Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022041893791Floorboard · looseEE BAY; FLOORBOARD NOT SECURED NEAR P92. / [01] SECURED FLOORBOARD IN EE BAY NEAR P92 USING SOPM 20-50-01;[02] VERIFIED CORRECTIVE ACTIONS STEP 1.SDR SWAA2022041893774Handle · looseCABIN FWD ENTRY DOOR LOWER AFT ASSIST HANDLE IS LOOSE / [01] READJUSTED CABIN FWD ENTRY DOOR LOWER AFT ASSIST HANDLE PER AMM 20-50-11;[02] READJUSTED CABIN FWD ENTRY DOOR LOWER AFT ASSIST HANDLE PER AMM 52-11-31SDR SWAA2022041893542Vapor Barrier · crackedL/H W/W FWD VAPOR WEB CRACKED JUST INBD OF A SYSTEM PRESSURE MODULE. CRACK MEASURES APPROX 4 / [01] L/H W/W FWD VAPOR WEB CRACKED JUST INBD OF ?A? SYSTEM PRESSURE MODULE. CRACK MEASURES APPROX 4?SRM 57-10-10-1A-2-B00453 (CRACK - STOP DRILL AND SEAL - DVI EVERYSDR SWAA2022051193794Angle · corrodedR/H TRANSITION ANGLE STA 767 THROUGH STA 787; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REPLACED SECTION OF TRANSITION ANGLE FROM STA. 727F +10 TO 767 ON NR# TTG8Q00BU45D;[02] C/W INSPECTION.SDR SWAA2022051193800Angle · corrodedR/H TRANSITION ANGLE STA 747 THROUGH STA 767; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 747 - 767 PER SRM 51-10-02 ; MATERIAL MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTION OF TRANSITSDR SWAA2022051193801Angle · corrodedR/H TRANSITION ANGLE STA 727J THROUGH STA 747; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727J-747 - PER SRM 51-10-02 ; MATERIAL MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTION OF TRANSSDR SWAA2022051193802Angle · corrodedR/H TRANSITION ANGLE STA 727I THROUGH STA 727J; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727I-727J ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTIOSDR SWAA2022051193803Angle · corrodedR/H TRANSITION ANGLE STA 727G THROUGH STA 727G+10; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727G THROUGH 727G+10 ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .005 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] RSDR SWAA2022051193804Angle · corrodedR/H TRANSITION ANGLE STA 727F +10; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727F- ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .005 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-105;[02] REMOVE AND REPLACE R/H TRANSITSDR SWAA2022051193798Web · corrodedAFT CARGO DOOR THRESHOLD WEB HAS EVIDENCE OF CORROSION FROM STA 794 THROUGH STA 847; S-25R / [01] CORROSION FOUND OUT OF LIMITS PER SRM 53-00-53-1A-1<BR>REMOVED FASTENERS OF AFT CARGO THRESHOLD WEB PER SRM 51-40-02.;[02] INSTALLED AFT CARGO WEB P/N 146A8123U25SDR SWAA2022050293872Angle · brokenAFT CARGO BAY LOWER LAV BULKHEAD ANGLE BROKEN BS847 LBL10 WL165 / [01] REMOVED THE DAMAGED ANGLE AND LOCATED AND DRILLED NEW BULKHEAD ANGLE BS 847 LBL10 WL 165 PER SRM 51-40-05-0G-0 AND DWG 149A8102. OK TO INSTALL;[02] NO DATA FOUND ON SRM PART MUST BE REPLACESDR SWAA2022050293662Shield · corrodedFWD CARGO BAY SHIELD AFT OF THE DOOR HAS AREAS OF CORROSION BS 492 TO BS50A RBL23 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 492 TO 500A RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02]SDR SWAA2022050293663Support Plate · corrodedFWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE AS AREAS OF CORROSION BS500A TO BS500I RBL23 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500C+10 RBL 23 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ASDR