SDR ORJA95118Support · corrodedRT WING INBOARD NR 2 FLAP VANE SUPPORT IS WORN ON LEADING EDGE AND HAS LIGHT CORROSION. REMOVED AND CLEANED CORROSION AND APPLIED CORROSION INHIBITING COMPOUND PER SRM CHAP 51-10-3. (M)SDR 96ZZZX2837Bracket · crackedNR 2 FLAP TRACK, INBOARD ATTACH BRACKET (TO AUXILIARY LOWER T/E STRUCTURE) HAS A CRACK APPROXIMATELY 1 INCH LONG. REMOVED AND REPLACED BRACKET WITH NEW BRACKET PER SRM 51-20-1.SDR UPS204859Spar · crackedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LT WING INBOARD FLAP REAR SPAR CRACKED FROM STA XW 59.5 TO XW 63.6. MAINTENANCE REPAIRED IAW UPS EO DC8-5710-7526A.SDR UPS204854Skin · delaminatedWHILE ON GROUND, MAINTENANCE FOUND LEFT WING INBOARD FLAP TE 3 INCHES FROM OUTBOARD EDGE DELAMINATED 17 INCHES BY 4 INCHES, T/E IS SPLIT 3 INCHES. MAINTENANCE REMOVED AND REPLACED AFT FLAP ASSY IAW MM 27-51, OPS CK NORMAL.SDR CA951027001Flap Track · cracked(CAN)DETAILED INSPECTION FOUND THE RIGHT HAND FLAP SEEMED TO HAVE EXCESSIVE PLAY. ON CLOSER EXAMINATION IT WAS FOUND THAT THE FLAP TRACK WAS CRACKED. TRACK REPLACED AND AIRCRAFT RETURNED TO SERVICE.SDR DL72W954148Spar · crackedDURING SHOP INSPECTION, NR 3 MID-FLAP, LOWER AFT SPAR RAIL FOUND CRACKED 19 INCHES FROM INBOARD END OF FLAP. REPAIRED PER MM 57-54-0.SDR UPS804831Vane · delaminatedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LT NR 2 FLAP VANE DELAMINATED AT UPPER OUTBOARD END. REPLACED FLAP VANE ASSY PER MM 27-51-14.SDR UPS804830Vane · delaminatedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LT NR 5 FLAP VANE DELAMINATED AT LOWER OUTBOARD END. REPLACED VANE ASSY PER MM 27-51-14.SDR ABXA9500989Skin · corrodedDURING CARGO MOD, OFF WING INSPECTION, FOUND LEVEL 2 CORROSION ON THE INBOARD LOWER SKIN. REPLACED SKIN IAW DC-9 DRAWING 5910039 AND SRM 51-10-3.SDR ABXA9500988Spar · corrodedDURING CARGO MOD, OFF WING FLAP INSPECTION, FOUND LEVEL 2 CORROSION ON THE AFT LOWER SPAR. REPLACED LOWER AFT SPAR IAW DC-9 DRAWING 5910039 AND SRM 57-50-1.SDR MALA954671Doubler · wornDURING A SCHEDULED INSPECTION IN MSP, MAINTENANCE FOUND THE LEFT FLAP ROLLER DOUBLER, P/N 27-31141, NEARING WEAR LIMITS. REPAIRS WERE COMPLETED BY REPLACING THE DOUBLER IAW FAC SRM 57-90-10 AND ARP 57-20-9424. (M)SDR DL72S954254Chord · crackedDURING SHOP VISIT, A CRACK WAS DISCOVERED ON AFT CHORD AT I/B DRIVE ROD CUTOUT, OF NR 2 MIDFLAP. REPAIRED PER MM 57-52-0.SDR ASAA9580239Mounting Lug · crackedPAE - DURING 15K CHECK, CRACK WAS FOUND ON THE OUTBOARD MOUNTING LUG ON THE RT INBOARD FLAP VANE. REPLACED MOUNTING LUG