Boeing 737-3S3

Service difficulty reports · 1,209

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7373S3'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AWXA9500724Skin · crackedDURING SCHEDULED C11 INSPECTION, FOUND FORWARD GALLEY DOOR LOWER HINGE CUTOUT CRACKED. FABRICATED DOUBLER AND REPAIRED PER EO 52-00-02, FIGURE 6. (M)Oct 25, 1995 · N316AW · Boeing 7373S3 · Galley DoorsSDR AWXA9500722Skin · crackedPHX - DURING SCHEDULED C11 INSPECTION, FOUND CRACK IN FORWARD GALLEY DOOR UPPER HINGE CUT OUT. FABRICATED REPAIR PER EO 52-00-02, FIGURE 6. (M)Oct 25, 1995 · N316AW · Boeing 7373S3 · Galley DoorsSDR AWXA9500721Skin · crackedPHX - DURING SCHEDULED C11 INSPECTION, FOUND CRACK IN FORWARD GALLEY DOOR LOWER HINGE CUT OUT. FABRICATED DOUBLER REPAIR PER EO 52-00-02, FIGURE 6 PART 2. (M)Oct 25, 1995 · N316AW · Boeing 7373S3 · Galley DoorsSDR AWXA9500723Battery Pack · dischargedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND R2 DOOR AND CENTER GALLEY EMERGENCY EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, OPS CHECK GOOD. (M)Oct 23, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500713Hose · failedPHX - FLT 460 - DURING FINAL APPROACH TO PHX, THE B-SYSTEM HYDRAULIC QUANTITY STARTED DECREASING. B-SYSTEM WAS SHUT DOWN AND AIRCRAFT CONTINUED TO PHX, LANDING WITHOUT INCIDENT. MAINTENANCE REPLACED HYDRAULIC PRESSURE LINE FROM PUMP TO HYDRALIC PRESSURE MODUOct 18, 1995 · N313AW · Boeing 7373S3 · Hydraulic System, MainSDR AWXA9500684Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 THROUGH ROW 21. REPAIRED BROKEN WIRE, OPS CHECK GOOD. (M)Oct 4, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500621Floor Beam · corrodedPHX - DURING SCHEDULED C9 INSPECTION, FOUND FLOOR BEAM UPPER SURFACE CORRODED BEYOND LIMITS AT FASTENER HOLES, STATION 957 LBL 29. INSTALLED ANGLE REPAIR PER SRM 53-30-51. (M)Sep 11, 1995 · N314AW · Boeing 7373S3 · Fuselage Main, Floor BeamSDR AWXA9500620Chord · corrodedPHX - DURING SCHEDULED C9 INSPECTION, FOUND R2 DOOR CHORD AT STATION 947 TO STATION 996 CORRODED BEYOND LIMITS IN SEVERAL AREAS. REPLACED CHORD PER SRM 51-40-02. (M)Sep 11, 1995 · N314AW · Boeing 7373S3 · Fuselage Miscellaneous StructureSDR AWXA9500619Chord · corrodedPHX - DURING SCHEDULED C9 INSPECTION, FOUND L2 DOOR CHORD AT STATION 947 TO STATION 996 CORRODED BEYOND LIMITS IN SEVERAL AREAS. REPLACED CHORD PER SRM 51-40-02. (M)Sep 11, 1995 · N314AW · Boeing 7373S3 · Fuselage Miscellaneous StructureSDR AWXA9500618Floor Beam · gougedPHX - DURING SCHEDULED C9 INSPECTION, FOUND UPPER SURFACE OF CABIN FLOOR BEAM AT STATION 986 LBL 16 TO RBL 4 GOUGED OUT OF LIMITS. INSTALLED T-CAP REPAIR PER AWA ER 3-53-16-28. (M)Sep 11, 1995 · N314AW · Boeing 7373S3 · Fuselage Main, Floor BeamSDR AWXA9500598Skin · damagedPHX - DURING SCHEDULED C9 INSPECTION, FOUND LIGHTNING STRIKE DAMAGE TO SKIN THAT EXCEEDED SRM LIMITS AT STATION 364 STRINGER 6L. CLEANED AREA AND REPAIRED PER SRM 53-00-01, FIGURE 201. (M)Sep 4, 1995 · N313AW · Boeing 7373S3 · Fuselage Main, Plate/SkinSDR AWXA9500573Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 THROUGH ROW 21. RESECURED LOOSE WIRE AT ROW 21, OPS CHECK GOOD. (M)Aug 21, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500557Eel Wiring · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 14 THROUGH ROW 20. RECONNECTED WIRING IN TWO PLACES. OPS CHECK GOOD. (M)Aug 17, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500551Eel Pins · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE IN AFT SECTION OF AIRCRAFT. RECONNECTED PINS OF LIGHT ASSEMBLY AT ROW 20, OPS CHECK GOOD. (M)Aug 15, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500518Eel Wiring · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 THROUGH 21. RESECURED WIRING AT ROWS 17 AND 19. SYSTEM OPS CHECK GOOD. (M)Aug 8, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500495Eel Assy · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 16 THROUGH ROW 20. REMOVED AND REPLACED LIGHT ASSEMBLY AT ROW 16. OPS CHECK GOOD. (M)Aug 5, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500491Eel