Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022061716138Angle · corrodedCORROSION ON AFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD BS 767+5 RBL 22 WL 156<[01] EVALUATED CORROSION ON ANGLE BS 767+5 RBL 22 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECSDR SWAA2022061716143Strap · corrodedCORROSION ON AFT CARGO BAY FLOOR STRAP BS 887 RBL 6 WL 168 / [01] EVALUATED CORROSION ON FLOOR STRAP BS 887 RBL 6 WL 168; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION #1;[0SDR SWAA2022061716139Strap · corrodedCORROSION ON AFT CARGO BAY FLOOR STRAP BS 767+5 RBL 12 WL 156 / [01] EVALUATED CORROSION ON FLOOR STRAP BS 767+5 RBL 12 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIONSDR SWAA2022061716599Plate · corrodedFWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS 500A TO BS500I RBL23 WL156<[01] EVALUATED CORROSION AT ALL LOCATIONS OF FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 500D+10 RBL 23 WL 156 IN NUMEROUS 1'X1' AREAS; FOUSDR SWAA2022061716600Support Angle · corrodedFWD CARGO BAY AFT LOWER BULKHEAD SUPPORT ANGLE HAS AREAS OF CORROSION BS500I RBL23 TO LBL23 WL156 / [01] EVALUATED CORROSION ON BULKHEAD SUPPORT ANGLE AT ALL LOCATIONS; FOUND THE DEEPEST LOCATION TO BE AT BS 500I RBL 23 WL 156 FOUND 0.021 REMOVED FROM ORIG 0.0SDR SWAA2022061716347Attach Angle · crackedR/H BS663 UPPER ATTACH ANGLE IS CRACKED ON FWD SIDE OF VAPOR BARRIER RBL8 WL 167 / [01] VERIFIED APPLICABILITY OF SRM 57-10-10-2R-5 TO BE CORRECT AND UPDATED MEASUREMENT TABLE;[02] INSTALLED EWIS PROTECTION @ RH BS 663 UPPER ATTACH ANGLE RBL8- RBL20 WL167 ON FSDR SWAA2022061719753Support · corrodedCORROSION ON AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT BS 727F+8 TO BS 847 LBL 23 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS OF FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 747+10 LBL 23 WL 156 IN NUMEROUS 1'X1' AREAS; FOUND TO BE OUSDR SWAA2022061716141Support · corrodedCORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727F+16 TO BS 767 RBL 23 WL 156. REMOVED ACB FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0; SRM 53-00-53-2R-5. FABRICATED; LOCATED AND APPLIED CHEMICAL CONVERSION COATING TO ACB FLOOR TO SIDEWALLSDR SWAA2022061316301Web · crackedLH WING TRAILING EDGE DEFLECTION PANEL WEB ANGLE CRACKED. / [01] INSTALLED LH WING TRAILING EDGE DEFLECTION PANEL WEB ANGLE IAW SRM 51-40-02;[02] INSTALLED LH WING TRAILING EDGE DEFLECTION PANEL WEB ANGLE IAW SRM 51-40-02SDR SWAA2022060916223Light · inoperativeFWD R/H OVERWING EMERGENCY LIGHT INOP / [01] RELAMPED R/H OVERAWING EMERGENCY LIGHT PER AMM 33-51-04SDR SWAA2022060915840Handle · inoperativeFORWARD SERVICE DOOR HANDLE COVER FELL OFF. OK TO CONTINUE PER MEL 25-10-01 SP1B. FOUND MISSING COVER AND INSTALLED ORIGINAL COVER BACK ONTO FWD SERVICE DOOR HANDLE. IAW AMM 52-11-31.SDR SWAA2022060915555Flashlight · inoperativeFO SIDE AFT FA JUMPSEAT FLASHLIGHT INOP / [01] REMOVED