SWAA2022050293664Support · corrodedFWD CARGO BAY LOWER BULKHEAD SUPPORT AT BS500I HAS A AREAS OF CORROSION RBL21 TO LBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500I RBL 15 WL 156; FOUND 0.020 REMOVED FORM ORIG 0.071 IN NUMEROUS 1'X1' AREAS FOUND TSDR SWAA2022050293665Plate · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727D TO BS787 LBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727G+10 LBL 21 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ARSDR SWAA2022050293658Strap · corrodedAFT CARGO BAY FLOOR SPLICE STRAP BS767+6 HAS AREA OF CORROSION RBL 12 WL 156 / [01] EVALUATED CORROSION ON STRAP BS 767+6 RBL 12 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTISDR SWAA2022050293666Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727F TO BS767 RBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727I+10 RBL 21 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ARSDR SWAA2022050293667Shield · corrodedAFT CARGO BAY SHIELD BS767 TO BS787 HAS AREAS OF CORROSION RBL21 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTISDR SWAA2022050293668Shield · corrodedAFT CARGO BAY LOWER ATTACH ANGLE COMMON TO SHIELD HAS AREAS OF CORROSION BS767 TO BS787 RBL21 WL156 / [01] EVALUATED CORROSION ON ATTACH ANGLE BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 5SDR SWAA2022050293669Splice · corrodedAFT CARGO BAY FLOOR PANEL SPLICE HAS CORROSION BS727I+4 RBL16 WL156 / [01] EVALUATED CORROSION ON STRAP BS 727I+4 RBL 16 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIOSDR SWAA2022042893616Angle · corrodedAFT CARGO PIT LT Z ANGLE BETWEEN BS 727E - 807+10, LBL 23, WL 155 CORRODED ON UPPER SURFACE. REMOVED CORROSION FROM LH Z ANGLE, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. CUTOUT DAMAGE SECTION OF Z ANGLE AND REMOVED IAW SRM 53-00-53-2R-5. FABRICATED SDR SWAA2022042893617Shield · corrodedAFT CARGO PIT FWD SHIELD BETWEEN STA 767+2' TO STA 767+10' RBL 23 WL 155 HAS CORROSION ON UPPER AND LOWER SURFACE / [01] REMOVED CORROSION ORIGINAL T= .050' LOSS OF .006' REMAING T= .044' FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1 TOOLING INFO AAR 35351 CSDR SWAA2022042893824Floor Panel · corrodedAFT CARGO FLOOR PANEL 140EF HAS CORROSION ALONG EDGE A225-003 / [01] EVALUATED DAMAGE TO AFT CARGO FLOOR PANEL 140EF FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-1 PARA 5.A.(B) FIG. 102 SHT 1;[02] VERIFIED ITEM 1;[03] VERIFIED MATERIAL TO FAB NEW PANSDR SWAA2022042793632Floor Panel · corrodedAFT CARGO FLOOR PANEL 140BF HAS CORROSION ALONG EDGE A225-002 / [01] FLOOR PANE DAMAGE OF #140BF EXCEEDS 20 MAX ALLOWABLE INCHES. FOUND TO BE OUT OF LIMITS IAW B-737 SRM 53-00-53-1A-1.;[02] MATERIAL VERIFIED AS .071' 2024-T3 IAW B-737 AMM 25-52-01-201-801. A-TSDR SWAA2022042793612Floor Splice · corrodedA-061 DOT 022 A-061 DOT 021 AFT CARGO PIT FLOOR PNL BREAK AT STA 887 LBL 12 WL 155 CORRODED AT FASTENER HOLE / [01] REMOVED AFT CARGO PIT FLOOR PANEL BREAK ( SPLICE PLATE) IAW AMM 25-52-10-000-801.;[02] VERIFIED NEW PART AS 146A9401-21; IAW AIPC 53-42-11-26; ISDR SWAA2022042793613Angle · crackedA-061 DOT 023 A-061 DOT 021 AFT CARGO PIT LOWER END OF VERTICAL BEAM FOR WASTE TANK CLOSE OUT AT STA 867 LBL 14 WL 155 ATTACH ANGLE CRACKED / [01] REMOVED CRACKED AFT CARGO LOWER VERTICAL BEAM WASTE TANK ATTACH ANGLE AT STA 867 LBL 14 AND REPLACED WITH NEW ATTSDR SWAA2022042793619Floor Panel · corrodedA-061 DOT 030 AFT CARGO PIT FLOOR PANEL BREAK AT STA 767+6' BL 0 TO RBL 23 WL 155 HAS CORROSION ON UPPER SURFACE / [01] VERIFY PART NO. FOR FLOOR SPLICE 146A9401-4 ATAG WN14921 IAW IPC53-42-11-26;[02] VERIFIED STEP 1;[03] REPLACE T SPLICE;[04] OK TO INSTALL;[0SDR SWAA2022042793622Angle · corrodedA-061 DOT 031 AFT CARGO PIT R/H Z ANGLE FROM STA 727G TO STA 747+15' RBL 23 WL 155 CORROSION ON UPPER SURFACE / [01] REMOVED CORROSION FROM RH ZEE ANGLE STA 727G-747+15 ORIINAL T= .045' LOSS OF .009' REM T= .036' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2SDR SWAA2022042793620Angle · corrodedA-061 DOT 032 AFT CARGO PIT ATTACH ANGLE FOR FWD SHIELD STA 767 TO STA 767+15' RBL 23 WL 155 CORROSION AT NUTPLATE HOLES LOWER SURFACE / [01] REMOVED CORROSION FROM ATTACH ANGLE. ORIGINAL T=.050' LOSS OF .006' REMNING .044' FOUND TO BE UT OF LIMITS IAW SRM 53-SDR SWAA2022042793623Baffle · corrodedA-061 DOT 033 AFT CARGO PIT BAFFLE UNDER R/H Z ANGLE BETWEEN STA 747 AND STA 767 RBL 23 WL 155 CORRODED AT NUTPLATES HOLES / [01] REMOVED DAMAGE PART IAW SRM 51-40-02-0G-0;[02] REMOVED CORROSION ON DAMAGE PARTS IAW SRM 51-10-02-0G-0 ITEM 15;[03] EVALUATED ALLOSDR SWAA2022042793629Floor Panel · corrodedFWD CARGO METAL FLOOR PANEL 120DF HAS CORROSION AROUND EDGES. DOT 234/01 / [01] EVALUATED DAMAGE TO FWD CARGO FLOOR PANEL 120DF FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-1 PARA 5.A.(B) FIG. 102 SHT 1;[02] VERIFIED STEP 1; OUT OF LIMITS;[03] VERIFISDR SWAA2022042793631Floor Panel · corrodedAFT CARGO FLOOR PANEL 140AF HAS CORROSION ALONG EDGE A225-001 / [01] EVALUATED CORROSION ON FLOOR PNL 1401F HAVE MORE THAN 20' DAMGE TO PNL OUT OF LIMITS I.A.W 53-00-53-1A-1;[02] VERIFIED ITEM 1;[03] VERIFIED NEW MATERIAL FOR NEW PNL AS 2024-T3-0.071 <BR>ATAG#SDR SWAA2022042093511Light · inoperativeLEFT AFT AISLE EMERGENCY LIGHTS INOP / [01] REMOVED AND REPLACED M1670 BATTERY PACK; OPS CHECKS GOOD PER MM 33-51-00;[02] REMOVED AND REPLACED M1670 BATTERY PACK; OPS CHECKS GOOD PER MM 33-51-00 C/W INSPECTIONSDR SWAA2022041893496Megaphone · missingFWD GALLEY MEGAPHONE MISSING / [01] REPLACED FWD GALLEY MEGAPHONE IAW AMM 25-64-00; AC OK FOR CONTINUED OPERATIONSDR SWAA2022051193016Shield · corrodedRIGHT HAND TRANSITION ANGLE AT STATION 420 TO 440 HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED DAMAGE PER SRM 51-10-02. REMAINING MATERIAL OUT OF LIMITS PER SRM 53-00-53.;[02] DRILLED FASTENER HOLES IN NEW PANEL AND INSTALLED NUTPLATES. OKAY TO INSTSDR SWAA2022051193017Web · corrodedTHE FWD CARGO ENTRY THRESHOLD WEB HAS AREAS OF CORROSION FORM STATION 440 TO 492. / [01] REMOVED .020' MATERIAL; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] DRILLED UP NEW WEB COUNTERSUNK AND ATTACHED NUTPLATES PER SRM 51-40-02;[03] OK TO INSTALL FWD CARGO DOOR SDR SWAA2022051193032Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500H TO 500I HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .006' MATERIAL; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] TRANSITION ANGLE SECTION FROM STA. 460+10 TO 500I TO BE REPLACED ON CARD TTG8Q00BSUBU.;[03] C/WSDR SWAA2022051193031Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500G TO 500H HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .005' MATERIAL ; OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE SECTION FROM STA 460+10 TO STA 500 I TO BE REPLACED ON CARD