SDR AMTA200700501Attach Fitting · damagedUPON INNSPECTION OF FORWARD SPAR ATTACHMENT BOLTS FOUND THE RT LOWER AND RT UPPER BOLTS DEFECTIVE, GALLING AND FRETTING WEAR. COMPLIED WITH EO 737-55AD-2935, REPLACED (2) BOLTS WITH PN 180A1611-3. (K)SDR AMTA200700504Unknown · unknownAPU WOULD NOT POWER LEFT A/C BUSS. (K) 10-26-07 REMOVED AND REPLACED MODULE IAW AMM 24-21-51-4, OPS CHECK NORMAL PER AMM 24-21-00-5. (M)SDR AMTA200700500Floor Panel · corrodedAFT CARGO PNL 140BF STRAP HAS CORROSION ON LWR SURFACE STA 727D, LBL 25 - RBL 25. FABRICATED TEE STRAP IAW SRM 53-42-11-26. REPLACED TEE STRAP IAW 51-40-02. (K)SDR AMTA200700498Floor Panel · corrodedAFT CARGO PNL 140AF HAS CORROSION AROUND EDGES UPPER SURFACE STA 727+4 - 727D, LBL 25- 25 RBL. FABRICATED AFT CARGO FLOOR PNL 140AF ALODINED AND PRIMED, IAW SRM 53-60-53-0I, SRM 51-20-01-0G. (K)SDR AMTA200700497Floor Panel · corrodedAFT CARGO FLOOR PANEL 140CF HAS CORROSION AROUND EDGES OF UPPER SURFACE. FABRICATED AFT CARGO FLOOR PANEL 140CF ALODINED AND PRIMED IAW SRM 53-60-53, SRM 51-20-01-06. (K)SDR AMTA200700496Floor Panel · corrodedAFT CARGO FLOOR PANEL 140DF, (AFT) HAS CORROSION AROUND EDGES OF UPPER SURFACE STA 887- 947, LBL 14- RBL 25. FABRICATED NEW FLOOR PANEL IAW SRM 53-70-54-01 (2024 T-3 .071) ALODINED AND PRIMED IAW SRM 51-20-01. (K)SDR AMTA200700495Floor Panel · corrodedFWD CARGO FLOOR PANEL 120DF HAS CORROSION AROUND EDGES. UPPER SURFACE STA 500D-540, LBL 25- RBL 25. FABRICATED AFT CARGO FLOOR PANEL 120DF, ALODINED AND PRIMED, IAW 53-30-53-0I, SRM 51-20-01. (K)SDR AMTA200700494Floor Panel · corrodedFWD CARGO FLOOR PANEL 120BF HAS CORROSION ON EDGE OF UPPER SURFACE AS MARKED STA 440-500, LBL25-RBL 20. FABRICATED FLOOR PANEL 120BF, MAT`L 2024-T3, .071, IAW SRM 53-30-53-01, SRM 51-20-01-0E. (K)SDR AMTA200700489Wedge · damagedSAA, INSPECTION FOUND NUMEROUS DENTS, CRACKS AND PUNCTURES ON THE RT IB AFT FLAP WEDGE LOWER SKIN PN 133A2700-18. REPAIRED IAW EA`S 737-5753-09A1099 AND 737-5753-09A1098. REPAIR IS INTERIM AND REQUIRES RE-INSPECTION EVERY 3500 FLIGHT CYCLES OR 24 MONTHS WHICSDR AMTA200700488Wedge · puncturedINSPECTION FOUND NUMEROUS DENTS, CRACKS AND PUNCTURES ON THE LT IB AFT FLAP TRAILING EDGE WEDGE LOWER SKIN PN 113A2700-17. ACCOMPLISHED REPAIR IAW SAA EA 737-5753-09-A1098. (M)SDR AMTA200700487Unknown · unknownINSPECTION OF THE SECONDARY FUEL VAPOR-BARRIER APPLICATION, WING CENTER SECTION TOP PANEL AND FRONT SPAR, 7 EA AREAS FAILED INSPECTION. C/W EO737-57-AD3096. (K)SDR AMTA200700485Power Unit · inoperativeAPU WILL NOT START WITH BATTERY POWER ON. REMOVED AND REPLACED APU START POWER UNIT IAW AMM 49-41-71-4. OPS CHECK GOOD. (K)SDR AMTA200700475Warning Light · false activationAPU MASTER CAUTION LIGHT ILLUMINATED WHEN ELECT POWER TRS TO ENG DRIVEN GENERATORS REMAINS ILLUMINATED WHEN APU SHUTDOWN. INTERROGATED CDU PERFORMED