SDR ASAA2016022615816Intercostal · crackedMAIN CABIN FLOOR FORWARD WET AREA, STABILIZATION INTERCOSTAL AT BL 0, BS 277-294 IS CRACKED. ACFT GROUNDED. R & R MAIN CABIN FLOOR FORWARD WET AREA STABILIZATION INTERCOSTAL AT BL 0, STA 277-294 IAW SRM 51-40-02 AND SRM 53-10-51-01-2, DWG 141A5400, REV A. RESDR ASAA2016022615716Skin · crackedLEFT HORIZONTAL LOWER SKIN IS CRACKED-INBD OF THE 6TH DRAIN HOLE. ACFT GROUNDED. ACCOMPLISHED HFEC TO VERIFY CRACK LOCATION REF NDT MANUAL 51-00-00, PART 6 PROCEDURE 23, LOCATED END OF CRACK LOCATION MEASURED APPROXIMATELY 1.5" IN LENGTH, CRACK IS CONFIRMED. SDR ASAA2016022615670Indication Sys · malfunctionedON A 1.5 HR FLIGHT, THE RT MAIN TANK SHOWED A 600 LBS LESS DIFFERENCE THAN THE LT MAIN TANK. THE FUEL USED SHOWED EVEN AND THE FUEL FLOW WAS THE SAME FOR EACH ENGINE. ACFT GROUNDED. PERFORMED FQIS BITE REF FIM 28-41, TASK 801, NO FAULTS FOUND, FQIS CHECKS GOSDR ASAA2016022515712Probe · failedTREND DATA SHOWS A INCREASE IN DELTA EGT AND DECREASE IN EGT HOT DAY MARGIN ON NR 2 ENGINE. ACFT GROUNDED. R & R NR 2 ENGINE T495S2 PROBE IAW AMM 77-21-01/401. NR 2 ENGINE ELECTRONIC ENGINE CONTROL BITE TESTED NORMAL WITHOUT FAULTS. T49.5 PROBE'S INPUT READSDR ASAA2016022515674Probe · failedNR 1 ENGINE ELECTRONIC ENGINE CONTROL BITE SHOWS FAULT CODE 77-20871, THE TOP LT EGT SIGNAL, T495S4 IS OUT OF RANGE. FAULT IS A LONG TERM FAULT AND IS LOGGED FOR 6 OUT OF THE LAST 10 STARTS. ACFT GROUNDED. ACCOMPLISHED T/S FOR FAULT 77-20871 IAW FIM 77-21, SDR ASAA2016022515672Display · malfunctionedCDU NR 2 FLASHING NOT ALLOWED, NO BUTTONS PRESSED CAUSE A RESPONSE. ACFT GROUNDED. RESET POWER FOR NR 2 CDU, OPS CHECK NORMAL. REF FIM 34-61, TASK 804.SDR ASAA2016022515668Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURES IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016022515667Satcom · lockedSATCOM LOCK-UP. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURES IAW QRH. SATCOM OPS NORMAL.SDR ASAA2016022515663Warning Light · false activationRT AIR CONDITION PACK LIGHT ON. GOES OUT WHEN MASTER CAUTION RESET. NO MASTER CAUTION WITH PACK LIGHT. ACFT GROUNDED. ACCOMPLISHED PACK CONTROLLER BITE TEST IAW AMM 21-61-00. FOUND NR 2 TCV FAULT. RESET FAULT AND RE-RAN BITE TEST WITH NO FAULTS PRESENT.SDR ASAA2016022415813Web · corrodedL2 DOOR SURROUND LOWER AUXILIARY SILL WEB IS CORRODED AT APPROXIMATELY BS 990, AT GROUND BLOCK LOCATION. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-70-15-1A-1, ORIGINAL MATERIAL THICKNESS IS 0.040", REMOVED