IAW DC-9, MM 27-50-01. TAC: 23488. (X)SDR ASAA9580238Bolt · crackedPAE - DURING 15K CHECK, MOUNTING BOLT WAS FOUND CRACKED IN THE LT INBOARD FLAP OUTBOARD HINGE, BOLT HEAD BROKE OFF WHEN TORQUE APPLIED. REPLACED BOLT IAW DC-9, MM 27-51-01. TAC: 23488. (X)SDR 96ZZZM334Carriage · wornRIGHT NR 2 UPPER FLAP CARRIAGE HAS A WEAR MARK APPROXIMATELY .040 INCH TO .050 INCH DEEP IN THE VERY UPPER INBOARD EDGE ADJACENT TO THE BONDING LEAD ATTACHMENT TO THE FLAP. BLENDED WEAR MARK TO A SMOOTH DEPRESSION AS PER AVRO FAX. PERFORMED EDDY CURRENT TO BSDR 96ZZZM333Skin · wornLEFT INBOARD TRAIL FLAP TOP SIDE HAS 2 SPOTS OF WEAR THROUGH PAINT, NEED FURTHER INVESTIGATION FOR LIMITS. BLENDED DAMAGED AREA TO A SMOOTH DEPRESSION. PERFORMED ET TO BLENDED AREA. NO DEFECTS FOUND. INSPECTION RIVET NO DAMAGE NOTED, TREATED PRIMED AND TOPSDR DLL15954649Skin · wornNR 3 RT FLAP VANE UPPER SKIN HAD A WORN AND SCRATCHED SPOT. REPLACED SKIN SECTION PER SRM 57-53-00.SDR 96ZZZM336Bolt · corrodedFORWARD FLAP ATTACH BOLT AT LEFT FLAP TRACK NR 3 IS CORRODED. REMOVED, CLEANED AND INSPECTED BOLT, REINSTALLED BOLT. NO CORROSION FOUND.SDR ABXA9600091Angle · crackedDURING C-CHECK INSPECTION, FOUND BOTH OUTBOARD FLAP HINGE ATTACH BRACKETS CRACKED INSIDE LEFT FLAP. REPLACED BRACKETS IAW DC-9 SRM 51-30-2 AND 51-30-5.SDR ABXA9600090Angle · crackedDURING C-CHECK INSPECTION, FOUND BOTH OUTBOARD FLAP HINGE ATTACH BRACKETS CRACKED INSIDE THE LEFT FLAP. REPLACED BRACKETS IAW DC-9 SRM 51-30-2 AND 51-30-5.SDR ABXA9600089Angle · crackedDURING C-CHECK INSPECTION, FOUND BOTH OUTBOARD FLAP HINGE ATTACH BRACKETS CRACKED INSIDE RIGHT FLAP. REPLACED BRACKETS IAW DC-9 SRM 51-30-2 AND 51-30-5.SDR ABXA9600088Angle · crackedDURING C-CHECK INSPECTION AND COMPLIANCE OF AD 92-22-08, FOUND BOTH OUTBOARD FLAP HINGE ATTACH BRACKETS CRACKED INSIDE THE RIGHT FLAP. REPLACED BRACKETS IAW DC-9 SRM 51-30-2 AND 51-30-5.SDR 96ZZZM337Bolt · failed testLEFT NR 3 FLAP TRACK CARRIAGE TO FLAP ATTACH BOLT HAS FAILED UT INSPECTION AND NEEDS NEW BOLT INSTALLED. REMOVED AND REPLACED FLAP ATTACH BOLT.SDR 96ZZZM363Bushings · damagedPIN ASSY FLAP UPPER CARRIAGE TO LEVER FOUND BUSHING WITH PLATING LOSS SCRAPED. SSI NR 57-55-129, NR 3 RIGHT FLAP. REMOVED AND REPLACED FLAP UPPER CARRIAGE TO LEVER BUSHING, NR 3 RIGHT FLAP.SDR AWXA9500712Flap Track · corrodedPHX - DURING SCHEDULED C21 INSPECTION, FOUND NR 7 FLAP TRACK CORRODED ON UPPER SURFACE WHERE TRACK MOUNTS TO WING. ALSO, FOUND SMALL NICK ON ONE BOLT HOLE. REPAIRED PER ER 2-57-40 15A. (M)SDR AWXA9500711Flap Track · corrodedPHX - DURING SCHEDULED C21 INSPECTION, FOUND CORROSION BETWEEN WING SHIM AND NR 8 FLAP TRACK AFT MOUNTING. REPAIRED PER ER 2-57-40-15A. (M)SDR AWXA9500710Flap Track · corrodedPHX - DURING SCHEDULED C21 INSPECTION, FOUND LT WING NR 2 FLAP TRACK AFT OUTBOARD MOUNT HOLE CORRODED AT BUSHING. COMPLIED WITH OVERSIZING OF MOUNT HOLE PER ER 2-57-44-19A. (M)SDR 9518569763Skin · crackedDURING LINE CHECK, FOUND CRACKS IN THE LEFT AND RIGHT FLAP TRAILING EDGES. REPAIRED FLAPS PER EA 98-104972, -104973 RESPECTIVELY.SDR UPS404806Le Skin · crackedWHILE ON GROUND, MAINTENANCE FOUND RT INBD MIDFLAP LEADING EDGE HAS MULTIPLE CRACKS ON INBD SIDE APPROX 14 INCHES LENGTH, BEYOND SRM 51-40-09 LIMITS. VACUUMED TO CORE TO REMOVE WATER, INSTALLED HOT BONDED REPAIR PER SRM 51-40-12, PRIMED AND PAINTED LEADING EDSDR UPS404805Skin · crackedWHILE ON GROUND, MAINTENANCE FOUND RT INBD FOREFLAP INBD EDGE HAS A CRACK APPROX 2.5 INCHES LENGTH, BEYOND SRM 51-40-09 LIMITS. REPAIRED IAW SRM 51-40-09.SDR IXXA199587Flap Fitting · brokenAT MSP, IT WAS DISCOVERED THAT THE STATION 98 OUTBOARD FLAP BASE FITTING ON LEFT INBOARD FLAP SECTION HAD EXPERIENCED A TYPICAL FAILURE DUE TO A CRACK THAT ORIGINATED IN THE UPPER FLAP VANE ATTACH BOLT HOLE. THE OPPOSING BASE FITTING AT THAT STATION HAD RECIESDR 95ZZZX6063Flap Rib · crackedDURING INSPECTION OF FLAP SYSTEM, NOSE RIB IN RIGHT FLAP WHERE FLAP ACTUATOR CONNECTS WAS FOUND CRACKED AND FLAP SKIN WAS DEFORMED. SUBMITTER SUGGESTS IT APPEARS TO BE CAUSED BY FLAP BEING OUT OF RIG AND BOTTOMING OUT IN FLAP TRACK.SDR MALA954663Rib · crackedDURING A SCHEDULED INSPECTION IN MSP, THE LEFT FLAP INBOARD ACTUATOR RIB WAS FOUND TO BE CRACKED. REPAIRS WERE COMPLETED BY INSTALLING DOUBLER IAW FAC SRM 51-00-00, 57-90-10, REPAIR NR 11, AND LAR 95-MALA-254. (M)SDR 96ZZZX1891Vane · delaminatedDURING C-CHECK, FOUND RT WING, OUTBOARD FLAP VANE DELAMINATED. REPLACED VANE, PN 593496-1. ACFT TT: 22,675 HRS. ACFT TC: 41,431.SDR 96ZZZX1890Vane · delaminatedDURING C-CHECK, FOUND RT WING, INBOARD FLAP OUTBOARD VANE DELAMINATED. REPLACED VANE, PN 5930495-504. ACFT TT: 22,675 HRS. ACFT TC: 41,431.SDR 96ZZZX1889Vane · delaminatedDURING C-CHECK, FOUND LT WING, NR 3 FLAP VANE DELAMINATED. REPLACED VANE, PN 5930496-1. ACFT TT: 22,675 HRS. ACFT TC: 41,431.SDR 95ZZZX5850Foreflap · corrodedON D-INSPECTION, NDT DEBOND CHECK OF RIGHT FOREFLAP FOUND CORROSION OF STR 14 AT STA YW257.35. SUBMITTER STATED REAR FOREFLAP PANELS NEED REMOVAL AT INSPECTION AND INSPECT FOR CORROSION OF BOTTOM SKIN AND HINGE AREA BY BORECOPE