BITE TEST ON APU NO RECENT FAULT OR ANY HISTORY FAULTS NOTED ON ANY LEGS, SHOT DOWD AC POWER CYCLE AC POWER APSDR AMTA200700473Sensor · unserviceableON CLIMBOUT OF LGA FLAPS FAILED TO RETRACT SHOWING ASYMETRIC CONDITION L 71/4 DEGREES R5 DEGREES. REMOVED AND REPLACED NR3 FLAP SKEW SENSOR IAW 27-59-01-2 OF MM OPS CHECK AND RIG CHECK GOOD. (K)SDR AMTA200700472Hinge · brokenRT AFT OVERWING EMERGENCY DOOR HINGE ASSY BROKEN. INSTALLED NEW SERVICEABLE DOOR HINGE IAW CMM 52-26-07. (K)SDR AMTA200700460Connector · disconnectedRT FWD EMERGENCY EXIT LIGHTING INOPERATIVE. FOUND CONNECTING PLUG FOR BATTERY DISCONECTED REINSTALLED. OPS CK NORMAL IAW 33-51-06-2. (K)SDR AMTA200700457Floor Support · corrodedAFT CARGO FLOOR SUPPORT HAS CORROSION FROM 787 TO 847 RBL 16.5. REMOVED CORROSION SRM 51-10-02 AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A2. FABRICATED FLOOR SUPPORT TRACK IAW EA 737-5300-09-A1104 AND INSTALLED IAW SRM 53-00-53-2R3 ITEM 4B 1 AND 2. TREATED SDR AMTA200700456Support Angle · crackedUPON REMOVAL OF AFT CARGO THRESHOLD WEB AT APPROX STA 810 FOUND SUPPORT ANGLE CRACKED. REMOVED SUPPORT ANGLE SRM 51-40-02 FAB NEW ANGLE ON TRAVELER 7773560001 LOCATED NEW ANGLE IAW SRM 51-40-01 INSTALLED SUPPORT ANGLE SRM 51-40-02. (K)SDR AMTA200700445Skin · dentedRT LOWER FUSE HAS AN APPROX 14 INCH GOUGE THAT ENDS IN AN APPROX 3 INCH X 50 DENT, STA 797 BETWEEN STR 24R AND 27R JUST BELOW CARGO DOOR. REPAIRED IAW SAA EA 737-5361-09-A1102 24 MONTH TIME LIMITED REPAIR AND TRACKED BY ATA ERA 737-53R-6158. TREATED PRIMED ASDR AMTA200700462Duct · missingLT PACK ILLUMINATED DURING CLIMB PACK RESET BUT ILLUMINATED AGAIN TEMP WAS ABOUT 185. FOUND DISCHARGE DUCT TO ACM MISSING COUPLING, SECURED DUCT AND INSTALLED NEW COUPLING, LEAK CHECK GOOD, OPERATED PACK, TEMP 60 DEGREES NORMAL, PERFORMED BITE IAW FIM 21-62-0SDR AMTA200700461Circuit Breaker · unknownATTITUDE DISPLAY ON STANDBY ISFD DISAGREES WITH PIMARY DISPLAY. NO FLAG SHOWS. RESET CB STBY DEDICATED BATTERY CHARGER IAW FIM 34-24-00-810-814. (K)SDR AMTA200700442Battery Pack · inoperativeEMERGENCY LIGHTS (INTERIOR) BY 1L DOOR INOPERATIVE. REMOVED AND REPLACED BATTERY PACK. IAW AMM 33-51-06-960-805. OPS CHECK GOOD. (K)SDR AMTA200700426Acm · unserviceableLT PACK TRIPPED IN FLT RESET IAW TO CHECK LIST, PACK TRIPPED AGAIN. INSPECTED, REMOVED AND REPLACED DEFECTIVE ACM IAW AMM 21-51-04. GROUND OPS CHECK GOOD. LT PACK, OK FOR SERVICE. (K)SDR AMTA200700420Warning Light · false activationON LANDING, NR 2 REVERSER LIGHT ON AND OVERHEAD REVERSE ON LIGHT ON CYCLED REV. ONCE THEN BOTH REVERSER LIGHTS STAYED ON, CYCLED 2ND TIME BOTH REV LIGHTS OUT AND NR 2 ENGINE CONTROL LIGHT CAME ON, ON SHUTDOWN ALL PERFORMED BITE CHECK OF EAU PER FIM 78-31-00-8SDR AMTA200700416Fuel Control · malfunctionedDURING CREW PREFLIGHT, APU WOULD NOT START. PERFORMED FIM 49-40-00 FOR