SDR ASAA2017011319868Probe · faultyPER TASK CARD 78273000 ECONOMIC FAULT FOUND MSG 73-31372 ON NR 2 ENGINE. GROUNDED - YES. INSPECTED AND FOUND S1 OUT OF LIMITS BY PERFORMING LINE RESISTANCE CHECK. S4 PROBE IS WITHIN LIMITS. RMVD AND INSTALLED NEW S1 T49.5 PROBE REF AMM TASK 77-21-01-400-801-F0SDR ASAA2017011319377Nut Plate · brokenLT FWD OVERWING EMERGENCY EXIT LIGHT LENS COVER HAS 2EA SPINNING FASTENERS. NUTPLATES ARE BROKEN. ACFT GROUNDED. REPAIRED IAW AMM 33-51-04-960-802 PARAGRAPH F(3) THROUGH (9). COMPLETED STEP F(10) THROUGH G(1). LIGHT OPS TEST GOOD, IAW AMM 33-61-04.SDR ASAA2017011319375Circuit Breaker · poppedAFTER ENGINE START CAPT PITOT LIGHT CAME ON AND FOUND CIRCUIT BREAKER POPPED. GROUNDED - YES. INSP C/B PANEL NO DEFECTS NOTED RESET C/B PITOT HEAT OPS CK OK PER AMM 30-31-00SDR ASAA2017011319368Compensator · failedPER T/C NG-28FCD-18088-1 FQIS-NR 1 TANK AND COMPENSATOR UNIT TESTING. FOUND F9 (TANK UNIT OUT OF LIMITS). GROUNDED - YES. REMOVED AND REPLACED F9 TANK UNIT REF AMM 28-41-21. FQIS SYSTEM TEST PASSED AND NO FAULTS REF AMM 28-41-00. FUEL ACCESS PANELS CHECK NO LESDR ASAA2017011319355Warning System · false activationLEFT RAM DOOR FULL OPEN LIGHT ILLUMINATED ENROUTE & THROUGHOUT CRUISE FLIGHT AT 370. GROUNDED - YES. PER FIM 21-51 TASK 803 CONDUCTED BITE TEST OF LEFT PACK SYSTEM. NO FAULTS DETECTED. CANNOT DUPLICATE DISCREPANCY ON GROUND. AIRCRAFT OK FOR SERVICE.SDR ASAA2017011319354Unknown · malfunctionedON STARTING ENGINE NR 2 IN LAS, ENG START INDICATIONS WERE VERY SLOW TO INCREASE. START PSI WAS BELOW 30 AND AT REACHING 20% N2, MOVED START LEVER TO RUN. ENGINE CONTINUED TO START BUT VERY SLOWLY. EXHAUST FUMES ENTERED AIRCRAFT DURING START. START COMPLETED WSDR ASAA2017011219417Baffle · crackedFWD CARGO BAY RT TRANSITION PANEL BAFFLE AND ANGLE BETWEEN BS 500G AND 500H ARE CRACKED. ACFT GROUNDED. REMOVED AND REPLACED BAFFLE AND ANGLE IAW SRM 51-40-02.SDR ASAA2017011219383Starter Gen · failedAPU GENERATOR NO FREQ OR VOLTS-GENERATOR FAILED. GROUNDED - YES. REMOVED AND REPLACED APU STARTER GENERATOR, REF AMM 49-41-21. OPS TEST GOOD, BITE TEST NO FAULTS FOUND. THIS CLEARS MEL 49-1B.SDR ASAA2017011219382Tube · brokenAFTER ENGINE START, THE LEFT DUCT PRESSURE INDICATES 7 PSI WITH ENGINE POWER AT IDLE, A/C PACKS IN AUTO AND ENGINE ANTI ICE OFF. GROUNDED - YES. FOUND MUSCLE AIR LINE TO NR 1 ENGINE HIGH STAGE VALVE BROKEN. REPLACED LINE AND LEAK CHECK OK. GROUND VERIFICATION SDR ASAA2017011219373Anti-Ice