Boeing 737-4B7
Service difficulty reports · 5,757
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7374B7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7374B7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA051458Floorbeam · corrodedFLOORBEAM AT STA 344 BL 0 TO LBL 25 CORRODED. MAJOR REPAIR, BLENDED AREA, ALODINED AND PAINTED IAW SRM 53-10-51, DEFECT SIZE: .250 INCH.SDR USAA051457Stringer Clip · crackedBS 727D, S5R CRACKED. MAJOR REPAIR, REMOVED AND REPLACED WITH IDENTICAL PART, IAW SRM 51-10-02, DEFECT SIZE: .18 INCH.SDR USAA051456Crease Beam · corrodedSTA 578 TO 601 LEFT CORRODED. MAJOR REPAIR, REMOVED CORROSION AND TREATED AREA IAW SRM 53-60-13, DEFECT SIZE: .250 INCH.SDR USAA051455Stringer Clip · crackedS-4L, BS 727C CRACKED. MAJOR REPAIR, REPLACED WITH IDENTICAL PART IAW SRM 51-10-02, DEFECT SIZE: .25.SDR USAA051464Stringer Clip · crackedS-4L, BS 727C CRACK. MAJOR REPAIR, REPLACED WITH IDENTICAL PART IAW SRM 51-10-02, DEFECT SIZE: .25 INCH.SDR SB05164Light · inoperativeCLT - MAINTENANCE REPORTED THE EMERGENCY EXIT LIGHT AT SEAT 11ABC INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LIGHT ASSEMBLY AT SEAT 11ABC. OPERATIONAL CHECK GOOD.SDR SB05163Battery Pack · dischargedMCO - MAINTENANCE REPORTED THE EMERGENCY LIGHTS IN THE FORWARD CABIN INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK IN THE FORWARD LEFT-HAND CABIN. OPERATIONAL CHECK GOOD.SDR SB05161Transmitter · faultyON DESCENT, AT 3,000 FEET, CREW RECEIVED A FLAP LOCKOUT AT 5 UNITS FLAP SETTING. AIRCRAFT DID NOT EXPERIENCE ANY ROLL AND THE CREW SUSPECTS THE WARNING WAS AN INDICATION PROBLEM. CREW DECLARED AN EMERGENCY AND DIVERTED, DUE TO LONGER RUNWAYS. FLIGHT LANDED WITSDR SB05160Battery Pack · dischargedCLT - MAINTENANCE REPORTED THE EMERGENCY EVACUATION AISLE LIGHTS AT ROWS 14R, 16L, 18R AND 23L INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE M1435 BATTERY PACK. OPERATIONAL CHECK GOOD.SDR USAA051442Rib · gougedFOUND AILERON NOSE RIB GOUGED LT WING OUTBD HINGE OUTBD SIDE LWR SURFACE. REPLACED, FABRICATED NOSE RIB IN LT AILERON PER SRM 51-40-02, DEFECT SIZE: .75"L X .375"W.SDR USAA051446Angle · corrodedFOUND CABIN FLOOR, DOOR SILL ANGLE SUPPORT STA 957-986, LBL 55, CORRODED. REMOVED AND REPLACED NEW DOOR SILL CHORD PER SRM 51-40-02; CORROSION TASK C53-107-01, DEFECT SIZE: 2"L BY 3"W BY .03"D.SDR USAA051445Stringer Splice · crackedFOUND CRACK, STR SPLICE BET STA 904-913, S4L. REMOVED 7, REPLACED FAB STRINGER SPLICE PER SRM 51-40-02, DEFECT SIZE: .25".SDR USAA051453Crease Beam · corrodedFOUND CORROSION CREASE BEAM FROM STA 615 TO 639. REMOVED CORROSION, TREATED AND ALODINED AND PRIMED IAW 53-60-13, DEFECT SIZE: 1" CORROSION AREAS.SDR USAA051443Shear Web · crackedFOUND CRACK MAIN CABIN FLOOR, STA 500-520 BL0. REMOVED AND REPLACED UPPER CHORD IAW SRM 51-40-02, DEFECT SIZE: .5, .75, .725, .5, 3.0 CRACKS AT FASTENER HOLES.SDR USAA051433Support · corrodedFOUND SMALL ZEE SUPPORT ON TOP OF AFT SERVICE DOORWAY Z ANGLE. REMOVED CORROSION, TREATED AND PRIMED IAW 53-60-15, DEFECT SIZE: 1" CORROSION TOP AND BOTTOM OF AFT SERVICE DOORWAY Z ANGLE.SDR USAA051441Splice · crackedFOUND