Assy · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE IN AFT OF AIRCRAFT. REPLACED LIGHT ASSEMBLY, OPS CHECK GOOD. (M)Aug 2, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500475Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 15 THROUGH ROW 21 EMERGENCY EXIT LIGHTS INOPERATIVE. REINSTALLED LOOSE WIRES, OPS CHECK GOOD. (M)Jul 28, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500463Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 12 THROUGH 23. RECONNECTED WIRING, OPS CHECK GOOD. (W)Jul 23, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500457Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 15 THROUGH 21. RESECURED LOOSE WIRING, OPS CHECK GOOD. (W)Jul 18, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500456Eel Fuse · failedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 THROUGH ROW 22. REPLACED FUSE IN AFT RT BATTERY PACK ASSEMBLY. OPS CHECK GOOD. (W)Jul 18, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500441Egt · highCMH - FLT 843 - THE NR 2 ENGINE HIGH EGT OCCURRED DURING TAKEOFF AND CLIMB, TEMP REACHED 936 DEGREES FOR 11 SECONDS. CREW RETURNED AC TO CMH AND LANDED UNEVENTFULLY. MX PERFORMED ENGINE PERFORMANCE GROUND RUN AND AVIONICS PERFORMED TEST OF EGT HARNESS, NO FAJul 15, 1995 · N313AW · Boeing 7373S3 · Engine EGT/TIT Indicating SystemSDR AWXA9500423Eel Assembly · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 11 THROUGH 15. RECONNECTED LIGHT ASSEMBLY, OPS CHECK GOOD. (X)Jul 3, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500422Eel Connector · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 17 THROUGH 21. REPAIRED LOOSE CONNECTION, OPS CHECK GOOD. (X)Jun 30, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500406Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PATH EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 7 THROUGH ROW 13. REPAIRED WIRE AT ROW 7, OPS CHECK GOOD. (X)Jun 30, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500405Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 THROUGH ROW 21. REPAIRED BROKEN WIRE AT ROW 20, OPS CHECK GOOD. (X)Jun 29, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500402Eel Wiring · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE ROW 18 THROUGH ROW 23. REPAIRED WIRING, OPS CHECK GOOD. (X)Jun 26, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500396Eel Assy · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS ROW 7 THROUGH ROW 9 INOPERATIVE. RECONNECTED LIGHTS, OPS CHECK GOOD. (M)Jun 22, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500386Connector · dirtyABQ-PHX - FLT 475 - CREW REPORTED THE EQUIPMENT COOLING WAS INOPERATIVE AND ELECTED TO RETURN TO ABQ. CONTRACT MAINTENANCE FOUND EQUIPMENT COOLING NORMAL, THE SUPPLY FAN FAILED. AN UNMANNED STATION RELEASE WAS GIVEN AND THE AIRCRAFT RETURNED TO PHX. UPON ARJun 19, 1995 · N313AW · Boeing 7373S3 · Air Distribution SystemSDR AWXA9500378Eel Assy · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMEREGNCY EXIT LIGHTS INOPERATIVE ROW 16 THROUGH ROW 21. RECONNECTED LIGHT ASSEMBLY AT ROW 21, OPS CHECK GOOD. (M)Jun 14, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500356Eel Connectors · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND SEVERAL EMERGENCY EXIT LIGHTS INOPERATIVE BETWEEN ROW 11 AND ROW 19. RESEATED CONNECTIONS, OPS CHECK GOOD. (Z)Jun 5, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500354Position · malfunctionedLAS-PHX - FLT 1229 - ON CLIMB-OUT, UNABLE TO RAISE FLAPS PAST FLAPS 1. AIRCRAFT RETURNED TO LAS AND LANDED WITHOUT FURTHER PROBLEMS. MAINTENANCE FOUND FLAP POSITION INDICATOR BAD. REMOVED AND REPLACED FLAP POSITION INDICATOR. FLAPS WERE CYCLED NUMEROUS TIMJun 5, 1995 · N313AW · Boeing 7373S3 · Trailing Flap Position Indicating SystemSDR AWXA9500335Eel Fuses · inoperativePHX - DURING ROUTINE MAINTENACNE CHECK, FOUND FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 16 THROUGH ROW 20. STRAIGHTENED BENT PINS ON CONNECTOR D3688 AND REPLACED THREE FUSES IN EMERGENCY CHARGERS M1197 AND M1137. OPS CHECK