SDR F3LA200700114Floor Panel · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOOR PANEL 261FF CORRODED. REPLACED PANEL 261FF IAW AMM 53-42-12, PB 401.SDR F3LA200700113Shear Plate · corrodedDURING C-3 CHECK, INSPECTION REPORTED AFT LT SHEAR PLATE CORRODED BETWEEN FR 69 AND FR70. REPLACED AFT LT SHEAR PLATE IAW SRM 51-42-11.SDR F3LA200700112Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED AFT LT LONGITUDINAL BEAM Y1292 HAD SURFACE CORROSION IN FASTENER HOLES AND ON TOP SURFACE. REPLACED CORRODED FLOORBEAMS (P/N D5347217220400 AND D5347218820400) AND COUPLING JUST FWD OF FR67 THRU FR 69 IAW A318 SRM 53-41-1SDR F3LA200700109Shear Plate · corrodedDURING C-3 CHECK, INSPECTION REPORTED AFT RT SHEAR PLATE HAD SMALL AMOUNT OF CORROSION BETWEEN FR 69 AND FR 70. REPLACED AFT RT SHEAR PLATE IAW SRM 51-42-11 AND 51-72-11.SDR F3LA200700108Oxygen Mask · no testWHILE PERFORMING MASK DROP TEST, ROWS 15 AND AFT ON BOTH SIDES, 7, 8, AND 9 RT SIDE, R2 DOOR AND C LAV DID NOT DROP COMPLETELY. RESET MASKS AND PERFORMED TEST AGAIN IAW AMM 35-23-00-710-001. OPS CHECKED GOOD.SDR F3LA200700101Shear Plate · corrodedDURING C-3 CHECK, INSPECTION REPORTED LT SIDE OF CABIN FLOOR WEB 69 AND 70 HAD VERY LIGHT CORROSION AT NUT PLATES, MOSTLY ON LWR SIDE. REPLACED SHEAR PLATE IAW SRM 51-42-11.SDR F3LA200700091Web · corrodedDURING C-3 CHECK, INSPECTION REPORTED RT SIDE CABIN FLOOR WEB 69 AND 70 HAD VERY LIGHT CORROSION AT NUT PLATES, MOSTLY ON LWR SIDE. REPLACED SHEAR PLATE IAW SRM 51-42-11.SDR F3LA200700084Contactor · damagedAIR RETURN AT 0130Z FOR MULTIPLE ECAMS ASSOCIATED W/AC ESS BUSS. DEPARTURE OUT OF KDEN, LEVELING AT 35,000 FT, RECEIVED ECAM ENG 1 IGN A AND ENG 2 IGN A, C/B TRIPPED L ELEC BAY, YAW DAMPER 1, RUD TRIM 1, AND TRV LIM 1. CAPTAINS PFD ND FWD DISPLAYS ALL WENT BSDR F3LA200700107Floorbeam · damagedDURING C-3 CHECK, INSPECTION REPORTED FWD SPLICE OF R2 DOOR SILL HAD TWO DOUBLE DRILLED HOLES, ONE COMPLETELY THROUGH THE FWD FLOORBEAM. REPLACED DAMAGED FLOORBEAM IAW SRM 51-42-11.SDR F3LA200700106Floor Panel · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOOR PANEL 262FF AT R-2 DOOR CORRODED ON BOTTOM OF PANEL. REPLACED FLOORBOARD 262FF IAW AMM 53-42-12-400-001.SDR F3LA200700098Rib · scratchedDURING C-3 CHECK, INSPECTION REPORTED LE OF VERTICAL STAB FIN HAD DEEP SCRATCH MARKS (TOOL MARKS) BETWEEN PANELS NR 322BL AND 322CL ON ATTACHMENT BRACKET WHERE PANEL 322BL ATTACHES. REPLACED RIB FOR VERT STAB LE BETWEEN PANELS 322BL AND 322CL IAW SRM 51-42-11SDR F3LA200700099Latch · missingDURING C-3 CHECK, INSPECTION REPORTED AFT OTBD NUTPLATE FOR THE AFT FILLER PLATE AROUND THE L2 DOOR GIRT BAR LATCH MISSING. REPLACED L2 DOOR SILL IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700097Splice · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON OTBD UPPER ANGLE AFT ATTACHMENT HOLE UPON REMOVAL OF L2 DOOR SILL SPLICE ANGLES FWD OF FR66. REPLACED L2 DOOR SILL SPLICE ANGLES IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700096Sill · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION IN NUTPLATE HOLE UNDER THE FWD GIRT FITTING ON THE L2 DOOR SILL. REPLACED L2 DOOR SILL IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700095Sill · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION IN NUTPLATE HOLES ON THE L2 DOOR SILL PLATE AT FR66. REPLACED L2 DOOR SILL IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700094Sill · corrodedDURING C-3 CHECK, INSPECTION REPORTED L2 DOOR SILL PLATE HAD CORROSION FWD OF FR66. REPLACED L2 DOOR SILL IAW 51-42-11, FIG 6 AND 7.SDR F3LA200700093Sill · corrodedDURING C-3 CHECK, INSPECTION REPORTED L2 DOOR SILL THRESHOLD HAD CORROSION AROUND SEVERAL NUTPLATE HOLES. REPLACED L2 DOOR SILL IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700092Floorboard · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOORBOARD 222FF (R1 ENTRY) CORRODED. REPLACED FLOORBOARD 222FF IAW AMM 53-12-12-400-001.SDR F3LA200700100Sill · corrodedDURING C-3 CHECK, INSPECTION REPORTED R2 DOOR SILL PLATE CORRODED FWD OF FR66. REPLACED R2 DOOR SILL IAW SRM 51-42-11.SDR F3LA200700090Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE HOLE ON FLOORBEAM -Y1292, AFT OF FR68. REPLACED FLOORBEAM AT FR68 STATION -Y1292 IAW SRM 51-42-11.SDR F3LA200700088Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE HOLE ON FLOORBEAM Y1292 FWD OF FR68. REPLACED FLOORBEAM AT Y1292 FWD OF FR68 IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700087Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE ON FLOORBEAM Y1292, AFT OF FR66. REPLACED FLOORBEAM AT Y1292 AFT OF FR66 IAW SRM 51-42-11, FIG 6 AND 7.SDR F3LA200700089Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE HOLE ON FLOORBEAM Y1292 AFT OF FR68. REPLACED FLOORBEAM AT Y1292 AFT OF FR68 IAW 51-42-11, FIG 6 AND 7.SDR F3LA200700086Bushing · corrodedDURING C-3 CHECK, INSPECTION REPORTED NLG UPPER TORSION LINK FROM STRUT CORRODED INSIDE ATTACH LUG. REMOVED CORROSION UNDER BUSHINGS OF NLG UPPER TORSION LINK ATTACH POINT AND REPLACED BUSHINGS IAW EA NR A8-32R-11869.SDR F3LA200700085Bolt · corrodedDURING C-3 CHECK, INSPECTION REPORTED WINGLET ATTACH HARDWARE RUSTY. REPLACED WINGLET ATTACH HARDWARE (MILD SURFACE CORROSION ON BOLT HEADS) ON LT WING IAW AMM 57-31-22-400-001.SDR F3LA200700048Fan · defectiveFLIGHT CREW REPORTED TOXIC ODOR IN CABIN DURING FLIGHT. ODOR MORE PREVALENT IN AFT PASSENGER CABIN AREA. INSPECTED AFT GALLEY AREA AND FOUND AFT CARGO VENT FAN DEFECTIVE. REPLACED FAN PER AMM 21-28-54-000-001. RAN PACKS AND ENGINES FOR SEVERAL MINUTES AND SDR F3LA200700031Windshield · crackedAIR TURN BACK, CAPTAIN'S FWD WINDSHIELD SHATTERED. REPLACED CAPTAINS FWD WINDSHIELD IAW 56-11-11, PB401.SDR F3LA200700023Battery Pack · dischargedDURING HEAVY CHECK, INSPECTION REPORTED EMERGENCY LIGHT FAILED TEST, 14RU MCDU. REPLACED BATTERY PACK 10WL. OPS CHECKED GOOD. REF AMM 33-51-38-000-002 AND 33-51-38-400-002.SDR F3LA200700020Battery · dischargedDURING C-3 CHECK, INSPECTION REPORTED RT OVERWING EMERGENCY LIGHTING BATTERY FAILED DURING OPS CHECK. REPLACED