Boeing 727-22C
Service difficulty reports · 2,328
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '72722C' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '72722C' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS96220539Expansion Link · corrodedINSPECTION TYPE SI, CORROSION ON EXPANSION LINK STA 740 TO 760 LBL 25 WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, REPAIRED EXPANSION LINK PER SRM 51-10-1, 51-30-2.SDR UPS96220538Expanson Link · corrodedINSPECTION TYPE SI, CORROSION ON EXPANSION LINK STA 850 TO 870 LBL 45 WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, REPLACED EXPANSION LINK PER SRM 51-10-1, 51-30-5, 51-30-8, 51-30-2, 51-20-4.SDR RAAAB296030Skin · crackedDURING SCHEDULED INSPECTION PER SB 53-054, FOUND MID CABIN DOOR UPPER HINGE CUT OUT CRACKED. REPAIRED PER SB 727-53-054 REV 1 AND BOEING MSG M7272-53-2800. (M)SDR UPS96220529Web · corrodedINSPECTION TYPE SI, CRACK ON FLOOR WEB STA 480 WL 208 LBL 55 AREA MARKED. WHILE WORKING CRACK FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 51-10-1. REPAIRED PER SRM 51-40-2, 51-10-2 AND M/M 51-21-151.SDR UPS96220527Support · corrodedINSPECTION TYPE SI, CORROSION ON COCKPIT ENTRY SUPPORT STA 304 WL 208 LBL 4,9 RBL 3,8 AREA MARKED. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-1, FARICATED REPLACEMENT SUPPORT PER SRM 51-20-1, 51-30-8 AND 51-30-5. REPLACED FLOOR SUPPORT AT BS 304 LBL 1SDR UPS96220525Stiffener · corrodedINSPECTION TYPE SI, CORROSION ON EXPANSION LINK STA 740 TO 760 RBL 25 WL 208 IN CENTER CHANNEL AT FWD END. FOUND EXPANSION LINK TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED AND REPLACED EXPANSION LINK AT BS 740 TO 760 RBL 25 WL 208 PER SRM 51-10-1, 51-30-4,SDR UPS96220547Channel · corrodedINSPECTION TYPE SI, CORROSION ON HAT CHANNEL FROM BS 300 TO 342, RBL 12, WL 208. REMOVED AND REPLACED HAT CHANNEL IAW SRM 51-30-2, 53-10-1, 51-40-4.SDR UPS96220546Spar · corrodedINSPECTION TYPE SI, CORROSION R/W UPPER REAR SPAR CHORD AT WBL 86 JUST ABOVE NR 3 ENGINE FUEL SHUTOFF VALVE. REPAIRED UPPER REAR SPAR CHORD IAW SB 727-57-0145, SRM 57-10-6 AND BOEING DRAWING 65-C19647.SDR UPS96220545Frame · corrodedINSPECTION TYPE SI, CORROSION ON FRAME CHORD STA 312, RBL 43, WL 178. REMOVED AND REPLACED CHORD IAW SRM 53-10-1, 51-40-3, 51-30-2.SDR UPS96220544Frame · corrodedINSPECTION TYPE SI, CORROSION ON BS 351 WEB AT RBL 37 AND 47, WL 168 BELOW DOGHOUSE FLOOR. REMOVED DAMAGED WEB SECTION AND INSTALLED NEW SECTION IAW SRM 51-40-2. ALSO, REPLACED CORRODED SHEAR TIE AT STR 24R DUE TO CORROSION OUT OF LIMITS.SDR UPS96220543Stiffener · corrodedINSPECTION TYPE SI, CORROSION ON DOGHOUSE FLOOR SUPPORT AT BS 351, RBL 20 AND RBL 30, WL 170. REMOVED