STRINGER SPLICE BET APPROX STA 903-915, S4R. REMOVED 7, REPLACED FAB STRINGER SPLICE PER SRM 51-40-02, DEFECT SIZE: .25".SDR USAA051440Shear Web · crackedFOUND CRACK CABIN FLOOR SHEAR WEB, BET STA 380-400, BL0. INSTALLED FAB SHEAR WEB UPPER CHORD ANGLE PER SRM 51-40-02, DEFECT SIZE: 2.5".SDR USAA051439Floorbeam · corrodedFOUND CORROSION MAIN CABIN STA 312 RBL 21 FLOORBEAM UPPER CORD; CORROSION TASK C53-107-02. REMOVED AND REPLACED FLOORBEAM UPPER CORD AND L ANGLES AND INSTALLED SHIMS IAW SRM 53-10-5, DEFECT SIZE:SDR USAA051438Angle · corrodedFOUND SERVICE DOOR SILL AREA CORRODED AT STA 295 RBL 53. REMOVED AND REPLACED ZEE ANGLE; IAW SRM 51-40-02; CORROSION LEVEL 1; TASK C53-107-01 DEFECT SIZE: 4.5" BY 2.125".SDR USAA051437Intercostal · corruptedFOUND CRACK MAIN CABIN FRAME INTERCOSTAL STA 294, STR 11L. REMOVED AND REPLACED INTERCOSTAL PER SRM 51-80-02, DEFECT SIZE: 2.5"SDR USAA051436Intercostal · crackedFOUND MAIN CABIN STA 294, STR 16L, DOOR CUTOUT INTERCOSTAL CRACKED. REMOVED AND REPLACED INTERCOSTAL AFT FAB PART, PER SRM 51-70-11 & 53-10-15, DEFECT SIZE: 2".SDR USAA051435Floorbeam · corrodedFOUND CORROSION MAIN DECK STA 344, LBL 0; CORROSION LEVEL 1; TASK C53-107-02. FABRICATED REPAIR PARTS, INSTALLED REPAIR FILLER AND ANGLES PER SRM 53-10-51, 51-40-02, DEFECT SIZE: 2.50"L BY 1.10"W BY .031"D.SDR USAA051434Stringer Clip · crackedFOUND CRACK STA 663.75, S-10R. INSTALLED NEW TIE CLIP IAW 51-10-02, DEFECT SIZE: 1/2" CRACK.SDR USAA051444Intercostal · corrodedFOUND CABIN FLOOR INTERCOSTAL AT STA 307, RBL 15.5 CORRODED. REMOVED AND REPLACED, FABRICATED ANGLE PER SRM 51-40-02; CORROSION TASK C53-107-02, DEFECT SIZE: 1" BY 1".SDR SB05157Transmitter · faultyON APPROACH, THE FLAPS STOPPED AT 2 UNITS WHEN SELECTED TO 5 UNITS. CREW ACCOMPLISHED GO-AROUND. WHILE PERFORMING QUICK REFERENCE HANDBOOK PROCEDURES, FLAPS WENT TO 5 UNITS AND WORKED NORMAL UNTIL SELECTION OF 30 UNITS. LT FLAP INDICATION SHOWED 125 UNITS, WHISDR USAA051408Skin · defectiveFWD CARGO DOOR, OUTSIDE SKIN, CENTER SECTION AREA DEFECTIVE. REPAIRED SRM 52-00-01, INSTALLED DOUBLER, DEFECT SIZE: 14 INCHES X 20 INCHES.SDR SB05149Bulb · weakCLT - PILOT REPORTED THE COCKPIT EMERGENCY EXIT FLOODLIGHT IS VERY DIM ON EMERGENCY BATTERY POWER. MAINTENANCE VERIFIED CORRECT VOLTAGE OF 6.13 VOLTS DC AT EMERGENCY LIGHT SOCKET. INSTALLED NEW BULB FOR EMERGENCY EXIT LIGHT. OPERATIONAL CHECK NORMAL.SDR USAA051367Skin · crackedFOUND CRACK, STATION 727D STRINGER 24R. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-01 FIG 201, DEFECT SIZE: 1.375".SDR USAA051350Frame · crackedFOUND FWD SERV DOOR CUTOUT FWD FRAME AT LOWER O/B CORNER OF FWD UPPER STOP FITTING CRACKED. TRIMMED OUT DAMAGE AREA AND FABRICATED NEW FRAME AND INSTALLED IAW SRM 51-40-02 AND SRM 51-40-03, DEFECT SIZE: 3/16" CRACK.SDR USAA051349Frame · crackedFOUND BS 400 AT STRINGER 8R CRACKED. REPAIRED IAW T/R 53-10-20C, DEFECT SIZE: 1/4" CRACK.SDR USAA051353Attach Angle · crackedFOUND STA 500C AT FUSELAGE FRAME AND ATTACH ANGLE CRACKED. REMOVED CRACK, FAB AND INSTALLED REPAIR STRAPS IAW EA 97079, DEFECT SIZE: 1/2" CRACK.SDR USAA051337Angle · corrodedAFT CARGO FLOOR LT ZEE ANGLE FUSELAGE STATION 727D TO 747 LEVEL 1 CORROSION. REMOVED DAMAGED ANGLE AND INSTALLED A NEW ANGLE IAW SRM 51-10-02. DEFECT SIZE: 18 X .75 INCHES.SDR USAA051338Skin · crackedCARGO DOOR CUTOUT FWD FRAME INNER SKIN AT LWR END 2ND RIVET UP FROM S26R CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 51-70-13 BOEING DWG 69-15224. DEFECT SIZE: .5 INCH.SDR USAA051343Beam · corrodedBEAM 312 LEVEL 1 CORROSION. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS, IAW SRM 53-10-51 REPAIR 5. DEFECT SIZE: 5 INCHES.SDR USAA051344Stringer Splice · crackedSTA 907 AND STR 4R CRACKED. REMOVED DAMAGE AND INSTALLED STRINGER SPLICE. DEFECT SIZE: 1 INCH.SDR USAA051345Intercostal · corrodedNUMEROUS CLIP NUT HOLES BETWEEN 294.5 AND 312 RBL 10. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-02. DEFECT SIZE: .250 INCH.SDR USAA051346Attach Angle · crackedSTA 500C LT FUSELAGE FRAME AND ATTACH ANGLE CRACKED. REMOVED CRACK, FABRICATED AND INSTALLED REPAIR STRAPS IAW EA 97079. DEFECT SIZE: .50 INCH.SDR USAA200511004Skin · crackedA 1.5 INCH CRACK FOUND AT BS 944 S-24L. INSTALLED DOUBLER PER EA 97050.SDR USAA051335Beam · crackedVERTICAL FIN RIGHT AFT LOWER T/E AREA, THE I/B FLANGE OF THE TRAILING EDGE. REPLACED CRACKED BEAM, IAW SRM 51-40-02. DEFECT SIZE: 6 INCHES.SDR USAA051336Angle · corrodedJUST INBOARD OF FWD SERVICE DOOR THRESHOLD. REPLACED WITH IDENTICAL PART, REMOVED DAMAGED Z-ANGLE IAW SRM 51-40-02. DEFECT SIZE: 3 X 7.3 INCH.SDR USAA051328Skin · wornINBOARD LEADING EDGE. FABRICATED DOUBLER AND INSTALLED IAW SRM 57-53-01. DEFECT SIZE: 1 X 8 INCH DEEP WEAR AREA ON LEADING EDGE.SDR USAA051329Tie Clip · crackedTIE CLIP S25L STA 400 CRACKED. REPLACED WITH IDENTICAL PART, REMOVED & REPLACED TIE CLIP IAW SRM 51-40. DEFECT SIZE: .1875 INCH CRACK.SDR USAA051330Nut Plate · corrodedENTRY DOOR FLOOR LEVEL CORROSION. FABRICATED AND INSTALLED NEW NUT PLATE HOLDER PLATE IAW SRM 53-00-50. DEFECT SIZE: 2 X 6 INCH CORROSION.SDR SB05143Filter · dirtyON SHORT FINAL, THE FLIGHT ATTENDANTS REPORTED FUMES IN THE CABIN. WITH PACKS ON HIGH, FUMES DECREASED. WITH PACKS ON AUTO, FUMES INCREASED. FLIGHT LANDED WITHOUT FURTHER INCIDENT AND TAXIED TO THE GATE. MAINTENANCE INSPECTED LEFT AND RIGHT PACK BAY AREAS SDR USAA051317Skin · damagedRUDDER SKIN LT SISE STATION 233.9. DOUBLER INSTALLED ON LT UPPER SIDE OF RUDDER IAW SRM 51-60-05, DEFECT SIZE: 7 INCHES X 1INCH.SDR USAA051318Stringer Clip · crackedLOCATION: BS360 AND S4R. DEFECTIVE PART REPLACED WITH IDENTICAL PART, IAW SRM 51-10-02 DEFECT SIZE: .50 IN.SDR USAA051322Skin · damagedNR 1 SLAT WITH FLUSH PATCH. MAJOR REPAIR IAW SRM 57-43-01, DEFECT SIZE: 5.5" BY 3.5".SDR USAA051323Floorbeam · corrodedFLOORBEAM AT RT SERVICE DOOR ENTRY WAY. INSTALLED NEW REPAIR PART IAW SRM 51-40-02 DEFECT SIZE: 2 INCHES X 5 INCHES.SDR USAA051324Clip · crackedNR 3 FLAP TRACK STRUCTURE IB SIDE, AFT END. FABRICATED AND INSTALLED NEW ANGLE IAW SRM 51-10-02 DEFECT SIZE: 1 INCH.SDR USAA051325Door Frame · crackedLOCATION: AFT DOOR CUTOUT AFT FRAME AT S25R. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 51-70-13. DEFECT SIZE: 1 INCH
Back to Boeing 737-4B7