Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2014052107897Warning Light · false activationAPU FAULT LIGHT CAME ON. NO APU ROTATION SHUTDOWN, ACFT GROUNDED. PERFORMED GROUND VERIFICATION IAW FIM TASK 49-40, TASK 803. NO DEFECT NOTED. APU STARTS NORMAL. NO HISTORY 30 DAYS. FIM TASK 49-40TASK 803. PASSED CSS NO APU CAUTION LIGHTS PERFORMED AT FSDR ASAA2014052107890Control Valve · malfunctionedLEFT PACK LIGHT ON RECALL EXTINGUISHES WITH MASTER CAUTION. ACFT GROUNDED. REPLACED LT TEMP CONTROL VALVE. OPS CHECKED NORMAL, NO LEAKS NOTED, IAW MM 21-51-10.SDR ASAA2014052107896Display · malfunctionedLEFT MCDU BLANKED TWICE IN FLT AT FL340. MCDU RECOVERED WITHIN 2-5 SEC BOTH TIMES. DURING BOTH RECOVERIES MULTICOLORED BITE SCREEN APPEARED BEFORE RECOVERY. BOTH MCDU BLANKING INCIDENTS WERE DURING LEVEL CRUISE FLT WITH NO BUTTON PUSHES OR WAY POINT SEQUENCISDR ASAA2014052107894Satcom · malfunctionedNO SATCOM AVAILABLE ON MCDU MENU PAGE, IN FLIGHT. ACFT GROUNDED. PERFORMED FIM TASK 23-15-801. CIRCUIT BREAKER CYCLED. SATCOM RESTARTED.SDR ASAA2014052107891Warning Light · false activationLEFT PACK LIGHT CAME ON, LEFT PACK SHOWED 50 DEGREE C. RESET, AND ONE MINUTE LATER THE LIGHT CAME ON. RESET A SECOND TIME, AFTER 10 MINUTES, OPS NORMAL. ACFT GROUNDED. ACCOMPLISHED FIM TASK 21-53 TASK 813. NO DEFECTS NOTED. GROUND VERIFICATION COMPLETE. SDR ASAA2014052007882Satcom · malfunctionedUNABLE TO ESTABLISH CONTACT ON SATCOM 1 OR 2, CALLING PARTY ANSWERS BUT UNABLE TO HEAR US. ACFT GROUNDED. GROUND VERIFICATION PASSES ON BOTH SAT 1 & SAT 2 WAS ABLE TO ESTABLISH CONTACT WITH DISPATCH, ON SAT 1 & 2. ACCOMP. SAT COMM. VOICE TEST OUT GOING CALLSSDR ASAA2014051907868Wire · unknownELECTRIC LIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. PERFORMED LIGHT BITE IAW FIM 24-31 TASK 801, FOUND SPCU INOPERATIVE MESSAGE. PERFORMED FIM 24-34, TASK 802, FAULT CLEARED BITE CHECK PASSED, NO FAULTS. REPLACED TWO WIRE SEGMENTS, SEVEN GROUND WISDR ASAA2014051907865Shaft · damagedRIGHT SIDE INBD LINK ON RAM AIR INLET DOOR DEFLECTOR SHAFT ASSY IS DAMAGED. LT SIDE INBD LINK ON RAM AIR INLET DEFLECTOR DOOR SHAFT IS DAMAGED AND APPEARS TO BE CORRODED. ACFT GROUNDED. REPLACED RT RAM AIR INLET DEFLECTOR DOOR SHAFT ASSY AND LINKS REF AMM 2SDR ASAA2014051907867Warning Message · false activationPRESSURIZATION AUTO FAIL AND ALTERNATE LIGHTS ON. ACFT GROUNDED. CYCLED SWITCH TO MAN AND BACK TO AUTO. LIGHTS EXTINGUISHED. PRESSURE CONTROLLERS BITE NORMAL IAW FIM 21-31 TASK 801. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2014051807841Controller · unknownAUTO FAIL FL370, SYSTEM SWITCHED TO ALTN AUTOMATICALLY IAW CHECKLIST. SELECTED ALTN, AUTO FAIL EXTINGUISHED. SYSTEM OPERATED NORMALLY IN ALTN. ACFT GROUNDED. COMPLISHED BITE CHECK OF NR 1 CPC. NO LOGGED FAULTS. R & R NR 1 CPC IAW AMM 21-31-01. ACCOMPLISHEDSDR ASAA2014051707864Control Panel · failedBANK SELECTOR KNOB, MODE CONTROL PANEL 25 & 30 ONLY. ACFT GROUNDED. REPLACED MCP IAW MM 22-11-34, OPS CHECKED NORMAL. ACCOMPLISHED DFCS LRU MCP NR 32 TEST, LAND VERIFY NR 49, & HGS FCC/AT SENSOR TEST, ALL TEST NORMAL IAW MM 22-11-34, 22-11-00, & SMM:34-36-SDR ASAA2014051607826Modulating Valve · failedAFTER START, DURING RECALL THE AIR CONDITION LIGHT ILLUMINATED ASSOCIATED WITH ZONE TEMP LIGHT CONTROL CABIN. PERFORMED QRH. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. R & R CONTROL CABIN TRIM AIR MODULATING VALVE ASSY, OPS BITES GOOD IAW SDR ASAA2014051507833Wire Harness · damagedWHILE PERFORMING T/C 78273000, FOUND NR 2 ENGINE FAULT 73-31372 UPPER EGT SECTORS READING HIGH. ACFT GROUNDED. ACCOMPLISHED FIM TASK 73-11-801. ALL PARAMETERS PRESENT AND IN RANGE. APPLICABLE SEGMENTS SHOW VARIATION OF 2 DEGREES. CHECK OF RECENT FAULTS AND FSDR ASAA2014051507830Pcu · failedLEFT SIDE MASTER CAUTION GLARESHIELD ELETRIC DOES NOT ILLUMINATE. ACFT GROUNDED. REPLACED THE P5-5 GEN DRIVE AND STDBY PWR MODULE REF TASK 24-21-52-000-801. STDBY PWR SYS OPS TEST NORMAL REF TASK 24-34-00-710-802. ACCOMPLISHED OPS TEST FOR NR 1 IDG REF MSDR ASAA2014051507828Satcom · malfunctionedSATCOM LOCKED OUT, ACFT GROUNDED. QRH PROCEDURE ACCOMPLISHED TO RESTORE SATCOM.SDR ASAA2014051507827Circuit Breaker · trippedCIRCUIT BREAKER TRIPPED - P6-2 A3, ACFT GROUNDED. PERFORMED CIRCUIT BREAKER RESET PROCEDURE IAW AMM 20-60-01. CIRCUIT BREAKER REMAINS SET. PERFORMED IFSAU OPS CHECK IAW AMM 22-11-37. BITE AND OPS TEST PASSES. ACFT OK FOR SERVICE.SDR ASAA2014051507825Controller · malfunctionedAMBER "ZONE TEMP" FOR CONTROL CABIN COMES ON WITH RECALL, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. TESTED PACK/ZONE TEMP CONTROLLER IAW AMM 21-61-00-700-806-002. NO HARD FAULTS AND NO MAINTENANCE HISTORY WITHIN PAST 30 DAYS.SDR ASAA2014051407810Unknown · unknownPRACTICE HGS A111 AUTOLAND UNSATISFACTORY, FINAL 100' SINK RATE INCREASED WITH DECREASED PITCH RESULTING IN FIRM TOUCHDOWN. TD POINT WAS ACCURATE. NO HGS WARNINGS, BUT SINK RATE NOT STABLE AT