TTG8Q00BSUBU;[02] C/W SDR SWAA2022051193030Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500F TO 500G HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .020' MATERIAL ; OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE SECTION TO BE REPLACED ON CARD TTG8Q00BSUBU;[02] LINE 1 UNDER CORRECTIVE ACTIONS WSDR SWAA2022051193029Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500E TO 500F HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .010' MATERIAL ; OUT OF LIMITS PER SRM 53-00-53-1A-2. TRANSITION ANGLE SECTION TO BE REPLACED ON CARD TTG8Q00BSUBU.;[02] C/W INSPECTION.SDR SWAA2022051193028Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500B TO 500C HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .008' MATERIAL ; OUT OF LIMITS PER SRM 53-00-53-1A-2. L/H L?L <BR>L/H TRANSITION ANGLE FROM STA 460+10 TO 500 I TO BE REPLACED ON CARD TTG8Q00BSUBU.;[02]SDR SWAA2022051193023Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500A TO 500B HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .008' MATERIAL; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] TRANSITION ANGLE TO BE REPLACED FROM STA 460+10 TO 500I ON CARD TTG8Q00BSUBU.;[03] C/W INSPECTISDR SWAA2022051193010Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500C TO 500D HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED .005' MATERIAL; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] TRANSITION ANGLE TO BE REPLACED FROM STA 460+10 TO 500I ON CARD TTG8Q00BSUBU.;[03] C/W INSPECTISDR SWAA2022051193007Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500D HAS CORROSION ON UPPER SURFACE. / [01] REMOVED .014' MATERIAL OUT OF LIMITS PER SRM 53-00-53-0-1A-2.;[02] TRANSITION ANGLE TO BE REPLACED FROM STA 460+10 TO 500I ON CARD TTG8Q00BSUBU.;[03] C/W INSPECTION.SDR SWAA2022051193005Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 480+14 HAS CORROSION AROUND THE FASTENER HOLE. / [01] TRANSITION ANGLE FROM STA 460+10 TO 500 I TO BE REPLACED ON<BR>CARD TTG8Q00BSUBU.;[02] TRANSITION ANGLE FROM STA 460+10 TO 500 I TO BE REPLACED ON<BR>CARD TTG8Q00BSUBU.SDR SWAA2022051193006Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500 TO 500A HAS CORROSION AROUND THE FASTENER HOLES. / [01] C/W INSPECTION.SDR SWAA2022051193027Angle · corrodedRIGHT HAND TRANSITION ANGLE AT STATION 500H TO 500I HAS CORROSION AROUND THE FASTENER HOLES. / [01] REMOVED AND REPLACED FWD CARGO; R/H TRANSITION/SIDEPLATE ANGLE FROM STA. 500A TO STA. 500I IAW SRM 51-40-02.SDR SWAA2022051193011Angle · corrodedLEFT HAND TRANSITION ANGLE AT STATION 500D HAS EVIDENCE OF CORROSION AT THE INBD ATTACH FASTENER POINT. / [01] REMOVED .014' MATERIAL; OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] SECTION OF TRANSITION ANGLE TO BE REPLACED FROM STA. 460+10 TO 500I ON CARD TTGQ00BSDR SWAA2022051193013Angle · corrodedAT STATION 500I ON THE AFT SIDEWALL ATTACH STRIP; THE AREA THAT SITS ABOVE THE RIGHT HAND TRANSITION ANGLE OTBD SIDE HAS EVIDENCE OF CORROSION. / [01] R&R AFT SIDEWALL ATTACH STRIP (PN 143A9485Y34) PER SRM 51-40-02SDR SWAA2022051193196Floorbeam · corrodedCORROSION ON FLOOR BEAM UPPER SURFACE STA 947.5 LBL 24 UNDER LAV MOUNT / [01] BLENDED SURFACE CORROSION ON UPPER CHORD OF FLOOR BEAM AT STA. 947.5; LBL 24? PER SRM 51-10-02. REMOVED .037? OF MATERIAL FROM UPPER SURFACE CHORD. DAMAGE REMOVAL OUT OF LIMITS PER S
Back to Boeing 737-8H4