0.006 ", REMAISDR ASAA2016022415689Baffle · crackedFWD CARGO COMPARTMENT BAFFLE ASSY BETWEEN BS 500D AND 500E, LBL 21.0 IS CRACKED. ACFT GROUNDED. R & R CRACKED BUFFLE BETWEEN BS 500D-BS 500E IAW SRM 51-40-02, 51-40-05 AND BAC 143A7510. REV B.SDR ASAA2016022415656Plate · out of positionPLATE COVERS ALTITUDE INTERVENTION BUTTON. ACFT GROUNDED. R & R MCP REF AMM 22-1-34, OPS CHECK NORMAL. ACCOMPLISHED MCP LWMP CHECKS REF LWMP CHECKLIST AMM 22-00-01, ALL TEST PASSED.SDR ASAA2016022415661Shutoff Valve · failedON TAXI OUT, LT DUCT PRESSURE INDICATED ZERO. ACFT GROUNDED. REPLACED PRSOV REF AMM 36-11-04-400-801. REPLACED 450 THERMOSTAT REF AMM 36-11-05-400-801. NO HELP. REPLACED BLEED AIR REGULATOR, REF AMM 36-11-03-400-801. OPS CHECK NORMAL. GROUND VERIFICATION SSDR ASAA2016022415660Warning Message · false activationRECEIVED SEVERAL SCRATCHPAD MESSAGES "SINGLE FMC OPERATION" AFTER SHUTDOWN. ACFT GROUNDED. CONFIRMED EXISTENCE OF "SINGLE FMC OPS" MESSAGES IN MCDU'S. REMOVED & RESET EXTERNAL POWER TO ACFT AND PERFORMED BITE TEST OF FMC'S IAW AMM 34-61, TASK 801. OPS NORMAL,SDR ASAA2016022415659Keyboard · failedF/O FMC INPUT PANEL BUTTONS ARE INTERMITTENT. L-6 AND CLEAR BUTTONS. ACFT GROUNDED. VERIFIED, REF AMM 34-61-01. R & R F/O'S FMC MCDU KEYBOARD. OPS NORMAL.SDR ASAA2016022415658Connector · looseR1 DOOR EMERGENCY EXIT SIGN AND R1 ESCAPE SLIDE EMERGENCY LIGHT INOPERATIVE. ACFT GROUNDED. RE-SEATED CONNECTOR D10748 ON EMERGENCY LIGHT BATTERY PACK, M1674. ALL AFFECTED EMERGENCY LIGHTS, OPS NORMAL, REF WDM 33-51-12.SDR ASAA2016022415657Terminal · looseB LOOP ON RT CORE DETECTOR HAS LOOSE TERMINAL, ALMOST BROKE, UPPER RT. ACFT GROUNDED. REPAIRED DETECTOR TERMINAL LUG. OPS NORMAL, REF AMM 26-11-02.SDR ASAA2016022315827Web · crackedWHILE ACCOMPLISHING STRUCTURE, OPEN UP FOR BS986.5 FLOORBEAM REPAIR: FOUND SHEAR WEB AT BS 986 TO 1016, RBL 45-60, CORRODED AND CRACKED. ACFT GROUNDED. R & R RT G4 GALLEY SUPPORT WEB IAW SRM 51-10-02, PARA 9, 51-40-02, AND BAC DWG 147A5700, REV B. NO CORROSDR ASAA2016022315705Door Frame · corrodedAFT CARGO COMPARTMENT CARGO DOOR SURROUND LOWER SILL WEB IS CORRODED. ACFT GROUNDED. ACCOMPLISHED BLENDOUT OF CORRODED AREA AT AFT CARGO COMPARTMENT CARGO DOOR SURROUND LOWER SILL WEB IAW SRM 51-10-02. ORIGINAL MATERIAL: .056", REMAINING MATERIAL: .035", MASDR ASAA2016022315684Skin · dentedE AND E DOOR EXTERIOR SKIN HAS SMALL DENT. ACFT GROUNDED. DENT FOUND TO BE OUT OF LIMITS. REPAIRED DENTED AREA REF SRM 52-00-012, R2, REPAIR 2. EXTERIOR SURFACE MARKINGS WILL BE ACCOMPLISHED ON JC G650557.SDR ASAA2016022315643Control Unit · failedNR 1 ENGINE WOULD NOT START. ACFT GROUNDED. NO IGNITOR WAS HEARD DURING TEST REF AMM 74-00-00-750-801-F00. R & R NR 1 ENGINE LT AND RT