GOOD. (M)Jun 1, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500326Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIRED WIRE AT MID CABIN, OPS CHECK GOOD. (M)May 26, 1995 · N314AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500322Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 13 AFT. REPAIRED BROKEN WIRE AT ROW 13, OPS CHECK GOOD. (W)May 22, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500307Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND ROWS 3 THROUGH 11 EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIRED BROKEN WIRE AT ROW 3. OPS CHECK GOOD. (M)May 21, 1995 · N315AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500299Eel Harness · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 14 BACK. RECONNECTED HARNESS PINS TO LIGHT AT ROW 14, OPS CHECK GOOD. (M)May 18, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500261Eel · damagedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS DAMAGED AND INTERMITTENT. REPAIRED WIRING, AND REMOVED AND REPLACED LIGHT TRACK AND ASSY, OPS CHECK GOOD.May 4, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500260Eel Wiring · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 13 THROUGH 22. RECONNECTED WIRE AT ROW 13, OPS CHECK GOOD. (W)May 3, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500258Eel Wiring · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 12 TO 15. REPAIRED BROKEN WIRE AT ROWS 12 TO 15. REPAIRED BROKEN WIRE AT ROW 12, OPS CHECK GOOD. (W)May 2, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500257Eel Assemblies · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. RECONNECTED LIGHTS AND WIRING IN SEVERAL AREAS, OPS CHECK GOOD. (W)May 1, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500253Light Assy · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 14 AFT. RECONNECTED AND INSTALLED LIGHTS, OPS CHECK GOOD. (X)Apr 30, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500251Light Assemblies · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 17 TO AFT OF AIRCRAFT. RECONNECTED SEVERAL LIGHT ASSEMBLIES, OPS CHECK GOOD. (X)Apr 28, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500236Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND LAST 7 ROWS OF FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE. SPLICED WIRES, OPS CHECK GOOD. (Z)Apr 17, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500221Eel Wire · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 9 THROUGH 11 AND FIRST CLASS. REPAIRED LIGHTS AT ROWS 9 THROUGH 11, AND RECONNECTED WIRES IN FIRST CLASS SECTION. OPS CHECK GOOD. (Z)Apr 16, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500220Eel Wiring · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS IN AFT SECTION INOPERATIVE. REPAIRED WIRING, SYSTEM OPS CHECK GOOD. (Z)Apr 16, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500216Eel Batt Pack · dischargedPHX - DURING ROUTINE MAINTENANCE CHCEK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE ROWS 7 THROUGH 13. REMOVED AND REPLACED EMERGENCY BATTERY PACK, OPS CHECK GOOD. (Z)Apr 11, 1995 · N313AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500187Eel Wiring · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND NUMEROUS FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. REATTACHED WIRING TO LIGHT MODULES AT SEVERAL LOCATIONS, OPS CHECK GOOD. (Z)Mar 28, 1995 · N316AW · Boeing 7373S3 · Emergency LightingSDR AWXA9500127Door · looseLAS-MDW - FLT 692 - ACFT DIVERTED INTO DENVER DUE TO SUSPECTED FUEL LEAK ON THE RT WING IN AREA OF NR 2 PYLON. CONTRACT MX INSPECTED AND RETORQUED FUEL TANK ACCESS DOOR ASSEMBLY AT WBR 227. NO FURTHER LEAKS REPORTED AT THIS TIME. ACFT RETURNED TO SERVICE. Mar 3, 1995 · N316AW · Boeing 7373S3 · Wing, Plate/SkinSDR AWXA9500130Eel Batt Charger · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS IN AFT AND REAR SECTIONS OF AIRCRAFT INOPERATIVE. REMOVED AND REPLACED RT AND LT AFT BATTERY CHARGER ASSEMBLIES, OPS CHECK NORMAL. (Z)Feb 27, 1995 · N316AW · Boeing 7373S3 · Emergency Lighting
Back to Boeing 737-3S3