Boeing 737-2Y5
Service difficulty reports · 334
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7372Y5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7372Y5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA00201Intercostal · corrodedDEN - DURING C-3 CHECK, INSPECTION REPORTED CORROSION ON INTERCOSTAL AT STATION 312, BETWEEN LBL 40 AND RBL 40. MAINTENANCE REMOVED CORROSION FROM UPPER CHORD, FABRICATED AND INSTALLED REPLACEMENT UPPER CHORD PER SRM 51-10-1, FIG 1 AND SRM 53-10-9 FIG 5. (M)SDR F3LA00200Floorbeam · corrodedDEN - DURING C-3 CHECK, INSPECTION REPORTED CORROSION IN AND AROUND FLOORBEAM CLIP NUT HOLES, STATION 294, BL 8R TO BL 44R. MAINTENANCE REMOVED CORROSION PER MM 51-31-31, FABRICATED REPLACEMENT PARTS AND INSTALLED PER 51-10-2, 53-10-2, AND 53-10-9, FIG 5. (MSDR F3LA00214Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION, FOUND FLOORBEAM UPPER CHORD AT STATION 277 CORRODED FROM LBL 17 TO LBL 49. MAINTENANCE FABRICATED REPLACEMENT UPPER CHORD PER SRM 53-10-02 AND INSTALLED PER SRM 51-30-0. (M)SDR F3LA00199Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION REPORTED CORROSION IN AND AROUND FLOORBEAM CLIP NUT HOLES, STATION 294, BL 8R TO BL 44R. MAINTENANCE REMOVED CORROSION PER MM 51-31-31. FABRICATED REPLACEMENT PARTS AND INSTALLED PER 51-10-2, 53-10-2, AND 53-10-9 FIG 5. (M)SDR F3LA00198Plate · corrodedDEN - DURING C-3 CHECK INSPECTION REPORTED PITTING AND CORROSION ON L-2 DOOR UPPER AND LOWER GUIDE PLATES. MAINTENANCE REPLACED UPPER AND LOWER GUIDE PLATES (P/N 69391832, 69446521) WITH BEARINGS PER MM 53-41-0. (M)SDR F3LA00196Stringer · crackedDEN - DURING C-3 CHECK INSPECTION REPORTED STRINGER SUPPORT AT STATION 272B, STRINGER 4R, CRACKED. MAINTENANCE REMOVED CRACKED BRACKET. FABRICATED AND INSTALLED REPLACEMENT BRACKET PER SRM 51-10-01. (M)SDR F3LA00195Floorbeam · corrodedDEN - DURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE, STATION 294 BL 0, FORWARD CABIN FLOORBEAM CAP. MAINTENANCE REPLACED FLOORBEAM PER SRM 51-21-31. (M)SDR F3LA00194Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION REPORTED CORROSION ON FLOORBEAM AT STATION 294.5 UNDER FORWARD GALLEY, INBOARD OF R-1 DOOR. MAINTENANCE REPLACED FLOORBEAM PER SRM 51-21-31. (M)SDR F3LA00207Pan · corrodedDEN - DURING C-2 CHECK INSPECTION, FORWARD LAVATORY OUTBOARD FLOOR PAN ATTACH ANGLE CORRODED IN 2 PLACES. MAINTENANCE FABRICATED, DRILLED AND INSTALLED NEW FLOOR PAN ATTACH ANGLE. (M)SDR F3LA00206Stringer Clip · crackedDEN - DURING C-2 CHECK INSPECTION, REPORTED STRINGER TIE CLIP CRACKED AT STATION 639, STRINGER 8L. MAINTENANCE FABRICATED AND DRILLED REPLACEMENT CLIP AND INSTALLED CLIP PER SRM 51-20-01 AND 51-30-02. (M)SDR F3LA00222Flange · corrodedDEN - DURING C-3 CHECK INSPECTION, FOUND CORROSION ON DUMP VALVE HOUSING MOUNT FLANGE. MAINTENANCE FABRICATED REPLACEMENT LAVATORY PAN DOUBLERS, HEAT TREATED, TREATED, PRIMED AND INSTALLED PER SRM 51-10-03 AND 51-30-0. (M)SDR F3LA00184Gate · brokenDEN - FOUND DURING C-2 CHECK INSPECTION, REPORTED L1 DOOR LOWER GATE BROKEN AT PUSH-PULL ATTACH CENTER, EAR BROKEN OFF. MAINTENANCE REMOVED L1 DOOR LOWER GATE ASSEMBLY AND INSTALLED SERVICEABLE LOWER