SDR ASAA2017012121277Cover · missingEMERGENCY LIGHT COVER AT 23C IS MISSING. ACFT GROUNDED. INSTALLED A NEW COVER.SDR ASAA2017012119631Insert · damagedAPU OIL MONITORING DATA SHOWS OIL CONSUMPTION TO BE TRENDING HIGHER THAN EXPECTED. ACFT GROUNDED. REMOVED THE APU FUEL CONTROL UNIT AND THE APU LUBE MODULE IAW AMM 49-31-11-000-801 AND 49-91-11-000-802. FOUND APU LUBE MODULE UPPER RT MOUNT INSERT DAMAGED. SDR ASAA2017012119539Anti-Ice Valve · failedNR 1 ENGINE COWL TAI LIGHT STAYING ON. ACFT GROUNDED. REMOVED AND REPLACED THE NR 1 ENGINE COWL TAI VALVE, REF B737-800 AMM 30-21-11-400-801. INSTALLATION TEST FAILED. PRSOV WILL NOT STAY OPEN, COWL VALVE OPEN LIGHT DOES NOT DIM, REMAINS BRIGHT. REQUIRED FURTSDR ASAA2017012119497Start Valve · failedDURING ENGINE START NR 2 "START VALVE OPEN" REMAINED ILLUMINATED. GROUNDED - YES. REPLACED NR 2 ENGINE START VALVE. REF AMM 80-11-03 FOR R&R. OPS CKS GOOD AT THIS TIME.SDR ASAA2017012119479Warning System · false activationAFTER ENGINE START NR 2 ENGINE GEN OFF BUS AND SOURCE OFF LIGHTS ILLUMINATED. GEN TRIPPED OFF AFTER BEING CONNECTED TO BUS. GROUNDED - YES. ACCOMPLISHED NR 2 GENERATOR CONTROL UNIT BITE PROCEDURE. FOUND IDG FAULT LIGHT ILLUMINATED. RESET FAULT LIGHT. RE-CONNECSDR ASAA2017012119478Unknown · malfunctionedNR 1 HF RADIO DOES NOT TUNE CORRECTLY. WE COULD NOT UNDERSTAND ATC ON EVERY FREQUENCY WE TRIED. THEY HAD A DIFFICULT TIME UNDERSTANDING US. NR 2 HF COMMUNICATIONS WERE NORMAL. GROUNDED - YES. RESET/CYCLED NR 1 HF C/B AND PERFORMED BITE OF NR 1 HF TRANSCEIVER RSDR ASAA2017012019630Regulator · failedDURING CLIMB FROM FL 360 TO 370 A DUCT PRESSURE SHOWED 23 PSI DIFFERENCE. LEFT DUCT 27 PSI, RIGHT DUCT 50 PSI. AT CRUISE FL 370 DUCT PRESSURE SHOWED 7 PSI DIFFERENCE, LEFT DUCT 35 PSI, RIGHT DUCT 42 PSI. ACFT GROUNDED. PRECOOLER CONTROL VALVE FAILED HEALTHSDR ASAA2017012019499Lens · missingRT FORWARD OVERWING EXIT DOOR EMERGENCY LIGHT LENS MISSING. GROUNDED - YES. REPLACED MISSING EMERG LIGHT LENS COVER PER AMM 33-51-01. OPS OK.SDR ASAA2017012019494Spinner · erodedENG NR 2 FRONT CONE. SPINNER BLACK ANODIZED COATING AND WHITE ANTI-EROSION PAINT IS MISSING. GROUNDED - YES. REMOVED AND REPLACED NR 2 FRONT CONE SPINNER REF AMM 72-21-01.SDR ASAA2017012019493Spinner · erodedENG NR 1 SPINNER FRONT CONE BLACK ANODIZED COATING AND WHITE ANTI-EROSION PAINT IS MISSING. GROUNDED - YES. REMOVED AND REPLACED ENG NR 1 SPINNER FRONT CONE REF AMM 72-21-01.SDR ASAA2017012019484B-Nut · looseLEFT BLEED TRIP OFF CAUTION ILLUMINATED. FOLLOWED BLEED TRIP QRH PROCEDURES