Boeing 737-832
Service difficulty reports · 9,905
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737832' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737832' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL738050667Socket · looseDURING PUSHBACK AFT FLT ATTENDANT REPORTED THE AFT GALLEY (PORT SIDE) NO SMOKE/SEAT BELT SIGN HANGING OUT OF SOCKET. WHEN PUTTING SIGN BACK IN THE WIRING STARTED SPARKING, WITH SMELL OF SPARKING. DROPPED ALL ELEC OFF LINE, RETURN TO GATE AREA. FOUND C/B POPSDR DL78K050594Bulkhead · canningOIL CANNING FOUND IN THE BS 1016 AFT PRESSURE BULKHEAD AT APPROX RBL 10 & WL 290. DAMAGE CUT OUT AND REPAIR DOUBLER INSTALLED.SDR DL738050510Bulb · burned outEMERGENCY LIGHTS OVERHEAD INOP AT 31B 32D 24B 01B. RELAMPED, ALL CHECKS OK.SDR DL738050442Rod · brokenDURING ROTATION LOUD POP NEAR COCKPIT. GEAR CAME UP NORMALLY WITH LIGHTS OUT. GEAR LOWERED, GEAR NORMALLY ALL GREEN. RETURNED TO TPA. MTC FOUND L NLG DOOR PUSH ROD BROKEN. REPLACED SAME PER MM.SDR DL738050410Power Supply · inoperativeEMERGENCY ESCAPE LIGHT ABOVE SEAT 10D INOP. REPLACED POWER SUPPLY FUSE. LIGHT OP CKS GOOD.SDR DL738050380Apu · smokeON L/O, FOUND APU LOW ON OIL. SERVICED APU. ON APU START ATTEMPT, FOUND HEAVY SMOKING IN APU COMPARTMENT WITH TORCHING FROM APU EXHAUST. REPLACED APU.SDR DL738050357Odor · detectedFIVE MINS AFTER T/O A BURNING ODOR NOTICED IN COCKPIT. ODOR WAS ACRID ELECTRICAL SMELL WITH A LIGHT HAZE IN THE COCKPIT. SMOKE CLEARED WITH PACKS ON HIGH. RAN ENGINES AND PACKS AT ALL PWR SETTING. CK'D OPERATION OF LT AND RT RECIRCULATION FANS. ALL NORMALSDR DL78K050338Bulb · burned outEMERGENCY EXIT LIGHT HAS BULBS AND LIGHT ASSY BROKEN AT SEAT 15E. RELAMPED EMERGENCY LIGHT.SDR DL738050308Bellcrank · brokenCREW VERBAL A/C TOOK 2 DEGREES TRIM WITH FLAPS DOWN ON LANDING. FOUND WITH FLAPS DOWN RIGHT O/B FLAP I/B ATTACH POINT BELLCRANK BROKEN. REPLACED SAME.SDR DL738050287Cover · looseNR 1 ENG OIL QTY TOP ZERO. ENG OIL PRESS TO REDLINE. FLT CREW COMPLETED ENG FAILURE SHUTDOWN PER QRH CHECK LIST. UNEVENTFUL SINGLE ENG LANDING AT SLC. NR 1 ENG WINDMILL WITH POS PRESS AT ALL TIMES. FOUND NR 1 ENG TURNING PAD COVER LOOSE. REPLACED O-RINGSSDR DL738050271Pneumatic System · contaminatedABORTED T/O FOR SMOKE IN COCKPIT AND CABIN. PERFORMED OIL CONTAMINATION REMOVAL FROM AIR COND AND PNUEM SYS. NO SMELL OF CONTAMINATION NOTED. RAN PACKS AND ENGS TO T/O. NO SMOKE NOTED.SDR DL738050175Smoke · detectedREJECTED TAKEOFF AT 125 KTS WITH SMOKE IN COCKPIT. USED APU FOR NO BLEED TAKEOFF AND LEFT PACK. PERFORMED DUCT BURN OUT FROM GROUND AIR CONNECTION FOR APU AND ENGINES. RAN PACKS NO EVIDENCE OF