INGITOR BOXES, DURING OPS TEST RT IGNITOR FAILED CHANNEL B TEST. R & R NR 1 ENGINE ELECTRONIC ENGINE CONTROL REF AMM 73-2SDR ASAA2016022315642Switch · failedAPU WILL NOT SHUTOFF WITH APU SWITCH IN OFF. ACFT GROUNDED. INTERMITTENT APU SWITCH, VERIFIED ON APU BITE, INPUT MONITORING PAGE 2/4. APU ON SWITCH AND APU OFF SWITCH BOTH SHOWS, NO, FOR UP TO A MINUTE BEFORE YES SHOWED ON APU OFF SWITCH INPUT. R & R S248 ASDR ASAA2016022315640Lens · missingEXIT ROW LIGHT COVER IS MISSING NEAR FLOOR ROW 17A. ACFT GROUNDED. INSTALLED NEW EXIT LENS COVER.SDR ASAA2016022215662Duct · looseNR 1, ENGINE LT UPPER 5TH STAGE BLEED AIR DUCT ATTACH BRACKET BEARING LOOSE/WORN. ACFT GROUNDED. REPLACED NR 1 ENGINE BLEED AIR DUCT IAW PPBU 71-00-02, FIG 16-1, NO LEAKS NOTED AFTER PNEUMATIC LEAK CHECK.SDR ASAA2016022215630Warning Message · false activationNR 1 ENGINE, SN 894851, SHOWS ECONOMIC FAULT CODE 73-31371, UPPER EGT SECTORS READ HIGH. ACFT GROUNDED. INTERROGATED THE FMC CDU FOR ENGINE FAULTS, BOTH ENGINES OPS NORMAL. NO RECENT FAULTS OR FAULT HISTORY FOUND.SDR ASAA2016022215629Servo · leakingNR 1 ENGINE FUEL HEAT SERVO LEAKING AT UPPER CAP SEAL PLATE AT INBD SIDE. ACFT GROUNDED. R & R NR 1 ENGINE FUEL HEAT SERVO IAW AMM 73-11-07-000-801-F00 AND 73-11-07-400-801-F00, NO POST-RUN LEAKS NOTED.SDR ASAA2016022215628Transmitter · leakingNR 1 ENGINE FUEL FLOW TRANSMITTER LEAKING AT LOWER ALLEN SCREW. ACFT GROUNDED. R & R NR 1 ENGINE FUEL FLOW TRANSMITTER ASSY REF AMM 73-31-01-000-801-F00. RAN ENGINE, NO LEAKS NOTED.SDR ASAA2016022215626Satcom · malfunctionedON CLIMBOUT OF OGG NOTED NO, SATCOM, PROMPT IN MCDU. ACFT GROUNDED. ACCOMPLISHED SATCOM RESET PROCEDURES IAW QRH. ALL OPS NORMAL.SDR ASAA2016022214927Fuel Nozzle · unknownENGINEERING REQUESTS REPLACEMENT OF THE NR 1 ENGINE LPT 11 FUEL NOZZLES DUE TO REPORTS OF HARD STARTING WHEN ENGINE IS COLD. ACFT GROUNDED. ACCOMPLISHED REPLACEMENT OF 11 FUEL NOZZLES IAW T/C POWERPLANT- 73CMPT-07267-2, START OF ENGINE, NORMAL.SDR ASAA2016022115692Web · gougedLOWER FUSELAGE ELECTRONIC EQUIPMENT COMPARTMENT DOOR CUTOUT, RT INTERCOSTAL WEB UPPER EDGE IS GOUGED. ACFT GROUNDED. R & R WEB, PN 141A8512-28, REF SRM 51-40-02, BAC DWG 141A8511. OPS CHECK GOOD. REMOVED DOT.SDR ASAA2016022115606Valve · failedAFTER START, GOT AIR COND LIGHT WITH MASTER CAUTION RECALL. ZONE TEMP CONTROLLER CAB LIGHT, RAN QRH. LIGHT DOES GO OUT WITH RESET AND TEMP IS CONTROLLABLE. ACFT GROUNDED. R & R LT ZONE TRIM AIR MODULATING VALVE IAW AMM 21-61-21. BITE TEST NORMAL.SDR ASAA2016022115609Exciter · failedON GROUND TRIED TO START APU, WOULD NOT START W/ FAULT LIGHT ILLUMINATED. AFTER 