SDR USAA001894Floorbeam · crackedCLT - FOUND FLOORBEAM CRACKED 1.5 INCH, RBL 24 LONGITUDINAL FLOORBEAM STATION 677, WL 206. INSTALLED DOUBLER AND U-CHANNEL PER EA 68275. (M)SDR USAA001893Skin · crackedCLT - FOUND SKIN CRACKED .5 INCH, STATION 322, FORWARD ENTRY DOOR SILL. EXTERIOR. INSTALLED REPAIR STRAP AND DOUBLER PER EA 68364. (M)SDR USAA001892Frame · crackedCRACK STA 490, STR 23R. SPLICED IN FRAME SECTION PER SRM 51-40-3 FIG 1SDR USAA001891Frame · crackedCRACK STA 597, R/W LWR SIDE OF FRAME. REPLACED WEB/FRAME PER SRM 51-10-01SDR USAA001890Floorbeam · corrodedCORROSION LEVEL 1 C 53-107-02 FLOORBEAM INTERCOASTAL STRAP STA 1016, LBL 17.5INSTALLED FLOORBEAM REPAIR ANGLE PER SRM 51-10-1SDR USAA001889Intercostal · corrodedCORROSION LEVEL 1 C 53-107-02 FLOORBEAM INTERCOASTAL STRAP STA 1016, RBL 2.5.INSTALLED DOUBLER PER SRM 531009 & 536002SDR USAA001888Floorbeam · corrodedFLOORBEAM CORRODED. INSTALLED DOUBLER PER SRM 53-10-09 & TR 53-60-02.SDR USAASB00307Pump · failedBOS - FLT 2822 - EN ROUTE FROM MCO-BOS, THE CAPT SENT ACARS MESSAGE THAT THE STANDBY HYDRAULIC LOW QTY LIGHT WAS ILLUMINATED. NO OTHER LIGHTS WERE ON AT THIS TIME AND A DECISION WAS MADE TO PROCEED ON. ON INITIAL APPROACH INTO BOS, THE A-HYDRAULIC SYSTEM DROSDR USAA001877Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES AND 1 FT BY 2 INCHES, STATION 1006 TO 1016, LBL 5.5 TO 9. REMOVED AND REPLACED PER SRM 51-30-00. (M)SDR USAA001876Stringer · crackedCLT - FOUND SHELF 18A CRACKED .5 INCH, LEFT MOST INBOARD HOLE. INSTALLED NEW PART PER SRM 51-30-1. (M)SDR USAA001859Frame · crackedCLT - FOUND CHORD CRACKED 2 INCH, BS 178, WL 195, LBL 24. INSTALLED NEW CHORD ANGLE. (M)SDR USAA001858Web · crackedCLT - FOUND WEB CRACKED, BS 178, RBL 5, WL 198. INSTALLED DOUBLER PER EA 68266. (M)SDR USAA001857Web · crackedCLT - FOUND WEB CRACKED .5 INCH IN TWO PLACES, BS 178, LBL 5 AND 6 UPPER RADAR MOUNT BRACKET. INSTALLED DOUBLER PER EA 68266. (M)SDR USAA001856Frame · crackedCLT - FOUND SIDE CHORD CRACKED 1 INCH, BS 178, WL 207, LBL 26. INSTALLED NEW CHORD ANGLE PER EA 68295. (M)SDR USAA001855Web · crackedCLT - FOUND WEB CRACKED 1 INCH, BS 178, WL 207, LBL 27. INSTALLED NEW CHORD ANGLE PER EA 68295. (M)SDR USAA001854Web · crackedCLT - FOUND WEB CRACKED .250 INCH, BS 178, LBL .05, WL 197-201. INSTALLED DOUBLER PER EA 68266. (M)SDR USAA001853Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH IN SIX AREAS, UPPER T-CAP FLOORBEAM STATION 1006, LBL 9, 11, 15, 28.5. INSTALLED NEW T-CAP SECTION PER SRM 53-10-9 FIG 2. (M)SDR USAA001871Web · crackedCLT - FOUND WEB CRACKED .75 INCH, BS 178, WL 213, LBL 