Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014070700003Girt Bar · dirtyDOOR R2 EMER SLIDE DISARMED IN FLIGHT. REMOVED DEBRIS FROM GIRT BAR ON DOOR R2.SDR CALA2014071191428Selector Valve · leakingFLUID COMING OUT AROUND NOSE STRUT. R & R LEAKING NLG STEERING SWIVEL SELECTOR VLV.SDR CALA2014071191416Door Sill · corrodedCABIN R2 DOOR SILL FRAME 66 HAS EVIDENCE OF CORROSION. R & R R2 DOOR SILL AT FRAME 66 - 68 IAW SRM51-42-11. NO SRI INSPECTION NOTED.SDR GTIA2014070401372Oxygen Mask · dislodgedOXYGEN MASKS AT SEATS 2E AND 9D HAVE FALLEN FROM THEIR COMPARTMENTS. REPACKED MASKS AT SEATS 2E & 9D AS REQUIRED IAW AMM 35-21-43. PERFORMED O2 MASK DROP CHECK IAW AMM 35-23-00 CHKS GOOD AT THIS TIME. OK FOR SERVICE.SDR YENA20140704126Actuator · faultedAIR RETURN DUE TO CABIN PRESSURIZATION FAILURE. NO PRESSURIZATION ON TAKEOFF. CLIMBED TO MAXIMUM OF 9000 FT CABIN PRESSURE MATCHED BARO DURING WHOLE FLIGHT. ECAM "ON LANDING" CAB PR OUTFLOW VALVE NOT OPEN. FOUND EMERGENCY RAM AIR INLET ACTUATOR CAUSING CABIN SDR CALA2014071191415Skin · saturatedRIGHT UPPER SKIN SHOWS SIGNS OF WATER INGRESS AT 101 INCHES FROM INBD END 5 INCHES FROM TE 7 INCHES IN DIAM. REPAIRED IAW SRM 55-21-11 RPR 5 E PARA 2 A - B CONFIG 1 FIG 205. THIS REPAIR REQUIRES INSPECTION IAW SRI 55-21-11-2-002-00 TABLE 203. FIRST INSPECTISDR CALA2014071191414Skin Panel · saturatedRIGHT ELEVATOR UPPER SKIN PANEL HAS A WATER INGRESS INDICATION AT 39 INCHES FROM INBD END 6 INCHES FROM TE 6 INCHES IN DIAM. DRILLED WITNESS HOLES, CUT OUT 28.26 SQ INCHES OF SKIN. REMOVED WATER & APPLIED A NEW CORE PLUG. THIS REPAIR REFERS TO IIR 55-21-11-SDR YENA20140703122Battery Pack · failedDURING MAINTENANCE CHECK, FOUND RT EMERGENCY BATTERY FAULT FOUND DURING EMERGENCY LIGHT TEST. R & R POWER SUPPLY BATTERY IAW AMM 33-51-38, OPS CHECKED GOOD.SDR YENA20140702123Battery Pack · failedMAINTENANCE CHECK FOUND CIDS PANEL DISPLAYS "EPSU BATTERY FWD L" FAILURE MESSAGE. R & R FWD LT EPSU BATTERY IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-710-052B.SDR USAA2014070300008Battery · dischargedFORWARD FLIGHT ATTENDANT STATION EMER FLASHLIGHT SHOWING NOT CHARGED. REPLACED FWD EMER FLASHLIGHT BATTERY.SDR YENA20140701124Girt Bar · out of adjustAFTER TAKEOFF, AFT RT DOOR SLIDE WILL NOT STAY ARMED. R & R DOOR SLIDE IAW 25-62-44-400-007-A, OPS CHECKED GOOD. WHILE ARMING AND DISARMING R2 DOOR SLIDE ARMING LEVER STILL SPONGY. FOUND R2 DOOR FWD GIRT BAR FITTING OUT OF ADJUSTMENT. ADJUSTED IAW AMM 52SDR CALA2014070191396Transmitter · faultyCAPTAINS NOSE WHEEL STEERING PEDALS DISCONNECT PUSH BUTTON INOPERATIVE WHEEL. FIRST OFFICERS BUTTON OPERATES NORMAL. TRIED NEW TRANSMITTER BUT WOULD NOT PASS FUNCTION TEST AMM 32-51-00-720-007. NEW TRANSMITTER IS BAD FROM STOCK. INSTALLED ORIGINAL TRANSMITTSDR CALA2014070191395Door Sill · corrodedL2 DOOR SILL HAS CORROSION AT FRAME 66 STRINGER L23 BOTTOM SURFACE. CORROSION FOUND OUT OF LIMITS IAW SRM 53-41-14 PB 102 FIG 101. 