Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022061513741Support Angle · damagedAFT CARGO BAY SUPPORT ANGLE IS DAMAGED BS 767 TO BS 779 RBL 21 WL 156 / [01] REMOVED AFT CARGO BAY SUPPORT ANGLE SHIELD BS 767 -BS779 RBL 21 WL 156 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED ACB SUPPORT ANGLE AT BS767 - BS787; RBL21; WL156 PER SRM 51-40-05SDR SWAA2022061413833Angle · corrodedAFT CARGO RH Z ANGLE HAS CORROSION ON BOTTOM SIDE AT STA 767-794 / [01] REMOVED R/H SHIELD FROM STA 767-794 PER SRM 51-40-02.;[02] REMOVED AND REPLACED AFT CARGO RT TRANSITION ANGLE SHIELD FROM STA 767 TO STA 794 IAW SRM 51-40-02.SDR SWAA2022060613496Cover · missingEMERGENCY EXIT LIGHT COVER ON FLOOR LEVEL AT ROW 14 DEF MISSING. / [01] INSTALLED EXIT LIGHT COVER AT ROW 14DEF AIW AMM 33-51-01; OPS CHECK GOOD.SDR SWAA2022060613619Sign · brokenEMERGENCY EXIT SIGN ON OVERHEAD BETWEEN OVERWING EXITS IS BROKEN / [01] INSTALLED LENS COVER IAW AMM 33-51-01 NO FURTHER DEFECTS FOUND.SDR SWAA2022060613621Sign · out of positionMID CABIN OVERHEAD EXIT SIGN/PLACARD FELL OFF / [01] RESECURED OVERHEAD EXIT SIGN PER AMM 33-51-01. OK TO CONTINUESDR SWAA2022060213497Slide · failedFWD ENTRY DOOR WAS NOT DISARMED PRIOR TO OPENING DOOR; SLIDE DID NOT DEPLOY NUT IS OUT PARTIALLY / [01] REINSTALLED FWD ENTRY SLIDE PER AMM 25-66-01. A/C OK FOR SERVICE.SDR SWAA2022060213500Light · brokenEXIT SIGN ABOVE EMERGENCY EXIT DOORS/CENTER AISLE IS BROKEN / [01] REHUNG EXIT SIGN AND REPLACED PWR SUPPLY IAW AMM 33-51-01;33-51-06SDR SWAA2022060213507Light · out of positionEXIT ROW SIGN AT FORWARD EMERGENCY EXIT ON RIGHT SIDE OF AIRCRAFT HAS COVER THAT IS COMING OFF / [01] RE INSTALLED RH FWD OVERWING EMERGENCY EXIT DOOR LIFT HANDLE COVER PER AMM 52-22-51SDR SWAA2022062713141Intercostal · crackedPASSENGER CABIN STA 294 TO 276; RBL 1 ;WL 208 INTERCOSTAL AT NUT PLATE AREA IS CRACKED. / [01] REMOVED INTERCOSTAL IAW SRM 51-40-02.;[02] C/W REMOVED INTERCOSTAL IAW SRM 51-40-02.;[03] INSTALLED NEW INTERCOSTAL IAW SRM 51-40-02.;[04] INSPECTED WORK PERFORMED.SDR SWAA2022062713142Intercostal · crackedPASSENGER CABIN STA 312 TO 328 LBL 46; WL 208 INTERCOSTAL AT NUT PLATE HOLE IS CRACKED. / [01] REMOVED INTERCOSTAL IAW SRM 51-40-02;[02] C/W REMOVED INTERCOSTAL IAW SRM 51-40-02.;[03] INSTALLED NEW INTERCOSTAL IAW SRM 51-40-02.SDR SWAA2022061413196Angle · corrodedAFT CARGO RH Z ANGLE HAS CORROSION AT STA 847+6 MARKED IN RED. / [01] REMOVED AFT CARGO RH Z ANGLE IAW SRM 51-40-02.;[02] REMOVED AND REPLACED AFT CARGO HOLD SHIELD BETWEEN STA 847 TO STA 867; RBL 24 IAW SRM 51-40-02.;[03] C/W INSPECTION.SDR SWAA2022060213112Slide · out of positionL1 SLIDE UN-STOWED / [01] R/R L1 SLIDE IAW AMM 25-66-01.SDR SWAA2022060212979Light · inoperativeR/H OVERWING EMERGENCY LIGHTS SINGS INOP. / [01] R+R R/H OVERWING SIGNS BATTERY PACK PER AMM 33-51-06. OPS CK GOOD.SDR SWAA2022062712609Scuff Plate · crackedAFT CARGO AFT CORNER SCUFF PLATE IS CRACKED / [01] REMOVED AND REPLACED AFT CORNER WITH SERVICABLE PART FROM STOCK PER A/M/M 52-11-02;[02] C/W INSPECTION;[03] REMOVED AND REPLACED SCUFF PLATE PER AMM 52-11-00.;[04] UPDATED SELECT REF TO AMM 52-11-02;[05] CERTISDR SWAA2022062712811Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500C +12 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500C + 12? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] MEASURSDR SWAA2022062712815Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500D +11 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500D + 11? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] REMOVESDR SWAA2022062712816Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500E +2 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500E + 2? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] FWD CARGSDR SWAA2022062712838Doubler · crackedAFT CARGO STA 866; LBL 13 DOUBLER PLATE HAS POSSIBLE CRACK AT RADIUS. / [01] REMOVED CRACKED DOUBLER PLATE FROM AFT CARGO STA 866; LBL 13 PER SRM 51-40-02-0G-0.;[02] REPLACED DOUBLER PER SRM 51-40-02.;[03] C/W INSPECTIONSDR SWAA2022062712807Angle · corrodedFWD CARGO TRANSITION ANGLE AT STA 500A +16 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLEND OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500A + 16?? PER SRM 51-10-02; MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG 103 DETAIL D.;[02] FWD CARGO RHSDR SWAA2022062712817Angle · corrodedFWD CARGO TRANSITION ANGLE AT STA 500B +2 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLEND OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500B + 2?; PER SRM 51-10-02; MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2; FIGURE 103 DETAIL D.;[02] MEASUREMENSDR SWAA2022062712819Angle · corrodedFWD CARGO RIGHT HAND Z ANGLE HAS EVIDENCE OF LIGHT CORROSION FROM 500G-500H. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500G TO 500H PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] MEASURSDR SWAA2022062712820Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500E +7' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500E+7? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL DSDR SWAA2022062712821Angle · corrodedFWD CARGO RIGHT HAND Z ANGLE HAS EVIDENCE OF LIGHT CORROSION FROM 500H-500I. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500H TO 500I PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] MEASURSDR SWAA2022062712822Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500D +11' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500D+11? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAILSDR SWAA2022062712823Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500C + 12' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500C + 12? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETSDR SWAA2022062712824Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500C +19' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500C + 19? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETASDR SWAA2022062712826Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500B +7' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500B + 7? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAILSDR SWAA2022062712809Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500B +11 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLEND OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500B + 11?; PER SRM 51-10-02; MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2; FIG. 103 DETAIL D.;[02] MEASURSDR SWAA2022062712810Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500B +16 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500B + 16? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] MEASURSDR SWAA2022062712812Angle · corrodedFWD CARGO COMPARTMENT R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500 + 6' RBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500 + 6? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL SDR SWAA2022062712827Angle · corrodedFWD CARGO COMPARTMENT R/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500 + 14' RBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500 + 14? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAISDR SWAA2022062712813Angle · corrodedFWD CARGO R/H TRANSITION ANGLE AT STA 500D +2 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500D + 2? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] REMOVED SDR SWAA2022062712818Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500E +19' LBL 25. / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500E+19? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAISDR SWAA2022062712808Angle · corrodedFWD CARGO COMPARTMENT L/H TRANSITION ANGLE HAS CORROSION AT FASTENER HOLE STA. 500B + 16' LBL 25 / [01] BLENDED OUT CORROSION AT FWD CARGO L/H TRANSITION ANGLE STA 500B+16? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAISDR SWAA2022062715667Web · crackedPANEL 424 COWL ASSY - FAN - #2 ENGINE OUTBOARD FAN COWL WEB FWD OF THE OIL SERVICE DOOR CRACKED. (MARKED) / [01] INSTALLED WEB UP TO CHERRYMAX IAW SRM 51-40-02;[02] VERIFIED;[03] REMOVED AND REPLACED WEB IAW SRM 51-40-02 AND SRM 51-30-11SDR SWAA2022062715668Web · crackedPANEL 414 COWL ASSY - FAN - #1 ENGINE INBOARD FAN COWL WEB FWD OF THE OIL SERVICE DOOR CRACKED.(MARKED) / [01] INSTALLED FAN COWL WEB PER SRM 51-40-02 AND 51-30-11.;[02] VERIFIEDSDR SWAA2022061612610Attach Bracket · corrodedEXIT HATCH 832 DROP-DOWN CLOSEOUT ATTACH BRACKET IS CORRODED FROM STA 578+9 TO STA 578+18; LBL 71; WL 221. / [01] REMOVED CORROSION ON BRACKET BS 578+9-578+18 LBL 71 WL221 AREA OF REMOVAL 9'X1' .010 MATERIAL REMOVED.ORIGINAL THICKNESS .050. NO APPLICABLE LIMITSDR SWAA2022061612862Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY LBL21 BS727G+13 - BS747+14; BS777 - BS787+14. MARKED. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+14' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOSDR SWAA2022061612611Attach Bracket · corrodedEXIT HATCH 842 DROP-DOWN CLOSEOUT ATTACH BRACKET IS CORRODED FROM STA 578+12 TO STA 578+16; RBL 71; WL 221. / [01] REMOVED CORROSION ON BRACKET BS 578+9-578+18 RBL 71 WL221 AREA OF REMOVAL 4'X1' .010 MATERIAL REMOVED.ORIGINAL THICKNESS .050. NO APPLICABLE LIMISDR SWAA2022061612863Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727H+9; BS727I - BS787 RBL21. MARKED. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727H+9' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT SDR SWAA2022061512857Attach Angle · crackedCRACKED BULKHEAD PANEL SUPPORT ATTACH ANGLE AT AFT CARGO BAY BS866 LBL11. MARKED. / [01] CRACK IS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN. PART REPLACEMENT IS REQUIRED;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED ACB BULKHEAD PANEL SUPPORT ATTASDR SWAA2022061512859Threshold Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT AFT CARGO BAY BS796 - BS847 RBL 26. MARKED. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 800 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.045' FOUND TO BE OUT OF LIMITS PER SRM 53-60SDR SWAA2022061512861Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS 767 - BS779 RBL21. MARKED. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED FWD SHIELD AT AFT CARGO BAY BS 767-BS 793 PER SDR SWAA2022060112580Coffeemaker · odorFLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR COMING FROM FWD GALLEY COFFEE POT. PULLED THE CB.NO INDICATION OF SMOKE ODOR EVENTUALLY WENT AWAY. / [01] VERIFIED ODOR WAS COMING FROM FWD CM. COMPLIED WITH CONDITIONAL INSPECTION PER AMM 05-51-56. R&R FWD COFSDR SWAA2022060612291Cap · brokenAFT CARGO BAY FORWARD FLOOR CAP STRIP BS 727 IS BROKEN / [01] RECEIVED NEW AFT CARGO BAY FLOOR TRIM CAP STRIP ON PO#811576; NEW STRIP TO BE INSTALLED ON CUST CARD# TTG8Q00BUL1D;[02] VERIFIED CORRECTIVE ACTION 1.SDR SCNA20220603067Floor Support · crackedDEFECT: BAFFLE CRACKED AT BS500A-500B R/H SIDE. RESOLUTION: REMOVED AND REPLACED BAFFLE AT BS500A-500B R/H SIDE IN ACCORDANCE WITH B737 SRM 51-40-02-04-0 PART B.SDR SWAA2022053112566Cover · missingFLIGHT TENNANT REPORTED MISSING EMERGENCY EXIT LIGHT COVER ON (F/O SIDE/ 1ST EXIT / [01] REPLACED EMER EXIT LENSE COVER AT EMER EXIT SIGN PER SIPSDR SWAA2022053112552Flashlight · inoperativeAFT FLASHLIGHT LIGHT NOT BLINKING / [01] R & R?D BATTERY PER M/M 25-64-00SDR SWAA2022053112522Pump · faultyON TAKEOFF WITH TOGA SEL #1 ENG WENT TO 93.5 % N1; #2 ENGINE WENT TO 87.4% N1. ADVANCING (MANUALLY) THE #2 THRUST LEVER DID NOT ADVANCE N1 ABOVE 87.4%. / [01] AFTER INSTALLATION OF FUEL PUMP PACKAGE; #2 ENGINE TAKEOFF POWER IS SATISFACTORY; IAW B737 AMM 71-00-SDR SWAA2022061612136Trans Panel · corrodedAFT CARGO L/H TRANSITION ANGLE STA 727I TO 727J SHOWS SIGNS OF CORROSION. / [01] DEFECT REPAIRED ON CARD TTG8Q00CPMF5.;[02] CW
Back to Boeing 737-8H4