Valve · failedAFTER LANDING SWITCHING TO APU PWR THE NR 1 COWL VALVE / WING ANTI ICE VALVE CIRCUIT BREAKER POPPED. GROUNDED - YES. NO HISTORY PAST 90 DAYS, OPENED & GVI P18-3A6 C/B NO DEFECTS NOTED. GND IDLE NR 1 ENG OPS CHECKED NR 1 ENG ANTI-ICE ON GENERATOR & APU PWR, P18SDR ASAA2017011219364Unknown · malfunctionedSAT PROMPT DISAPPEARED WITH POWER TRANSFER. GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM RESTORED NORMAL.SDR ASAA2017011219363Satcom · malfunctioned"SAT" MISSING ON FMC GROUNDED - YES. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM RESTORED NORMAL.SDR ASAA2017011219353Door · damagedRT RAM AIR INLET ACTUATOR DEFLECTOR DOOR SPONGY. ACFT GROUNDED. PERFORMED BITE TEST AMM TASK 21-61-00-700-806-002, NO DEFECTS NOTED. DEFLECTOR DOOR OPS NORMAL AND SECURE IN DEPLOYED POSITION. OK FOR CONTINUED SERVICE.SDR ASAA2017011119323Warning System · false activationR2 WINDOW HEAT OVERHEAT LIGHT ILLUMINATED. PERFORMED QRH PROCEDURE. OVERHEAT LIGHT REMAINED ILLUMINATED. GROUNDED - YES. PERFORMED BIT PROCEDURE PER FIM 30-41 TASK 801. NO CURRENT FAULTS FOUND. OPS CHECK R2 WINDOW HEAT, OPS CHECK NORMAL. CANNOT DUPLICATE DISCRSDR ASAA2017011119319Control Valve · failedLEFT PACK LIGHT ILLUMINATES ON RECALL, WILL RESET WITH MASTER. GROUNDED - YES. REMOVED AND REPLACED LEFT PACK PRIMARY TEMP CONTROL VALVE REF AMM 21-51-10. PACK/ZONE TEMP CONTROLLER BITE TEST SATISFACTORY. REF AMM 12-61-00. LEAK CK. GOOD. CLEARS MEL 21-32B.SDR ASAA2017011119328Battery Pack · failedEMERGENCY LIGHTING SWITCH OPERATIONAL CHECK AND BATTERY PACKS - FUNCTIONAL CHECKS ILLUMINATED. ALL EMERGENCY LIGHTS FROM AND INCLUDING OVERWING EMERGENCY EXIT ROWS AFT INCLUDING AFT GALLEY FAILED 15 MINUTE CHECK. ACFT GROUNDED. REMOVED AND REPLACED THE BATTSDR ASAA2017011119326Fmc · malfunctionedLEFT FMC FAILED IN CRUISE FL 380, CHECKLIST FOLLOWED CONTINUED WITH SINGLE FMC OPS. ACFT GROUNDED. PULLED AND RESET THE NR 1 FMCS COMPUTER CIRCUIT BREAKER. TEST SUCCESSFUL IAW AMM 34-61-00-710-801. FMC OPS CHECKED NORMAL.SDR ASAA2017011119322Pump · failedTHE NR 1 AFT BOOST PUMP LIGHT ILLUMINATED WITH SWITCH ON. ACFT GROUNDED. FOUND THE CIRCUIT BREAKER CLOSED, BUT CFI OPEN WITH WHITE BAND SHOWING. RESET THE GFI, LIGHT EXTINGUISHED THEN REILLUMINATED. WHITE BAND IS SHOWING ON GFI. AFTER GFI RESET , LOW PRESSSDR ASAA2017011119321Satcom · lockedSATCOM LOCKUP. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURES IAW QRH. SATCOM OPS RESTORED NORMAL.SDR ASAA2017011019300Warning Message · false activationF/O MCDU LOCKED UP WITH FLASHING "BUTTON PUSH IGNORED" MESSAGE IN SCRATCH PAD. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT, F/O'S GROUND VERIFICATION TEST PASSED, IAW AMM 34-61-01.SDR ASAA2017010919291Connector · dirtyDURING COMPLETION OF T/C 78273000 FOUND MAINT MESSAGES #75-10452 AND #75-20452 "THE VBV POSITION SIGNALS DISAGREE" SHORT TIME FAULT, #2 ENGINE ESN 896-367. GROUNDED - YES. ACCOMPLISHED T/S FOR FAULT 75-10452 (AND 75-20452, REF LOGPAGE 11612951) PER B737-800 FISDR ASAA2017010919288Circuit Breaker · trippedFOUND AUTOTHROTTLE DC1 CIRCUIT BREAKER OPEN. ACFT GROUNDED. RESET THE C/B, IAW AMM 20-60-01 & WDM 22-31-31. PERFORMED OPERATIONAL CHECK OF AUTOTHROTTLES IAW AMM 22-31-00/501 & OPS TEST PASSED. C/B REMAINED CLOSED.SDR ASAA2017010919287Relay · failedAUTOPILOT NR 1 & 2 WOULD NOT ENGAGE. ACFT GROUNDED. PERFORMED DFCS BITE, IAW FIM 22-11 TASK 801, FOUND MAINTENANCE MESSAGE 22-11176. STAB TRIM RELAY ISSUE. REPLACED THE STAB TRIM RELAY R64, IAW FIM 22-13 TASK 818. ALL TESTED GOOD.SDR ASAA2017010819415Oil Cooler · contaminatedAPU HAS A HISTORY OF OIL SERVICING. CURRENT OIL CONSUMPTION IS HIGHER THAN EXPECTED. ACFT GROUNDED. REMOVED APU EGT THERMOCOUPLE 1,IAW AMM 49-71-21-000-801. INSPECTED APU TURBINE EXHAUST DUCT FOR EXCESSIVE OIL LEAKAGE WITH FLEXIBLE BORESCOPE IAW FIM 49-95-TSDR ASAA2017010819273Servo Motor · failedAUTOTHROTTLES INOPERATIVE, NOT ARMING. ACFT GROUNDED. VERIFIED FAULT IS STILL ACTIVE THROUGH A/T BITE. REPLACED THE NR 1 AUTOTHROTTLE SERVO MOTOR IAW AMM 22-31-91-020-801. OPS CHECKED GOOD.SDR ASAA2017010819275Controller · failedDURING CLIMB OUT AT FL250, LEFT SIDE WINDOW OVERHEAT ILLUMINATED. PERFORMED QRH. ACFT GROUNDED. REMOVED AND REPLACED WHCU M322 FOR LEFT SIDE WINDOW HEAT. OPS CHECKED GOOD IAW AMM 30-41-11.SDR ASAA2017010819274Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE PER QRH. SATCOM OPS RESTORED NORMAL.SDR ASAA2017010819272Computer · malfunctionedFCC-B FAILS BITE TEST NR 31. ACFT GROUNDED. ACCOMPLISHED FCC B LRU INTERFACE TEST IAW AMM 22-11-33/401, AND A DFCS LAND VERIFY TEST IAW AMM 22-11-00/201. BOTH TESTS PASSED. COMPLETED LIBRARY TEST 31 AILERON IA EXTENDED MAINTENANCE IAW BITE GROUP 60 IAW AMM 2SDR ASAA2017010719400Web · corrodedAFT CARGO BAY FLOOR WEB HAS CORROSION BETWEEN BS 787 AND 847, RBL 21-28. ACFT GROUNDED. REMOVED AND REPLACED THE WEB IAW DWG 146A8123 REV C AND SRM 51-40-02,SDR ASAA2017010719262Fmc · inoperativeLEFT FMC FAILED DURING CRUISE. ACCOMPLISHED QRH UNABLE TO RESTORE LT FMC. ACFT GROUNDED. VERIFIED FAULT. OPEN & CLOSED THE CIRCUIT BREAKER FOR LT FMC. LT FMC RETURNED TO NORMAL IAW FIM 34-61 TASK 836. OPS TEST PASSED IAW AMM 34-61-00-710801.SDR ASAA2017010719260Sign · detachedEXIT SIGN BY R1 DOOR DETACHED. ACFT GROUNDED. REMOVED, REPLACED, AND TESTED THE SIGN ASSY L1186 IAW AMM 33-51-01-960-802, OPS NORMAL.SDR ASAA2017010719254Circuit Breaker · brokenSPCU NORMAL CIRCUIT BREAKER ON SPCU BROKEN. ACFT GROUNDED. REMOVED AND REPLACED SPCU, INSTALLATION TEST OK, IAW AMM 24-34-11.SDR ASAA2017010619451Floor Support · corrodedCOCKPIT FLOOR PANEL FLANGE HAS CORROSION AT ENTERYWAY. ACFT GROUNDED. REPAIRED IAW EA 800-53EA-18322 REV 00.SDR ASAA2017010619420Channel · corrodedFWD PIT - RT TRANSITION PANEL HAS AREAS OF CORROSION FROM STA 500C TO STA 500I ( MARKED IN RED ). GROUNDED - YES. REMOVED CORROSION FROM STA 500L TO STA 500I IAW SRM 53-30-53-01. ORIG MAT .090 IAW SRM 53-00-53. MAT REMOVED .004, MATERIAL REMAINING .036. FOUNDSDR ASAA2017010619404Transition Panel · crackedAFT CARGO BAY RIGHT TRANSITION PANEL CRACKED BS 727G - 767, STRINGERS 25 - 26R. ACFT GROUNDED. REPAIRED THE TRANSITION PANEL IAW SRM 53-00-53-2R-5, DWG 146A7502 REV- ND, AND 140N4500 REV G.SDR ASAA2017010619399Transition Panel · corrodedAFT CARGO BAY LEFT TRANSITION PANEL UPPER SURFACE CORRODED BS 727 - 727G. ACFT GROUNDED. REPAIRED THE TRANSITION PANEL IAW SRM 53-00-53-2R-5 AND DWG 146A7502 REV-, AND 140N4500 REV G.SDR ASAA2017010619256Fire Loop · malfunctionedWITH LOOP SELECTORS IN, NR 2 ENGINE DOES NOT TEST ON FIRE SYSTEM CHECK. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT. IAW AMM 26-11-00, ACCOMPLISHED ENGINE FIRE DETECTION LOOP RESISTANCE SYSTEM TEST, ALL VALUES ARE WITHIN LIMITS. REINSTALLED ENGINE, AND APU FISDR ASAA2017010619252Transceiver · failedNR 1 HF SHOWS FAIL IN BOTH WINDOWS. ACFT GROUNDED. UNABLE TO CONFIRM ORIGINAL DISCREPANCY, FAIL DID NOT SHOW IN WINDOW. WHILE TRYING TO COMMUNICATE ON HF NR 1, FOUND TRANSMIT AND RECEIVE TO BE GARBLED AND UNABLE TO UNDERSTAND EACH WAY. REPLACED NR 1 HF TRANSCESDR ASAA2017010619259Compensator · no testDURING ACCOMPLISHMENT OF TASK CARD NG-28FCD-18088-1. FOUND A TOTAL SEVEN BAD FUEL PROBES, F15, F1, F2, F3, F7, F8 AND F10. ACFT GROUNDED. NR 1 TANK IS SUMPED AND NR 1 BUSSING PLUG IS DISCONNECTED. REPLACED THE NR 1 TANK COMPENSATOR F15 AND PROBES F1, F2, SDR ASAA2017010619258Probe · no testDURING ACCOMPLISHMENT OF TASK CARD NG-28FCD-18090-1. FUEL QTY INDICATION SYSTEM NR 2 TANK AND COMPENSATOR UNITS TESTING. FOUND SIX FUEL PROBES OUT OF TOLERANCE F1, F2, F3, F4, F6 AND F8. ACFT GROUNDED. 