Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA992254Stringer · corrodedTUL - FOUND STRINGER 27L CORRODED INSIDE STATION 720E PLUS 5 INCH THROUGH 720E PLUS 7 INCH. REMOVED DAMAGED STRINGER 27L FROM STATION 720E PLUS 10 INCHES AND STATION 720F PLUS 10 INCH AND INSTALLED SPLICES AND FILLER PER SRM 53-10-3 PAGE 3. (M)SDR AALA982250Floorbeam · corrodedTUL - FOUND TOP OF FLOORBEAM CORRODED STATION 380 RBL 14 TO RBL 67. REMOVED CORROSION FROM TOP OF FLOORBEAM, AREA AT RBL 33.5 WAS BEYOND LIMITS. FABRICATED AND INSTALLED REPAIR ANGLES PER AARD 53-10-07-02 PAGE 1-4 PARA B, SUBSITUTED MAT PER SRM 51-20-1 TREATSDR AALA982249Stiffener · crackedTUL - FOUND CRACK IN STIFFENER JUST FORWARD AND BELOW LEFT FORWARD TENSION TIE BOLT. REPLACED STIFFENER WITH NEW STIFFENER. (M)SDR AALA982202Frame · dentedTUL - FOUND STATION 950C FRAME HAS DENT WITH BULGE AT FORWARD WEB ABOVE STRINGER 25L. INSTALLED DOUBLER REPAIR PER SRM 53-00-00-01. (M)SDR AALA982198Floorbeam · corrodedTUL - FOUND CORROSION ON FLOORBEAM STATION 380 RBL 20 TO RBL 45. CUT OUT UPPER PORTION OF FLOORBEAM TO REMOVE CORROSION AND INSTALLED DOUBLER REPAIR PER SRM 53-10-8. (M)SDR AALA982177Floorbeam · misdrilledTUL - FLOORBEAM STATION 344 LEFT TOP FORWARD FLANGE HAS HOLE WITH NO EDGE DISTANCE. INSTALLED FLOORBEAM REPAIR IAW ESO 11697, DATED 11-17-98. (M)SDR AALA982158Spar · corrodedTUL - FOUND CORROSION ON FORWARD SPAR LOWER CHORD PLATE FS 514. INSTALLED REPAIR STRAP OVER BLENDOUT PER AARD 57-30-00-2 PAGE 1-3. (M)SDR AALA982297Frame · deformedTUL - FOUND BELLFRAME BEN AND DEFORMED AT BS 990 BETWEEN STRINGER 27L AND 26L. CUTOUT DAMAGED AREA, INSTALLED OUTSIDE DOUBLER SRM 53-10-4. BELLFRAME WAS ALODINED AND PRIMED AND INSTALLED WET WITH SEALANT USED H6426 HI-LOCKS. (M)SDR AALA982272Shear Tie · corrodedTUL - FOUND SHEAR TIE CORRODED AFT SIDE STATION 1148, BETWEEN STRINGER 30R AND 29R. REMOVED CORROSION PER SRM 51-10-6 ALODINED AND PRIMED. (M)SDR GAIA98129Fasteners · missingDURING ROUTINE INSPECTION NUMEROUS CENTER ROWS, RIVETS WERE FOUND MISSING FROM MAIN CARGO DOOR (MCD) LAP SEAM AREA, 10L, BETWEEN FRAMES. REF STC ST00015AT, ATAZ CARGO DOOR MODIFICATION. REPLACED MISSING RIVETS PER STC NR ST00015AT, ATAZ DRAWINGS. AIRCRAFT WSDR GAIA98127Fire Bottle · dischargedDURING CLIMB-OUT OF TOL, THE LEFT FIRE BOTTLE DISCHARGE LIGHT ILLUMINATED. THE AIRCRAFT CONTINUED ITS LEG TO JFK AND LANDED WITHOUT FURTHER PROBLEMS. REMOVED AND REPLACED THE LEFT HRD FIRE EXTINGUISHER BOTTLE IAW BOEING MM 26-21-1. RETURNED TO AIRCRAFT TO SSDR AALA982279Stringer · gougedTUL - FOUND STRINGER 2R GOUGED AT END FASTENER TO END FITTING UNDER HAT SECTION STATION 740 STRINGER 2R. CUT OUT DAMAGED FLANGE AND INSTALLED EXTENDED LENGTH END FITTING PER ESO 11697, DATED 12/7/98. (M)SDR AALA982150Wire · failedDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS IN COACH CABIN INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT WIRING. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA982149Light · defectiveDFW - DURING OVERNIGHT CHECK, AIR STAIR EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED AIR STAIR EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA992281Stringer · crackedTUL - FOUND STRINGER 15L CRACKED AT FORWARD FASTENER STATION 720B. CUT OUT DAMAGED SECTION STRINGER 15L. INSTALLED SPLICE REPAIR PER SRM 53-10-3. (M)SDR AALA982288Skin · corrodedTUL - FOUND CORROSION UNDER SEALER AROUND LIGHT PAN STATION 720 B - 720C STRINGER 15L. REMOVED CORROSION, REPAIRED SKIN AT WING ICE LIGHT CUT OUT PER SRM 53-30-3. (M)SDR AALA982278Stringer · crackedTUL - FOUND STRINGER 15L AFT OF WING ICE LIGHT, CRACKED AT FORWARD FASTENER STATION 720C. REMOVED DAMAGED SECTION OF STRINGER 15L. INSTALLED SPLICE REPAIR PER SRM 53-10-3. (M)SDR AALA982191Frame · dentedTUL - STATION 520 BELL FRAME DENTED BETWEEN STRINGER 23L AND 25L. CUT OUT DAMAGE AT TWO LOCATIONS. 1 INCH BY 4 INCH AT STRINGER 23L, 1 INCH BY 3 INCH AT STRINGER 25L. EACH AREA HAD SEPARATE DOUBLERS INSTALLED PER SRM 51-40-3 USING 7075-T6 .050 THICK DOUBLERSDR EISA98284Overheat Light · illuminatedSHORTLY AFTER SELECTING WING ANTI-ICE ON, THE LOWER AFT BODY OVERHEAT LIGHT ILLUMINATED, EXTINGUISHED AFTER TURNING OFF ENGINE NR 3 ANTI-ICE. ENGINE NR 1 OPENED NORMAL. OPS CHECKED IN AIR AND GROUND MODES, OPS CHECKED NORMAL IAW MM CHAPTER 26. (M)SDR AALA982295Frame · dentedTUL - FOUND BELLFRAME DENTED STATION 540 STRINGER 24 LEFT ON TOP FLANGE. INSTALLED DOUBLER PER SRM 51-40-3 SIZE 7 INCHES BY 4 INCHES, USING 7075-T6 MATERIAL, .063 INCH THICK, WITH 21 MS 20470D .1875 FASTENERS, 4 OF WHICH ARE .24 INCH, IN 3 FASTENER ROWS. (M)SDR AALA982284Clip · corrodedTUL - FOUND STRINGER 26L SUPPORT CLIP CORRODED STATION 555. REMOVED AND REPLACED STRINGER SUPPORT CLIP PER SRM 51-10-1 PAGE 4. (M)SDR AALA982277Stringer · crackedTUL - FOUND STRINGER 15R STATION 720B CRACKED JUST FORWARD OF ICE LIGHT. REPAIRED DAMAGED STRINGER BY SPLICING SECTION FROM 720A PLUS 10, TO ICE LIGHT BOX, AS PER SRM 53-10-3 PAGE 3-4B. (M)SDR AALA982271Shear Tie · corrodedTUL - FOUND SHEAR TIE CORRODED AT STATION 990 BETWEEN STRIGNER 28L-29L. REMOVED CORROSION SHEAR TIE AND INSTALLED REPLACEMENT SHEAR TIE PER SRM 53-10-4. (M)SDR AALA982270Stringer · corrodedTUL - FOUND STRINGER 27 LEFT CORRODED AT FASTENER HOSE STATION 703. REPAIRED PER SRM 53-10-3 PAGE 3-4B. (M)SDR AALA982269Stringer · corrodedTUL - FOUND FSS 212-223 ABOVE AND AFT A/I DUCT, 4 EACH GROUNDS CORRODED ON STRINGER. REMOVED