RT OVERWING EPSU BATTERY IAW AMM 33-51-38-400-002.SDR F3LA200600161Nut · looseDURING C-2 CHECK, INSPECTION REPORTED NR 1 ENGINE PYLON AFT UPPER THREADED SLEEVE AT RIB 10 LOCK WASHER NR 103 TANG SLIGHTLY ENGAGED IN NUT, AFT PYLON-TO-WING ATTACH FITTING. ENGAGED TANG ON NUT FOR NR 1 ENGINE PYLON AFT UPPER THREADED SLEEVE AT RIB 10 IAW AMSDR F3LA200600160Lockwasher · damagedDURING C-2 CHECK, INSPECTION REPORTED NR 2 ENGINE PYLON AFT UPPER THREADED SLEEVE AT RIB 10 NUT BACKING OFF AND LOCK WASHER NR 103 DAMAGED, AFT PYLON-TO-WING ATTACH FITTING. REMOVED DAMAGED LOCK WASHER IAW AMM 54-51-17, SUBTASK 54-51-17-481-050, AND INSTALLESDR F3LA200600159Fitting · crackedDURING INSPECTION OF NLG UPPER SUPPORT ANTI-ROTATION LUG PER FRONTIER TC 32711-2, UPPER AFT LUG WAS FOUND TO BE CRACKED. REPLACED NOSE LANDING GEAR.SDR F3LA200600128Electrical Box · burned outFLT CREW REPORTED A STRONG ELECTRICAL-TYPE ODOR NEAR ROW 17 & AFT GALLEY AREA ENROUTE FOR LAST 30 MINS OF FLT & AFTER LANDING. FOUND SEB ON ROW 17 DEF BAD. DEFERRED LIVE TV SYS PER MEL 44-20-01AA, SEB AT 17E REPLACED PER LTV AMM 44-25-00 AND OPS CHECKED GOOSDR F3LA200600114Pressure Switch · inoperativeAIR TURNBACK. FLIGHT CREW REPORTED ENGINE 2 FUEL FILTER CLOG INDICATION. REPLACED NR 2 ENGINE MAIN FUEL FILTER AND FUEL DIFFERENTIAL PRESSURE SWITCH. RAN NR 2 ENGINE, FAULT CLEARED. OPS AND LEAK CHECKED NORMAL PER 73-34-15 PB 401 AND 73-11-10 PB 301.SDR F3LA200600088Flap System · malfunctionedON APPROACH ECAM FLAPS LOCKED. FLAPS WOULD NOT EXTEND BEYOND F2, SLATS EXTEND NORMALLY. MAINTENANCE PERFORMED TROUBLESHOOTING PER TSM 27-51-00-810-818, OPERATIONAL TEST OK. FLAP ALIGNMENT OK. NO ALIGNMENT OR FLAP FAULT NOTED DURING TEST. PER TSM 27-51-00-SDR F3LA200600084Connector · contaminatedR1 DOOR SLIDE ARMED INDICATION INOP ON ECAM AND CIDS PANEL. REMOVED R1 DOOR LINING. DISCONNECTED R1 SLIDE PROX SWITCH CONNECTOR AND FOUND GREASE CONTAMINATION. CLEANED AND RECONNECTED CONNECTOR. REINSTALLED R1 DOOR LINER. OPS CHECKED GOOD.SDR F3LA200600063Line · leakingDURING CRUISE, FLIGHT CREW REPORTED -Y- HYDRAULIC SYSTEM LEVEL LOW. AS A PRECAUTIONARY MEASURE, AN EMERGENCY WAS DECLARED UPON LANDING AT PDX. REPLACED NR 2 ENGINE YELLOW SYSTEM CASE DRAIN RETURN LINE FOR LEAKING. RAN NR 2 ENGINE. OPS AND LEAK CHECKED NORMSDR F3LA200600048Computer · failedAIR TURNBACK. FLIGHT CREW REPORTED AILERON SERVO ECAM ON CLIMB. NORMAL LAW WAS LOST. RETURNED TO DEN AND PERFORMED AN OVERWEIGHT LANDING WITHOUT INCIDENT. REPLACED ELAC NR 2 PER TSM 27-93-00-810-855. OPS CHECKED GOOD PER AMM 27-93-34. PERFORMED AFS LAND SDR F3LA200500048Lug · damagedWHILE PERFORMING A BORESCOPE INSPECTION PER EO A0-32EO-20391 (AD 2005-24-06), INSPECTION FOUND DAMAGE TO THE NOSE LANDING GEAR UPPER SUPPORT, THREE ANTI-ROTATIONAL LUGS WERE FOUND TO BE SHEARED AND ONE ANTI-ROTATIONAL LUG WAS FOUND TO BE CRACKED. THE NOSE LANSDR F3LA200500042Computer · failedFLIGHT CREW REPORTED A BURNING ELECTRICAL ODOR 20 MIN OUT FROM DEN FL390. APPROXIMATELY 20 SEC AFTER ODOR BEGAN, ECAM