A (NO FLAME SHUTDOWN) MESSAGE SHOWN FOR APU BITE ON THE CDU. VERIFIED APU IGNITION AND STARTER OPERATION AS NORMAL. VERIFIED FUEL FLOW. REMOVED AND REPLACED FUEL CONTROL UNIT. (K)SDR AMTA200700415Warning Light · illuminatedPSEU LIGHT ON ATTEN ENG START. RESET PSEU, PERFORMED BITE TEST NO FAULTS, OPS CHECKED FLT CONTROL AND RUN ENG NO FAULT FOUND IAW AMM 32-09-00-810-801. (K)SDR AMTA200700397Apu · inoperativeAPU DOES NOT START. FAULT LIGHT ON. BITE APU, STARTED APU OPS CHECK GOOD REM 49-00-00. (K)SDR AMTA200700396Engine · unknownNR 1 ENGINE CONTROL LIGHT ON. PERFORMED FIM PROCEDURE 73-06-00-810-801 NO FAULTS NOTED OK FOR SERVICE. (K)SDR AMTA200700395Indication Sys · malfunctionedAFTER LANDING, ENGINE CONTROL LIGHT ILLUMINATED ON NR 1 ENGINE. PERFORMED BITE CHECK IAW FIM 73-06-00-810-801 CHECKED EEC HARNESS FOR SECRUITY RAN ENG NO DEFECTS NOTED OK FOR SERVICE. (K)SDR AMTA200700394Battery · inoperativeREAR GALLEY LT SIDE FLASHLIGHT DID NOT BLINK. REMOVED AND REPLACED GALLEY FLASHLIGHT BATTERY, OPS CHECK GOOD. (K)SDR AMTA200700389Warning Light · malfunctionedMASTER CAUTION AND ENG LIGHT SETTING STD THRUST. THROTTLES TO IDLE AND EXITED RUNWAY. ACCOMPLISHED EEC BIT IAW AMM 73-00-00-810-801 NO FAULTS NOTED. ALSO, RESET CB MASTER CAUTION AND CHECKED NR1 AND NR2 EEC CONTACTORS, OK FOR SERVICE. (K)SDR AMTA200700388Sensor · malfunctionedINITIAL CLIMB DUCT PRESSURE L-15, R42 PSI, AT 16,000, N1 96.3, L 13, R 32 PSI, AT 27,000, L13, R 26, N1 98.7 IN CRUISE AT 370, L18, R 28. ON DESCENT BOTH MATCH UP. REMOVED AND REPLACED NR 1 ENG 450 TEMP SENSOR IAW MM 36-11-05-4. (K)SDR AMTA200700380Light · brokenFWD GALLEY EGRESS WINDSCREEN PROX LIGHT ASSY BROKEN IN PIECES. REMOVED AND REPLACED LIGHT ASSY FOR FWD GALLEY EGRESS WINDSCREEN PROX. OPS CHECKS NORMAL. (K)SDR AMTA200700378Regulator · unserviceableDUCT PRESSURE SPLIT ON CLIMB AT 10,000 FT L14/ R34 20K, L13 R32, 30K, L13, R24, AT CRUISE 380K L16/R23. REMOVED AND REPLACED NR 1 ENG BLEED AIR REGULATOR IAW 36-11-03-4.SDR AMTA200700379A/C Pack · unknownRT PACK OVERHEAT LIGHT ON OVERHEAD WILL NOT RESET. PERFORMED PACK/ZONE TEMP. CONTR. BITE IAW MM 21-51-00-5. CONTRL NR 1 NO FAULTS. CONTR 2 SHOWS TCV. RESET CONTROLLER, OPS CHECK NORMAL. (K)SDR AMTA200700374Battery · dischargedF/A AFT RIGHT J/S FLASHLIGHT BATTERY LOW. REMOVED AND REPLACED BATTERY AS REQUIRED. OPS CHECK GOOD. (K)SDR AMTA200700375Charger · unserviceableISFD DISPLAY BLANK. REMOVED AND REPLACED THE DBC IAW 34-24-00, ISFD. OPS CHECKS GOOD. OK FOR SERVICE. (K)SDR AMTA200700366Computer · unserviceableLT FMC FAILED. REMOVED AND REPLACED LT FMC COMPUTER IAW AMM 34-61-02-4 AND OPS CHECK IAW AMM 34-61-00-5. (K)SDR AMTA200700358Computer · failedDUAL FMC FAILURE APPROX 25 MIN AFTER T/O. PERFORMED BITE IAW FIM 34-61-00-810-801. NO CURRENT FAULTS. NO HISTORY PAST 90 DAYS. IB CREW REPORTS NO FAULTS. OK