AND RESET VIA TRIP RESET. LIGHT EXTINGUISHED AND OPS WERE NORMAL AFTERWARDS. GROUNDED - YES. PER FLIGHT CREW CONSULTATION LEFT DUCT PNEUMATIC PRESSURE INDICATED ZERO PSI. PERFORMED ALTSDR ASAA2017012019468Actuator · faultedON CLIMBOUT & AGAIN DURING CRUISE RECEIVED A MASTER CAUTION AIR COND ANNUNCIATION & THE ASSOCIATED RIGHT PACK LIGHT. PERFORMED QRH PROCEDURES & CONTINUED FLIGHT. ACFT GROUNDED. CONFIRMED FAULT, RIGHT PACK/ZONE TEMP CONTROLLER SHOWS NUMEROUS RT RAM AIR INLET ASDR ASAA2017012019467Actuator · faultedRT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. LIGHT GOES OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. REMOVED & REPLACED THE RT RAM AIR INLET ACTUATOR IAW AMM 21-51-21. ACCOMPLISHED BITE TEST RT PACK/ZONE TEMP CONTROLLER IAW AMM 21-61-00-700-806-0SDR ASAA2017011920779Skin · dentedDENT IN FUSELAGE AFT OF L2 DOOR CUTOUT APROXIMATELY TWO FEET AT SKIN SEAM. ACFT GROUNDED. ACCOMPLISHED A CATEGORY B REPAIR TO THE EXTERIOR SKIN BS 1002 - 1016 , STRINGERS 12 - 16L IAW SRM 53-70-01-2R-1, REPAIR 1.SDR ASAA2017011919475Control Valve · failedDURING CLIMB OUT, CONTROL CABN ZONE TEMP ILLUMINATED BUT EXTINGUISHED WITH MASTER CAUTION RESET. PERFORMED QRH ITEMS TO POINT WHETHER IT STATES, "NO FURTHER ACTION REQUIRED". ACFT GROUNDED. REPLACED THE CONTROL CABIN TRIM VALVE (V143) IAW AMM TASK 21-61-21-40SDR ASAA2017011919492Blade · chippedON PERFORMING T/C 78472002 FOUND NR 2 ENG BLADES POSITION 2,3,12,17,23,24 CU-NI COATING IN AREA Y CHIPPED. GROUNDED - YES. ON DEFERRAL.SDR ASAA2017011919491Seal · missingNR 2 ENGINE 24 PLATFORMS MISSING SEALS. GROUNDED - YES. REPLACED PLATFORMS (24EA) ON NR 2 ENG PER T/C 78472002.SDR ASAA2017011919488Seal · wornAPU SIGMA SEAL OUT OF LIMITS REF T/C 78349000. GROUNDED - YES. REMOVED AND REPLACED APU SIGMA SEAL REF AMM 49-15-11.SDR ASAA2017011919486Wire Harness · faultyAPU OPERATIONAL TEST FOLLOWING APU REPLACEMENT SHOWS CURRENT STATUS FAULT 49-41298, STARTER CONVERTER SHOWS GENERATOR PMG FAILURE. GROUNDED - YES. REMOVED AND REPLACED APU STARTER GENERATOR WIRE HARNESS REF AMM 49-11-01. OPS TEST GOOD. NO CURRENT FAULTS.SDR ASAA2017011919474Warning Light · false activationCONTROL CAB ZONE TEMP ON RECALL EXTINGUISHES ON MASTER CONTROL RESET. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMPERATURE CONT BITE TEST, FLT DECK TRIM VALVE FAULTED. RESET FAULT, SYSTEM OPS NORMAL IAW AMM 21-61-00-700-806-002. OK FOR SERVICE.SDR ASAA2017011919469Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. ACCOMPLISHED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801. FOUND FLT DECK TRIM VALVE FAULT LATCHED. RESET LATCH. OPS NORMAL.SDR ASAA2017011919466Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. NR 2 PACK/ZONE TEMP CONTROLLER LOGGED TCV FAULT. ACCOMPLISHED NR 2 CONTROLLER BITE IAW FIM 21-61 TASK 801, TEST PASSED. NO HISTORY PAST 30 DAYS.SDR ASAA2017011819442Battery Pack · inoperativeEMERGENCY LIGHTS FAILED FUNCTIONAL TEST. GROUNDED. REMOVED & REPLACED THE BATTERIES. OPS GOOD IAW AMM 33-51-06-960-805.SDR ASAA2017011819441Compensator · failedDURING ACCOMPLISHMENT OF N5-28FCD-18090-1 FQIS NR 2 TANK AND COMP UNITS TESTING, FOUND COMP UNIT F15 AND TANK UNITS F1, F3, F8, F9, AND F10 OUT OF LIMITS. GROUNDED. REMOVED AND REPLACED RIGHT MAIN TANK COMP PROBE AND TANK UNITS F1, F2, F3, F8, F10. IAW AMM 28-SDR ASAA2017011819440Compensator · failedDURING ACCOMPLISHMENT OF NG-28FCD-18088-1, FQIS NO 1 TANK AND COMP UNITS TESTING FOUND COMP UNIT F15 AND TANK UNITS F1,F2, F6, F7, F8, F9,& F10 OUT OF LIMITS. GROUNDED. REMOVED AND REPLACED TANK 1 COMP PROBE F15 AND F1,F2, F6, F7, F8, F9 AND F10 TANK UNITS IAWSDR ASAA2017011719465Engine · malfunctionedDURING ENGINE START OF THE NR 1 ENGINE. THE ENGINE N2 ROSE VERY SLOWLY AND HUNG AT 19% AT ABOUT 40 SECONDS INTO THE START. ACFT GROUNDED. PERFORMED FIM 80-05, TASK 806, ENGINE STARTED SLOW N2 ACCELERATION TO IDLE OR HUNG START WITH NO DEFECTS NOTED. VERIFSDR ASAA2017011719490Balance Weight · out of adjustNR 1 ENGINE TREND DATA SHOWS LOW PRESSURE ROTOR VIBRATION LEVELS TO BE TRENDING HIGHER THAN EXPECTED AFTER LAST FAN MAINTENANCE. GROUNDED - YES. ACCOMPLISHED AMM TASK 71-00-00-750-808-F00 TEST 14B. BALANCE WEIGHTS 24 P12 CHANGED TO P14, 28 P12 CHANGED TO P14, SDR ASAA2017011719428Terminal · defectiveTHE NR ENGINE B FIRE LOOP FAILED A TEST. ACFT GROUNDED. REMOVED AND REPLACED BOTH TOP LUG TERMINALS (FOUND ONE BAD AND THE OTHER ONE QUESTIONABLE) FOR THE RIGHT CORE FIRE DETECTOR IAW AMM 26-11-02. REMOVED AND REPLACED RIGHT CORE FIRE DETECTOR AS PRECAUTIONSDR ASAA2017011719429Warning Light · false activationFLIGHT CREW REPORTED THE NR 1 ENGINE COWL ANTI-ICE BLUE LIGHT STAYED ON AFTER ENGINE SHUT DOWN, WITH THE SWITCH TURNED OFF. ACFT GROUNDED. RAN THE NR 1 ENGINE AT IDLE, LIGHT WENT OUT IMMEDIATELY, ALL OTHER INDICATIONS ARE NORMAL. IAW FIM 30-21 TASK 801.SDR ASAA2017011719427Satcom · lockedSATCOM LOCKUP DURING POWER TRANSFER. GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM OPS RESTORED NORMAL.SDR ASAA2017011619412Indicator · unknownFOUND CENTER TANK REFUEL QUANTITY INDICATOR GOES INTO SELF TEST, THEN READS QUANTITY & BACK TO TEST. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT. TESTED CENTER REFUEL GAUGE IAW AMM 28-41-61. OPS NORMAL. NO FAULTS NOTED.SDR ASAA2017011619413Lens · missingLIGHT COVER IS MISSING. ACFT GROUNDED. REPLACED AFT LEFT LAV FLOOR PROXIMITY LIGHT LENS, IAW AMM 33-51-14. OK FOR SERVICE.SDR ASAA2017011519390Heat Exchanger · leakingON WALK AROUND FOUND NR 2 ENGINE MAIN OIL/FUEL HEAT EXCHANGER PAD DRAIN TO BE LEAKING, 65 DROPS PER MINUTE. (STATIC). ACFT GROUNDED. REMOVED AND REPLACED SERVO FUEL HEATER IAW AMM 73-11-07-000-801-F00 AND AMM 73-11-07-400-801-F00. LEAK CHECKED GOOD.SDR ASAA2017011519367Probe · out of toleranceACCOMPLISHED NG-28FCD-18090-1, NR 2 FQIS COMPENSTATOR & TANK UNITS TEST. THE FOLLOWING PROBES ARE OUT OF TOLERANCE AND REQUIRE REPLACEMENT. COMP, F1, F2, F3, F8, F9, AND F10. GROUNDED - YES. REF MIG 2C'S AND ASA T/C 78528000 FOR RII AND SAFETY PRECAUTIONS. REMSDR ASAA2017011519416Eec · faultedNR 2 ENGINE HAD SHORT TIME FAULT 75-30452 - THE VBV POSITION SIGNALS DISAGREE. ACFT GROUNDED. ACCOMPLISHED TROUBLESHOOTING IAW FIM 75-32 TASK 803. INITIAL EVALUATION AND FAULT ISOLATION FOUND NO DEFECTS. EEC TESTS INDICATED NO FAULTS. DUE TO EXTENSIVE HISTORSDR ASAA2017011519392Light · missingEXIT LIGHTING TRACK AT ROW 12DEF SIDE MISSING. GROUNDED - YES. INSTALLED NEW TRACK LT AT ROW 12DEF. OK FOR SERVICE.SDR ASAA2017011519381Valve · wornENG 1 HIGH STAGE VALVE WORN. GROUNDED - YES. REMOVED AND REPLACED HIGH STAGE VALVE. OPS CK GOOD AND NO LEAKS NOTED REF AMM 36-11-06.SDR ASAA2017011419391Warning System · false activationAPPROXIMATELY 1 MINUTE AFTER LANDING THE NR 1 ENGINE OIL FILTER BYPASS LIGHT ILLUMINATED (WITH POWER AT IDLE THRUST) ENGINE WAS THEN SHUTDOWN. GROUNDED - YES. ACCOMPLISHED FIM 79-05 TASK 817 UP TO E(2)(C)1). ACCOMPLISHED REPAIR CONFIRMATION PART POWER LEAK CHESDR ASAA2017011419388Probe · failedDIAGNOSTICS REPORTS NR 1 ENGINE TREND DATA SHOWS A SHIFT IN EGT HOT DAY MARGIN ALL OTHER PARAMETERS NORMAL. EGT INDICATION ERRORS ARE SUSPECT. GROUNDED - YES. ACCOMPLISHED T49.5 PROBE & EGT SYSTEM INSPECTION & CLEANING. T 49.5 S4 PROBE FAILED RESISTANCE CHECK.SDR ASAA2017011419387Actuator · leakingNR 1 ENGINE LT VSV ACTUATOR LEAKING (AT 6:00 DRAIN) (8 DROPS PER MINUTE). GROUNDED - YES. REMOVED AND REPLACED NR 1 ENG LT VSV ACTUATOR. NO LEAKS NOTED OPS CK GOOD. REF AMM 75-31-01.SDR ASAA2017011419378Battery Pack · dischargedWHILE ACCOMPLISHING TASK CARD 78233001 LIGHTS FROM SEAT ROW 25 AFT ON LEFT SIDE OF AIRCRAFT AND CENTER AFT GALLEY LIGHT FAILED 15 MIN