Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 3LA200800044Floor Support · corrodedREFERENCE NON ROUTINE 26657, DURING C3/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE MAIN DECK FLOORBEAM AT LBL 48 BETWEEN FRAMES 67 AND 68. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 5SDR F3LA200800043Floorbeam · corrodedREFERENCE NON ROUTINE 26658, DURING C3/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE MAIN DECK FLOORBEAM AT LBL 47 AND FRAME 68. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPSDR F3LA200800042Floorbeam · corrodedREFERENCE NON ROUTINE 26654, DURING C3/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE MAIN DECK FLOORBEAM AT LBL 51 AND FRAME 66. MAINTENANCE REMOVED AND REPLACED THE CORRODED FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPSDR F3LA200800068Arm · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED THE LEFT WING, NUMBER 2 FLAP DRIVE LEVER EXTENSION ARM (STRUT) FITTING, ON THE FLAP, IS CHAFING INTO THE FITTING AT THE ATTACH POINT (BOTTOM AND TOP) ON THE FLAP. MAINTENANCE BLENDED AND CHAMFERED THE EDGE OF THE FITTSDR F3LA200800066Attach Fitting · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED THE RIGHT, OUTBOARD NUMBER 3 FLAP DRIVE LEVER EXTENSION ARM FITTING WAS FOUND GOUGED WHERE IT CONNECTS TO BOTTOM OF THE DRIVE ARM. MAINTENANCE BLENDED THE DAMAGED AREA IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 5SDR F3LA200800067Hinge Fitting · damagedDURING THE C3/S1 C CHECK, INSPECTION REPORTED THE RIGHT, FORWARD, MAIN LANDING GEAR DOOR, KEEL MOUNTED HINGE FITTING, AT THE AFT LUG, HAD A NICK IN ITS BOTTOM EDGE. MAINTENANCE BLENDED THE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-73-00. PERFSDR F3LA200800041Tube · leakingDURING DESCENT & APPROACH, CREW REPORTED AN ECAM INDICATION OF LOW HYD PRESSURE & LOW HYD FLUID LEVEL FOR GREEN HYDC SYS. AN EMERGENCY DECLARED & CREW MANUALLY EXTENDED MLG. ACFT MADE AN UNEVENTFUL LANDING. MX FOUND A HYD TUBE ASSY LEAKING ON NR 1 ENGINE. SDR F3LA200800065Floor Panel · damagedDURING THE C3/S1 C CHECK, INSPECTION REPORTED THE FORWARD CARGO PIT FLOOR PANEL 131QC HAD A PUNCTURE HOLE IN ITS UPPER SURFACE. MAINTENANCE REPAIRED THE PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, PAGES 14 AND 15, STEPS A THROUGH M. UPON SDR F3LA200800058Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED A PUNCTURE WAS FOUND IN THE FORWARD CARGO COMPARTMENT FLOOR PANEL, 131VG. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, PAGES 14 AND 15, STEPS A-M. UPON COMPLETION OF SDR F3LA200800040Slide · damagedDURING C1 C CHECK, INSPECTION REPORTED THE R2 DOOR EMERGENCY ESCAPE SLIDE HAD A WORN AREA ON THE GIRT PANEL. MAINTENANCE REMOVED THE GIRT BAR FROM THE DAMAGED PANEL AND INSTALLED THE GIRT BAR IN THE NEW ESCAPE SLIDE ASSEMBLY IN ACCORDANCE WITH THE REQUIREMENTSDR F3LA200800039Slide · damagedDURING C1 C CHECK, INSPECTION REPORTED THE L2 DOOR ESCAPE SLIDE HAD A WORN AREA ON THE GIRT PANEL. MAINTENANCE REMOVED THE GIRT BAR FROM THE DAMAGED PANEL AND INSTALLED THE GIRT BAR IN A NEW ESCAPE SLIDE ASSEMBLY IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 25-SDR F3LA200800038Epsu · inoperativeDURING REMAIN OVER NIGHT MAINTENANCE, THE EMERGENCY EXIT LIGHT