2 TANK IS SUMPED AND NR 2 BUSSING PLUG IS DISCONNECTESDR ASAA2017010619251Satcom · malfunctionedNO SATCOM IN MCDU. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2017010619250Satcom · lockedSATCOM LOCKUP. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2017010519397Floorboard · corrodedFWD PIT NR 1 FLOORBOARD 120AF IS CORRODED. GROUNDED - YES. FABRICATED NEW FLOOR PANEL IAW SRM 51 30 01 0G 0 AND 51 30 05 0G 0 W 2.5 O. 071 R 0 L 20 D .071.SDR ASAA2017010519269Valve · failedDURING CLIMBOUT, LEFT DUCT PRESSURE WAS AT 20PSI AND FLUCTUATED +15PSI. RIGHT DUCT PRESSURE WAS STEADY AT 45PSI. ONCE LEVEL AT FL 370, BOTH DUCT PRESSURE STABLE AT 40PSI. ACFT GROUNDED. REMOVED AND REPLACED THE NR 1 ENGINE PRE-COOLER CONTROL VALVE IAW ASDR ASAA2017010519265Fuel Heater · leakingNR 2 ENGINE FUEL HEATER SERVO LEAKING FUEL. ACFT GROUNDED. REMOVED AND REPLACED SERVO FUEL HEATER IAW AMM 73-11-07-000-801-F00 AND AMM 73-11-07-400-801-F00. OPS AND LEAK CHECKED GOOD, NO LEAKS NOTED.SDR ASAA2017010519257Probe · no testDURING ACCOMPLISHMENT OF NG-28FCD-18088-1, FQIS NR 1 TANK AND COMP UNITS TESTING, FOUND TU'S F4 AND F6 OUT OF LIMITS. ACFT GROUNDED. REMOVED AND REPLACED TANK 1 F4 AND F6 TANK UNIT PROBES IAW AMM 28-41-21-400-801. ACCOMPLISHED FQIS SYSTEM TEST IAW AMM 28-41SDR ASAA2017010519255Wire · brokenNR 1 ENGINE FIRE LOOP TEST FAILED FOR LOOP A. FAULT LIGHT AND NR 1 ENGINE FIRE LIGHT WOULD NOT ILLUMINATE DURING TEST. ACFT GROUNDED. DURING TROUBLESHOOTING FOUND A BROKEN WIRE OFF TERMINAL LUG AT M1760. REPLACED THE TERMINAL LUG IAW SWPM. LEFT ENG FIRE DSDR ASAA2017010519248Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED ON RECALL, RESET NORMALLY. ACFT GROUNDED. PACK/ZONE TEMPERATURE CONTROLLER BITE TEST DONE IAW AMM 21-61-00-700-806-002. NO FAULTS FOUND.SDR ASAA2017010419398Skin · crackedLEFT HORIZONAL STAB LOWER SKIN CARCKED AT HSS 111.1, 11 INCHES FROM T/E. ACFT GROUNDED. REPAIRED IAW SRM 55-10-01-2R-11 REP 11.SDR ASAA2017010419244Probe · failedAT PUSHBACK, FUEL TANKS READ LEFT 8.5, RIGHT 8.6, CENTER 25.9. DURING CRUISE, MAIN TANKS SLOWLY DECREASED TO LEFT 7.93, RIGHT 8.17 BY THE TIME THE CENTER TANK REACHED ZERO. OUTSIDE TEMP -64C. FUEL TEMP GOT TO -30C. ACFT GROUNDED. ACCOMPLISHED TASK CARDS NG-
Back to Boeing 737-890