CORRODED SECTION OF STRINGER. INSTALLED SPLICE REPAIR PER SRM 51-40-4. (M)SDR AALA982268Stringer · corrodedTUL - FOUND 4 EACH GROUNDS CORRODED ON STRINGER ABOVE AND AFT A/I DUCT BETWEEN STATION 180-196. REMOVED CORRODED SECTION OF STRINGER. INSTALLED SPLICE REPAIR PER SRM 51-40-4. (M)SDR AALA982263Skin · corrodedTUL - FOUND CORROSION ON FUSELAGE SKIN AROUND LIGHT PAN 720B-720C AT STRINGER 15R. ACCOMPLISHED ICE LIGHT CUT OUT REPAIR DOUBLER INSTALLATION PER ESO 11697 DATED 12/2/98. (M)SDR AALA982144Light · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP AFT OF FORWARD GALLEY HAS TWO LAMPS UNDERNEATH EXIT IDENTIFIER INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP NEXT TO FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATIOSDR AALA982009Frame · dentedTUL - FOUND STATION 520 BELTFRAME DENTED STRINGER 23R - STRINGER 25R. REMOVED DAMAGE TREATED AND PRIMED AIND INSTALLED FRAME REPAIR PER SRM 53-10-4 FIG 1 DOUBLER 7075-T6 .050. (M)SDR AALA982300Frame · dentedTUL - FOUND BELLFRAME DENTED TOP FLANGE STATION 680 BETWEEN STRINGER 22L TO STRINGER 25L. INSTALLED REPAIR PER SRM 51-40-3 USING 7075-T6 .063 INCH THICK, 6.5 INCH BY 4 INCH USING SIXTEEN .1875 UNIVERSAL D RIVETS AND FIVE .25 INCH UNIVERSAL D RIVETS AND THREE SDR AALA982299Frame · dentedTUL - FOUND BELLFRAME DENTED TOP FLANGE FROM STRINGER 23L TO INBOARD SIDE OF STRINGER 25L STATION 600. INSTALLED REPAIR PER SRM 51-40-3 USING 7075-T6 .063 THICK, 25 INCH BY 4 INCH WIDE, USING 61 EACH .1875 UNIVERSAL D RIVETS AND 4 EACH .25 INCH UNIVERSAL D RISDR AALA982280Frame · crackedTUL - FOUND FUSELAGE FRAME AT STATION 804.5, OUTBOARD CHORD CRACKED IN RADIUS AT STRINGER 14L. INSTALLED NEW OUTBOARD CHORD SECTION PER SRM 51-10-1 PAGE 4. (M)SDR AALA982274Trunnion · corrodedTUL - FOUND LEFT NLG TRUNNION BORE CORRODED. INSTALLED NEW LEFT NLG TRUNNION. (M)SDR AALA982195Stringer · corrodedTUL - STATION 490-500 STRINGER 28R CORRODED INSIDE. REMOVED DAMAGED SECTION OF STRINGER. INSTALLED SPLICE REPAIR PER SRM 53-10-3 FIG 1. (M)SDR AALA982188Frame · dentedTUL - STATION 540 BELL FRAME HAS DENT BETWEEN STRINGER 24L AND 25L. REMOVED DAMAGED AREA. INSTALLED .1875 RIVET PER ESO 11697, DATED 12-3-98. (M)SDR AALA982169Skin · corrodedTUL - FOUND FUSE SKIN CORRODED OUTBOARD STRINGER 28R STATION 490-500, BETWEEN STRINGER AND INTERCOSTAL. REMOVED DAMAGED AREA OF SKIN. INSTALLED DOUBLER REPAIR PER SRM 53-30-3 FIG 3. (M)SDR AALA982296Frame · dentedTUL - FOUND BELLFRAME DENTED ALONG TOP FLANGE FROM STRINGER 22R TO 24R, STATION 500. DENTS AT STRINGER 23R AND 22R WITHIN LIMITS PER AARD 53-10-10-07-3 PAGE 1. CUTOUT DENT AT STRINGER 24R AND INSTALLED DOUBLER 7075-T6 REPAIR PER 51-40-3 PAGE 3, CUT OUT AREA SDR AALA982285Link · corrodedTUL - FOUND 4 LARGE HOLES HAVE FRETTING CORROSION. REMOVED CORROSION TREATED AND INSTALLED REPAIR BUSINGS AND WASHERS PER ESO 11697 DATED 11-30-98. (M)SDR AALA982283Skin · corrodedTUL - FOUND CORROSION AT STRINGER 874 LBL 28 ON LOWER SKIN WING CENTER SECTION. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER SRM 57-30-3 PAGE 22. (M)SDR AALA982267Shear Tie · corrodedTUL - FOUND SHEAR TIE CORRODED AT BS 1110 BETWEEN STRINGER 26L AND 27L. INSTALLED NEW SHEAR TIE, WORKED PER SRM 53-10-4 FIG 11. (M)SDR AALA982197Stringer · corrodedTUL - FOUND STRINGER 29L HAS CORROSION EXTENDING FROM 7 FASTENERS IN OUTBOARD FLANGE AND IN PREVIOUSLY REWORKED AREA. REPAIRED STRINGER PER ESO 11697, DATED 11/2/98. (M)SDR AALA982182Frame · dentedTUL - STATION 560 BELT FRAME DENTED BETWEEN STRINGER 23L AND 25L. INSTALLED BELT FRAME REPAIR PER SRM 51-40-3 USING 54, .1875 INCH HI-LOCKS AND 4 EACH .25 INCH HI-LOCKS. (M)SDR AALA982012Stringer · gougedTUL - DEEP GOUGE IN STRINGER 25 LEFT AT STATION 520. CUT OUT DAMAGED AREA OF STRINGER 25L AND INSTALLED STRINGER SPLICE REPAIR PER SRM 53-10-3. (M)SDR AALA982008Floorbeam · wornTUL - FLOORBEAM UPPER CAP WORN STATION 360, BL 0. REPAIRED STATION 360 FLOORBEAM UPPER CAP AT BL 0 PER SRM 53-10-8. (M)SDR AALA982129Wire · failedDFW - DURING OVERNIGHT MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHTING IN COACH CABIN INOPERATIVE. REPAIRED WIRING IN COACH CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA982123Light · defectiveDTW - DURING OVERWEIGHT MAINTENANCE, AFT STAIR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT AIR STAIR EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR EISA98262Switch · out of adjustCARGO DOOR ARM/DISARM LIGHT CAME ON AFTER TAKEOFF FROM MCO, UNABLE TO PRESSURIZE CARGO WARNING LIGHT OFF. AIR TURN BACK TO MCO, GENERATED FROM PILOT REPORT. ADJUST S17 SWITCH (LOCK BAR SWITCH) OPS CHECK NORMAL PER PEMCO MM. RAN NR 3 ENGINE AND PRESSURIZED NSDR EISA98252Light · inoperativePOST FLIGHT, FOUND EMERGENCY EXIT LIGHT OVER L-1 DOOR DIM. GENERATED BY MAINTENANCE REPORT. REMOVED AND REPLACED L-1 DOOR EMERGENCY LIGHT ASSY. OPS CHECK GOOD PER MM 33-50. (M)SDR AALA982116Switch · malfunctionedMIA - FLT 2157 - AFTER TAKEOFF MIA EN ROUTE TO CUN WITH GEAR RETRACTED RIGHT MAIN GEAR DOOR STILL OPEN. CYCLED GEAR SEVERAL TIMES, RIGHT MAIN DOOR STILL INDICATED OPEN. AFTER CYCLING GEAR HANDLE TO UP POSITION AFTER GEAR ALREADY RETRACTED, GOT LIGHTS TO EXTISDR EISA98253Wire · brokenMAIN CARGO DOOR LIGHT ILLUMINATED DURING FLIGHT, WITH A POSSIBLE PRESSURE LOSS, RESULTING IN AN AIR TURN BACK TO EDI. FOUND BROKEN WIRE REPAIRED IAW MM CHAPTER 20 AND 52. OPS CHECK GOOD OK FOR SERVICE. (M)
Back to Boeing 727-223