EPSU, FOR THE OVERWING EXITS FOR THE LEFT SIDE OF THE CABIN, FIN NR 11LN, FAILED ITS FUNCTIONAL TEST. MAINTENANCE REMOVED AND REPLACED THE EPSU IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-38 SDR F3LA200800036Light · inoperativeDURING RON MAINTENANCE, ROW 4, SEATS ABC AISLE MOUNTED EMERGENCY LIGHT FAILED ITS OPERATIONAL TEST. MAINTENANCE REMOVED AND REPLACED THE ROW 4, SEATS ABC AISLE MOUNTED EMERGENCY LIGHT IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-19 PB 401. UPON COMPLETIOSDR F3LA200800037Slide · unwanted deployDURING THE TIME THE AIRCRAFT WAS ON THE GATE OVERNIGHT, A GATE AGENT INADVERTENTLY OPENED THE R1 DOOR AND DEPLOYED THE R1 DOOR EMERGENCY ESCAPE SLIDE. MAINTENANCE REMOVED AND REPLACED THE DEPLOYED SLIDE WITH A NEW UNIT IN ACCORDANCE WITH THE REQUIREMENTS OF ASDR F3LA200800010Cabin Pressure · fluctuatesTHE FLIGHT CREW REPORTED, DURING CLIMB-OUT, PRESSURIZATION FLUCTUATED 200 FEET PER MINUTE BETWEEN FLIGHT LEVEL 350 UP TO AND LEVELING AT FLIGHT LEVEL 380. AT THE SAME TIME, THE R2 DOOR PRESSURE LIGHT FLASHED AND THE SLIDE "DISARM" ILLUMINATED, ON THE LOWER ECSDR F3LA200800009Light · inoperativeDURING AN EARLIER FLIGHT, ROW 11, SEATS ABC EMERGENCY LIGHT ASSEMBLY WAS TESTED AND FOUND INOPERATIVE. IT WAS PLACED ON MEL 1031603 ON 01/15/2008. DURING RON MAINTENANCE, THE MEL WAS CLEARED BY THE REPLACEMENT OF THE EMERGENCY LIGHT ASSEMBLY AT ROW 11, SEATSSDR F3LA200800035Floor Panel · damagedDURING C CHECK INSPECTION, CABIN FLOOR PANEL 241F, LOCATED IN THE COCKPIT, HAD THE SECOND SCREW HOLE, ON THE RIGHT FORWARD SIDE, PULLED THROUGH. MAINTENANCE REPAIRED THE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF EA A8-53R-12384. FOLLOWING COMPLETION OF TSDR F3LA200800003Epsu · inoperativeDURING PERFORMANCE OF EPSU (12WL) FUNCTIONAL TEST, THE MECHANIC NOTED A POWER SUPPLY FAULT ON THE MDCU. THE EPSU WAS REPLACED, IAW AMM 33-51-38 PB 401 AND OPERATIONS CHECKED OKAY. PART TOTAL TIMES AND TOTAL CYCLES WILL BE PROVIDED AT A LATER DATE. REFERENCESDR F3LA200800021Cylinder Damper · inoperativeDURING C CHECK INSPECTION, THE R1 EMERGENCY DOOR DAMPENER CYLINDER FAILED ITS TEST DUE TO LOW PRESSURE. MAINTENANCE CHARGED THE CYLINDER IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 52-10-00-614-001. UPON COMPLETION OF THE CHARGING, THE CYLINDER PRESSURE SDR F3LA200800020Cylinder Damper · inoperativeDURING C CHECK INSPECTION, THE R2 EMERGENCY DOOR DAMPENER CYLINDER FAILED ITS TEST DUE TO LOW PRESSURE. MAINTENANCE CHARGED THE CYLINDER IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 52-10-00-614-001. UPON COMPLETION OF THE CHARGING, THE CYLINDER PRESSURE SDR F3LA200800019Battery · inoperativeDURING C CHECK INSPECTION, THE FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY WAS FOUND DEAD. MAINTENANCE REMOVED AND REPLACED THE FLASHLIGHT BATTERY IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 25-65-00. UPON COMPLETION OF THE BATTERY REPLACEMENT, THE SDR F3LA200800001Flap System · out of alignmentDURING THE APPROACH, THE FLIGHT CREW RECEIVED AN ECAM MESSAGE THAT THE FLIGHT CONTROLS - FLAPS - WERE LOCKED DUE TO AN ALIGNMENT FAULT. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED UNEVENTFULLY. MAINTENANCE RESET THE WING TIP BREAK IN ACCORDANCE WITH AMSDR F3LA200800034Shear Plate · corrodedDURING C CHECK INSPECTION, CORROSION WAS FOUND ON THE SHEAR PLATE ON THE RIGHT SIDE, OUTBOARD FLOOR SUPPORT BETWEEN FRAMES 68 AND 70 AT STRINGER 23. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11. FOSDR F3LA200800007Inertia Reel · corrodedDURING C-CHECK INSPECTION, THE R1 DOOR SAFETY TAPE INERTIAL REEL WAS FOUND TO HAVE CORROSION ON IT. MAINTENANCE REMOVED AND REPLACED THE R1 DOOR SAFETY TAPE INERTIA REEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-40-00. FOLLOWING COMPLETION OF THE INSDR F3LA200800008Floorbeam · corrodedDURING C-CHECK INSPECTION, CORROSION WAS FOUND ON THE FLOORBEAM, AROUND THE NUT CLIP LOCATIONS (6 EACH) AT THE ATTACH POINTS OF THE FLOOR PANEL, JUST INSIDE THE L2 DOOOR. THE FLOORBEAM WAS FOUND CORRODED (OUT OF LIMITS) IN ACCORDANCE WITH THE REQUIREMENTS OF SDR F3LA200700385Engine · failedFLIGHT CREW REPORTED INFLIGHT SHUTDOWN OF NR 1 ENGINE DUE TO LOSS OF OIL QUANTITY/OIL PRESSURE. NR 1 ENGINE IS IN THE PROCESS OF BEING REPLACED. 1/7/008 FLT CREW REPORTED NT 1 ENGINE FAILURE IN FLT. SMELLED BURNING OIL, CLASS II ECAM ENGINE NR 1 OIL FILTSDR F3LA200700404Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 262FF CORRODED ON LOWER SURFACE. REMOVED AND REPLACED FLOOR PANEL 262FF IAW EO A0-53T-11996.SDR F3LA200700393Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORRODED FASTENERS THAT SECURE LIGHT TO RT WING-TO-BODY FAIRING 192DT. REMOVED AND REPLACED RT UPPER WING LIGHT COVER MOUNTING SCREWS ON PANEL NR 192DT.SDR F3LA200700392Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED RT WING-TO-BODY FAIRING 192DT HAD CORRODED FASTENERS AT LOWER SEAL. REMOVED AND REPLACED RT WING UPPER WING-TOO-BODY FAIRING PANEL NR 192DT LOWER SEAL MOUNTING SCREWS IAW 51-42-11.SDR F3LA200700403Plate · damagedDURING C4/S1 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT AFT BULKHEAD CROSSOVER BEAM HAD FASTENERS PULLING THROUGH THE CENTER PLATE. REMOVED AND REPLACED AFT CARGO COMPARTMENT AFT BULKHEAD CROSSOVER BEAM CENTER PLATE IAW SRM 51-42-11.SDR F3LA200700391Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR FWD GIRT BAR LATCH FLOOR FILLER HAD A SMALL SPOT OF CORROSION. REMOVED AND REPLACED L2 DOOR FWD GIRT BAR LATCH FILLER PANEL IAW AMM 53-42-12-PB401.SDR F3LA200700390Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED R2 DOOR AFT GIRT BAR LATCH FILLER CORRODED. REMOVED AND REPLACED R2 DOOR AFT GIRT BAR LATCH FILLER PANEL IAW AMM 53-42-12-PB401.SDR F3LA200700389Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR AFT GIRT BAR LATCH FILLER CORRODED. REMOVED AND REPLACED L2 DOOR AFT GIRT BAR LATCH FILLER IAW AMM 53-42-12-PB401.SDR F3LA200700402Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED F1 DOOR AFT GIRT BAR STOP LEVER FITTING BLANKING PLATE CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED R1 DOOR AFT GIRT BAR STOP LEVER FITTING BLANKING PLATE IAW AMM 53-12-12-PB401.SDR F3LA200700397Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT FR16, STA Y254, CORRODED ON THE TOP CAP. DETERMINED CORROSION TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED AND REPLACED FLOORBEAM FROM FR12 THRU FR24, STA 254, IAW SRM 52-42-11 AND 51-72-11.SDR