5. INSTALLED DOUBLER PER SRM 53-10-11 AND EA 68167. (M)SDR USAA001870Web · crackedCLT - FOUND WEB CRACKED 2 INCHES, BS 178 LBL 5, WL 201/197. INSTALLED DOUBLER PER SRM 53-10-11. (M)SDR USAA001869Web · crackedCLT - FOUND WEB CRACKED .5 INCH, BS 178, WL 190, 194, 196 AT RBL 5. INSTALLED DOUBLER PER SRM 53-10-11 AND EA 68167. (M)SDR USAA001868Web · crackedCLT - FOUND WEB CRACKED .5 INCH, BS 178, LBL 5, WL 190, 193, 194. INSTALLED DOUBLER PER EA 68167 AND SRM 53-10-11. (M)SDR USAA001867Stringer · corrodedCLT - FOUND STRINGER CORRODED 6 INCHES, STRINGER 24R STATION 360. SPLICED REPAIR PER TR 53-10-13. (M)SDR USAA001866Frame · crackedCLT - FOUND SIDE CHORD CRACKED 3 INCHES, BS 178 LBL 24, WL 195. INSTALLED NEW CHORD ANGLE PER SRM 53-30-10 AND EA 68321. (M)SDR USAA001865Fitting · crackedCLT - FOUND STOP PAD SUPPORT FITTING CRACKED .25 INCH, STATION 332.1 AFT SIDE STRINGER 8R. SPLICED REPAIR PER SRM 53-10-5. (M)SDR USAA001864Angle · crackedCLT - FOUND VERTICAL ANGLE CRACKED .750 INCH, 663 BULKHEAD, RBL 45 INCHES AND 10 INCHES DOWN FROM CEILING. FABRICATED NEW STIFFENER AND INSTALLED PER SRM 51-10-1 AND DWG 6545409. (M)SDR USAA001862Floorbeam · crackedCLT - FOUND FLOORBEAM CRACKED 2.5 INCH, STATION 679, LBL 25 CABIN FLOORBEAM. FABRICATED NEW FLOORBEAM INSTALLED PER DWG NR 65C34537. (M)SDR USAA001861Angle · crackedCLT - FOUND ANGLE CRACKED .25 INCH, STATION 290 R/T STOP SUPPORT WEB STRINGER 12R. INSTALLED NEW ANGLE PER SRM 51-10-02. (M)SDR USAA001842Web · crackedCLT - FOUND WEB CRACKED 1 INCH, BS 676, RBL 25. INSTALLED DOUBLER AND V CHANNEL PER EO 5791G632. (M)SDR USAA001841Floorbeam · crackedCLT - FOUND FLOORBEAM CRACKED .250 INCH, BS 668 - BS 680, LBL 23.5. REMOVED AND REPLACED BEAM PER DWG 65-45410. (M)SDR USAA001840Stiffener · crackedCLT - FOUND VERTICAL CHORD CRACKED .25 INCH, BS 178, AFT SIDE LBL 5-7, WL 184. FOUND DOUBLER STRAP/REPAIR ANGLES PER SRM 53-10-11. (M)SDR USAA001839Stiffener · crackedCLT - FOUND VERTICAL CHORD (STIFFENER) CRACKED .25 INCH, BS 178, AFT SIDE RBL 5-7, WL 184. FOUND DOUBLER STRAP/REPAIR ANGLES PER SRM 53-10-11. (M)SDR USAA001851Doubler · crackedCLT - FOUND DOUBLERS CRACKED 1 INCH, FORWARD UPPER HINGE FORWARD ENTRANCE DOOR. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 51-10-2. (M)SDR USAA001850Frame · crackedCLT - FOUND FRAME CRACKED 3 INCHES, FRAME 360 R/T WINDOW BELT. FABRICATED REPAIR DOUBLER AND FILLER PER SRM 53-10-4. (M)SDR USAA001849Frame · crackedCLT - FOUND FRAME CRACKED .375 INCH, STATION 312, BETWEEN STRINGER 5 AND STRINGER 6L. REPAIRED PER SRM 51-40-3 AND 20-30-06. (M)SDR USAA001848Angle · crackedCLT - FOUND