LOW ALTITUDE. ACFT GROUNDED. PERFORMED A LAND VERIFY TEST IAW MMSDR ASAA2014051407809Regulator · malfunctionedCOCKPIT CABIN TEMP CONTROLLER WOULD NOT PROVIDE WARM AIR IN FULL WARM POSITION. COCKPIT REMAINED VERY COLD THROUGHOUT FLIGHT. ACFT GROUNDED. ACCOMPLISHED BITE CHECK OF BOTH PACK/ZONE TEMP CONTROLLERS. BOTH PASS AIRFLOW ACROSS CONTROL CABIN TEMP SENSOR OK. SDR ASAA2014051407813Warning Message · false activationFMC DISAGREE MESSAGE ON SCATCH PAD. ACFT GROUNDED. PERFORMED FIM 34-61, TASK 835. FMC DISAGREE MESSAGE REMOVED. TWO CIRCUIT BREAKERS OPENED, RESET FOR FIM P18-2 A6 & P6-1 D16. OPENED, RESET P6-1 D16 IAW FIM 34-61, TASK 835, OPS NORMAL. ETOPS GROUND VERIFICATSDR ASAA2014051407812O-Ring · leakingLIQUID DRIPPING UNDERNEATH RT ENGINE. ACFT GROUNDED. FOUND HYD FLUID FROM NR 2 ENGINE EDP CASE DRAIN. R & R EDP FILTER AND TEFLON RINGS IAW AMM 29-11-51-400-801. RAN ENGINE LEAK CHECK GOOD.SDR ASAA2014051407811Satcom · malfunctionedSATCOMM PROMPT NOT DISPLAYED ON MCDU MENU PAGE. ACFT GROUNDED. FOLLOWED SATCOMM LOCK-UP, ON GROUND, PROCEDURE FROM QRH 5.3. SATCOMM PROMPT RETURNED.SDR ASAA2014051307801Acars · malfunctionedACARS DATALINK IS FULL AND IT IS VERY SLOW IN ITS COMMUNICATION FUNCTIONS. ACFT GROUNDED. PERFORMED FIM TASK 34-61-00-810-839. RESET DATA LINK. DATA FULL MESSAGE DO NOT SHOW ON EITHER DIPLAY AFTER 5 MIN INITIAL DISCREPANCY INTERMITTENT FAULT IAW FIM TASK.SDR ASAA2014051307798Module · malfunctionedELECTRIC LIGHT ON, STATIC INVERTER INOPERATIVE. ACFT GROUNDED. REMOVED STATIC INVERTER REF MM:24-34-21. INSTALLED STATIC INVERTER REF MM 24-34-21-400-801. FAILS OPS CK. FAULT INDUCED W/ RCCB C/B OPEN TO CK STATIC INVERTER POWER LEADS TORQUE. STATIC INVERSDR ASAA2014051307795Satcom · malfunctionedSATCOM PROMPT MISSING AFTER POWER TRANSFER. ACFT GROUNDED. QRH PROCEDURE ACCOMPLISHED SATCOM OK.SDR ASAA2014051307794Satcom · malfunctionedSATCOM INOPERATIVE. ACFT GROUNDED. ACCOMPLISHED QRH. OPS NORMAL.SDR ASAA2014051207947Channel · corrodedAFT PIT, RT TRANSITION PANEL CORRODED AT FASTENER HOLES INCLUDING HOLES UNDER SIDEWALL PANELS, FS 272-792. ACFT GROUNDED. REMOVED AFT CARGO PIT RT TRANSITION PANEL IAW SRM 51-40-02. MATERIAL ID FOR CHANNEL, SIDE PLATE AND SPLICE BAC1496-377 7075 T62 IAW SRMSDR ASAA2014051207956Transition Panel · corrodedFWD CARGO BAY RT TRANSITION PANEL HAS KNIFE MARKS ENTIRE LENGTH OF PIT. ACFT GROUNDED. BLENDED KNIFE MARKS AND CORROSION, ORIGINAL MATERIAL .040" MAT LOSS .009 REMAINING .031 IAW