F3LA200700388Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 221FF (L1 DOOR) CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED FLOOR PANEL 221FF IAW AMM 53-12-12-PB401.SDR F3LA200700387Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 222FF (R1 DOOR) CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED FLOOR PANEL 222FF IAW AMM 53-12-12-PB401.SDR F3LA200700386Dummy Rail · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED DUMMY RAIL AT Y503.2, FR 12 TO FR 16, CORRODED ON TOP. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED AND REPLACED DUMMY RAIL IAW SRM 51-42-11 AND 51-44-11.SDR F3LA200700384Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT Y1292 AND FR16, AT ATTACH POINT. REMOVED AND REPLACED FLOORBEAM AT Y1292 IAW SRM 51-42-11.SDR F3LA200700401Support Beam · bentDURING C4/S1 CHECK, INSPECTION REPORTED AFT CARGO FWD BULKHEAD PANEL SUPPORT BEAM AT APPROX STR 42L, FR47 TO FR51, BENT. REMOVED, FABRICATED AND INSTALLED REPLACEMENT SUPPORT BEAM IAW SRM 51-42-11, SRM 51-44-11, 51-75-12 AND DRAWING D53974679.SDR F3LA200700400Lock Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR SILL AFT GIRT BAR FITTING CORRODED AT LOCK FASTENER. REMOVED AND REPLACED FASTENER IAW SRM 51-42-11.SDR F3LA200700399Shear Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SHEAR PLATE AT Y1292, BETWEEN FR69 AND FR70, CORRODED. REMOVED AND REPLACED SHEAR PLATE AND FLOORBEAM IAW SRM 51-42-11 AND EA A9-53R-12329.SDR F3LA200700398Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y765, FR68, CORRODED. DETERMINED CORROSION TO BE OUT OF LIMITS IAW 53-00-14. REMOVED AND REPLACED FLOOR BEAM AT Y768 IAW SRM 51-42-11.SDR F3LA200700396Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y1292, FR68, CORRODED. DETERMINED CORROSION TO BE OUT OF LIMITS IAW SRM 53-00-14, PAR 4 B. REMOVED AND REPLACED FLOORBEAM Y1292 AT FR 68-69 IAW SRM 51-42-11 AND 51-44-11.SDR F3LA200700395Sill · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR SILL CORRODED AT VARIOUS LOCATIONS BETWEEN FR 66 AND FR 68. REMOVED AND REPLACED L2 DOOR SILL PLATE IAW SRM 51-42-11, 51-44-11, DRAWING D53480505 AND EA A9-53R-12330.SDR F3LA200700394Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y1292, FR66, CORRODED AT NUTPLATE HOLES. REMOVED AND REPLACED FLOORBEAM AT Y1292, FR66, IAW SRM 51-42-11.SDR F3LA200700383Attach Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LWR ATTACHMENT BOLT ON INBD AFT CORNER OF LAV "A" SEVERELY CORRODED. REMOVED AND REPLACED BOLT IAW AMM 25-41-41-PB401.SDR F3LA200700381Shear Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SHEAR PLATE AT BS -Y1292 BETWEEN FR 69 AND FR 70 CORRODED. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14-101. REMOVED AND INSTALLED REPLACEMENT SHEAR PLATE IAW SRM 51-42-11, SRM 51-44-11 AND EA A9-53R-12329.SDR F3LA200700380Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT BS -Y1292 HAD CORROSION AT NUT PLATE HOLES BETWEEN FR 68 AND FR 69. FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11.SDR F3LA200700378Rivet · shearedDURING C4/S1 CHECK, INSPECTION REPORTED SHEARED RIVETS ON WEB AT STA. -Y1292 BETWEEN FR68 AND FR69. REMOVED AND REPLACED RIVETS IAW A319 SRM 51-44-11, 51-46-11 AND EA A9-53R-12329.
Back to Airbus A319-111