FOR SERVICE. (K)SDR AMTA200700359Thermostat · leakingLT AND RT POINTERS NOT THE SAME (SPLIT), THE ENGINE IS THE BLEED SOURCE. LT 40 PSI RT 20 PSI. T/S IAW FIM 36-10-00-810-804 FOUND EXCESSIVE LEAKAGE OF 450 THERMOSTAT. REMOVED AND REPLACED 450 THERMOSTAT IAW AMM 36-11-05-4. OPS CHECK AND LEAK CHECK GOOD. (SDR AMTA200700356Sensor · unserviceableRT BLEED TRIPOFF LIGHT ILLUMINATED IN FLIGHT. WOULD NOT RESET WITH TRIP RESET BUTTON. REMOVED AND REPLACED PRECOOLER CONTROL VALVE SENSOR IAW MM 36-12-03-4. OPS CHECK NORMAL. OK FOR SERVICE. (K)SDR AMTA200700354Sensor · inoperativeRT WINDSHIELD OVERHEAT LIGHT ILLUMINATED DURING CLIMBOUT. T/S SYS FOUND SENSOR INOPERATIVE, SWITCHED TO NR 2 SENSOR, ALL SYS OPS CHECKED NORMAL IAW MM 30-41-00-810-812. (K)SDR AMTA200700353Control Unit · malfunctionedWINDOW HEAT OVERHEAT LIGHT. LIGHT ON-R FWD. PERFORMED FIM 30-41-00. SWAPPED RT FWD AND RT SIDE WINDOW HEAT CONTROL UNITS. TESTED ALL WINDOW HEAT UNITS IAW AMM 30-41-11-5. OPS NORMAL ALL WINDOWS ON FLIGHT DECK. (K)SDR AMTA200700352Display · malfunctionedISFD VIDEO SCREEN IS SPLIT IN THE VERTICAL, SHOWS RIGHT HALF OF NORMAL SCREEN TWICE, NO FIRM CODE FOUND. PERFORMED ISFD BITE TEST, SCREEN RETURNED TO NORMAL. PERFORMED ISFD BITE TEST AGAIN IAW AMM34-20-00-8. OPS CHECK GOOD. OK FOR SERVICE. (K)SDR AMTA200700342A/C Pack · malfunctionedRT BLEED TRIP OFF LIGHT ILLUMINATED RESET OPERATED NORMALLY WITH LT PACK PRESS 38 PSI AND RT PACK 18 PSI AFTER 1 MINUTE TRIPPED OFF AGAIN. PERFORMED RT ENG BLEED AIR CROSSOVER OPS TEST IAW MM 36-11-00. NO DEFECTS FOUND. (K)SDR AMTA200700339Unknown · warning messageRT PACK LIGHT ILLUMINATED ON CLIMB OUT, PACK LIGHT EXTINGUISHED AFTER RESETTING MASTER CAUTION. PERFORMED RT PACK ZONE/TEMP CONTROLLER BITE IAW FIM 21-62-00-810-801, FOUND FLT FAULT TCV. RESET FAULT, FAULT WOULD NOT VERIFY, RT PACK BITE TEST OK. INTERMITTENSDR AMTA200700338Unknown · warning messageDURING CLIMB OUT, RT PACK LIGHT ILLUMINATED MASTER CAUTION AND AIR COND LIGHT DID NOT ILLUMINATE. PERFORMED RT PACK TEMP/ZONE CONTROLLER BITE IAW FIM 21-62-00-810-801, FLT FAULT WOULD NOT VERIFY, REF 2100/117, AND PERFORMED MASTER CAUTION FIN 31-52-00-810-801SDR AMTA200700337Unknown · warning lightREJECTED T/O AT 90 KIAS FOR MASTER CAUTION/ WINDOW HEAT LIGHT. PERFORMED BITE TEST IAW AMM 30-41-00 SYSTEM CHECKS NORMAL, NO FAULTS. (K)SDR AMTA200700331Valve · unserviceableAPU FAILED TO LIGHT OFF ROTATION AND IGNITION. OK, NO FUEL FLOW. TROUBLESHOT SYSTEM IAW FIM 49-31-00-810-808. FOUND APU FUEL SHUTOFF VALVE WOULD NOT OPEN. REMOVED AND REPLACED VALVE IAW AMM 28-25-02-4. OPS CHECK GOOD. (K)SDR AMTA200700322Processor · unserviceableCENTER FUEL TANK QTY BLANKS INTERMITTENTLY. (K) REMOVED AND REPLACED FUEL QTY PROCESSOR UNIT, C/W OPS CHECK, OPS CHECK GOOD. NO FAULTS NOTED AT THIS TIME IAW AMM 28-41-81. (K)
Back to Boeing 737-83N