ELECTRICAL OR GLYCOL SMELL.SDR DL738050166Pump · unserviceableNR 2 ENG HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED. AFTER ABOUT 1 HOUR B-SYSTEM FLUID LEVEL DECREASED TO ZERO. FOUND FLUID LEAKING FOR ENG DRIVEN HYD PUMP. REPLACED ENG HYD PUMP AND ELECT HYD PUMP. REPLACED EMDP AND EDP PRESSURE FILTER AND CASE DRAIN FILTERSDR DL738050156Ballast · overheatedTWENTY MINUTES IN FLT F/A REPORTED ELEC FUMES IN THE AFT GALLEY. THE F/A CHECKED OVENS AND COFFEEMAKERS AND THERE WERE NO PROBLEMS. THE FLT PERFORMED THE QRH PROCEDURES BY SECURING THE GALLEY PWR AND FAN C/B. MTC FOUND THE LIGHT BALLAST FOR THE AFT GALLEY OSDR DL738050129Fuse · blownEMERGENCY LIGHTS FROM SEAT ROW 23 AFT INOP. REPLACED FUSE IN EMERGENCY BATTERY CHARGER M1672.SDR DL738050123Light · brokenGALLEY 2R EMERGENCY LIGHT DAMAGED. REPLACED LIGHT.SDR DL738050108Valve · failedAS POWER WAS SET FOR T/O RT BLEED TRIP OFF LIGHT ILLUMINATED, 20 KTS ABORTED T/O. ACCOMPLISHED NNC PROCEDURE. THERE WAS A SPLIT ON LT AND RT DUCT PRESSURE. AFTER RESET, BLEED OPENED AND LT AND RT DUCT PRESSURE RETURNED TO NORMAL. REMOVED AND REPLACED PRECSDR DL738050092Filter · cloggedOIL FILTER BYPASS LIGHT ON RT ENGINE ILLUMINATED. REPLACED FILTER BOWL ASSY.SDR DL738050047Engine · leakingAFTER 1 HR 30 MIN RIGHT ENGINE OIL QTY WENT TO 4 WITH A LOW LIGHT. AFTER 40 MORE MINUTES OIL QTY WENT TO 3. DESCENT QTY WENT TO 5. AFTER SHUTDOWN QTY WENT TO 12. SERVICED NR 2 ENGINE WITH 26 PINTS OF OIL BAGGED ENGINE DRAINS AND RAN AT PWR. NO LEAKS NOTEDSDR DL738050025Oven · odorFLT ATTENDANT SMELLED ELECT SMOKE FROM SEAT AT 1L DOOR. PERSISTED 3 TO 4 MIN, THEN DISSIPATED. A/C RETURNED TO JFK. FLT ATTENDANT REPORTED SMELL ONLY, NO SMOKE. SUSPECT RESIDUAL FUMES FROM DEACT OVEN, IN FWD GALLEY. REMOVED CONNECTORS FROM OVEN AND DEACT SDR DL738050021Module · contaminatedENG 1 AND ENG 2 HYD PUMPS LOW PRESS LIGHTS ILLUM IN FLT. FOUND EVIDENCE OF MOISTURE/WATER IN HYD RSVR PRESS MOD. DISCONNECTED LINES AT HYD RSVR PRESS MODULE & AT -A- AND -B- RSVRS. BLEW LINES WITH DRY NITROGEN. REPLACED HYD RSVR PRESS MODULE AND RECONNECTSDR DL738050017Shutoff Valve · malfunctionedLEFT ENGINE BLEED TRIPPED OFF AROUND 20000 FT, COULD NOT RESET. ENG DUCT PRESS WAS SPLIT L-15 AND R-40 PSI ON CLIMBOUT. T/S PER FIM. REPLACED PRECOOLER CTL VLV AND PRSOV PER MM. REPLACED REDUCER FOR BLEED AIR REG SUPPLY LINE. ALL LEAK CHECK GOOD. RAN ENGSDR DL738050013Shutoff Valve · leakingLEFT ENGINE BLEED TRIP OFF AROUND 20K FT, COULD NOT RESET. ENGINE DUCT PRESSURE WAS SPLIT L-15 RT 40 PSI ON CLIMBOUT. REPLACED LEFT PRSOV RAN ENGINE AT POWER, OPS OK.SDR DL738050012Bellcrank · brokenWHEN FLAPS