AND REPLACED STIFFENER/FLOOR SUPPORT IAW SRM 51-30-2, 53-10-1, 51-30-5.SDR UPS96220542Crease Beam · corrodedINSPECTION TYPE SI, CORRROSION ON STA 1176 CREASE BEAM FROM LBL 25 TO 55 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 51-10-1. REMOVED CREASE BEAM CHORD AND REPLACED PER SRM 51-30-2.SDR UPS96220541Rib · crackedINSPECTION TYPE SI, NR 8 SLAT I/B TRACK SUPPORT STRUCTURE O/B RIB IS CRACKED IN 2 PLACES. REMOVED AND REPLACED NR 8 SLAT I/B TRACK SUPPORT FITTINGS AND WEBS PER SRM 51-30-2.SDR UPS96220540Intercostal · corrodedINSPECTION TYPE SI, CORROSION ON BOTTOM OF INTERCOSTAL STA 219.8 TO STA 227 LBL 42 WL 227. REMOVED INTERCOSTAL, FABRICATED AND INSTALLED NEW INTERCOSTAL IAW SRM 51-10-2, 51-30-2, 51-20-4.SDR UPS96220534Floor Support · corrodedINSPECTION TYPE SI, CORROSION ON LAV FLOOR SUPPORT STA 315 WL 208 RBL 17, 20, 24, 27, 30, 39 AREAS MARKED. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-10-1, 51-30-2, 53-10-1, 51-30-5.SDR UPS96220533Angle · crackedINSPECTION TYPE SI, GOUGE AND CRACK ON BARRIER NET SUPPORT ANGLES AT STA 365 STR 7 AND 8 LT. REMOVED AND REPLACED BARRIER SUPPORT ANGLES AND CHANNEL IAW SRM 51-30-2, 51-10-2, 51-10-1.SDR UPS96220532Support · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR SUPPORT STA 294 TO 303 LBL 13 TO 15 WL 208 ON BOTTOM OF SUPPORT. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED AND REPLACED SUPPORT IAW SRM 51-30-02, 51-20-4, 53-10-1.SDR UPS96220531Link · corrodedINSPECTION TYPE SI, CORROSION ON EXPANSION LINK IN CENTER CHANNEL STA 740 TO 760 BL 0 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED AND REPLACED EXPANSION LINK IAW 51-10-2, 51-10-6, 51-30-2, 51-30-4 AND 51-30-8.SDR UPS96220530Track · corrodedINSPECTION TYPE SI, NR 4 SLAT TRACKS, BOTH HAVE CORROSION ON FWD ENDS AND BOTH SIDES. REMOVED AND REPLACED SLAT TRACKS IAW OHM 57-51-61.SDR UPS96220528Bullnose · corrodedINSPECTION TYPE SI, BULLNOSE CENTER HINGE LOWER ATTACH POINT ON NR 3 K-FLAP IS CORRODED UNDER BOLT HEAD. REMOVED AND REPLACED NR 3 K-FLAP IAW MM 27-81-01.SDR UPS96220526Keel Beam · crackedINSPECTION TYPE SI, APU SIDE WEBS ARE CRACKED AT BS 870, LBL 5.5 AND RBL 5.5 WL 156. CUTOUT DAMAGE AND REPAIRED KEEL BEAM IAW UPS IAW EO B727-5330-1995-B AND BOEING DRAWING 65-88832.SDR UPS96220524Channel · corrodedINSPECTION TYPE SI, CORROSION ON INTERCOSTAL STA 850 LBL 45 TO 65 WL 208. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-10-1.SDR UPS96220487Hinge Ftg · corrodedINSPECTION TYPE SI, L/W O/B AILERON O/B CENTER HINGE SUPPORT FITTING IS CORRODED. REMOVED CORRODED HINGE FITTING, DRILLED NEW FITTING AND INSTALLED IAW SRM 51-30-02.SDR UPS96220486Hinge Fitting · corrodedINSPECTION TYPE SI, R/W O/B AILERON TAB SIDE HINGE FITTINGS ARE CORRODED. FOUND HINGE FITTINGS TO BE OUT OF LIMITS PER SRM 57-40-00. REMOVED AND REPLACED R/W O/B AILERON TAB HINGE FITTINGS PER MM 27-10-41.SDR UPS96220485Floor Beam · corrodedINSPECTION TYPE SI, CORROSION IN NUTPLATE HOLES ON FLOOR BEAM BOTTOM SIDE OF UPPER FLANGE STA 600 WL 207.5 RBL 47 TO 63 AREAS MARKED. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-01, REPAIRED FLOOR BEAM AT BS 600 RBL 47 TO 63 PER UPS 727-53-1769.SDR UPS96220483Fitting · corrodedINSPECTION TYPE SI, R/W O/B AILERON O/B WING SIDE HINGE FITTING IS CORRODED. FOUND R/W O/B AILERON O/B WING SIDE HINGE FITTING OUT OF LIMITS PER SRM 57-40-00. REMOVED AND REPLACED R/W O/B AILERON O/B WING SIDE HINGE FITTING PER SRM 51-30-02.SDR DHL9670601CSeat Track · corrodedAT C-CHECK, FOUND SEAT TRACK CORRODED AT STA 700 TO 740 AT LBL 45. REMOVED AND REPLACED TRACK PER SRM 51-10-5.SDR UPS96220445Seat Track · corrodedINSPECTION TYPE SI, CORROSION ON SEAT TRACK AT BS 520 RBL 15 WL 150. REMOVED AND REPLACED SEAT TRACK FROM 480 TO 530 RBL 15 WL 15 IAW SRM 53-10-05.SDR UPS96220444Intercostal · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR SUPPORT INTERCOSTAL STA 313 TO 327 WL 208 RBL 47 AREA MARKED. FOUND SUPPORT OUT OF LIMITS. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-30-5 AND 51-30-2.SDR UPS96220480Floor Support · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR SUPPORT AT BS 480 WL 155 LBL 9. REMOVED DAMAGED SECTON OF FLOOR SUPPORT AND SPLICED A REPLACEMENT SECTION IN IAW SRM 53-10-5 AND 51-30-2.SDR UPS96220475Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR BEAM STA 344, WL 208 HAS NUMEROUS AREAS OF CORROSION FROM LBL 60 TO RBL 20. REMOVED AND REPLACED UPPER CHORD OF FLOOR BEAM IAW SRM 53-10-08.SDR UPS96220474Bulkhead Angle · corrodedINSPECTION TYPE SI, CORROSION ON BULKHEAD ANGLE AT BS 480, WL 155, LBL 12, RBL 12. REMOVED AND REPLACED ANGLE IAW 51-30-02, 51-10-05 AND MM 51-20-151.SDR UPS96220473Stringer · corrodedINSPECTION TYPE SI, FOUND CORROSION ON STRINGER 22 RT BETWEEN STA 351.2 AND STA 360. CORROSION REMOVAL WAS OUT OF LIMITS PER SRM 53-10-01. REMOVED DAMAGED SECTION OF STRINGER, LOCATED AND DRILLED STRINGER REPAIR PARTS, INSTALLED PER SRM 53-10-03, 51-30-02, 5SDR UPS96220471Stringer Tie · corrodedINSPECTION TYPE SI, FOUND CORROSION ON FRAME AT STA 360, WL 50, LBL 25 TO RBL 25 AND STRINGER TIE AT RT STR NR 22, STA 360. CORROSION REMOVAL WAS BEYOND LIMITS ON STRINGER TIE AT STR 22R. REPLACED STR TIE PER 53-10-02, 53-10-03, 51-10-06, MM 51-20-151.SDR RAAAB296028Light · failedMID CABIN SERVICE DOOR EMERGENCY EXIT LIGHT FAILED SERVICE CHECK. CHANGED LIGHT ASSEMBLY. (M)SDR UPS96220469Cargo Puck · corrodedINSPECTION TYPE SI, CORROSION ON CARGO PUCK STA 580, WL 208, LBL 40 AREA MARKED. REMOVED AND REPLACED CARGO PUCK IAW SRM 51-30-02 AND 51-10-01.SDR UPS96220468Angle · corrodedINSPECTION TYPE SI, CORROSION AT BS 870 VERTICAL SUPPPORT AND TIE ANGLE LBL 12 WL 199 LEFT MLG WHEEL WELL. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED AND REPLACED SUPPORT AND TIE ANGLE IAW SRM 53-30-02, 51-40-04, MM 51-20-31, 51-30-00.SDR UPS96220467Cargo Puck · corrodedINSPECTION TYPE SI, CORROSION ON CARGO PUCK STA 720, WL 208, LBL 57. REMOVED AND REPLACED CARGO TIE DOWN FITTING IAW SRM 51-30-02 AND 51-10-01.SDR UPS96220466Cargo Puck · corrodedINSPECTION TYPE SI, CORROSION ON CARGO PUCK STA 700, WL 208, LBL 57. REMOVED AND REPLACED CARGO TIE DOWN FITTING IAW SRM 51-30-02 AND 51-10-01.SDR UPS96220465Cargo Puck · corrodedINSPECTION TYPE SI, CORROSION ON CARGO PUCK STA 460, WL 208, LBL 40. REMOVED AND REPLACED CARGO TIE DOWN FITTING IAW SRM 51-30-02 AND 51-10-01.SDR UPS96220464Stiffener · corrodedINSPECTION TYPE SI, CORROSION ON HORIZONTAL STIFFENER AT BS 344, LBL 12 WL 183. REMOVED AND REPLACED STIFFENER IAW SRM 51-30-2, 51-10-5 AND 51-10-01.SDR UPS96220463Intercostal · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR SUPPORT STA 257 TO 277 LBL 13 TO 15 WL 208. FOUND CORROSION TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-20-04 AND 51-30-02.SDR UPS96220462Intercostal · corrodedINSPECTION TYPE SI, CORROSION ON FLOORBOARD SUPPORT INTERCOSTAL STA 327 TO 343, WL 208 LBL 30, AREAS MARKED. FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 51-10-6. REMOVED AND REPLACED SUPPORT IAW SRM 51-30-02.SDR UPS96220566Attach Fitting · corrosionINSPECTION TYPE-C, CORROSION FOUND ON LOWER SURFACE OF THE AFT UPPER FLANGE OF THE BS 870 FITTING AT FLOOR BEAM ATTACH. REPAIR IAW SRS EO 96-27-006.SDR UPS96220565Floor Beam · crackedINSPECTION TYPE-C, CRACK FOUND ON FLOOR BEAM UPPER FLANGE AT BS 870 AT ATTACH POINT TO BS 870 FITTING RT SIDE. REPAIRED IAW SRS EO 96-27-012.SDR UPS96220564Frame · crackedINSPECTION TYPE-C, CRACKS FOUND IN BS 940 FRAME. FRAME REPLACED PER UPS EO B727-5310-4501.SDR UPS96220563Skin · corrodedINSPECTION TYPE-C, CORROSON ON SKIN AT BUTT JOINT BS 441 54L TO 53R. REPAIRED PER APPENDIX 8.5 OF B727-5310-1371E.SDR UPS96220562Lower Beam · corrodedINSPECTION TYPE-C, CRACK IN LOWER BEAM OF MAIN CARGO DOOR AT BS 580. REPAIRED IAW SRS EO 96-27-007.SDR UPS96220561Latch Fittings · corrodedINSPECTION TYPE-C, MAIN CARGO DOOR LATCH FITTINGS PINS SEIZED. ALL LATCH FITTINGS REPLACED SRS EO 96-27-005.SDR UPS96220560Skin · crackedINSPECTION TYPE-C, CRACK FOUND IN SKIN BEHIND STR 18A AT RT BS 936. REPAIRED IAW UPS EO B727-5330-3815-A.
Back to Boeing 727-22C