0.035 LOSS REPAIRED SILL IAW SRM53-41-14 PB202 P5-A FIG 101 PRP 1 SHEET 2 CAT A REPAIR NO FURTHER ACTION.SDR CALA2014070191394Cover · missingPLASTIC COVER AT LT MLG HINGE POINT IS MISSING. INTERIM REPAIR ACCOMPLISHED. REQUIRES DAILY INSPECTION TO ENSURE INTEGRITY OF THE REPAIR & A NEW LT MLG LEG BEARING BLANKING PLUG MUST BE INSTALLED WITHIN 25 FLT HRS IAW ECRA 3211-01346. DL2030 CREATED TO MONISDR YENA20140701121Bearing · wornACFT RETURN TO DEPARTURE DUE TO VIBRATION FELT DURING INITIAL CLIMB. VIBRATION STOPPED WHEN ACFT CLEAN, HAD SLIGHT VIBRATION WHILE CONFIGURING LANDING. PERFORM TSM TASK 27-64-00-810-801A. FOUND UPPER SPHERICAL BEARING ON LINK AT ENG NR 1 PYLON FAIRING, MOVABSDR GTIA2014063001369Knob · missingL1 MEGAPHONE VOLUME KNOB MISSING. R & R LI MEGAPHONE IAW EMERGENCY EQUIPMENT DWG NK320-232-EQ.SDR USAA2014070100009Power Supply · inoperative90WL2, 90WL1 & SEAT 4C EMER EXIT LIGHTS INOPERATIVE. REPLACED EMER POWER SUPPLY UNIT 10WL IAW AMM 33-51-38-400-001-A.SDR CALA2014063091367Battery Pack · malfunctionedIAW JC 4-2020 ITEM 26 FAILS CABIN EMER LIGHTING CHECK. MSG EPSU INT LOAD AFT LT. RESET EMER POWER SUPPLY BATTERY PACK. OPERATIONS CHECKED GOOD IAW MM 33-51-00 PG 501.SDR CALA2014063091366Sign · inoperativeEXIT SIGN ABOVE FWD LT ENTRY DOOR INOPERATIVE. REPLACED LT FWD OVER DOOR EMER LIGHT ASSEMBLY. OPERATIONS CHECKED GOOD.SDR CALA2014063091372Computer · faultyFUEL QTY DISCREPANCY BETWEEN COCKPIT & REFUELING PANEL. STICKED ALL TANKS, COCKPIT GAUGES READ CORRECTLY, UNDERWING GAUGES READING INCORRECTLY. REPLACED FQIC IAW MM 28-4 2-34 & STUCK TANKS, FOUND TO BE WITHIN LIMITS IAW FUELING MANUAL.SDR CALA2014063091371Button · inoperativeCAPTAIN'S NOSE WHEEL STEERING PEDALS DISCONNECT PUSH BUTTON INOPERATIVE. FIRST OFFICERS BUTTON, OPERATIONS NORMAL.SDR CALA2014063091370Oxygen System · lowCREW OXYGEN SYS LOW. SERVICED CREW OXYGEN IAW AMM 12-14-35-0301. OPERATIONS & LEAK CHECKED OK. PRESS PRIOR TO SERVICING 1250PSI.SDR CALA2014063091369Switch · unsecureRIGHT RETRACTABLE LAND LIGHT SWITCH NEEDS SECURING. SECURED RT RETRACTABLE LANDING LIGHT SWITCH. OPERATIONS CHECKED OK.SDR CALA2014063091368Structure · crackedLEFT MLG WW LT SIDE TORSION BOX LOWER SIDE SHELL HORIZONTAL FLANGE CRACKED AT FASTENER HOLE COMMON TO FRAME 43. REPAIR WAS ACCOMPLISHED IAW ECRA 