Airbus A310-203
Service difficulty reports · 2,392
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A310203' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A310203' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 08FDEA00903Panel · chafedNR 1 PYLON PANEL NR 414BR HAS 2 CORNERS CHAFED. BLENDED CHAFED AREA IAW SRM 54-52-51; FIG 101. FOUND TO BE OUT OF LIMITS IAW SRM 54-52-51; FIG 101. FABBED DOUBLER IAW SRM 54-52-51; FIG 202. ALODINED IAW SRM 51-21-10 AND PRIMED IAW 54-52-51; FIG 51-23-10. INSSDR 08FDEA00899Seat Track · unknownCENTER ARTICULATING SEAT TRACK BETWEEN FRAME 38.2 AND FRAME 40. REMOVED DAMAGED SEAT TRACK IAW SRM 51-40-21 PARA. 6. INSTALLED NEW SEAT TRACK IAW EO E-6-5310-7-3322 PT 2.SDR 08FDEA00898Skin · corrodedAFT IF THE BULK PIT FROM FRAME 78 TO FRAME 79; STRINGER 50R TO STRINGER 51R INTERIOR SURFACE HAS CORROSION. R&R DOUBLER LAV SERVICE DOOR; S50R & DRAIN MAST IAW 51-40-21 & AMM 30-71-11-4. REMOVED & REINSTALLED S45R; 47R; 48R FROM FRAMES 75-82& PAN IAW SRM SDR 08FDEA00891Frame · crackedNR 2 STRINGER PANEL 485AL HAS A CRACKED FRAME ON THE LT SIDE AT FWD MID SKIN. REMOVED CRACKED FRAME; RECEIVED NEW FRAME P/N 221-0081-181; PO 611742.3. LOCATED HOLES IAW SRM 51-40-40 AND INSTALLED IAW SRM 51-40-31 PARA 6. MINOR REPAIR.SDR 08FDEA00893Wedge · crackedRT OUTBD AILERON T/E WEDGE IS CRACKED AND THE AFT EDGE IS SEPARATED. THIS SDR WAS OPENED FOR AIRCRAFT N425FE INSTEAD OF AIRCRAFT N365FE IN ERROR. SDR 08-0895 HAS BEEN INITIATED TO ADDRESS THE DISCREPANCY DOCUMENTED ON NON-ROUTINE N00026 THAT WAS WRITTEN AGAISDR 08FDEA00890Longeron · chafedNR 2 ENGINE PYLON AFT FAIRING; OUTBD UPPER LONGERON IS CHAFED AT SEVERAL SCREW HOLES. REMOVED DAMAGED LONGERON IAW A310-300 SRM 61-40-21; PG 7. RECEIVED LONGERON P/N 221-0081-328, PO 610555.3 AND LOCATED HOLES IAW A310-300 SRM 51-40-40. INSTALLED LONGERON ISDR 08FDEA00889Longeron · chafedNR 2 ENGINE PYLON AFT FAIRING; OUTBD UPPER LONGERON IS CHAFFED AT SEVERAL SCREW HOLES. REMOVED DAMAGED LONGERON IAW A310-300 SRM 61-40-21; PG 7, RECEIVED LONGERON P/N 221-0081-328, PO 610555.3 AND LOCATED HOLES IAW A310-300 SRM 51-40-40. INSTALLED LONGERON ISDR 08FDEA00888Floor Panel · damagedFOUND FLOOR PANEL P/N 35039003 HAS EDGE DAMAGE. REPAIRED FLOOR PANEL 132 YF I.A.W. FEDEX DWG. SRZ-25-00 REV. E.SDR 08FDEA00887Floor Panel · damagedAFT CARGO PIT FLOOR PANEL 151FF HAS CORNER DAMAGE. FABRICATED NEW FLOOR PANEL. POTTED EDGES. COMPLETED CURE & SANDED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.SDR 08FDEA00886Floor Panel · damagedFLOOR PANEL 152YF HAS EDGE DAMAGE AND IS DENTED. FABRICATED NEW FLOOR PANEL. POTTED EDGES, COMPLETED CURE & SANDED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.SDR 08FDEA00885Floor Panel · delaminatedFWD CARGO PIT FLOOR PANEL 132GF HAS EDGE DAMAGE AND IS DELAMINATED. FABRICATED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES, CURED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.SDR 08FDEA00884Floor Panel · delaminatedFWD CARGO PIT FLOOR PANEL 131RF IS