ANGLE CRACKED .25 INCH, STATION 290, R/T STOP SUPPORT WEB STRINGER 14R. REMOVED AND INSTALLED FABRICATED NEW ANGLE PER SRM 51-10-1. (M)SDR USAA001847Bulkhead · crackedCLT - FOUND BULKHEAD WEB CRACKED .25INCH, BS 178, RBL 5.5, WL 198. INSTALLED DOUBLER PER SRM 53-10-11/EA 68167. (M)SDR USAA001846Bulkhead · crackedCLT - FOUND BULKHEAD WEB CRACKED .5 INCH, BS 178, RBL 5.5, WL 201. INSTALLED DOUBLER PER SRM 53-10-11/ EA 68167. (M)SDR USAA001845Frame · crackedCLT - FOUND CHORD ANGLE CRACKED 3 INCHES, STATION 178 WL 195-LBL 26 BULKHEAD SIDE. SPLICED NEW CHORD ANGLE PER SRM 53-10-11/EA 68167. (M)SDR USAA001844Bulkhead · crackedCLT - FOUND SKIN CRACKED 2 INCHES, FS 178, LBL 5.7, WL 212. INSTALLED DOUBLER PER SRM 53-10-11/EA 68167. (M)SDR USAA001843Bulkhead · crackedCLT - FOUND SKIN CRACKED 2 INCHES, FS 178, RBL 5.7, WL 212. INSTALLED DOUBLER PER SRM 53-10-11/EA 68167. (M)SDR USAA001835Tie Clip · crackedCLT - FOUND STRINGER TIE CLIP CRACKED .25 INCH, STATION 578 STRINGER 5L. REPLACED TIE CLIP PER EO 5393G227 REV A. (M)SDR USAASB00305Charger · failedTPA - MAINTENANCE FOUND TWO FORWARD CABIN/ENTRY DOOR SECTIONS OF EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK (P/N 9008-3-5A) AND CHARGER ASSEMBLY IN THE OVERHEAD BIN NEAR SEAT ROW 1 AND THE POWER SUPPLY (P/N 60-1321-1)SDR USAA001833Web · crackedCLT - FOUND WEB CRACKED .250 INCH, BS 706-710, LBL 24. INSTALLED NEW WEB PER EA 68267. (M)SDR USAA001832Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 3 INCHES, LOWER SURFACE CREASEBEAM WEB AFT SERVICE DOOR. INSTALLED DOUBLER AND REPAIR ANGLE PER SRM 51-10-1. CORROSION LEVEL 1 C53-107-02. (M)SDR USAA001831Skin · crackedCLT - FOUND SKIN CRACKED 3 INCHES, AFT ENTRY DOOR UPPER AFT RADIUS CUTOUT. INSTALLED DOUBLER PER EA 68265. (M)SDR USAA001830Skin · crackedCLT - FOUND SLAT SKIN CRACKED 6 INCHES, NR 5 SLAT LOWER LEADING EDGE SKIN INBOARD TRACK. REPAIRED DOUBLER PER EA 68377. (M)SDR USAA001829Floor Support · crackedCLT - FOUND FLOOR STRUCTURE CRACKED 2 INCHES, BS 178 RBL 28, WL 207. FABRICATED AND INSTALLED PART PER EO 5300V152. (M)SDR USAA001826Stringer · corrodedCLT - FOUND STRINGER CORRODED 1 INCH BY 1 INCH AREA, BS 948 STRINGER 27L. CORROSION LEVEL 1. INSTALLED NEW SECTION PER SRM 53-10-3. (M)SDR USAA001825Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH IN FOUR PLACES, STATION 947.5 RBL 4, 5, 10.5 AND LBL 5. CORROSION LEVEL 1. SPLICED T-CAP PER SRM 53-10-2. (M)SDR USAA001824Angle · corrodedCLT - FOUND TRANSITION ANGLE CORRODED 32 INCHES BY 1 INCH, STATION 344 TO 312. INSTALLED NEW Z-ANGLE PER SRM 51-10-2 AND 51-30-3. (M)
Back to Boeing 737-201