AND REPLACED F.O SIDE FLIGHT ATTENDANT FLASHLIGHT BRACKET ASSY REF AMM 25-64-00SDR SWAA2022060915818Flashlight · inoperativeAFT RIGHT FLASHLIGHT LIGHT NOT BLINKING / [01] FLASHLIGHT OPS CK?S NORMAL AT THIS TIME REF AMM 25-64-00SDR SWAA2022062715360Baffle · crackedFWD CARGO HAS A CRACKED BAFFLE BELOW TRANSITION ANGLE AT RBL 25 BETWEEN STATION 500A-500B . / [01] REMOVED DAMAGE BAFFLE FOR REPLACEMENT PER SRM 51-40-02;[02] REMOVED AND REPLACED BAFFLE RBL 25; STA 500A-500B PER SRM 51-40-02.SDR SWAA2022062715361Baffle · crackedFWD CARGO HAS A CRACKED BAFFLE BELOW TRANSITION ANGLE AT RBL 25 BETWEEN STATION 500C-500D . / [01] REMOVED DAMAGE BAFFLE PER SRM 51-40-02;[02] LOCATED AND DRILLED NEW BAFFLE REPLACEMENT PER SRM 51-10-02.;[03] INSTALLED NEW BAFFLES PER SRM 51-40-02.;[04] VERIFISDR SWAA2022061515456Threshold · corrodedDURA RUG; COCKPIT STEP; THRESHOLD HAS CORROSION / [01] REMOVED; REPLACED AND INSTALLED DURA RUG; COCKPIT STEP BS270 LBL10 - RBL10;WL 208 PER SRM 51-40-02-0G-0 AND AIPC 25-27-21-22.;[02] VERIFIED CORRECTIVE ACTION AND MEASURING TABLE UPDATED;[03] CORROSION DAMASDR SWAA2022061415463Tie Down · missingFWD CARGO AFT OF DOOR FLOOR PLATE FLUSH RIVETED TIE DOWN MISSING AND METAL DISTORTED. / [01] REPLACED TIE DOWN PER SRM 51-40-02;[02] INSPECTION COMPLETE ON CORRECTIVE ACTION #1 FOR TIE DOWN REPLACEMENT.SDR SWAA2022060915294Sign · failedOVERWING EMERGENCY EXIT SIGN ON CEILING FELL OUT OVERWING EMERGENCY EXIT SIGN ON CEILING FELL OUT / [01] REPLACED EMERGENCY EXIT MARKER LENS ON CEILING MID CABIN REF AMM 33-51-01SDR SWAA2022060915244Battery Pack · inoperativeAFT ENTRY DOOR AREA EMERGENCY LIGHTS INOP / [01] R&R'D BATTERY PACK AND CHARGER ASSY PER AMM 33-51-06SDR SWAA2022060915401Battery Pack · inoperativeFWD CABIN EXIT SIGN INOP / [01] REPLACED BATTERY PACK PER AMM 33-51-06 AND OPS CHK GOODSDR SWAA2022060815455Light · brokenFWD LAV AFT WALL EMERGENCY EXIT LIGHT ASSEMBLY BROKEN. REMOVED AND REPLACED EXIT LIGHT ASSY ON AFT FACE OF LAV-A BY FED PER AMM 33-51-01-960-802. LIGHT OP CHECKS GOOD.SDR SCNA20220608068Engine · low pressureDEFECT: PRECAUTIONARY SHUTDOWN OF ENGINE #1 DUE TO OIL PRESSURE FLICKERING YELLOW TO RED. OIL QUANTITY AT SHUTDOWN WAS ZERO. RESOLUTION: (IN PROGRESS)SDR SWAA2022061615059Plate · crackedLOWER AFT WING SPAR TRAILING EDGE PANEL 551EB IB ATTACH WAFFLE PLATE IS CRACKED AT OB FASTENER. APPROXIMATELY IRSS 199+20. / [01] REMOVED AND REPLACED WIGGLE PLATE PER SRM 51-40-02;[02] INSPECTED AS REQUIREDSDR SWAA2022061415101Angle · corrodedANGLE AT STA.767-794 R/H SIDE BELOW Z-ANGLE HAS CORROSION-AFT CARGO. (CARD WRITTEN TO ADD CORROSIO QUESTIONS PER MPM) / [01] REMOVED AND REPLACED L ANGLEL BELOW R/H TRANSITION ANGLE BS 767-787 PER SRM 51-40-02;[02] C/W INSPECTION.SDR SWAA2022060815008Light · inoperativeSLIDE / OVERWING EMERGENCY EXIT LIGHT AFT OF L2 DOOR INOP / [01] RELAMPED PER 737 AMM 33-51-04.SDR SWAA2022060815283Girt Bar · stuckSERVICE