5 MINUTES FAULT LIGHT EXTINGUISHED. ACFT GROUNDED. R & R APU IGNITION UNIT REF AMM 49-41-31, R & R APU IGNITION LEAD REF AMM 49-41-52. OPS CHECK NORMAL, APU STARTS NO CURRENT SDR ASAA2016022115615Probe · failedWHILE ACCOMPLISHING TC 78273000, NR 1 ENGINE RECENT FAULTS, FAULT HISTORY DISPLAY FAULT 73-31371, UPPER EGT SECTORS READING HIGH. FLT LEGS 2,4 AND 10, FAULT IS ECONOMIC. ACFT GROUNDED. ACCOMPLISHED FIM 73-11, TASK 801, STEP E5 C1. S4, 125 DEGREES LOWER THANSDR ASAA2016022115607Lamp · failedL2 DOOR EMERGENCY LIGHT INOPERATIVE, EXTERIOR. ACFT GROUNDED. RE-LAMPED L2 DOOR EMERGENCY LIGHT REF AMM 33-51-04. OPS CKS GOOD.SDR ASAA2016022115604Warning Light · false activationON RECALL THE CONTROLLER CAB ZONE TEMP LIGHT ILLUMINATES. IT EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. VERIFIED CONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER RECALL, EXTINGUISHING WITH MASTER RESET. PERFORMED PACK/ZONE TEMP CONTROL BITE TESDR ASAA2016022015593Engine · faultedWHILE ACCOMPLISHING TASK CARD 78273000, ENGINE 2 LOGGED ECONOMIC FAULT 73-31372, UPPER EGT SENSORS READING HIGH. ACFT GROUNDED. ACCOMPLISHED FAULT ISOLATION IAW FIM 73-11, TASK 801. RAN ENGINE NR 2 AT IDLE FOR 5 MIN, ALL T49.5 PARAMETERS WERE IN RANGE, DIDSDR ASAA2016022015579Control Valve · malfunctionedPACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL. EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ZONE TEMP CONTROLLER BITE TEST FAULTED THE LT PACK TEMP CONTROL VALVE AND WOULD NOT RESET. R & R THE LT PACK TCV IAW AMM 21-51-21. ZONE TEMP CONTROLLER BSDR ASAA2016022015613Buss · failedF/A REPORTS ENTIRE REAR GALLEY WITHOUT POWER CHECKED BOTH COCKPIT CAB/UTL AND FE/FDSS SEAT SWITCHES ARE ON. ACFT GROUNDED. PERFORMED BUS POWER CONTROL UNIT BITE IAW FIM 24-41, TASK 801. NO FAULTS NOTED. DURING BPCU BITE, FOUND NR 4 GALLEY POWER WOULD OPERATSDR ASAA2016022015595Hmu · failedSHORTLY BEFORE TAKEOFF, NR 1 ENGINE CONTROL LIGHT COME ON. ACFT GROUNDED. PERFORMED ELECTRONIC ENGINE CONTROL BITE REF 73-00, TASK 801 FOUND FAULT CODE 75-10581. REF FIM 75-23, TASK 801. PERFORMED TEST 12 ACTUATORS TEST. TEST PASSED: NO FAULTS, FAULT IS INTESDR ASAA2016022015589Warning Message · false activationFMC DISAGREE ON GROUND. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. FMCS RESTORED NORMAL.SDR ASAA2016022015588Lens · damagedLIGHT COVER ADJACENT TO R2 DOOR HAS FALLEN OFF. ACFT GROUNDED. FOUND LT COVER ATTACHMENT POINTS DAMAGED. REPLACED DAMAGED R2 EMERGENCY EXIT LIGHT COVER REF AMM 33-51-01.SDR ASAA2016022015587Control Unit · malfunctionedWHEN BLOCKING INTO GATE, SHUTDOWN ENGINE NR 2. COOLING FAN WARNING