SRM 53-30-53 & 53-00-53 FOUND OUT OF LIMITS TOOL T8225M. REMOVED TRANSITION PANSDR ASAA2014051207954Transition Panel · corrodedAFT PIT, LT TRANSITION PANEL CORRODED AT FASTENER HOLES INCLUDING HOLES UNDER SIDEWALL PANELS. FS 272-849. ACFT GROUNDED. R & R AFT PIT LT TRANSITION PANEL IAW SRM 53-00-53-2R-5 AND SRM 51-40-02.SDR ASAA2014051207944Skin · crackedFOUND CRACK ON RT HORIZONTAL STAB LOWER SURFACE APPROX 2.125' LONG, JUST FORWARD OF THE AFT SPAR BETWEEN STABILIZER STA 92.7 AND STABILIZER STA 101.9. AREA MARKED IN RED. ACFT GROUNDED. REPAIRED RT HORIZONTAL STAB LOWER SKIN IAW SRM 55-10-01-2R-11. REMOVED RSDR ASAA2014051207943Skin · crackedFOUND CRACK ON LT HORIZONTAL STAB LOWER SURFACE APPROX 0.75' LONG, 18' FORWARD OF THE AFT SPAR JUST INBD OF STAB STA 101.9. AREA MARKED IN RED. ACFT GROUNDED. REPAIRED LT HORIZONTAL STAB LOWER KSIN IAW SRM 55-10-01-2R-11. REMOVED RED MARKS.SDR ASAA2014051207800Warning Flag · false activationPOWER FAIL FLAG SHOWED UP ON NAV DISPLAY AFTER LANDING. ACFT GROUNDED. NO PERTINENT FAULTS FOUND ON FMC, DFGS, IRS, AND CDU. ACCOMPLISHED TASK 34-43-00-710-802-001. OP CHECKED GOOD.SDR ASAA2014051207787Warning Message · false activationFMC DISAGREE. ACFT GROUNDED. PERFORMED FMC DISAGREE RESET PROCEDURE AS DIRECTED BY QRH. FMC DISAGREE MESSAGE NO LONGER DISPLAYED.SDR ASAA2014051207790Warning Light · false activationON APU START THE FAULT LIGHT CAME ON. RAN QRH WAITED 5 MINUTES. MADE ANOTHER ATTEMPT FAULT LIGHT CAME BACK ON. ACFT GROUNDED. ACCOMPLISHED INLET OVERHEAT SHUTDOWN FAULT PROCEDURE IAW TASK FIM 49-90, TASK 802 BY PULLING & CYCLING CIRCUIT BREAKERS. ORIGINAL FSDR ASAA2014051207788Sensor · failedAPU FAULT LIGHT CAME ON. WITHIN 5 MINUTES FAULT LIGHT WENT OUT. SHUTDOWN APU. ACFT GROUNDED. VERIFIED INLET TEMP SENSOR BAD, READS 300 OHMS PIN TO GROUND, IAW FIM TASK 49-60, TASK 812. REPLACED INLET TEMP SENSOR IAW AMM 49-61-31-000-801 AND 49-61-31-400-801SDR ASAA2014051207785Warning Light · illuminatedELECTRIC WARNING LIGHT ILLUMINATED ON THE OVERHEAD PANEL. ACFT GROUNDED. FOUND STANDBY POWER INOPERATIVE ON ELECTRIC TEST. FAULT CLEARED. UNABLE TO DUPLICATE PROBLEM. REPLACED P5-5 MODULE IAW MM 24-21-52-000-801 AND 400-801, NO DISCREPANCIES NOTED. REPLACSDR ASAA2014051107766Coupler · malfunctionedNR 1 HF WILL NOT TRANSMIT. ACFT GROUNDED. RESET SYS POWER PERFORMED FIM TASK IAW AMM 23-11-801. BITE OF HF SYSTEM PASSED, NO FAULTS FOUND. GROUND VERIFICATION CHECKED OK NO HISTORY PAST 30 DAYS. SYSTEM