DOOR GIRT BAR STUCK / [01] STRAIGHTENED GIRT BAR HOOK PER SIP.SDR SWAA2022060815001Light · crackedR1 THRESHOLD EMERGENCY LIGHT CRACKED. / [01] R&R R1 THRESHOLD EMERGENCY LIGHT ASSEMBLY IAW AMM 33-51-01.SDR SWAA2022060815270Flashlight · inoperative1 AFT FLASHLIGHT NEEDS REPLACEMENT / [01] R-R #1 AFT FLASHLIGHT BATTERY & TEST GOOD PER 25-64-00SDR SWAA2022060814729Light · inoperativeAFT GALLEY AND AFT RH CABIN EMERGENCY LIGHTS INOP / [01] REMOVED AND INSTALLED SERVICABLE AFT GALLEY LH/RH POWER SUPPLIES AND AFT CABIN RH POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD;[02] INSPECTED AS REQUIREDSDR SWAA2022060715022Mount · faultyOBSERVED LIGHT TO MILD FUMES. QRF FUMES CHECKLIST COMPLETE. NO FURTHER FUMES OBSERVED / [01] PERFORMED CONDITIONAL INSPECTION PER AMM 05-51-56. FOUND WEATHER RADAR RT FAN BAD.;[02] R&R THE WEATHER RADAR RECEIVER/TRANSMITTER MOUNT IAW AMM 34-43-31. NO SMOKE NOTSDR SWAA2022062714559Panel · delaminatedPANEL 194CL HAS OF DELAMINATION ON OUTSIDE SKIN PANEL 194CL HAS A SPOT OF DELAMINATION ON OUTSIDE SKIN / [01] REMOVED DAMAGE PER SRM 51-70-01-2R-1;[02] INSPECTED WORK PERFORMED ON C/A #1;[03] POTTED CORE PER SRM 51-70-05-2R-11;[04] INSPECTED WORK PERFORMED ON SDR SWAA2022060614696Flashlight · inoperativeFWD FLT ATTENDANT JUMPSEAT EMERGENCY FLASHLIGHT INDICATOR LIGHT IS BLINKING RED / [01] R/R FWD OTB EMERGENCY FLASHLIGHT BATTERY REF 25-64-00SDR SWAA2022060614521Flashlight · inoperativeEMERGENCY FLASHLIGHTS IN AFT GALLEY ON B SIDE WILL NOT TEST. / [01] RESEATED FLASH LIGHTS IN CRADLE OPS CHECKS GOOD IAW MM 25-64-00SDR SWAA2022060614523Flashlight · inoperativeF/A EMERGENCY FLASHLIGHT IN FWD GALLEY IS FLASHING RED / [01] REMOVED AND REPLACED FWD FLASHLIGHT BATTERY PER AMM 25-64-00SDR SWAA2022060614499Battery Pack · inoperativeEMERGENCY BATTERY PACK M1670 INOPERATIVE / [01] R/R BATERRY PACK FROM EMERGENCY POWER SUPPLY M1670 AND OPERATIONAL CHECK FOUND SATISFACTORY PER A.M.M. 33-51-06.;[02] S/N OFF 221516SDR SWAA2022060614354Water Heater · smokeFLIGHT ATTENDANTS REPORT FWD LAV WATER HEATER OVERHEATING FOLLOWED BY FWD LAV SMOKE ALARM. NO SMOKE OR VAPING REPORTED. WATER HEATER WAS TURNED OFF AS A PRECAUTION / [01] OK TO CONTINUE PER MEL 38-2-02 SP1B. WATER HEATER OFF. LAV INOP;[02] REMOVED AND REPLACEDSDR SWAA2022060614526Cover · missingEXIT SIGN COVER MISSING AT AFT RIGHT OVERWING EXIT / [01] INSTALLED A NEW EMERGENCY EXIT LIGHT AS REQUIRED. LIGHT OPS CKS GOOD IAW AMM 33-51-01.SDR SWAA2022060614909Pump · faultyDURING TAKEOFF ROLL; AFTER SELECTING TO/GA; THRUST LEVERS ADVANCED TO 91.8% WHEN 98.7% WAS REQUIRED. NEXT MANUALLY ADVANCED BOTH THRUST LEVERS. #1 ONLY MADE TO 92%. #2 AT 98.7%. #1 THRUST LEVER (CONT) ADVANCED FULL FORWARD. HIGHEST #1 OBSERVED STAYED AT 92%. RSDR SWAA2022061614186Support Angle · crackedFOOR SUPPORT ANGLE AT STA 540 FROM BL 0 TO RBL 24 AND BL 0 TO LBL24 CRACK AT FASTNER HOLE. / [01] PARTS DATA UPDATE ONLY;[02] REMOVED AND