GATE ASSEMBLY PER SRM 51-30-02 AND 51-30-05. (M)SDR F3LA00187Floorbeam · corrodedDEN - FOUND DURING C-3 CHECK INSPECTION REPORTED TOP CHORD OF FLOORBEAM CORRODED AT STATION 328 BETWEEN LBL 40 AND RBL 40. MAINTENANCE REMOVED DAMAGED SECTION OF TOP CHORD. FABRICATED AND INSTALLED REPLACEMENT SECTION PER SRM 51-30-00. (M)SDR F3LA00186Stringer Clip · crackedDEN - DURING C-3 CHECK INSPECTION, REPORTED STRINGER FRAME TIE CLIP CRACKED .25 INCH, STRINGER 6R, STATION 887. MAINTENANCE REMOVED CRACKED TIE CLIP. FABRICATED AND INSTALLED NEW TIE CLIP PER SRM 51-30-02 AND 53-10-02. (M)SDR F3LA00185Stringer Clip · crackedDEN - DURING C-3 CHECK INSPECTION REPORTED STRINGER FRAME TIE CLIP CRACKED .25 INCH, STRINGER 6R, STATION 727B. MAINTENANCE REMOVED CRACKED TIE CLIP. FABRICATED AND INSTALLED NEW TIE CLIP PER SRM 51-30-02 AND 53-10-02. (M)SDR F3LA00183Stringer Clip · crackedDEN - DURING C-3 CHECK INSPECTION, REPORTED STRINGER FRAME TIE CLIP CRACKED .75 INCH, STRINGER 7L, STATION 747L. MAINTENANCE REMOVED CRACKED TIE CLIP. FABRICATED AND INSTALLED NEW TIE CLIP PER SRM 51-30-02 AND 53-10-02. (M)SDR F3LA00223Structure · wornDEN - DURING C-3 CHECK, FOUND NR 2 ENGINE INLET TRAILING EDGE MATING SURFACE FOR ENGINE COWL AT 6:00 POSITION WORN VERY THIN. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED TWO REPAIR ANGLES AND FILLERS PER SRM 54-10-03 AND TREATED AND PRIMED PER SRM 51-10-02. SDR F3LA00221Rib · damagedDURING C-3 CHECK INSPECTION, FOUND 6TH RIB FROM REAR OF NR 2 ENGINE RT OUTBOARD COWL DAMAGED THROUGHOUT ENTIRE LENGTH. MAINTENANCE INSTALLED NEW RIB PER SRM 51-30-0. (M)SDR F3LA00213Floor Support · corrodedDEN - DURING C-3 CHECK INSPECTION, REPORTED FLOOR SUPPORT SHIM FROM STATION 277 TO STATION 294 CORRODED. MAINTENANCE FABRICATED NEW SHIM PER EA 53-737-085, TREATED AND PRIMED PER SRM 51-10-02 AND INSTALLED SHIM. (M)SDR F3LA00181Floor Panel · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION ON TOP OF LONGITUDINAL FLOOR PANEL INTERCOSTAL FROM STATION 292.5 TO STATION 312, LBL 10. MAINTENANCE FABRICATED NEW FLOOR SUPPORT AND COVER CAP PER 51-30-02 AND INSTALLED PER SRM 51-10-02 AND 51-30-02. (SDR F3LA00182Stringer · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION BEYOND SRM LIMITS ON STRINGER 25L AT STATION 1006. MAINTENANCE REMOVED DAMAGED AREA AND FABRICATED AND INSTALLED NEW STRINGER SPLICE AND STRINGER PER SRM 51-00-04, 51-10-06, 51-30-02 AND 53-10-03. (M)SDR F3LA00177Floor Support · crackedDEN - DURING C-2 CHECK INSPECTION, REPORTED FLOOR ATTACH ANGLE BRACKET CRACKED AT STATION 329, RBL 35. MAINTENANCE REMOVED CRACKED ANGLE BRACKET PER SRM 51-30-02. FABRICATED NEW BRACKET PER SRM 51-30-06 AND 51-10-02 AND INSTALLED IT PER SRM 51-10-02. (M)SDR F3LA00178Floor Support · crackedDEN - DURING C-2 CHECK INSPECTION, REPORTED FLOOR ATTACH ANGLE BRACKET CRACKED AT STATION 312, LBL 10. MAINTENANCE REMOVED CRACKED ANGLE BRACKET PER SRM 51-30-02. FABRICATED NEW BRACKET PER SRM 51-30-06 AND INSTALLED PER SRM 51-10-02. (M)SDR F3LA00179Floor Support · crackedDEN - DURING C-2 CHECK INSPECTION, REPORTED FLOOR ATTACH ANGLE BRACKET CRACKED AT STATION 329, LBL 40. MAINTENANCE REMOVED CRACKED ANGLE