CHECK AFTER DEEP CYCLE OF BATTERIES. GROUNDED - YES. REMOVED AND REPLACED BATTERY PACK AT POWER SUPPLY M1673 AND M1672 REF AMMSDR ASAA2017011419374Warning System · intermittentENGINE ANTI ICE WAS TURNED OFF DURING ENGINE SHUTDOWN. NR 1 COWL VALVE REMAINED OPEN WITH SWITCH IN OFF POSITION. GROUNDED - YES. ACCOMPLISHED FIM 30-21 TASK 804. INTERMITTENT FAULT. NR 1 ENG COWL ANTI ICE VALVE & SWITCH OPS CHECK GOOD. NO HISTORY 30 DAYS.SDR ASAA2017011419372Compensator · failedWHILE ACCOMPLISHING TASK CARD NG 28FCD-18088-1 ON THE NR 1 MAIN TANK, FOUND THE COMPENSATOR PROBE (66.69PF),TU 1(65.80PF), TU 3(41.92PF) TU 6(38.80PF), TU 8 (38.36PF), TU 9 (34.14PF) AND TU 10 (42.21PF) OUT OF LIMITS PER AMM 28-41-21-710-801. GROUNDED - YES. RSDR ASAA2017011419371Compensator · failedFUEL GAGES READ NORMAL AT TAKE OFF BUT CLIMBING THROUGH 5000' FUEL IMBALANCE LIGHT ILLUMINATED - LEFT MAIN TANK INITIALLY READ 1400 LB LOWER THAN THE RIGHT MAIN. THEN LATER ESTABLISHED AT 1000 LB DIFFERENCE. GROUNDED - YES. REF MIG-2C'S AND TASKCARD 78528000 FSDR ASAA2017011419370Warning System · false activation1+40 INTO THE FLIGHT THE NR 2 AFT MAIN FUEL BOOST PUMP LOW PRESSURE LIGHT CAME ON. RUN QRH TALKED WITH DISPATCH AND MX CONTROL AND CONTINUED. GROUNDED - YES. PERFORMED FIM TASK 28-22-00-810-805 NR 2 AFT BOOST PUMP OPS NORMAL NO HISTORY 30 DAYS OK FOR FLIGHT.SDR ASAA2017011419369Compensator · failedWHILE ACCOMPLISHING TASK CARD NG-28FCD-18090-1 ON THE NR 2 TANK, FOUND TU 4 (29.35PF), TU 5 (32.82PF), TU 6 (38.57PF), TU 8 (39.00PF) AND TU 9 (41.06PF) OUT OF LIMITS PER AMM 28-41-21-710-801. GROUNDED - YES. REMOVED AND REPLACED TANK UNITS F6R, F8R, F9R, F4R SDR ASAA2017011419366Satcom · lockedSATCOM LOCKUP GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM RESTORED NORMAL.SDR ASAA2017011419365Satcom · lockedSATCOM LOCKUP PRIOR TO PUSHBACK GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM RESTORED NORMAL.SDR ASAA2017011419357Warning System · activatedLEFT RAM DOOR FULL OPEN LIGHT ILLUMINATED AFTER LIFTOFF AND STAYED ON THRU OUT FLIGHT. GROUNDED - YES. RELEASED PER MEL 21-5C. COMPLIED WITH CONFIG CHANGE PER MEL. REVERSED SP PROC FOR MEL 21-5C & REACTIVATED RAM AIR MODULATING SYS PER AMM TASK 21-00-00-440-80SDR ASAA2017011419356Unknown · unknownENGINE START IN SJC NR 1 ENGINE N2 WAS VERY SLOW IN SPOOLING UP MAX ROTATION WAS 21.2 % AFTER APPROXIMATELY 35 SECONDS WITH START LEVER STILL IN CUTOFF. AFTER LEVER RAISED TO IDLE N2 AND N1 CONTINUED TO RISE SLOWLY BUT CONSISTENTLY ACHIEVING CUTOUT W/ NORMAL P
Back to Boeing 737-890