AND DEBOND INSPECTIONS.SDR 95ZZZX5849Foreflap · arm corrodedON D-INSPECTION OF FLIGHT CONTROLS, FOUND CORROSION ON INBD FORFLAP HINGE ARM UNDER PANEL COVER. PANELS ARE NOT REQUIRED TO BE REMOVED ON INSPECTION. PANELS NEED REMOVAL FOR CORROSION INSPECTION.SDR 95ZZZX5846Foreflap · corrodedON D-INSPECTION OF FLIGHT CONTROLS, FOUND A HINGE ARM WITH CORROSION AND, WITH THE OTHER FLAP PANELS OPEN, FOUND CORROSION AROUND PANEL NUTPLATES, STA YW367.90 TO STA YW423.30. SUBMITTER STATES PANELS NEED REMOVAL AT INSPECTION OF FOREFLAP.SDR 95ZZZX5845Foreflap · corrodedON D-INSPECTION OF FLIGHT CONTROLS OF LEFT FOREFLAP, FOUND CORROSION ON BOTTOM STR 12 AND STR 14 WITH BORESCOPE, STA YW242.17 TO YW257.35. FOREFLAP PANELS ARE NOT REQUIRED TO BE REMOVED ON INSPECTION. SUBMITTER STATED THEY NEED REMOVAL FOR INSPECTION OF CORRSDR 95ZZZX6751Rib · crackedINSPECTION FOUND CRACKED FLAP RIB AT ACTUATOR ATTACH POINT.SDR 9515559601Fitting · corrodedDURING ACCEPTANCE CHECK AND PRIOR TO SERVICE, FOUND CORROSION ON THE LEFT FLAP INBOARD FIXED VANE TIE FITTING. REPLACED FITTING PER SRM 51-30-2.SDR USVA109516Spar · crackedRIGHT WING MID INBOARD FLAP REAR SPAR UPPER ANGLE CRACKED 1 INCH LONG AT STATION WLB 73. REPAIRED PER DALFORT AVIATION XEA NR X8-57-82. (M)SDR AWXA9500697Flap Track · corrodedPHX - DURING SCHEDULED C8 INSPECTION, FOUND NR 2 FLAP TRACK UPPER AFT MOUNT CORRODED. REPAIRED PER ER 2-57-40-13. (M)SDR AWXA9500694Flap Track · corrodedPHX - DURING SCHEDULED C8 INSPECTION, FOUND NR 2 MAIN FLAP TRACK CORRODED AT PARTING SURFACE OF MOUNT BOLTS. MACHINED MOUNT SURFACE PER ER 2-57-20-12A. (M)SDR 96ZZZM341Bolt · corrodedRIGHT NR 2 FLAP CARRIAGE UPPER CARRIAGE TO FLAP BOLT HAS FLAKING PROTECTIVE COATING AND IS CORRODED. REMOVED AND REPLACED CARRIAGE TO FLAP BOLT NR 2 POS.SDR 95ZZZM592Skin · crackedRIGHT OUTBOARD FLAP CRACKED .75 INCH ON TRAILING EDGE, 35 INCHES FROM OUTBOARD END OF FLAP. STOPPED DRILLED AND INSTALLED DOUBLER. (M)SDR UPS204646Te Skin · delaminatedWHILE ON GROUND MAINTENANCE, FOUND LEFT INBD FLAP TRAILING EDGE HAS DELAMINATION. REPAIRED TRAILING EDGE FLAP PER SRM 727-51-40-6.SDR DL72E953943Spar · crackedNR 3 MID FLAP DURING HMV INSPECTION FOUND A CRACKED AFT SPAR CORD 19 INCHES FROM I/B END AND A CRACKED DOUBLER 37 INCHES FROM I/B END. REPAIRED PER M/M 57-52-0 NRC38851 (2) AFT SPAR CORD WAS CRACKED 41 INCHES FROM O/B END. REPAIRED PER M/M 57-52-0. NRC 8852SDR USVA10951Flap · crackLEFT INBOARD AFT FLAP LOWER SURFACE HAS A 2 INCH LONG CRACK. REPAIRED CRACK PER SRM 51-40-6. (M)
Back to JASC 5753