DELAMINATED IN 5 AREAS. FABBED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES, CURED EDGE POTTING; INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.SDR 08FDEA00883Panel · damagedFWD CARGO PIT CEILING PANEL 132GC HAS EXPOSED CORE ON BOTH SIDES OF THE PANEL. REPAIRED PANEL & APPLIED PAINT (WHITE) ON FWD PIT CEILING IAW DRAWING SRZ 25-013.SDR 08FDEA00882Fairing · delaminatedRT HORIZONTAL STABILIZER LOWER APRON FAIRING IS DELAMINATED. REAPPLIED ADHESIVE PER SRM 55-15-11; PARAGRAPHS (H) & (I) TO DISBONDED SILICONE MATERIAL.SDR 08FDEA00838Skin · corrodedAFT PIT LOWER FUSELAGE SKIN IS CORRODED AT FRAME 62; S56R. REMOVED CORROSION IAW SRM 51-74-10; CHECKED LIMITS IAW SRM 53-17-12. FOUND TO BE WITHIN LIMITS IAW SRM 53-10-12. ALODINED IAW A310 SRM 51-21-10. PRIMED AND PAINTED BOTH IAW A310 SRM 51-23-10. SDR 08FDEA00845Frame · corrodedAFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB AT FRAME 65 BETWEEN STR 49L AND 50L. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMITS IAW SRM 53-17-12. FOUND TO BE WITHIN LIMITS. ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED BOTH IAW SRM 51-23-10. MINORSDR 08FDEA00841Frame · corrodedAFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB AT FRAME 67 ABOVE S49L. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMITS IAW SRM 53-17-13. FOUND TO BE WITHIN LIMITS; ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED BOTH IAW SRM 51-23-10. MINOR REPAIRSDR 08FDEA00862Rib · crackedLT WINGLET RIB CRACKED REPLACE, REPAIR RIB.SDR 08FDEA00861Panel · damagedAFT PIT CEILING PANEL 162AB OUTER SURFACE IS DELAMINATED AND CRACKED; THE INNER SURFACE HAS PUNCTURED AREAS. REPAIRED IAW DWG SRZ 25-013 & PAINTED.SDR 08FDEA00860Panel · puncturedAFT CARGO PIT PANEL NR 152LW IS PUNCTURED. REPAIRED AFT PIT PANEL & TOP COATED (WHITE) IAW DWG SRZ 25-031.SDR 08FDEA00859Panel · damagedBULK CARGO PIT PANEL NR 161JW IS PUNCTURED AND DELAMINATED. REPAIRED BULK CARGO PIT IAW DWG SRZ 25-013. PAINTED PANEL IAW DWG SRZ 25-013.SDR 08FDEA00858Panel · damagedAFT CARGO PIT PANEL NR 161MW IS DELAMINATED AND PUNCTURED. REPAIRED PANEL & APPLIED TOP COAT (WHITE) ON AFT CARGO PIT IAW DWG SRZ 25-013.SDR 08FDEA00857Panel · damagedAFT CARGO PIT CEILING PANEL NR 152 DC IS DELAMINATED AND DENTED. RECEIVED NEW PANEL. TO BE INSTALLED ON CARD 41C0071.SDR 08FDEA00856Panel · puncturedAFT CARGO PIT PANEL NR 162 OW IS PUNCTURED. REPAIRED AFT CARGO PIT PANEL AND TOP COATED ( WHITE ) IAW DRAWING SRZ -75-013.SDR 08FDEA00855Panel · debondedAFT CARGO PIT PANEL NR 151PW IS DISBONDED. REPAIRED PANEL & APPLIED TOP COAT WHITE IAW DRAWING SRZ 25-013.SDR 08FDEA00854Panel · delaminatedFOUND DELAMINATION ON PANEL NR 143FL, INTERIOR SKIN. REPAIRED BY REMOVING DAMAGE. APPLIED, CURED & SANDED WET LAY UP. APPLIED REFINISH IAW SRM 51-77-10 & SRM 51-75-10.SDR 08FDEA00853Panel · puncturedPUNCTURE ON THE INTERIOR SURFACE OF PANEL NR 144FR. REPAIRED INTERIOR SURFACE BY REMOVING THE DAMAGE. APPLIED, CURED & SANDED THE WET LAY UP. APPLIED REFINISH IAW SRM 51-77-10 & SRM 