ANTI-ICE CAPT L & R STAT ILLUMINATED. REPLACED PROBE HEAT COMPUTER PER MM 30-31-34, PB 401. COMPLIED WITH MM 24-00-00-810-823 AND 30-31-20-SDR F3LA200500037Cooling Fan · failedFLIGHT CREW REPORTED LIVE TV SMOKE DETECTION WARNING HORN SOUNDED DURING FLIGHT. LIVE TV FAN C/B 2000VU POPPED AND WOULD NOT RESET. REPLACED AFT RACK COOLING FAN PER AMM 44-25-00, PAGE 471. OPS CHECK GOOD.SDR F3LA200500032Controller · unserviceableFLT CREW REPORTED CABIN PRESSURIZATION FLUCTUATING FOLLOWED BY NR 2 CONTROLLER FAILURE. ECAM EXCESS CABIN ALT. AT APPROX 30,000 FT & CLIMBING. NOTICED CABIN ALT SHOWING IN EXCESS OF 29,000 FT, CABIN MODE NR 1 CONTROLLER LATER ASSUMED CONTROL & CABIN PRESSURESDR F3LA200500027Transmitter · unserviceableAIR TURNBACK DUE TO FAULT, FLT/CTL ALTN LAW L&R AIL FAULT. REPLACED CAPTAIN'S SSTU 4CE1 PER AMM 27-92-41, PB 401. PERFORMED OPERATIONAL TEST PER AMM 27-92-41-710-001. REPLACED ELEV SERVO 34CE3 PER AMM 27-34-56-400-001. PERFORMED OPERATIONAL TEST, OPS CHECKSDR F3LA200500026Computer · unserviceableAIR TURNBACK DUE TO FAULT: FLT/CTL ALTN LAW PROT LOST ECAM. PERFORMED EFCS GROUND SCAN PER AMM 27-96-00-740-001. FOUND ELAC NR 1 FAULT. REPLACED ELAC NR 1 PER AMM 27-93-34, PB401. PERFORMED OPS TEST OF ELAC NR 1 PER AMM 27-93-00-710-001 AND TESTED OKAY. SDR F3LA200500019Cooling Fan · inoperativeFLIGHT CREW REPORTED LIVE TV SMOKE WARNING LIGHT DURING FLIGHT. INSPECTED LIVE TV RACK, FOUND COOLING FAN INOP (NO SMOKE PRESENT). REPLACED LTV COOLING FAN ASSY PER LTV AMM 44-25-00. OPS CHECK NORMAL.SDR F3LA200500003Duct · misinstalledON ARRIVAL, CREW REPORTED FUMES IN COCKPIT. F/A REPORTED SMELL IN AFT CABIN. A/C RETURNED TO MDW & LANDED W/O INCIDENT. REMOVED BELLY FAIRINGS FOR ACCESS TO LT PACK. INSPECTED PACK DUCTING & FOUND VASELINE ON DUCT SEALS & JOINTS. REMOVED WATER EXTRACTOR SSDR F3LA200400112Computer · inoperativeAIR TURNBACK. FLIGHT CREW REPORTED FLIGHT CONTROL RIGHT AILERON FAULT ON ECAM. PERFORMED OVERWEIGHT LANDING AND LANDED IN DEN WITHOUT INCIDENT. CABIN CREW REPORTED HYDRAULIC FLUID COMING FROM LT WING AND AN ELECTRICAL SMOKE ODOR WHEN LANDING GEAR WAS EXTENDSDR F3LA200400071Computer · inoperativeON CLIMB OUT, FLIGHT CREW REPORTED ECAM: FLT CNT. FLT CTR 1 NR 2. RAN ECAM. RETURNED TO DEN WITHOUT INCIDENT AND LANDED OVERWEIGHT. TROUBLESHOT FLT CONT 1 AND 2 IAW TSM 27-93-00-810-949. REPLACED ELAC 1 IAW AMM 27-93-34-000-001. ELAC NR 1 OPS CHECKED NSDR F3LA200400070Sleeve · damagedFLIGHT CREW REPORTED NOSE WHEEL VIBRATION ON GEAR RETRACTION. FOUND NOSE WHEEL LT BEARING AND SLEEVE DAMAGED. REMOVED SLEEVE AND INSPECTED AXLE FOR DAMAGE. NO DAMAGE NOTED. INSTALLED SERVICEABLE AXLE SLEEVE AT LT POSITION PER AMM 32-41-12-000-002 AND 32-41SDR F3LA200400065Control Unit · odorIN CRUISE CREW REPORTED SMOKE COMING FROM FLIGHT CONTROL UNIT. NO ECAMS NOTED, SMOKE/AVNCS SMOKE. QRH PROCEDURE APPLIED, EMERGENCY DECLARED. DIVERTED TO OKC & LANDED WITHOUT INCIDENT. PERFORMED INSPECTION OF FWD E&E BAY, MID & AFT E&E BAY, MID LT E&E BAY A
Back to Airbus A318-111