Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200800164Strap · corrodedDURING C4 S1 CHECK INSPECTION REPORTED SURFACE CORROSION ON CARGO BAY FLOOR STRAP 2403 TO 2456 STRINGER 38R. MAINTENANCE REMOVED AND REPLACED FLOOR STRAP IN ACCORDANCE WITH SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800145Web · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND UNDER THE WEB AT FRAME 70 AND RIGHT BUTT LINE 52. MAINTENANCE REMOVED AND REPLACED THE WEB AT FRAME 70 IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE INSTALLATIONSDR F3LA200800144Seat Track · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON SEAT TRACK Y-1292, AT FUSELAGE STATION 810, ON THE RIGHT SIDE, EXTENDING FORWARD TOWARD FRAME 20. MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM SDR F3LA2008OO144Seat Track · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON SEAT TRACK Y-1292, AT FUSELAGE STATION 810, ON THE RIGHT SIDE, EXTENDING FORWARD TOWARD FRAME 20. MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM SDR F3LA200800148Floor Panel · corrodedDURING C4 S1 C CHECK, INSPECTION REPORTED CORROSION AND DAMAGE WAS FOUND ON FLOOR PANEL 261PF, UNDER THE RIGHT CORNER OF THE AFT GALLEY. MAINTENANCE REPAIRED THE CORROSION AND DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-12-00. UPON COMPLETION OSDR F3LA200800147Floor Panel · damagedDURING C4 S1 C CHECK, INSPECTION REPORTED FLOOR PANEL 222EF HAD PUNCTURE DAMAGE. MAINTENANCE REPAIRED THE PUNCTURE IN THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-12-00. UPON COMPLETION OF THE REPAIR, THE PANEL WAS INSPECTED AND FOUND ASDR F3LA200800142Cover · brokenDURING C4 S1 C CHECK, INSPECTION REPORTED A CRACK WAS FOUND IN THE EMERGENCY EXIT LIGHT LENS COVER LOCATED ON THE AFT SIDE OF THE FORWARD RIGHT DOOR FRAME. MAINTENANCE REMOVED AND REPLACED THE LENS COVER IN ACCORDANCE WITH AMM 33-51-13 PB 400-001. THE LIGHT SDR F3LA200800134Battery · inoperativeDURING HEAVY SERVICE CHECK INSPECTION REPORTED RIGHT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT BATTERY IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 33-51-38-420-052. FOLLOWING INSTALLATION THE SYSTEM WAS TSDR F3LA200800143Lamp · defectiveDURING C4 S1 C CHECK, INSPECTION REPORTED THE EMERGENCY EXIT LIGHT, ABOVE THE L1 DOOR ENTRANCE, FLICKERED. MAINTENANCE REMOVED AND REPLACED THE LAMP IN THE EMERGENCY EXIT LIGHT IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-21-11-020-50 AND AMM 33-21-11-42-050SDR F3LA200800133Stringer · damagedDURING C5 C CHECK INSPECTION REPORTED DURING PERFORMANCE OF REPAIR STRINGER WAS DAMAGED. MAINTENANCE REPAIRED THE STRINGER IN ACCORDANCE WITH THE REQUIREMENTS OF SRM A319 51-27-00 PAGE 1 AND SRM 51-42-11 PAGE 7. FOLLOWING COMPLETION OF THE REPAIR, THE STRINSDR F3LA200800132Hinge Fitting · corrodedDURING C5 C CHECK INSPECTION REPORTED CORROSION WAS FOUND IN THE MOUNTING HOLES OF THE RIGHT MAIN LANDING GEAR FORWARD HINGE BEARING SUPPORT BRACKET. MAINTENANCE REAMED FITTING ONE SIZE OVER AND INSTALLED NEW BUSHING IN ACCORDANCE WITH THE REQUIREMENTS OF EA SDR F3LA200800131Floor Panel · damagedDURING C2 C CHECK, INSPECTION REPORTED A HOLE WAS PUNCTURED INTO THE UPPER SKIN OF AFT CARGO PIT FLOOR PANEL 151VG, NEAR THE FORWARD EDGE, IN THE CENTER. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14 PB 4SDR F3LA200800129Bearing · failedDURING CRUISE, FLIGHT CREW REPORTED VIBRATION FOLLOWED BY ECAM WARNING OF NUMBER 1 ENGINE OIL FILTER CLOG, LOSS OF OIL PRESSURE, INCREASE IN OIL TEMPERATURE AND LOSS OF OIL LEVEL. THE ENGINE WAS SHUT DOWN, AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED SAFSDR FLA200800128Light · inoperativeDURING THE CABIN CHECK, THE INSPECTION DISCLOSED EMERGENCY LIGHTS WERE NOT FUNCTIONING ON TWO ROWS (ROWS 8 AND 15). MAINTENANCE REPLACED THE EMERGENCY LIGHTS ON THE TWO MALFUNCTIONING ROWS IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-19 PB 401. UPON COOMSDR Y2LA200800016Windshield · crackedWHILE ON DESCENT INTO CMH THE CAPTAIN NOTICED SPARKS SHOOTING ACROSS CA WINDSHIELD. F/O DECLARED AN EMERGENCY. SHORTLY AFTER THE WINDSHIELD HAD SPIDER WEBBED CRACKED. THE AIRCRAFT LANDED SAFELY WITHOUT ANY FURTHER ISSUES. CAPTAINS WINDSHIELD CRACKED. REMOSDR F3LA200800127Skin · damagedFOLLOWING CONTACT OF THE JET BRIDGE WITH THE L-1 DOOR, INSPECTION, DURING THE DAILY CHECK, REPORTED DAMAGE WAS FOUND TO THE LOWER, FORWARD CORNER OF THE DOOR SKIN. MAINTENANCE REPAIRED THE FORWARD LOWER CORNER OF THE L-1 DOOR IN ACCORDANCE WITH THE REQUIREMENSDR F3LA20080017Skin · damagedFOLLOWING CONTACT OF THE JET BRIDGE WITH THE L-1 DOOR, INSPECTION, DURING THE DAILY CHECK, REPORTED DAMAGE WAS FOUND TO THE LOWER, FORWARD CORNER OF THE DOOR SKIN. MAINTENANCE REPAIRED THE FORWARD LOWER CORNER OF THE L-1 DOOR IN ACCORDANCE WITH THE REQUIREMENSDR Y2LA200800015Window · crackedAT CRUISE LEFT AFT COCKPIT WINDOW OUTER PANE CRACKED WITH NUMEROUS CRACKS. APPROX 25 MIN LATER ECAM MESSAGE APPEARED L WINDOW HEAT INOP. REMOVED LEFT FIXED WINDOW PER AMM 56-11-12 PB 401 AP 2661665. INSTALLED LT FIXED WINDOW AND TORQUED PER AMM 56-11-12 PB SDR F3LA200800087Line · damagedDURING THE APPROACH, THE FLIGHT CREW REPORTED SEVERAL BIRD STRIKES (CANADIAN GEESE). ON LANDING, THE FLIGHT CREW REPORTED THE LOSS OF NORMAL BRAKING DURING THE ROLL OUT. MAINTENANCE INSPECTED THE LANDING GEAR AND FOUND BRAKE LINE 27 ON THE RIGHT MAIN LANDINGSDR F3LA200800111Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED DELAMINATION WAS FOUND ON THE TOP SURFACE OF FLOOR PANEL 252NF. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 212. FOLLOWING COMPLETION OF THE REPAIR, THE FLOORSDR F3LA200800079Sill · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED THE L-2 DOOR SILL, AFT GIRT BAR FITTING CUT OUT, SHOWED SIGNS OF CORROSION ON THE AFT, OUTBOARD SCREW HOLE. MAINTENANCE REMOVED AND REPLACED THE L-2 DOOR SILL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, SDR F3LA200800078Floor Support · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED THE RIGHT, FORWARD CARGO PIT FLOORBOARD ATTACH POINT AT STRINGER 38 HAD EVIDENCE OF CORROSION AT THE NUT PLATE HOLE LOCATIONS BETWEEN FRAME 28 AND 35. MAINTENANCE REMOVED AND REPLACED THE PROFILE PLATE IN ACCORDANCE WSDR F3LA200800082Support Angle · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED THE LEFT, SHEAR PLATE SUPPORT ANGLE, LOCATED BETWEEN FRAMES 69 AND 70, SHOWED SIGNS OF CORROSION. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE SUPPORT ANGLE, LOCATED BETWEEN FRAMES 69 AND 70, IN ACCORDANCE WITH THSDR F3LA200800081Shear Plate · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED THE RIGHT SHEAR PLATE, LOCATED BETWEEN FRAMES 69 AND 70, SHOWED SIGNS OF CORROSION. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, PARAGRAPHS 6, 7 AND 14. FSDR F3LA200800080Support Angle · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED THE RIGHT SHEAR PLATE SUPPORT ANGLE, LOCATED BETWEEN FRAMES 69 AND 70, SHOWED SIGNS OF CORROSION. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE SUPPORT ANGLE, LOCATED BETWEEN FRAMES 69 AND 70, IN ACCORDANCE WITH THSDR F3LA200800073Epsu · inoperativeDURING C1 C CHECK, INSPECTION REPORTED THE OPERATIONAL TEST OF THE EMERGENCY LIGHTS FAILED WITH A FAULT MESSAGE OF "EPSU (13WL) AFT L/DEU B." MAINTENANCE REMOVED AND REPLACED THE EPSU IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-38-000-001 AND AMM 33-51-3SDR F3LA200800074Floor Panel · damagedDURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151ZG WAS DAMAGED BEYOND REPAIRABLE LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14-400-001. FOLLOWING THE REPLACEMENT OF THE FLOOR SDR F3LA200800075Floor Panel · damagedDURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151VG WAS DAMAGED BEYOND REPARABLE LIMITS. MAINTENANCE REMOVED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14-000-001 AND REPLACED IT WITH A NEW FLOOR PANEL IN ACCORDANCE WISDR F3LA200800071Seal · corrodedDURING C5 C CHECK, MAINTENANCE REPORTED CORROSION FOUND ON RIGHT WING AILERON HINGE SEAL NEAR OUTBOARD HINGE LOCATION. MAINTENANCE REMOVED AND REPLACED AILERON SEAL IN ACCORDANCE WITH REQUIREMENTS OF A319 SRM 51-72-11 AND EA A9-57R-30062. TOUCH PAINTING PERFSDR F3LA200800070Threshold · corrodedDURING C5 C CHECK, INSPECTION REPORTED LEVEL 1 CORROSION OF AFT CARGO PIT DOOR THRESHOLD AT EIGHTEEN (18) LOCATIONS AROUND ATTACHMENT HOLES AND ADJACENT TO THRESHOLD ITSELF. MAINTENANCE REMOVED CORROSION IN ACCORDANCE WITH REQUIREMENTS OF A319 SRM 51-74-00, PSDR F3LA200800057Profile · corrodedDURING C5 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ALONG THE ATTACHMENT HOLES OF THE AFT CARGO PIT PROFILE AT FRAME 58, FROM THE RIGHT TO THE LEFT SIDE. MAINTENANCE REMOVED AND REPLACED THE PROFILE, COMMON TO FRAME 58, IN ACCORDANCE WITH THE A319 AMM SDR F3LA200800056Profile · corrodedDURING A C5 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ALONG THE ATTACHMENT HOLES OF THE AFT CARGO PIT PROFILE AT FRAME 59, FROM THE RIGHT TO THE LEFT SIDE. MAINTENANCE REMOVED AND REPLACED THE PROFILE, COMMON TO FRAME 59, IN ACCORDANCE WITH THE A319 SRSDR F3LA200800055Limiter · inoperativeDURING TAKEOFF, THE FLIGHT CREW REPORTED AN ELAC BCL2 FAULT ON THE ECAM. THE FLIGHT CREW PERFORMED AN AIR TURN BACK AND AN UNEVENTFUL LANDING WAS ACCOMPLISHED. MAINTENANCE REMOVED AND REPLACED THE NUMBER 2 BATTERY CHARGE LIMITER IN ACCORDANCE WITH THE REQUIRSDR F3LA200800049Frame · crackedDURING C7 C CHECK AND LEAK CHECKING THE RIGHT PYLON, INSPECTION REPORTED A CRACKED FRAME ON THE TOP, RIGHT SIDE OF THE PYLON, JUST AFT OF THE PRE-COOLER. MAINTENANCE REPAIRED THE CRACK IN ACCORDANCE WITH THE REQUIREMENTS OF DRAWING D54630462, A319 SRM 54-52-1SDR F3LA200800050Frame · crackedDURING C7 C CHECK AND LEAK CHECKING OF THE LEFT PYLON, INSPECTION REPORTED A CRACKED FRAME ON THE TOP, LEFT SIDE OF THE PYLON, JUST AFT OF THE PRE-COOLER. MAINTENANCE REPAIRED THE CRACK IN ACCORDANCE WITH THE REQUIREMENTS OF DRAWING D54630462, A319 SRM 54-52-SDR F3LA200800047Tat Probe · inoperativeON CLIMB-OUT, THE FLIGHT CREW REPORTED AN ECAM MESSAGE (15052) INDICATING THE CAPTAIN'S TAT SENSOR WAS INOPERATIVE. DESTINATION AIRPORT REQUIRED TAT INFORMATION FOR ANTI-ICING OPERATIONS. THE FLIGHT CREW RETURNED TO THE DEPARTURE AIRPORT AND MADE AN UNEVENTFSDR F3LA200800064Floor Panel · damagedDURING THE C3/S1 C CHECK, INSPECTION REPORTED THE AFT CARGO PIT FLOOR PANEL 161CF HAD TWO AREAS OF OUT OF LIMITS DAMAGE ON ITS TOP FACE. MAINTENANCE REPAIRED THE AFFECTED AREAS IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, PRIMED AND PAINTED THE PSDR F3LA200800048Epsu · inoperativeDURING PERFORMANCE OF EO A9-25EO-02752, REV G, INSPECTION REPORTED EMERGENCY PATHWAY LIGHTS AT ROWS 1, 2, 5 AND 6 