 611742.3. LOCATED HOLES IAW SRM 51-40-40 AND INSTALLED IAW SRM 51-40-31 PARA 6. MINOR REPAIR.
Back to JASC 5411