BRACKET, FABRICATED NEW ANGLE PER SRM 51-30-06 AND 51-10-02 AND INSTALLED PER SRM 51-10-02. (M)SDR F3LA00220Fitting · corrodedDEN - DURING C-3 CHECK INSPECTION, REPORTED INTERGRANULAR CORROSION ON ATTACH FITTING ON RIGHT MLG SUPPORT BEAM AT NR 5 GROUND SPOILER INBOARD ACTUATOR BRACKET. MAINTENANCE REPLACED ATTACH FITTING PER MM 27-62-12 AND SRM 51-10-02. (M)SDR F3LA00171Doubler · damagedDEN - DURING C-2 CHECK INSPECTION, REPORTED RIVETS ON EXISTING SHEET METAL PATCH BETWEEN STATION 867 AND STATION 887, STRINGER 21R TO 22R, FAULTY. MAINTENANCE REMOVED EXISTING PATCH AND INSTALLED FLUSH PATCH PER SRM 53-30-03, FIGURE 7. (M)SDR F3LA00168Floorbeam · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION ON TOP OF FLOORBEAM AT STATION 329, LBL 30. MAINTENANCE REMOVED CORROSION BUT FOUND IT TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED NEW REPAIR ANGLES PER SRM 51-SDR F3LA00170Doubler · damagedDEN - DURING C-2 CHECK INSPECTION, REPORTED RIVETS ON EXISTING SCAB PATCH BETWEEN STATION 867 AND STATION 887, STRINGER 24R TO 25R, FAULTY. MAINTENANCE REMOVED EXISTING PATCH AND INSTALLED FLUSH PATCH PER SRM 53-30-03, FIGURE 7. (M)SDR F3LA00173Floorbeam · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION ON TOP OF FLOORBEAM AT STATION 295.0, RBL 10. MAINTENANCE REPLACED FLOORBEAM PER FRONTIER ENGINEERING AUTHORIZATION 53-737-082 AND SRM 51-30-02. (M)SDR F3LA00174Strap · damagedDEN - DURING C-2 CHECK INSPECTION, REPORTED SMALL HOLE IN RADIUS OF TEAR STRAP, STATION 277, STRINGER 21R. MAINTENANCE INSTALLED DOUBLER ON TEAR STRAP PER SRM 53-30-02. (M)SDR F3LA00180Floor Support · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION ON TOP OF LONGITUDINAL FLOOR PANEL SUPPORT INTERCOSTAL AT STATION 295 RBL 10. MAINTENANCE REPLACED DAMAGED PART PER FRONTIER AIRLINES ENGINEERING AUTHORIZATION 53-737-082 AND SRM 51-30-02. (M)SDR F3LA00167Frame · crackedDEN - DURING C-2 CHECK INSPECTION, REPORTED BELT FRAME CRACKED AT STATINO 380 AND AT TRANSITION PANEL ABOVE STRINGER 26R. MAINTENANCE REMOVED DAMAGED FLANGE, FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 51-40-03, FIGURE 1. (M)SDR TSAA0053198Skin · dentedREPAIRED A DENT AT LEFT FUSELAGE BS 360-380 STRINGER 17L, AFT OF FORWARD ENTRY DOOR. CUT OUT DAMAGED AREA PERFORMED HFEC INSPECTION. FABRICATED AND INSTALLED DOUBLER PER SRM 53-30-3. AIRCRAFT RETURNED TO SERVICE. (M)SDR TSAA0033182Battery · inoperativeREPLACED NR 4 POSITION FLOOR EMERGENCY LIGHT BATTERY PACK DUE TO INOPERATIVE. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR F3LA000208Floor Support · corrodedDEN - DURING C-2 CHECK INSPECTION, FOUND FLOOR SUPPORT AT STATION 927 TO 947.5, LBL 44 CORRODED IN SEVERAL PLACES. MAINTENANCE FABRICATED, HEAT TREATED, PRIMED AND INSTALLED NEW SUPPORT PER EO 51-00-737-001, SRM 51-10-01, SRM 51-20-01, SRM 51-30-02 AND 53-10-SDR F3LA00172Floor Support · corrodedDURING C-2 CHECK, INSPECTION REPORTED CORROSION ON AFT FLOOR DIAGONAL SUPPORT, STATION 996 TO STATION 1012, LBL 4 TO 20. MAINTENANCE REPLACED EXISTING STRAP OVER FLOOR SUPPORT WITH NEW STRAP PER SRM 51-30-02. (M)SDR F3LA00169Door Frame · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED CORROSION ALONG RIGHT AFT DOOR CHORD, STRINGER 17R FROM STATION 927 TO STATION 1006. MAINTENANCE REMOVED CORROSION, TREATED, PRIMED AND PAINTED PER SRM 51-10-6 AND 53-10-2. (M)SDR F3LA00166Toggle · looseDEN - DURNG C-2 CHECK INSPECTION, REPORTED EXCESSIVE OF OUTBOARD TOGGLE ASSY ON RT INBOARD FORE FLAP. RETORQUED AND SAFETIED RT INBOARD FORE FLAP OUTBOARD TOGGLE BRACKETS PER MM 27-50-01. (M)SDR F3LA00176Stringer · corrodedDEN - DURING C-2 CHECK INSPECTION, REPORTED STRINGER 23L CORRODED BETWEEN STATION 500 AND 500A ON TOP AND BOTTOM AS WELL AS AROUND CENTER NUTPLATE. MAINTENANCE REMOVED DAMAGED SECTION. FABRICATED STRINGER REPAIR PER SRM 53-10-03 AND INSTALLED PER SRM 51-30-0SDR TSAA0073139Fcu · failedFLT 71 - OGG-HNL - THE NR 1 ENGINE RPM GAGE IMMEDIATELY DECREASED TO ZERO THE MOMENT THE AIRCRAFT LIFTED OFF THE RUNWAY. DID NOT ATTEMPT A RESTART, ACCOMPLISHED NORMAL SINGLE ENGINE LANDING WITH NO FURTHER PROBLEMS NOTED. REMOVED AND REPLACED NR 1 ENGINE FUESDR 20000516AP006Power Supply · inoperativeDEN - DURING SERVICE CHECK, MAINTENANCE REPORTED AFT DOOR EMERGENCY EXIT LIGHTS WOULD NOT TEST OR LIGHT. MAINTENANCE REPLACED BATTERY PACK AND POWER SUPPLY. REF F3LA00032. (M)SDR F3LA00032Battery Pack · inoperativeDEN - DURING SERVICE CHECK, MAINTENANCE REPORTED AFT DOOR EMERGENCY EXIT LIGHTS WOULD NOT TEST OF LIGHT. MAINTENANCE REPLACED BATTERY PACK AND POWER SUPPLY. (M)SDR TSAA9933479Battery · dischargedREPLACED NR 3, 4, 5, AND 6 POSITION FLOOR EMERGENCY LIGHT BATTERY PACK DUE TO INOPERATIVE. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99ZZZM807Sensor · intermittentFLT 101 - OGG-HNL - LEFT MAIN GEAR RED UNSAFE GEAR LIGHT COMES ON INTERMITTENTLY DURING FLIGHT. REMOVED AND REPLACED UPLOCK SENSOR LEFT GEAR PER MM 32-61-21 AND ALSO CHECKED UPLOCK MECHANISM PER MM 32-32-31. ALL OK, OPS OK ON GEAR SWING. AIRCRAFT RETURNED TSDR F3LA99120Light · inoperativeDEN - DURING SERVICE CHECK, MAINTENANCE REPORTED FORWARD ENTRY DOOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED FORWARD ENTRY DOOR EMERGENCY LIGHT ASSEMBLY. (M)SDR TSAA9933408Battery Pack · dischargedREPLACED NR 3 EMERGENCY FLOOR BATTERY PACK DUE TO LOW VOLTAGE. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR TSAA9933368Battery Pack · dischargedREPLACED NR 5 EMERGENCY FLOOR BATTERY PACK DUE TO INOPERATIVE. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR TSAA9933362Battery Pack · dischargedREPLACED NR 4 EMERGENCY FLOOR BATTERY PACK DUE TO LOW VOLTAGE. OPS CHECK OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR TSAA9921300Relief Valve · failedHNL/ITO - FLT 248 - PRESSURIZATION FAILURE AT FL 230. LOST AUTO, STANDBY, AND A/C MANUAL SHOWED VALVE CLOSED, BUT DIDN'T CONTROL CABIN. LATER, MANUAL AND STANDBY WORKED. DIVERTED TO OGG AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED CABIN PRESSURE CONTRSDR TSAA9921292Controller · failedHNL/ITO - FLT 248 - PRESSURIZATION FAILURE AT FL 230. LOST AUTO, STANDBY, AND A/C MANUAL SHOWED VALVE CLOSED BUT DID NOT CONTROL CABIN. LATER, MANUAL AND STANDBY WORKED. DIVERTED TO OGG AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED CABIN PRESSURE CONTR
Back to Boeing 737-2Y5