5330-04864 REV A. THIS ECRA ACCOMPLISHED SBA 320-53-1251 TO BOTH THE LT & RT SIDES.SDR USAA2014063000012Lens · missingEMERGENCY LIGHT ASSEMBLY LENS IS MISSING AT ROW 11 LT. REPLACED EMER LIGHT LENS AT ROW 11 LT.SDR CALA2014062791345Light · brokenR2 DOOR SLIDE LIGHT BROKEN. R & R BULB IAW MM 52-73-21-400-002. OPERATIONS CHECKED GOOD IAW MM 52-73-00-710-001-A. IDT TASK.SDR USAA2014071000009Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 251FF BETWEEN FRAME 51 TO 54, Z-500, Y=0. REPAIRED FLOOR PANEL 251FF IAW IRM 9701 REVISION G.SDR CALA2014062791344Door Seal · dirtyHISSING NOISE AT EMER EXIT PLUG DOOR AT 20A. INSPECTED & CLEANED FWD LT HATCH SEAL & SEAL MATING SURFACE & OUTSIDE HANDLE GASKET IAW MT 53-004 & MM 52-21-11-000-001-A. NO SEAL OR GASKET DAMAGE NOTED.SDR USAA2014062700020Floor Panel · delaminatedS2 CHECK AREA OF DELAMINATION ON FLOOR PANEL 232YF BETWEEN FRAME 24 TO 28, Z-500, Y1028. REPLACED FLOOR PANEL 232YF IAW IRM 9701 REVISION G.SDR USAA2014062700019Floor Panel · delaminatedS2 CHECK AREA OF DELAMINATION ON FLOOR PANEL 241FF BETWEEN FRAME 35 TO 36, Z-500, Y510. REPLACED FLOOR PANEL 241FF IAW IRM 9701 REVISION G.SDR USAA2014062700014Floor Panel · delaminatedS2 CHECK UPPER SURFACE OF FLOOR PANEL 251SF IS DELAMINATED BETWEEN FRAME 58 TO 62, Z-500, Y254. REPLACED FLOOR PANEL 251SF IAW IRM 9701, REVISION G.SDR USAA2014062700013Floor Panel · delaminatedS2 CHECK UPPER SURFACE OF FLOOR PANEL 241EF IS DELAMINATED AT AFT OTBD END BETWEEN FRAME 36 TO 42, Z-500, Y=0. REPLACED FLOOR PANEL 241EF IAW IRM 9701, REVISION G.SDR USAA2014062700012Floor Panel · peelingS2 CHECK UPPER SURFACE OF FLOOR PANEL 232WF IS PEELING AT FRAME 32 TO 35, Z-500, -Y510. REPLACED FLOOR PANEL 232WF IAW IRM 9701, REVISION G.SDR USAA2014062700008Oxygen Bottle · low pressureCREW O2 PRESS AT 120 PSI. SERVICED CREW O2 TO 1500 PSI IAW AMM CHAPTER 20-3512 & INSTALLED BOTTLE IAW AMM 35-11-41-0401.SDR USAA2014062600020Floor Panel · peelingS2 CHECK PEELING ON UPPER SURFACE OF FLOOR PANEL 242LF BETWEEN FRAME 46 TO 47, Z-500, -Y1028. REPLACED FLOOR PANEL 242LF IAW 9701, REVISION G.SDR USAA2014062600019Floor Panel · delaminatedS2 CHECK DELAMINATION ON UPPER SURFACE AT AFT INBD CORNER OF FLOOR PANEL 241GF BETWEEN FRAME 36 TO 42, STRINGER 23L, Z-500, Y1028. REPLACED FLOOR PANEL 241GF IAW 9701, REVISION G.SDR GTIA2014062501363Bottle · low pressureL2 DOOR ASSIST BOTTLE 1500 PSI. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM-52-10-00-614-001-A.SDR YENA20140625117Light · inoperativeDURING PRE-FLIGHT CHECK, F/A FOUND THE EMERGENCY FLOOR LIGHT ROW 9 RT INOPERATIVE. REPLACED EMERGENCY LENS, RED, COVER. OPS CHECK NORMAL IAW AMM 33-51-11.SDR USAA2014062600022Floor Panel · delaminatedS2 CHECK DELAMINATION AT FWD OTBD CORNER OF FLOOR PANEL 262HG BETWEEN FRAME 68 TO 70, Z-500 & BETWEEN Y1162.5 TO Y-1162.5. REPLACED FLOOR PANEL 262HG IAW 9701, REVISION G.SDR USAA2014062600021Floor Panel · peelingS2 CHECK PEELING ON UPPER SURFACE OF FLOOR PANEL 251SF BETWEEN FRAME 58 TO 62, Z-500, Y510. REPLACED FLOOR PANEL 251SF IAW 9701, REVISION G.SDR USAA2014062600018Floor Panel · damagedS2 CHECK SURFACE DAMAGE ON TOP FWD END OF FLOOR PANEL 222CF BETWEEN FRAME 12 TO 16, STRINGER 23R, Z-500 & BETWEEN Y=0 TO -Y1497. REPLACED FLOOR PANEL 222CF IAW 9701, REVISION G.SDR GTIA2014062401362Oxygen Mask · leakingF/O OXYGEN MASK EXPANDABLE HEAD STRAP LEAKING WHEN EXPANDING FOR USE. R & R F/O OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR GTIA2014062401361Oxygen Mask · inoperativePRIMARY OBSERVER SEAT OXYGEN MASK INOPERATIVE. R & R PRIMARY OBSERVER SEAT OXYGEN MASK. OPS CHECK OK IAW AMM 35-12-41.SDR USAA2014062700016Battery Pack · dischargedAFT LT FLIGHT ATTENDANT JUMP SEAT OTBD EMER FLASHLIGHT NOT BLINKING. REPLACED BATTERY PACK, OPERATIONS CHECKED GOOD.SDR CALA2014062491332Warning System · false activationYAW DAMPER 2 FAULT AFTER ENG START. CYCLED 2 FAC SWITCH & RESET CB FAULT CLEARED & BITE CHECKED OK IAW AMM22-96-00.SDR CALA2014062091316Door Sill · corrodedL2 DOOR SILL IS CORRODED AT 7 LOCATIONS AT FWD & AFT ENDS. AFTER BLENDING CORROSION AT 7 LOCATIONS MATERIAL LOSS WAS .065 OUT OF LIMITS IAW SRM 53-41-14 FIG 101. ORIGINAL MATERIAL T=.177 & REMAINING T=.112. R & R L2 DOOR SILL IAW SRM 53-41-14 FIG 101.SDR CALA2014062091317Connector · dirtyNOSE WHEEL STEERING FAULT. FLIGHT CREW CLEARED MSG ON GND WITH NWS SWITCH CYCLE. PFR MSG STEERING ELECTRO HYD MODULE. TWICE WITH BSCU 1 & BSCU2 AS SOURCE. NO PREVIOUS HISTORY. CLEANED & INSPECTED STEERING MODULE CONNECTOR. SYS OPERATIONS CHECKED NORMAL.SDR CALA2014062091315Stringer · corrodedSTRINGER 42R IS CORRODED BETWEEN FRAME 63 & 64 IN AFT CARGO COMPARTMENT. CORROSION WAS OUT OF LIMITS FOR BLENDING. CUT OUT STRINGER BETWEEN FRAME 62 & 63 & REMOVED FACTORY INSTALLED SPLICE. INSTALLED NEW STRINGER & SPLICE. THIS REPAIR REQUIRES RE-INSPECTISDR CALA2014062091314Door Sill · corrodedR2 DOOR SILL IS CORRODED ALONG ENTIRE LENGTH. FOUND CORROSION TO BE OUT OF LIMITS FOR BLENDING. R & R R2 DOOR SILL & SPLICE BETWEEN FRAME 66 - 68. RESTORED THE AREA, HIS IS A MAJOR REPAIR.SDR CALA2014062091311Cover · unsecureSLIDE PACK AT DOOR 1L IS PREVENTING THE DOOR FROM BEING CLOSED. SECURED DOOR 1L DECORATIVE COVER IAW AMM 25-62-44-000-012-A.
Back to Airbus A320-232