EXTENDED TO 1 AT 210 KTS AIRCRAFT ROLLED LEFT, BEYOND 1, ROLL MOMENT REMAINED. FOUND LT OUTBOARD AFT FLAP CONTROL BELLCRANK BROKEN. REPLACED SAME.SDR DL738050006Heat Exchanger · leakingAFTER TAKEOFF RAMP REPORTED TO TMC THAT NR 2 ENG WAS LEAKING FUEL ON TAXI OUT OF SMF. AIRCRAFT DIVERTED INTO SFO FOR MTC. MTC IN PROGRESS. FOUND FUEL/OIL HEAT EXCHANGER LEAKING. REPLACED SAME.SDR DL738050001Spring · missingLEFT MAIN GEAR DID NOT RETRACT, RED GEAR LIGHT REMAINED ILLUMINATED WITH GEAR IN OFF POSITION. BOTH GREEN GEAR DOWN INDICATIONS OVERHEAD AND MAIN CONSOLE WERE ILLUMINATED. FOUND ONE LT MLG UPLOCK SPRING MISSING. REPLACED BOTH SPRINGS. JACKED A/C AND PERFORSDR DL738041092Fuse · blownON L/O FOUND EMERGENCY LIGHTS AT SEAT ROW 22D AFT INOP. SWAPPED BATTERY PACK, NO HELP. FOUND AFT RT POWER SUPPLY BAD. REMOVED POWER SUPPLY AND BATTERY PACK. BATTERY CHARGER HAS A BAD FUSE. REPLACED FUSE REF M/M. REPLACED BATTERY AND REINSTALLED CHARGER. SDR DL738041074Battery · missingCABIN ROGER UNIT SMOKED IN FLIGHT. BATTERIES REMOVED BY FLIGHT ATTENDANT. CABIN ROGER UNIT NR 1995 SER NUMBER 101433 REMOVED FROM A/C BY GATE GOURMET.SDR DL738041070Arm · crackedCAPTAINS WINDSHIELD WIPER ARM BROKE OFF .25 INCH ABOVE TENSIONING MECHANISM.SDR DL738041067Wheel · separatedNOSE WHEEL TIRE PROBLEM ON TAKEOFF. REPLACED BOTH NOSE WHEELS.SDR DL738041050Chiller · odorCREW REPORTED BURNING ODOR FROM FORWARD GALLEY CHILLER. TURNED CHILLER OFF AND SMELL WENT AWAY. REPLACED CHILLER.SDR DL738041032Fitting · brokenON TAXI OUT ENG NR 1 A-HYD PUMP FAILED. REPLACED SUPPLY HOSE.SDR DL738041001Video Display · failedAPPROX 2.5 HRS INTO FLT, FLIGHT ATTENDANT REPORTED STRONG ELEC FUMES AFT OF OVERWING EXITS. AT SAME TIME VIDEO SCREENS RETRACTED/EXTENDED ON THEIR OWN AFT OF ROW 23. VIDEO 3 C/B WAS POPPED. FLT CREW PULLED REMAINING VIDEO C/B`S AND ENTERTAINMENT C/BS. FUMSDR DL738040992Pump · failedRT ENG FAILED CLIMBING THUR 28000. ALL INDICATIONS PRIOR TO FAILURE WERE NORMAL. REPLACED NR 2 HMU AND FUEL PUMP.SDR DL738040986Door · unsafetiedFLT 473 SAN - JFK DIVERTED TO LAX, LOUD AIR LEAK NOISE FROM 1L DOOR AND NO PRESSURIZATION. FOUND 1L DOOR AFT EDGE NOT FULLY CLOSED. INSPECTED DOOR AND SEAL, CYCLE SEVERAL TIMES, PRESSURIZED ACFT, AND ALL CHECK NORMAL. NO PARTS REQUIRED.SDR DL738040920Bulb · inoperativeEMERGENCY LIGHT AT 15D BULLNOSE INOP. RELAMPED, CHECK GOOD.SDR DL738040905Bulb · burned outLEFT OVERWING AFT EMERGENCY LIGHT INOP. RELAMPED SAME, OPS NORMAL.SDR DL738040885Odor · detectedFLIGHT ATTENDANT REPORTED A STRANGE INTERMITTENT SMELL AFT OF LAST SECTION OF SEATS ON CAPTS SIDE. TURNED OFF LIGHTS AND SMELL DID NOT RETURN. TURNED