HORN SOUNDED ALONG WITH LOSS OF RT FMC CDU AND OTHER INSTRUMENTATION. EXTERNAL POWER GROUND POWER AND APU WOULD NOT CONNECT TO AIRPLANE. AFTER WE SHUTDOWN NR 1, WERE ABLE TO CONNECT EXTERNALSDR ASAA2016022015586Battery · dischargedELECTRIC LIGHT ILLUMINATED DURING PREFLIGHT. ACFT GROUNDED. PERFORMED FIM 24-31, TASK 801. BITE TEST SHOWED BATTERY CHARGER INOPERATIVE. ACCESSED BOTH BATTERY CHARGERS & VERIFIED 2 GREEN LIGHTS ON BOTH CHARGERS. CLEARED FAULTS , RETESTED & NO FAULTS FOUNDSDR ASAA2016022015585Tru · trippedT/R UNIT AND NO AMPS ON T/R 2 AFTER SHUTTING DOWN NR 2 ENGINE ON TAXI IN. ONCE AT GATE, WENT TO GROUND POWER AND GROUND SERVICE BUS TO GET RID OF EQUIPMENT COOLING HORN. ACFT GROUNDED. FOUND C/B, FAN PWR NORMAL AND TRU2 ON P92 PANEL POPPED. INSPECTED AREA &SDR ASAA2016022015577Warning Light · false activationAUTO FAIL LIGHT ILLUMINATED ON PRESSURIZATION PANEL. ACFT GROUNDED. ACCOMPLISHED FIM 21-31, TASK 827 AUTO FAIL LIGHT ON. NR 2 CPC FAULTED ON GROUND, CABIN PRESSURE CONTROL MODULE NR 1 NO FAULTS. SWITCHED TO MANUAL THEN BACK TO AUTO, FAIL LIGHT EXTINGUISHEDSDR ASAA2016021915715Channel · corrodedAFT CARGO COMPARTMENT LT TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM BS 727D TO BS 807. ACFT GROUNDED. REMOVED CORROSION FROM AFT CARGO COMPARTMENT LT TRANSITION PANEL FROM BS 7270 TO BS 807 IAW SRM 51-10-02. ORIGINAL MATERIAL THICKNESS 0.040. MATESDR ASAA2016021915704Channel · corrodedFWD CARGO COMPARTMENT LT TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM BS 500D TO BS 500I. ACFT GROUNDED. REMOVED CORROSION IN FWD CARGO COMPARTMENT LEFT TRANSITION PANEL FROM BS 500D+10-500I IAW SRM 53-00-53 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53SDR ASAA2016021915687Channel · corrodedAFT CARGO COMPARTMENT RT TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM BS 727D TO BS 767. ACFT GROUNDED. REMOVED CORROSION FROM BS 727D-727H+10. ORIGINAL THICKNESS WAS .040, LOST .002, REMAINING .038 FOUND TO BE IN LIMITS IAW SRM 53-00-53-1A-2 ALODISDR ASAA2016021915686Channel · corrodedFWD CARGO COMPARTMENT RT TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM BS 500B TO BS 500I. ACFT GROUNDED. REMOVED CORROSION FROM BS 500B-500D IAW SRM 53-00-53. ORIGINAL MATERIAL THICKNESS .040, MATERIAL REMOVED .002, AND REMAING .038, FOUND TO BE WITHSDR ASAA2016021915611Warning Light · false activationNR 2 ENGINE CONTROL IT ILLUMINATED DURING TAXI. ACFT GROUNDED. PERFORMED FIM 73-06 TASK 801, ELECTRONIC ENGINE CONTROL BITE REF FIM 73-00, TASK 801 SHOWS TBV DEMAND AND SIGNAL DISAGREE. PERFORMED ACTUATOR TEST IAW AMM 71-00-00-700-807-F00. MAINTENANCE MESSAG