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EPSU IN ACCORDANCE WITH THE REQUIREMENTS OF AMMM 33-51-38 PB 401. FOLLOWING COMPLETION OFSDR F3LA200800069Structure · corrodedDURING C5 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND AT THE CUT OUT OF THE AFT CARGO DOOR SELECTOR BOX. MAINTENANCE REMOVED AND REPLACED THE CORRODED SELECTOR BOX IN ACCORDANCE WITH THE A319 SRM 51-42-11, A319 SRM 52-36-15-400-001 AND EA A9-53R-30029. SDR F3LA200800054Plate · damagedDURING C7 C CHECK, WHILE PERFORMING AN INSPECTION FOR "OK TO INSTALL PARTS," INSPECTION REPORTED DAMAGE WAS FOUND TO THE CORNER PROFILE PLATE ON STRINGER 38 LT, BETWEEN FRAMES 59 AND 59. MAINTENANCE FABRICATED AND INSTALLED A DOUBLER ON THE PLATE IN ACCORDANCSDR F3LA200800062Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED THE AFT CARGO PIT FLOOR PANEL 151BE HAD A PUNCTURE ON ITS UPPER SURFACE. MAINTENANCE REPAIRED THE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00. FOLLOWING COMPLETION OF THE REPAIR, THE FLOOR PANEL WSDR F3LA200800051Cover · corrodedDURING C7 C CHECK, INSPECTION REPORTED SURFACE CORROSION WAS FOUND AROUND THE RIGHT CARGO NET HOLD DOWN BRACKET ON THE COVER PROFILE, UNDER THE FLOORBOARDS OF THE AFT CARGO PIT, AT FRAME 58. MAINTENANCE REMEDIATED THE SURFACE CORROSION ON THE COVER PROFILE, FSDR F3LA200800052Sill · corrodedDURING C7 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE SIDE WALL PROFILE AND SUPPORT STRINGER, LOCATED IN THE AFT CARGO PIT, LEFT SIDE AT FRAME 58A. MAINTENANCE BLENDED THE CORRODED STRINGER AND REMOVED AND REPLACED THE CORRODED SILL PLATE IN ACCORSDR F3LA200800061Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED THE AFT CARGO PIT FLOOR PANEL 161BF HAD DENTS AND GOUGES OUT OF LIMITS. MAINTENANCE REPAIRED THE DENTS AND GOUGES IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, TREATED, PRIMED AND PAINTED THE PANEL IN ACCOSDR F3LA200800063Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 161FF HAD DENTS OUT OF LIMITS. MAINTENANCE REPAIRED THE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-01-00, TREATED, PRIMED AND PAINTED THE PANEL IN ACCORDANCE WITH THE REQUIREMESDR F3LA200800060Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED THE FORWARD CARGO PIT FLOOR PANEL 132DG WAS DELAMINATED AND HAD OUT OF LIMIT DENTS. MAINTENANCE REPAIRED THE DELAMINATED AREA AND FILLED THE DENTS IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, PRIMED AND PSDR F3LA200800059Floor Panel · damagedDURING C3/S1 C CHECK, INSPECTION REPORTED UNACCEPTABLE DENTS AND GOUGES IN THE AFT CARGO COMPARTMENT FLOOR PANEL 162BF. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 AND PRIMED AND REPAINTED THE PANEL IN ACCORDASDR F3LA200800053Floor Panel · damagedDURING C 7 C CHECK, INSPECTION REPORTED THE FORWARD CARGO PIT PANEL 131AF HAD ITS RIGHT EDGE DAMAGED. MAINTENANCE REPAIRED THE PANEL BY FABRICATING AN ALUMINUM COVER SHEET IN ACCORDANCE WITH THE REQUIREMENTS OF EO A9-53EO-20231. THE COVER SHEET WAS INSTALLEDSDR F3LA00800046Battery Pack · failedDURING C5 C CHECK, INSPECTION REPORTED FOUR EPSU BATTERY PACKS FAILED THEIR FUNCTIONAL TEST. PART NUMBERS WERE 3214-30 AND 3214-31 AND SERIAL NUMBERS 26993, 24287, 25994, AND 45007, RESPECTIVELY. MAINTENANCE REMOVED AND REPLACED ALL FOUR BATTERY PACKS IN ACCSDR F3LA200800045Plate · corrodedREFERENCE NON ROUTINE 26838, DURING C3/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE FRAME PLATE AT FRAME 28, ON THE RIGHT SIDE, NEAR THE CARGO DOOR OPENING. MAINTENANCE REMOVED AND REPLACED THE CORRODED FRAME PLATE IN ACCORDANCE WITH THE REQUIRE
Back to Airbus A319-111