LIGHTS ON, NO SMELLS NOTED. RAN PACKS NO ODORS NOTED PER CREW COMMENT SMELL COULD HAVE BEEN EMITTED FROM A SDR DL738040869Pump · failedLOW PRESS LIGHT ON SYS-A ELECT HYD PUMP CAME ON AND A-SYS HYD QTY STEADILY DECREASED TO 21 PERCENT THEN SYS PRESS BEGAN FLUCTUATING. COMPLIED WITH QRH NNC 13.2. REPLACED FAILED AND LEAKING A SYS ELECT HYD PUMP AND FILTERS.SDR DL738040863Bulb · inoperativeEMERGENCY LIGHT ABOVE 14C INOP. RELAMPED, OPS NORMAL.SDR DL738040803Actuator · bypassingAFTER TAKEOFF UPON FLAP/SLAT RETRACTION THE LEADING EDGE SLATS LOCKED OUT. TROUBLESHOOTING PER MAINTENANCE MANUAL AND BOEING SERVICE BULLETIN, FOUND NUMBER 1 AND NUMBER 8 LEADING EDGE SLAT ACTUATORS BYPASSING. REPLACED BOTH ACTUATORS PER M/M, OPERATIONAL CHSDR DL738040775Fcu · malfunctionedLE FLAP TRANSIT LIGHT AMBERON FLAP RETRACT DURING TAKEOFF/ DEPARTURE. LE SLATS 2, 3 AMBER ILLUMINATED. AFTER CYCLING FLAPS TO 1 AND BACK TO UP IAW CHK LIST, LE SLATS 2,3 6 AND 7 TURNED AMBER. RETURNED FLAPS 15 FOR LANDING. 225 KNOTS MAX AIRSPEED DURING FLIGSDR DL738040687Bulkhead · puncturedTHE FS 178 BULKHEAD ASSY WAS DAMAGED BY CONTACT WITH A JETWAY AT WL 230 NEAR RBL 30. THE RBL 17 BEAM, THE UPPER BULKHEAD AND RT SIDE CHORD WERE DAMAGED AND REPLACED. THE BULKHEAD WEB DAMAGE WAS REMOVED WITH A CUTOUT AND REPAIRED WITH TWO ALUMINUM REPAIR DOUBSDR DL738040686Skin · puncturedTHE FUSELAGE SKIN WAS PUNCTURED JUST AFT OF THE FS 178 BULKHEAD BELOW WL 234 FROM CONTACT WITH A JETWAY. THE DAMAGE WAS REMOVED WITH A 8.25 X 4.5 INCH CUTOUT AND REPAIRED WITH AN INTERNAL REPAIR DOUBLER PER ER/A 091962-14, REV A.SDR DL78K040608Battery Pack · inoperativeAFT OVERWING RIGHT EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK.SDR DL738040593Pitot Tube · inoperativeRIGHT ELEVATOR PITOT HEAT INOP. REPLACED THE RIGHT ELEVATOR PITOT PROBE PER M/M 27-31-94-000-801.SDR DL738040509Oxygen Mask · leakingACFT OFF SCHEDULED ORD DUE TO C/P 02 MASK WOULD NOT SHUT OFF AND WAS DEPLETING 02 BOTTLE. REPLACED MASK.SDR AUS20040465Brake · failed(AUS) NR 3 BRAKE ASSEMBLY, BRAKE PADS SEPARATED AND JAMMED THE BRAKE ONTO THE WHEEL.SDR DL78K040467Fseu · failedRETURN TO ATL, WITH LEADING EGDE SLAT NR 1 AND LEADING EDGE FLAPS NR 1 AND NR 4, REMAINING ILLUMINATED AMBER ON AFT OVERHEAD ANNUNCIATOR, LE FLAP TRANSIT REMAINED ILLUMINATED CREATING LE LOCKOUT NO ADVERSE ROLL. REPLACED FSEU FOR FAULT CODE 27-51105.SDR DL738040464Spar · damagedRT IB MAIN FLAP FRONT SPAR LOWER CHORD FOUND TO BE DAMAGED. DAMAGE WAS LOCATED BETWEEN 26 INCHES AND 34 INCHES FROM THE IB END OF SPAR. DAMAGE WAS REMOVED AND REPAIR INSTRUCTION ISSUED IAW ERA 090294-14.
Back to Boeing 737-832