REPLACED FLOOR SUPPORT ANGLE PER SRM 51-40-02.;[03] C/W INSPECTIONSDR SWAA2022061614014Fitting · crackedCORNER ATTACH FITTING FOR RH WING PANEL 661AB IS CRACKED. (MARKED) / [01] REMOVED AND REPLACED FITTING PER SRM 51-40-02.;[02] VERIFIED REMOVED AND REPLACED FITTING PER SRM 51-40-02.;[03] ADJUSTMENT CK GOOD PER AMM 27-51-11;[04] SAFETIED PER AMM 27-51-11;[05] SSDR SWAA2022061414091Angle · corrodedANGLE AT STA.767-794 R/H SIDE BELOW Z-ANGLE HAS CORROSION-AFT CARGO / [01] REMOVED AND REPLACED WITH NEW ANGLE 146A8125-53 PER SRM 51-40-02SDR SWAA2022060614331Sign · out of positionMID CABIN OVERHEAD EXIT SIGN FELL OFF. / [01] RESECURED EXIT SIGN PER SIP.SDR SWAA2022060613713Battery Pack · failedONE EACH EMERGENCY LIGHT BATTERY PACK FAILED CAPACITY TEST. / [01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT AFT GALLEY (M01673) PER AMM 33-51-06SDR SWAA2022060614047Seal · crackedLH HORIZONTAL STABILIZER UPPER SLIDING SEAL IS CRACKED / [01] R&R LH HORIZONTAL STABILIZER UPPER FWD SLIDING SEAL REF AMM 53-31-31.SDR SWAA2022061613723Beam · corrodedCORROSION ON BS 947 BEAM UPPER CHORD LBL 46 WL 208 CORRECTION TO FAULT: CORROSION ON BS 947 BEAM UPPER CHORD LBL 56 WL 208 / REMOVED DAMAGE PART OF THE BS947 UPPER FLANGES FROM LBL8.5-LBL59 WL208 I.A.W SRM 53-70-51-2R-5 REPAIR 5 ALTERNATIVE 2 FIG 206 PAR.4.C;FSDR SWAA2022061613738Support Angle · corrodedCORROSION ON FSD MOPSILL THRESHOLD SUPPORT ANGLE BS 294+18-312+12 RBL 57 WL 208 / [01] VERIFIED APPLICABILITY OF REMOVAL OF CORROSION PER SRM 53-10-15-1A-2.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED CORROSION FROM FSD MOPSILL THRESHOLD SUPPORT ANGLE IAW SDR SWAA2022061613720Beam · corrodedCORROSION ON BS 947 BEAM UPPER CHORD LBL 26 WL 208 / [01] VERIFIED APPLICABILITY PER SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR.4.H.(2)(B) FIGURE 104/ALLOWABLE DAMAGE 1 DETAIL C;[02] EVALUATED CORROSION ON BS947 LBL26-LBL56 WL208 2'X1' ORIGINAL MATERIAL THICKNESSDR SWAA2022061513734Floor Support · crackedCRACKED FLOOR SUPPORT AT BS 350 LBL 11 WL 208 / [01] REMOVED; LOCATED AND DRILLED NEW FLOOR SUPPORT AT BS 344 - BS 360 LBL 11 WL 208 IAW SRM 51-40-05-0G-0 AND DWG 141A5400. OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION ITEM 1. OKAY TO INSTALL NEW FLOOR SUPPORTSDR SWAA2022061513735Floor Support · crackedCRACKED FLOOR SUPPORT AT BS 350 RBL 11 WL 208 / [01] REMOVED; LOCATED AND DRILLED NEW FLOOR SUPPORT AT BS 344 - BS 360 RBL 11 WL 208 IAW SRM 51-40-05-0G-0 AND DWG 141A5400. OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION ITEM 1. OKAY TO INSTALL NEW FLOOR SUPPORTSDR SWAA2022061513736Floor Support · crackedCRACKED FLOOR SUPPORT AT BS 277-294 BL0 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 277-294 BL 0 WL 208 IAW SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED NEW FLOOR SUPPORT AT BS 277-294 BL 0 WL 208 IAW SRM 51-40-05-0G-0 AND BOEING DOCUMENT NUMBER 141A5400
Back to Boeing 737-8H4