RESTORED. REPLACED HF ANTENNA COUPLER #1 REF AMM TASKSDR ASAA2014051107771Warning Message · illuminatedDURING TROUBLESHOOTING, NR 2 ENGINE IGNITION FOUND FAULT CODE 73-11452 EVERY FLT LEG SHORT TIME FAULT. ACFT GROUNDED.SDR ASAA2014051107770Igniter · faultedAPU FAULT LIGHT ILLUMINATED DURING START. ACFT GROUNDED. REPLACED IGNITER PLUG, IGNITER PLUG LEAD AND IGNITION UNIT REF AMM 49-41-51, AMM 49-41-52 & AMM 49-41-31. OPS CHECKED GOOD.SDR ASAA2014051107769Apu · malfunctionedAPU WILL NOT START. ACFT GROUNDED. ACCOMPLISHED FIM TASK 49-40, TASK 803. STARTED APU SEVERAL TIMES WITH NO CURRENT 49-41012 FAULT. FAULT CORRECTED IAW FIM. CHECKED MAGNETIC DRAIN PLUG. NO DEBRIS NOTED. NO HISTORY ON CURRENT APU.SDR ASAA2014051107767Module · unknownDURING PREFLIGHT, FOUND ELECTRIC LIGHT ON. ACFT GROUNDED. BITE TEST SHOWS "SPCU INOP" FAULT. CHECKED SPCU FOR INSTALLATION SECURITY & CHECKED RELATED CIRCUIT BREAKERS, NO DEFECTS NOTED. REPLACED P5-13 ELECTRICAL METERS MODULE REF MM 24-21-53. OPS NORMAL.SDR ASAA2014051107765Satcom · malfunctionedNO SATCOM PROMPT. ACFT GROUNDED. PERFORMED QRH PROCEDURE FOR SATCOM LOCKUP SATISFACTORY RESULTS.SDR ASAA2014051007750Exciter · malfunctionedFOUND NR 1 ENGINE WITH FAULT MESSAGE 74-31001. THE INPUT VOLTAGE FOR THE RT EXCITER IS ALWAYS ON. ACFT GROUNDED. OPENSDR ASAA2014051007747Fmc · malfunctionedIN FLIGHT, EXPERIENCED "FMC DATALINK FULL" ANOMALY. ACFT GROUNDED. AFTER LANDING AT GATE ACCOMPLISHED QRH PROCEDURES IAW HANDBOOK BULLETIN. OPS HAS RETURNED TO NORMAL.SDR ASAA2014051007739Satcom · malfunctionedSATCOM INOPERATIVE. ACFT GROUNDED. PERFORMED RESET IAW QRH, OPS NORMAL.SDR ASAA2014050907745Fmc · malfunctionedLEFT FMC INOPERATIVE. ACFT GROUNDED. GROUND VERIFICATION CHECK GOOD. REF AMM 34-61-00-710-801. NO HISTORY PAST 30 DAYS.SDR ASAA2014050907736Control Valve · malfunctionedRT PACK LIGHT ILLUMINATES ON MC RECALL. ACFT GROUNDED. REPLACED THE RT PACK TEMP CONTROL VALVE ASSY REF MM. 21-51-10. OPS, BITES CK GOOD.SDR ASAA2014050907752Lens · brokenF/A REPORTS L1 DOOR EXIT LIGHT LENS COVER BROKEN. ACFT GROUNDED. REPLACED LENS IAW AMM33-29-00.SDR ASAA2014050907746Fmc · malfunctionedNO L NAV DATA IN FMC. ACFT GROUNDED. CYCLED ACFT POWER AND AOC CMU CIRCUIT BREAKER, NORMAL DATA RESTORED.SDR ASAA2014050907741Control Unit · failedOVERHEAD ELECTRICAL PANEL AMBER LIGHT ILLUMINATED. ACFT GROUNDED. FAULT INDICATED SPCU INOPERATIVE. R & R SPCU IAW MM 24-34-11-400-801, OPS NORMAL.
Back to Boeing 737-890