51-75-10.SDR 08FDEA00852Floor Panel · delaminatedFLOOR PANEL PANEL 147 AF IS DELAMINATED AND OIL SATURATED. FABRICATED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES. CURED EDGE POTTING. INSTALLED INSERTS AND APPLIED NON-SKID IAW SRZ 25-005; REV F.SDR 08FDEA00851Rub Strip · damagedLT OUTBD FLAP UPPER SURFACE CENTER CHAFE STRIP IS WRINKLED AND BULGING. REMOVED & REPLACED THE CHAFE STRIP IAW SRM 57-53-12; FIG 201.SDR 08FDEA00850Rub Strip · debondedLT OUTBD FLAP UPPER EXTERNAL SKIN HAS THE METAL CHAFE STRIP DISBONDED. REMOVED & REPLACED CHAFE STRIP IAW SRM 57-53-12 FIG 201.SDR 08FDEA00849Skin · delaminatedLT OUTBD FLAP AFT EDGE OF THE FLAP IS DELAMINATED ON THE UPPER SURFACE. PREPARED & RESEALED IAW SRM 57-53-12 FIG 209.SDR 08FDEA00848Floor Panel · peelingMLG WHEEL WELL FLOOR PANEL 148BF UPPER LAYER IS PEELING. FABRICATED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES. CURED EDGE POTTING. INSTALLED INSERTS AND APPLIED NON-SKID IAW SRZ 25-005; REV F.SDR 08FDEA00839Stringer · corrodedAFT PIT STR 49R HAS CORROSION ON THE LOWER RADIUS 6" AFT OF FRAME 65. REMOVED CORROSION IAW SRM 51-74-10. REMOVED FASTENERS TO F.O.M. ORIGINAL MATERIAL THICKNESS 0.092. MATERIAL REMOVED 0.004. MATERIAL REMAINING 0.088. FOUND TO BE WITHIN LIMITS IAW SRM SDR 08FDEA00847Floor Panel · damagedFLOOR PANEL 147BF UPPER LAYERS ARE DETERIORATED IN NUMEROUS PLACES. FABRICATED NEW FLOOR PANEL 147 BF; POTTED EDGES; COMPLETED CURE & SANDED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW SRZ 25-005; REV F.SDR 08FDEA00846Frame · corrodedAFT PIT FUSELAGE FRAME WEB HAD CORROSION AT FRAME 66 BETWEEN STR 49L AND STR 50L. REPAIRED FUSELAGE FRAME 66 BETWEEN STRINGER 49L & STRINGER 50L IAW SRM 53-10-10; PARA 4.SDR 08FDEA00844Frame · corrodedAFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB AT FRAME 64 BETWEEN STR 49L AND 50L. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL 0.045; MATERIAL REMOVED 0.017, MATERIAL REMAINING 0.028. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. FORMED ANGLE, HESDR 08FDEA00843Frame · corrodedAFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB AT FRAME 64 BETWEEN STR 49L AND 50L. REMOVED CORROSION IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. FORMED ANGLE, HEAT TREATED ANGLE IAW TPS 1003; REV A. DRILLED UP PARTS; ALODINED, PRIMED SDR 08FDEA00842Frame · corrodedAFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB BETWEEN STR 49L AND STR 50L, FRAME 65. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMITS IAW SRM 53-17-13 & FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. FORMED IAW SRM 51-26-00. REPAIR PARTS HEAT TREATED. REPASDR 08FDEA00840Stringer · corrodedAFT PIT STR 56R HAS CORROSION ON THE LOWER ANGLE AT FRAME 69. REMOVED FASTENERS IAW SRM 51-40-21. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL THICKNESS 0.079. REMAININGMATERIAL 0.073. WITHIN LIMITS IAW SRM 53-10-00. ALODINED IAW SRM 51-21-00. PRIMED IAWSDR 08FDEA00837Stringer · corrodedAFT PIT LOWER FUSELAGE STRINGER 51R HAS CORROSION IN THE AREA ON THE STRINGER BETWEEN FRAMES 60 AND 61. REMOVED CORROSION FROM STRINGER IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS 0.110. MATERIAL REMOVED 0.013. REMAINING MATERIAL 0.097. FOUND TO BE OUT SDR 08FDEA00835Skin · corrodedAFT PIT LOWER FUSELAGE SKIN IS CORRODED AROUND THE DRAIN HOLE AREA AT STR 57 BETWEEN FRAMES 54.1 AND 54.2. REMOVED CORROSION IAW SRM 51-74-10. ORIG. MAT. THICKNESS IS .196 IAW DWG. A53970182. REMOVED .023. REMAINING MAT. OF .173 IS WITHIN LIMITS IAW SRM 53-10SDR 08FDEA00834Stringer · corrodedAFT PIT STRINGER 45R IS CORRODED BETWEEN FRAMES 54.2 AND 54.3. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL THICKNESS WAS 0.110. REMAINING MATERIAL 0.105. WITHIN LIMITS IAW SRM 53-10-00. ALODINED IAW SRM 51-21-00. PRIMED & PAINTED IAW SRM 51-23-00.SDR 08FDEA00832Stringer · corrodedAFT PIT STRINGER 45R IS CORRODED WHERE IT PASSES UNDER FRAME 54.2. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL THICKNESS WAS 0.110. REMAINING MATERIAL 0.105. WITHIN LIMITS IAW SRM 53-10-00. ALODINED IAW SRM 51-21-10. PRIMED & PAINTED AREA IAE SRM 51-23-10.SDR 08FDEA00831Skin · corrodedAFT PIT LOWER SKIN HAS CORROSION AT STR 57; FRAMES 54 THRU 54.1. REMOVED FASTENERS IAW SRM 51-40-21. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMITS IAW SRM 53-16-12. ORIG. MAT THICKNESS IS .177 REMAINING MAT. THICKNESS .174. REMOVED .003. FOUND TO BE SDR 08FDEA00829Skin · corrodedRT SIDE FUSELAGE SKIN HAS CORROSION AROUND THE WING TO BODY FAIRING MOUNT AREA BETWEEN FRAME 45 AND FRAME 46. REMOVED CORROSION IAW SRM 51-74-10. FOUND TO BE WITHIN LIMITS IAW SRM 53-10-12; PAGE 139. ALODINED AREA IAW SRM 51-21-10. PRIMED & TOP COAT PAINTED SDR 08FDEA00828Panel · crackedRT WING LOWER SKIN IS CRACKED IN THE TRAILING EDGE AREA AT WING STA 653, JUST INBD OF RIB 11. COMPLIED WITH EA 6-5730-118457 REV A.SDR 08FDEA00827Attach Angle · corrodedAFT CARGO PIT; FWD BULKHEAD AT FRAME 54; THE CEILING PANEL ATTACH ANGLE IS CORRODED AT RBL 166 CM 65. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS .098. REMAINING MATERIAL .043. REMOVED .055, OUT OF LIMITS IAW SRM 53-10-00. REMOVED ANGLSDR 08FDEA00826Attach Angle · corrodedAFT CARGO PIT; FWD BULKHEAD AT FRAME 54; THE CEILING ATTACH ANGLE IS CORRODED FROM 131 TO 139 CM (51.5" TO 54.5 "). REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS .098. REMAINING LATERIAL .050. MATERIAL REMOVED .048. OUT OF LIMITS IAW SRM SDR 08FDEA00825Attach Angle · corrodedAFT CARGO PIT; FWD BULKHEAD AT FRAME 54; THE CEILING PANEL ATTACH ANGLE IS CORRODED FROM RBL 37 TO 48 CM (14" TO 18.5"). REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS .098. REMAINING MATERIAL .043. MATERIAL REMOVED .055. OUT OF LIMITS IASDR 08FDEA00824Floorbeam · corrodedCORROSION IS ON THE BOTTOM OF THE FLOORBEAM AT FRAME 47; LBL 103CM IN FWD PIT. FOUND TO BE OUT OF LIMITS IAW SRM 52-30-00. REMOVED EDGE MEMBER IAW SRM 51-40-21. REMOVED SEAL RETAINER IAW SRM 51-40-21. RECEIVED NEW EDGE MEMBER IAW SRM 52-31-00. FABBED D
Back to Airbus A310-203